ABB3BSE008508R1 DI810

ABB 3BSE008508R1 DI810 Digital Input Module (S800 I/O Series) Part of Model Description 3BSE Product prefix for ABB S800 I/O system modules 8508 Product code for DI810 digital input module R1 Hardware revision number (Revision 1) Core Specifications Parameter Category Details Product Name ABB DI810 Digital Input Module System ABB S800 I/O Distributed Process I/O ...

  • Dettagli del prodotto

ABB3BSE008508R1 DI810

Digital Input Module (S800 I/O Series)

Part of ModelDescrizione
3BSEProduct prefix for ABB S800 I/O system modules
8508Product code for DI810 digital input module
R1Hardware revision number (Revision 1)
  1. Specifiche principali
Categoria dei parametriDettagli
Nome del prodottoABB DI810 Digital Input Module
SistemaABB S800 I/O Distributed Process I/O System
Input Channels16 digital input channels, divided into two groups of 8 channels each
Tensione in ingresso24A DC (wide range: 18V–30V DC)
Corrente in ingresso6mA per channel, massimo. 150mA total
IsolationGroup isolation (two groups × 8 canali), isolation voltage 500V AC
Tempo di rispostaStandard mode: ≤1ms; High-speed mode: ≤0.1ms
DiagnosticaChannel status indication, power supply monitoring, wire break detection
Termination UnitTo be used with TU810/TU812/TU814/TU818/TU830 etc.
Grado di protezioneIP20 (for indoor cabinet mounting)
Alimentazione elettrica24A DC, power consumption approx. 2W
Dimensioni102mm × 119mm × 45mm (W × H × D)
Pesoca. 0.2kg (exact 0.24kg)
Temperatura operativa-20°C fino a +60°C
Temperatura di conservazione-40°C to +85°C
Umidità5%–95% RH (senza condensa)
MontaggioMontaggio su guida DIN standard, compatible with S800 I/O system racks
  1. Recommended Operating Environment
  2. Applicazioni industriali: Process automation control systems, petrochemical, power and energy, metallurgy and mining, paper and printing, food and beverage industries
  3. Network Environment: Supports communication with ABB AC 800M controllers, Freelance controllers, and other brand PLCs
  4. Mounting Location: Installed in control cabinets, close to sensors and actuators to reduce wiring costs
  5. Signal Types: Suitable for dry contacts, wet contacts, NO/NC switch signals, and digital output signals from sensors
  6. Cross-Brand Model Comparison & Alternative
MarcaModelloNome del prodottoParametri fondamentaliDifferences from DI810
Siemens6ES7 131-4BD02-0AB0ET 200S Digital Input Module16 canali, 24A DC, group isolationCompatibilità del sistema (PROFIBUS DP), differences in diagnostic functions
Rockwell1734-IB8POINT I/O 8-Ch Digital Input Module8 canali, 24A DC, individual isolationHalf the number of channels; modulo di espansione richiesto
SchneiderBMXDDI1602Modicon M340 Digital Input Module16 canali, 24A DC, group isolationProtocollo di comunicazione (ModBus TCP), different module dimensions
MitsubishiQX40Q-Series Digital Input Module16 canali, 24A DC, no group isolationDifferent isolation design, different system architecture
OmronCJ1W-ID211CJ-Series Digital Input Module16 canali, 24A DC, group isolationCommunication interface (DeviceNet), differences in diagnostic capabilities
  1. Informazioni ufficiali sugli ordini
Order DetailsDescrizione
Official Order Number3BSE008508R1
Packing ListSingle module including installation manual and product certification documents
Garanzia12 mesi (ABB original factory)
Compatible ControllersABB AC 800M, Freelance, S900, ecc.
Modello sostitutivo3BSE008508R0001 (latest version)
  1. Complete Model List for DI810 Series
ModelloDescrizione
3BSE008508R1Versione standard, 16-channel 24V DC digital input, group isolation
3BSE008508R0001Latest hardware revision with improved diagnostics
3BSE008508R2Enhanced version supporting high-speed response (≤0.1ms)
3BSE008508R3Wide-temperature version, operating range -40°C to +70°C
  1. Engineering Implementation Notes
  2. Note di installazione

Module to be mounted on DIN rail and used with termination units (per esempio., TU810)

Maintain at least 5mm clearance between modules for heat dissipation; avoid high-temperature environments

Route input signal cables separately from power cables to reduce electromagnetic interference

  1. Wiring Standards

Each group of 8 channels shares a common terminal (COM); observe group assignments during wiring

Shielded twisted-pair cable recommended for input signals, with shield grounded at one end

Wire break detection must be enabled in system configuration for monitoring critical signals

  1. System Configuration

Configure module parameters in ABB Control Builder software

Adjustable settings: channel response time, filter time, alarm thresholds, ecc.

