CHINT JYB-714 Relè livello liquido 3A AC220V - Contattore,interruttore automatico,inverter solare,contatore elettrico,batterie solari

Wechat: +86-13184948252 Whatsapp: 0086-13811255435 E-mail: kent@bestcontactor.com

Di Contatto |

CHINT JYB-714 Relè livello liquido 3A AC220V - Contattore,interruttore automatico,inverter solare,contatore elettrico,batterie solari

contatore elettrico/elettrico/

CHINT JYB-714 Relè livello liquido 3A AC220V

Full Name: CHINT JYB-714 Series Liquid Level Relay (YB-714 is a simplified model) Specifiche chiave: Control voltage: AC220V 50Hz Contact rating: 3A AC220V (carico resistivo) Configurazione dei contatti: 1 changeover contact (NO + NC) Probe current: ≤ 50μA (safe low current) Control distance: ≤ 1km (length of probe cable) Temperatura operativa: -5°C ~ +40°C Core Functions ...

  • Dettagli del prodotto

Full Name: CHINT JYB-714 Series Liquid Level Relay (YB-714 is a simplified model)

Specifiche chiave:

Control voltage: AC220V 50Hz

Contact rating: 3A AC220V (carico resistivo)

Configurazione dei contatti: 1 changeover contact (NO + NC)

Probe current: ≤ 50μA (safe low current)

Control distance: ≤ 1km (length of probe cable)

Temperatura operativa: -5°C~+40°C

  1. Funzioni principali & Applicazioni

Funzione: Detects water level via electrodes, automatically controls pump start/stop, supporting water supply / drainage modes.

Applicazioni tipiche:

Civil water towers, elevated tanks, underground cisterns

Industrial circulating water systems, small sewage treatment equipment

Not suitable for: Oil, pure water (low conductivity), flammable and explosive liquids

  1. Operating Principle (Electrode Detection)
  2. Water Supply Mode: When water level is below the low limit, electrodes 5-6 conduct, relay energizes, pump starts. When water rises to high limit, electrodes 6-7 conduct, relay de-energizes, pump stops.
  3. Drainage Mode: When water level exceeds high limit, electrodes 6-7 conduct, relay energizes, pump starts. When water drops to low limit, electrodes 5-6 disconnettersi, relay de-energizes, pump stops.
  4. Terminal Definition (Standard 8‑pin Base)
Terminal No.FunzioneWiring Description
1Power Line LConnect to AC220V Live wire
2Normalmente chiuso (NC)Commonly used for drainage mode
3Comune (COM)Common terminal of contacts
4Normalmente aperto (NO)Commonly used for water supply mode
5Power Neutral NConnect to AC220V Neutral wire
6Middle Level ElectrodeMain detection electrode
7High Level ElectrodeUpper limit stop detection
8Low Level ElectrodeLower limit start detection
  1. Typical Wiring (Single‑phase Water Pump)
  2. Water Supply Control:

terminale 1 to L, terminale 5 to N

terminale 6 to middle level, 7 to high level, 8 to low level

terminale 4 (NO) + terminale 3 (COM) connect to contactor coil control

  1. Drainage Control:

terminale 1 to L, terminale 5 to N

terminale 6 to middle level, 7 to high level, 8 to low level

terminale 2 (NC) + terminale 3 (COM) connect to contactor coil control

  1. Installazione & Note sull'utilizzo
  2. Electrode Installation:

Electrode material: 304 stainless steel recommended for corrosion resistance

Spacing: ≥ 10cm between high/low electrodes; ≥ 15cm between electrodes and tank wall

Avoid installation in bubble‑prone areas

  1. Electrical Safety:

Route signal cables separately, keep ≥ 30cm from power cables

Must be protected by a 10A circuit breaker

Use waterproof junction boxes in damp environments

  1. Manutenzione giornaliera:

Clean scale and dirt from electrodes regularly to maintain conductivity

Inspect probe cable insulation for damage

  1. Difetti comuni & Risoluzione dei problemi
Fault SymptomPossible CauseSoluzione
No operation at allPoor power connection / incorrect voltageMeasure AC220V between terminals 1 E 5
Fails to detect water levelBroken probe wire / electrode foulingControllare il cablaggio, clean electrodes
Malfunction / false triggeringExcessively high sensitivity / shorted electrodesAdjust electrode spacing, check insulation
Contact welding / stickingSovraccarico / contact agingReplace relay; install freewheeling diode across contactor coil
  1. Selezione & Alternative

Upgraded Model: JYB-714B (with LED indicator for clearer status)

Alternative Brands: Xinling HHY7G/HHY7P, People Electrical Appliance JYB series (parameter‑compatible)

Nota: For high‑power pumps, must use an AC contactor; do not drive directly (limited 3A contact capacity)

Recommended Replacements for CHINT JYB-714 (YB-714) 3A AC220V Liquid Level Relay

  1. CHINT Original Upgraded Alternatives
ModelloKey ImprovementsApplicazione
JYB-714B AC220VAdded LED operating status indicator for clear visualizationAll basic level control requiring status indication
JYB-714C AC220VDual LED indicators (supply/drain), enhanced anti-interferenceIndustrial environments with frequent mode switching

Matching Core Parameters: All retain 3A AC220V contact rating, 1 changeover contact, electrode detection, fully compatible with original base and wiring.

  1. Direct Domestic Brand Alternatives (100% Parameter Compatible)
  2. Delixi Series

JYB-714 AC220V (tipo standard)

JYB-714A AC220V (improved, stronger anti-interference)

Caratteristiche: Same platform design as CHINT, universal 8‑pin base, prezzo più basso, wide service network.

