M1M: ABB M1M Series Motor Protection and Management Unit (Motor Protection Controller)
2TAZ664052R0007: Corresponding ABB original order number / material code
- Tipo di prodotto
Low-voltage three-phase motor integrated protection relay, used for motor protection, monitoring and basic control.
- Funzioni principali
Sovraccarico, locked-rotor, and underload protection
Phase sequence, phase loss, and phase imbalance protection
Earth fault / earth leakage protection
Motor operating status monitoring and fault output
- Same Series & Modelli alternativi
Same series: Full ABB M1M series (M1M 01/02/03 and other current ratings)
Upgraded alternatives: ABB M102 / M2M series (functionally compatible with enhanced performance)
Cross-brand alternatives: Siemens 3RB series, Schneider EOCR series motor protection relays
- Applicazioni tipiche
Protection for three-phase asynchronous motors such as industrial fans, pompe dell'acqua, trasportatori, e compressori, as well as automated production lines and factory low-voltage power distribution systems.
ABB M1M Series Digital Multifunction Power Meters
- Significato del modello & Posizionamento del prodotto
Ripartizione del modello
M1M: ABB System pro M Series Digital Multifunction Power Meters (not motor protectors; please distinguish carefully)
Suffix numbers: Product function level (10/12/15/20/30); higher numbers indicate richer functions
Complete model example: M1M-2TAZ664052R0007 (2TAZ664052R0007 is the ABB original order number / material code)
Posizionamento del prodotto
ABB’s new-generation modular DIN-rail mounted multifunction power monitoring meters, used for energy metering, power quality analysis, and electrical parameter monitoring in mediumand low-voltage primary and secondary distribution systems. Supports Modbus communication and is suitable for industrial and building applications.
- Full Series Comparison
| Modello | Funzioni principali | Interfaccia di comunicazione | I/O | Tensione di alimentazione | Sample Order No. |
| M1M 10 | Basic energy measurement, no display | Nessuno | Nessuno | No auxiliary power required | 2TAZ661010R2000 |
| M1M 12 | Basic energy measurement, LED indication | Nessuno | Nessuno | No auxiliary power required | 2TAZ661210R2000 |
| M1M 15 | Multifunction measurement, LCD display | Optional Modbus | Nessuno | 100–230V AC/DC | 2TAZ661510R2000 |
| M1M 20 | Multifunction measurement, LCD display | Optional Modbus | Nessuno | 100–230V AC/DC | 2TAZ662010R2000 |
| M1M 30 | Advanced measurement, power quality analysis | Optional Modbus/Ethernet | Optional 2DI/2DO | 100–230V AC/DC | 2TAZ663010R2000 |
| M1M 30 I/O | Advanced measurement + I/O control | ModBus RTU | 2DI/2DO | 100–230V AC/DC | 2TAZ663012R2001 |
| M1M 30 Ethernet | Advanced measurement + Ethernet | Modbus TCP/IP | Nessuno | 100–230V AC/DC | 2TAZ663011R2001 |
- Specifiche tecniche (M1M 30 Serie)
Measurement accuracy: Current/voltage class 0.2, active energy class 0.5S (conforme alla CEI 62053-22), reactive energy class 2
Measured parameters: Three-phase voltage/current, potenza attiva/reattiva/apparente, fattore di potenza, frequenza, energy metering (forward/reverse), analisi armonica (selected models)
CT input: Standard 1A/5A, supports star (3E) or delta (2E) connection
Ingress protection: IP51 (pannello frontale), IP20 (terminali)
Montaggio: 35Guida DIN da mm, 18larghezza mm (1 modulo)
- Scenari applicativi principali
- Sub-metering in commercial buildings (illuminazione, HVAC, power circuits)
- Power distribution system monitoring and energy efficiency analysis in industrial plants
- Power quality monitoring in data centers
- Real-time electrical parameter monitoring in low-voltage distribution cabinets
- Power generation metering for renewable energy systems (PV / wind power)
- Modelli alternativi & Confronto di marca
Upgraded Alternatives (Same Brand)
Function expansion: ABB M2M series (higher accuracy, more communication protocols)
Versione base: ABB M1M 10/12 (basic energy metering, costo inferiore)
Alternative multimarca
| Marca | Recommended Replacement | Note sulla compatibilità |
| Schneider | PowerLogic PM5000 series | Similar functions, compatible communication protocols |
| Siemens | SENTRON PAC series | Comparable measurement accuracy, supports Modbus |
| Alternative domestiche | Acrel PZ series, Chint DTSU series | Cost advantage, compatible basic functions |
- Linee guida per la selezione
- Measurement needs: Basic energy metering → M1M 10/12; real-time monitoring → M1M 15/20; power quality analysis → M1M 30
- Communication needs: Remote monitoring → models with Modbus (M1M 15/20/30)
- Control needs: Digital input/output required → M1M 30 I/O
- Installation environment: Ensure operating temperature range (-25°C to +55°C) and protection class requirements
Complete List of ABB Multifunction Power Meters
This list covers ABB’s mainstream multifunction power meter series, sorted from basic metering to advanced power quality analysis by product positioning. Includes model numbers, core functions, parametri tecnici, order numbers, and application scenarios for easy selection and procurement reference.