Supports online diagnostics and hot-swapping (system-dependent)

  1. Maintenance Tips

Regularly check module status LEDs (energia, channel status)

Avoid hot-swapping to prevent electronic component damage

Clean module with a dry soft cloth only; do not use chemical cleaners

ABB 3BSE008508R1 DI810 è un dispositivo ad alte prestazioni, modulo di ingresso digitale a 16 canali ad alta affidabilità adatto a vari sistemi di controllo dell'automazione industriale. Il suo design isolato in gruppo, ampio intervallo di tensione in ingresso, e le ricche funzioni diagnostiche lo rendono la scelta ideale per il controllo del processo. Per la sostituzione tra marchi diversi, attention must be paid to system compatibility, communication protocols, and isolation characteristics.

Elenco completo dei modelli & Cross-Brand Comparison for ABB S800 I/O Digital Input Modules

Key Overview

Sistema: ABB S800 I/O Distributed Process I/O System, compatible with AC 800M, Freelance, ecc.

Classification: By voltage type (24A DC / 48A DC / 120V e), channel count (8/16/32 canali), isolamento (group isolation / individual isolation)

Caratteristiche principali: Sostituibile a caldo, channel diagnostics, wide-temperature operation, DIN rail mountable

  1. Complete Model List of ABB S800 I/O Digital Input Modules

1.1 24V DC Series (Mainstream General-Purpose)

ModelloOrdine n.CanaliInput TypeIsolationTempo di rispostaCaratteristiche principaliApplicazioni
DI8103BSE008508R116Sink/Source2 groups × 8 canali (500V e)Standard ≤1ms; High-speed ≤0.1msClassic general-purpose, group isolation, rich diagnosticsProcess control, automotive manufacturing, automation lines
DI8113BSE008516R116Sink/Source2 groups × 8 canali (500V e)Standard ≤1ms; High-speed ≤0.1ms48V DC compatible, high-density, flexible sensor compatibilityHigh-volume signal acquisition, 48V DC systems
DI8143BSE008519R116Fonte2 groups × 8 canali (500V e)Standard ≤1msSource input, designed for PNP sensorsSensor signal acquisition, automation equipment
DI8183BSE008522R132Sink2 groups × 16 canali (500V e)Standard ≤1ms32-channel high-density, consente di risparmiare spazio nell'armadioLarge-scale signal monitoring, water treatment systems
DI8203BSE008512R18120V eIndividual channels (250V e)Standard ≤10msAC input, individual isolation, strong anti-interferenceIndustrial equipment, controllo motorio, high-voltage signals
DI8213BSE008513R1848A DCIndividual channels (500V e)Standard ≤1msHigh-voltage DC, individual isolation, alta affidabilitàRail transit, sistemi di potere
DI8253BSE008514R11624A DCIndividual channels (500V e)Standard ≤1msIndividual channel isolation, precise diagnosticsSafety systems, critical signal monitoring

1.2 Special Function Series (Di fascia alta / Sicurezza)

ModelloOrdine n.Caratteristiche principaliApplicazioni
DI8303BSE012291R1SIL3 certified, channel-level redundancy, time stampingSafety Instrumented Systems (SIS), process safety control
DI8313BSE012292R1High-speed response (≤0.05ms), HART compatibleHigh-speed motion control, precision process control
DI8403BSE013234R1Intrinsically safe, for hazardous areas (Ex ia)Petrochemical, minerario, flammable and explosive environments

1.3 Convenzione di denominazione dei modelli

ParteSensoEsempio (DI810)
DIDigital Input ModuleDI = Digital Input
8S800 I/O Series Identifier8 = S800 Series
10Product code (24A DC, 16 canali, group isolation)10 = Basic general-purpose type
R1Hardware revision numberR1 = Initial version
  1. Cross-Brand Model Comparison (By Application Match)

2.1 Siemens Equivalent Models

Modello ABBParametri fondamentaliSiemens EquivalentSistemaDifferenze chiaveConsigli per la sostituzione
DI810 (16DI, 24A DC, group isolation)16 canali, 24A DC, group isolation, 500V AC insulation6ES7131-4BD02-0AB0ET200SProtocollo di comunicazione (PROFIBUS vs PROFINET), diagnostic differencesFunzionalmente equivalente; configuration software adjustment required
DI818 (32DI, 24A DC, group isolation)32 canali, 24A DC, group isolation6ES7131-4BF00-0AA0ET200SPDouble channel count, different module sizeTwo ET200SP modules required
DI820 (8DI, 120V e, individual isolation)8 canali, 120V e, individual isolation6ES7131-4FF00-0AB0ET200SVoltage range, isolation methodSiemens AC input module required for 120V AC
DI830 (SIL3 certified)Safety-rated, channel redundancy6ES7521-1BH10-0AA0S7-1500FSafety certification level, system architectureMust meet SIL3 certification requirements