- M1M Series (System pro M, Modular DIN-Rail Mounted)
ABB’s new-generation compact multifunction power meters for mediumand low-voltage primary and secondary distribution systems. Only 18mm wide (1 modulo) and supports hot-swap.
I.1 Basic Metering Type (Nessuna visualizzazione / LED Indication)
| Modello | Funzioni principali | Classe di precisione | Comunicazione | I/O | Alimentazione elettrica | Sample Order No. | Applicazione |
| M1M 10 | Three‑phase energy measurement (no display) | Active 0.5S, Reactive 2 | Nessuno | Nessuno | No auxiliary power | 2TAZ661010R2000 | Basic energy statistics, low‑cost applications |
| M1M 12 | Three‑phase energy measurement (LED status indication) | Active 0.5S, Reactive 2 | Nessuno | Nessuno | No auxiliary power | 2TAZ661210R2000 | Simple circuit monitoring, indicazione di guasto |
I.2 Multifunction Display Type (Display LCD)
| Modello | Funzioni principali | Classe di precisione | Comunicazione | I/O | Alimentazione elettrica | Sample Order No. | Applicazione |
| M1M 15 | Three‑phase full‑electrical measurement, LCD display | Active 0.5S, Reactive 2 | Optional Modbus RTU | Nessuno | 100–230V AC/DC | 2TAZ661512R2000 | Sub‑metering in commercial buildings, industrial monitoring |
| 10239994 | |||||||
| M1M 15 I/O | Full‑electrical measurement + 2DI/2DO | Active 0.5S, Reactive 2 | ModBus RTU | 2DI/2DO | 100–230V AC/DC | 2TAZ661512R2001 | Local alarm/control, equipment interlock |
| M1M 20 | Full‑electrical + THD measurement, LCD display | Active 0.2S, Reactive 2 | Optional Modbus RTU | Nessuno | 100–230V AC/DC | 2TAZ662012R2000 | Industrial energy efficiency analysis, power quality monitoring |
| 10239996 | |||||||
| M1M 20 I/O | Full‑electrical + THD + 2DI/2DO | Active 0.2S, Reactive 2 | ModBus RTU | 2DI/2DO | 100–230V AC/DC | 2TAZ662012R2001 | Local control, alarm output |
| M1M 20 Ethernet | Full‑electrical + THD + Ethernet | Active 0.2S, Reactive 2 | Modbus TCP/IP | Nessuno | 100–230V AC/DC | 2TAZ662014R2000 | Network integration, remote monitoring |
I.3 Advanced Power Quality Type
| Modello | Funzioni principali | Classe di precisione | Comunicazione | I/O | Alimentazione elettrica | Sample Order No. | Applicazione |
| M1M 30 | Full‑electrical + analisi armonica (up to 40th), data logging | Active 0.2S, Reactive 2 | Optional Modbus RTU | Nessuno | 100–230V AC/DC | 2TAZ663012R2000 | Analisi della qualità dell'energia, energy optimization |
| 10239997 | |||||||
| M1M 30 I/O | Funzioni complete + 2DI/2DO | Active 0.2S, Reactive 2 | ModBus RTU | 2DI/2DO | 100–230V AC/DC | 2TAZ663012R2001 | Local control + allarme, equipment interlock |
| M1M 30 Ethernet | Funzioni complete + Ethernet | Active 0.2S, Reactive 2 | Modbus TCP/IP | Nessuno | 100–230V AC/DC | 2TAZ663014R2000 | Remote power quality monitoring, system integration |
| M1M 30 I/O Ethernet | Funzioni complete + 2DI/2DO + Ethernet | Active 0.2S, Reactive 2 | Modbus RTU/TCP | 2DI/2DO | 100–230V AC/DC | 2TAZ663014R2001 | Smart power distribution systems, gestione energetica |
Special model: M1M-2TAZ664052R0007 (custom version of M1M series, order no. 2TAZ664052R0007), functions equivalent to M1M 30, for specific project requirements.
- M2M Series (System pro M compact, Panel Mounted)
ABB mid-range power quality analyzers, 96mm wide (4 moduli), suitable for mounting on distribution cabinet doors. Fully functional with advanced power quality analysis.
| Modello | Funzioni principali | Classe di precisione | Comunicazione | I/O | Analisi armonica | Data Logging | Sample Order No. | Applicazione |
| M2M 10 | Full‑electrical measurement, LCD display | Active 0.2S, Reactive 2 | ModBus RTU | 2DI/2DO | Up to 31st | Basic logging | 2CSG299883R4052 | Industrial power monitoring, energy efficiency analysis |
| M2M 20 | Analisi della qualità dell'energia, event recording | Active 0.1S, Reactive 2 | Modbus RTU/TCP | 4DI/4DO | Up to 40th | Advanced logging | 2CSG299884R4052 | Critical load monitoring, fault diagnosis |
| M2M 30 | Advanced power quality, PQDIF export | Active 0.05S, Reactive 2 | Modbus RTU/TCP | 8DI/8DO | Up to 63rd | Comprehensive logging | 2CSG299885R4052 | Data centers, critical production equipment |
| Ethernet/IP |
III. M4M Series (Network Analyzers)
ABB high-end power quality analyzers, standalone installation, for mediumand high-voltage distribution systems, providing complete power quality analysis and energy management.