2.2 Rockwell Equivalent Models

Modello ABBParametri fondamentaliRockwell EquivalentSistemaDifferenze chiaveConsigli per la sostituzione
DI810 (16DI, 24A DC)16 canali, 24A DC, sink/source compatible1734-IB8 ×2POINT I/OHalf channel count; two modules neededExtra module required, slightly higher cost
DI818 (32DI, 24A DC)32 canali, 24A DC, high-density1756-IB16 ×2ControlLogixCommunication interface (ControlNet vs PROFIBUS)Two modules, flexible expansion
DI820 (8DI, 120V e)8 canali, 120V e1794-IA8Flex I/OTipo di tensione, terminal styleFunctionally matched; wiring adjustment required

2.3 Schneider Equivalent Models

Modello ABBParametri fondamentaliEquivalente a SchneiderSistemaDifferenze chiaveConsigli per la sostituzione
DI810 (16DI, 24A DC)16 canali, 24A DC, group isolationBMXDDI1602Modicon M340Protocollo di comunicazione (Modbus TCP vs PROFIBUS)Funzionalmente equivalente; different software platform
DI818 (32DI, 24A DC)32 canali, 24A DCBMXDDI3202KModicon M580Matching channel count, module dimensionsSostituzione diretta; reconfiguration required
DI820 (8DI, 120V e)8 canali, 120V eABE701111Modicon PremiumVoltage range, isolation ratingSchneider AC input module required

2.4 Mitsubishi Equivalent Models

Modello ABBParametri fondamentaliMitsubishi EquivalentSistemaDifferenze chiaveConsigli per la sostituzione
DI810 (16DI, 24A DC)16 canali, 24A DC, group isolationQX40Q SeriesCommunication interface (CC-Link vs PROFIBUS), diagnosticsFunctionally matched; bus module replacement required
DI818 (32DI, 24A DC)32 canali, 24A DCQX80Q SeriesChannel count, system architectureTwo QX80 modules required
DI820 (8DI, 120V e)8 canali, 120V eAY11A SeriesTipo di tensione, module typeMitsubishi AC input module required

2.5 Omron Equivalent Models

Modello ABBParametri fondamentaliEquivalente OmronSistemaDifferenze chiaveConsigli per la sostituzione
DI810 (16DI, 24A DC)16 canali, 24A DC, group isolationCJ1W-ID211CJ SeriesCommunication interface (DeviceNet vs PROFIBUS), terminal styleFunzionalmente equivalente; system configuration adjustment required
DI818 (32DI, 24A DC)32 canali, 24A DCCS1W-ID211CS SeriesChannel count, system performanceTwo modules required, higher cost
DI820 (8DI, 120V e)8 canali, 120V eC200H-ID212C200HVoltage range, isolation methodOmron AC input module required
  1. Key Considerations for Replacement Selection

3.1 Core Matching Criteria

  1. Voltaggio & Canali: Ensure input voltage and channel count match exactly to avoid signal damage or loss
  2. Isolation Method: Group isolation (ABB standard) vs. individual isolation (some Siemens/Mitsubishi models) affects interference immunity and safety rating
  3. Protocollo di comunicazione: PROFINET / PROFIBUS vs. ModBus / CC-Link; must match controller bus
  4. Termination Units: ABB requires TU810/TU812 etc.; cross-brand replacement needs redesigned terminal layout
  5. Diagnostica: ABB channel-level diagnostics vs. module-level diagnostics on other brands, affecting maintenance efficiency

3.2 Engineering Implementation Guidelines

PhaseKey Standards
InstallazioneMust mount on DIN rail; keep ≥30cm from heat-generating devices (inverter); 5mm clearance for cooling
CablaggioUse shielded twisted-pair cable, schermo messo a terra ad un'estremità; group common (COM) wiring to prevent short circuits
ConfigurazioneCross-brand replacement requires full project redevelopment; software incompatible (WinCC vs CX-Programmer vs Unity Pro)
ManutenzioneRegularly check LED status (power/channel/fault); no hot-swapping for non-hot-swap modules

3.3 Priority Recommended Replacement Solutions

ApplicazionePreferred ABB ModelAlternativa multimarcaMotivo
Equivalenza funzionaleDI810 / DI814Siemens 6ES7131-4BD02-0AB0Exact match in channels, voltaggio, and isolation
Cost OptimizationDI818 (32 canali)Rockwell 1756-IB16 ×2High density, conveniente
Safety SystemsDI830Siemens 6ES7521-1BH10-0AA0SIL3 certified, channel redundancy
Hazardous AreasDI840 (intrinsecamente sicuro)Pepperl+Fuchs KFD2-STC4-EX1 + standard DI moduleIntrinsically safe isolation, explosion-proof compliance
  1. & Spare Parts List
  2. Full Range Coverage: ABB S800 I/O digital input modules cover 8–32 channels and 24V DC to 120V AC for all industrial scenarios
  3. Cross-Brand Compatibility: Equivalent models available from major brands; prioritize matching channels + voltaggio + isolamento, then protocol and diagnostics
  4. Spare Parts Recommendation: Stock DI810 (general-purpose), DI818 (high-density), DI820 (AC input) to cover over 80% of applications