| Modello | Funzioni principali | Classe di precisione | Comunicazione | I/O | Analisi armonica | Data Logging | Applicazione |
| M4M 100 | Full parameter measurement, power quality analysis | Active 0.02S, Reactive 1 | Modbus RTU/TCP | 16DI/16DO | Up to 63rd | Large‑capacity storage | Medium‑/high‑voltage distribution, grid monitoring |
| DNP3 | |||||||
| M4M 200 | Advanced power quality, power quality reporting | Active 0.01S, Reactive 1 | Modbus RTU/TCP | 24DI/24DO | Up to 127th | Massive storage | Grid custody metering, power trading |
| DNP3 | |||||||
| CEI 61850 |
- D1M Series (System pro M Distributed Monitoring)
ABB distributed power monitoring system supporting centralized monitoring of multiple circuits, ideal for large buildings and industrial plants, with remote management via gateways.
| Modello | Funzioni principali | Monitored Circuits | Comunicazione | I/O | Alimentazione elettrica | Applicazione |
| D1M 10 | Centralized monitoring of 4 circuits | 4×three‑phase | ModBus RTU | 8DI/4DO | 24A DC | Edifici commerciali, multi‑story plants |
| D1M 20 | Centralized monitoring of 8 circuits | 8×three‑phase | Modbus RTU/TCP | 16DI/8DO | 24A DC | Large shopping malls, industrial parks |
- EM Series (Smart Power Meters)
ABB economical multifunction power meters for small buildings and industrial applications, cost-effective and flexible installation.
| Modello | Funzioni principali | Classe di precisione | Comunicazione | I/O | Alimentazione elettrica | Applicazione |
| EM 20 | Single‑phase current/voltage measurement | Attivo 1, Reactive 2 | Nessuno | Nessuno | No auxiliary power | Residential, small shops |
| EM 100 | Single‑phase full‑electrical measurement | Active 0.5S, Reactive 2 | Optional Modbus | 2DI/2DO | 100–230V AC/DC | Small commercial, lighting circuits |
| EM 200 | Three‑phase full‑electrical measurement | Active 0.5S, Reactive 2 | Optional Modbus | 4DI/4DO | 100–230V AC/DC | Piccole fabbriche, edifici per uffici |
| EM 400 | Three‑phase full‑electrical + analog output | Active 0.2S, Reactive 2 | Optional Modbus | 4DI/4DO | 100–230V AC/DC | Process control, equipment interlock |
| 2AO |
- Other Series (Special Applications)
| Serie | Modello | Funzioni principali | Scenari applicativi |
| IM Series | IM302 | Smart power monitoring, event recording | Automazione industriale, equipment monitoring |
| LNP3 Series | LNP301 | Energy metering, remote meter reading | Public utilities, smart grids |
| PMU Series | PMU6000 | Multifunction measurement, power quality analysis | Large‑scale industry, gestione energetica |
VII. Guida alla selezione (By Application)
- Basic energy metering: Choose M1M 10/12 or EM 20/100, basso costo, meets basic statistical needs
- General power monitoring: Choose M1M 15/20 or M2M 10, funzioni complete, supports Modbus communication
- Analisi della qualità dell'energia: Choose M1M 30 or M2M 20/30, harmonic analysis up to 40th/63rd, supports event recording
- Medium-/high-voltage distribution: Choose M4M series, high-accuracy measurement, complete power quality analysis, supports IEC 61850
- Multi-circuit centralized monitoring: Choose D1M series, distributed architecture, reduces wiring and costs-
VIII. Core Technical Parameter Comparison
| Serie | Precisione della misurazione | Analisi armonica | Communication Protocols | Capacità I/O | Montaggio | Larghezza |
|---|---|---|---|---|---|---|
| M1M | 0.5S ~ 0.2S | Up to 40th | Modbus RTU/TCP | 0~2DI/2DO | Guida DIN | 18mm |
| M2M | 0.2S ~ 0.05S | Up to 63rd | Modbus RTU/TCP Ethernet/IP | 2~8DI/DO | Panel mount | 96mm |
| M4M | 0.02S ~ 0.01S | Up to 127th | Modbus RTU/TCP DNP3 CEI 61850 | 16~24DI/DO | Standalone / 19″ rack | 19″ |
| D1M | 0.5S | Up to 31st | Modbus RTU/TCP | 8~16DI/DO | Guida DIN | 72mm |
| EM | 0.5S ~ Class 1 | Up to 15th | Optional Modbus | 0~4DI/DO | Guida DIN | 36mm |
Contattore,interruttore automatico,inverter solare,contatore elettrico,batterie solari


















NH42-63-318x560.png)