  1. Xinling Electric Series

HHY7G AC220V (water supply dedicated)

HHY7P AC220V (drainage dedicated)

Caratteristiche: 3A AC220V contact rating, control distance up to 100m, suitable for long probe cables.

  1. People Electrical Appliance Series

JYB-714 AC220V liquid level relay

Caratteristiche: Compliant with GB/T14048.5, excellent moisture resistance, ideal for humid environments.

  1. Specialized Alternatives (Upgraded Functions / Ambienti speciali)
  2. CKC (Taiwan)

C61F-GP-N AC220V non-float liquid level relay

Vantaggi: Imported quality, strong anti-interference, suitable for precision control, supports 3A AC220V load.

  1. OMRON

61F-GP AC220V liquid level control relay

Vantaggi: Internationally renowned, alta affidabilità, LED status indication, adatto per apparecchiature critiche.

Nota: Requires dedicated base, higher cost.

  1. Wireless / Smart Alternative

CHINT NB-IoT Intelligent Liquid Level Controller: Remote monitoring, mobile APP control, suitable for unattended sites.

Caratteristiche: No wiring needed, data transmission via NB-IoT, supports water level alarms and history query.

  1. Key Compatibility Requirements for Replacement
Key ParameterMust MatchNote
Contact Rating3A AC220V (carico resistivo)Direct for small loads; contactor required for high power
Configurazione dei contatti1 changeover contact (NO + NC)Ensures both supply and drainage modes
Tensione operativaAC220V 50HzMatches original power supply
Mounting BaseStandard 8‑pin baseDirect replacement without re-drilling
Detection MethodElectrode type (≤50μA safe current)Compatible with existing probe cables
  1. Recommendation Priority
  2. Prima scelta: CHINT JYB-714B/C → Original upgrade, pienamente compatibile, clear indication
  3. Best Value: Delixi JYB-714A → Affordable, stable, convenient service
  4. Industrial Use: Xinling HHY7G/7P → Long distance, strong anti-interference
  5. Attrezzatura critica: OMRON 61F-GP → High reliability for continuous operation

Complete Model List of CHINT Liquid Level Relays

CHINT liquid level relays are available in three main series: JYB-714 (basic type), NJYW1 (industrial enhanced type), and NJB1-YW (modular type). Below is the complete model list by series.

  1. JYB-714 Series (Core Basic Series)

1.1 Standard Models

ModelloTensione di controlloCaratteristiche principaliSample Order No.
JYB-714 AC36VAC36V 50HzVersione base, no indicator710039910301036
JYB-714 AC220VAC220V 50HzVersione base, no indicator710039910301037
JYB-714 AC380VAC380V 50HzVersione base, no indicator710039910301038

1.2 Upgraded Models (with LED Indicator)

ModelloTensione di controlloCaratteristiche principaliSample Order No.
JYB-714B AC36VAC36V 50HzSingle LED operation indicator710039910301378
JYB-714B AC220VAC220V 50HzSingle LED operation indicator710039910301379
JYB-714B AC380VAC380V 50HzSingle LED operation indicator710039910301380
JYB-714C AC220VAC220V 50HzDual LED (supply/drain), enhanced anti-interference710039910401379
JYB-714C AC380VAC380V 50HzDual LED (supply/drain), enhanced anti-interference710039910401380

Common Parameters:

Contact rating: 3A AC220V (carico resistivo)

Configurazione dei contatti: 1 changeover contact (NO + NC)

Probe current: ≤ 50μA

Control distance: ≤ 1km

Montaggio: Standard 8‑pin base (universale)

  1. NJYW1 Series (Industrial Enhanced Series)
ModelloTensione di controlloCaratteristiche principaliApplicazione
NJYW1-NL1 AC220VAC220V 50HzStandard, moisture-resistantCivil / light industrial water towers
NJYW1-NL1 AC380VAC380V 50HzStandard, moisture-resistantIndustrial water tanks
NJYW1-NL2 AC220VAC220V 50HzLunga distanza (≤2km)Large water conservancy
NJYW1-NL2 AC380VAC380V 50HzLunga distanza (≤2km)Sewage treatment plants
NJYW1-BL1 AC220VAC220V 50HzExplosion‑proofChemical industry, underground pump rooms
NJYW1-BL1 AC380VAC380V 50HzExplosion‑proofPetrochemical tank farms
NJYW1-BL2 AC220VAC220V 50HzExplosion‑proof + lunga distanzaOffshore platforms, mine drainage
NJYW1-BL2 AC380VAC380V 50HzExplosion‑proof + lunga distanzaTunnel drainage systems

Series Advantages: Protection class IP40, improved anti-interference, stable probe current ≤40μA.

  1. NJB1-YW Series (Modular Series)
ModelloTensione di controlloMontaggioApplicazione
NJB1-YW AC220VAC220V 50HzMontaggio su guida DINAutomation control panels
NJB1-YW AC380VAC380V 50HzMontaggio su guida DINSistemi di automazione industriale
NJB1-YW DC24VDC24VMontaggio su guida DINDC control systems, PLC integration

Caratteristiche:

Montaggio su guida DIN (35norma mm) for automation integration

Fault diagnosis, PLC compatible

Contact rating increased to 5A AC220V, suitable for direct small pump control

  1. Model Naming Explanation
  2. JYB-714 Series: JYB (liquid level relay)-714 (design code)-[A/B/C] (versione: A=basic, B=single LED, C=dual LED)-voltaggio
  3. NJYW1 Series: N (CINT) JYW (liquid level relay) 1 (codice)-[NL/BL] (NL=standard, BL=explosion‑proof)-[1/2] (distanza: 1=1km, 2=2km)-voltaggio
  4. NJB1-YW Series: N (CINT) JB (modular) 1 (codice)-YW (liquid level control)-voltaggio
  5. Selection Parameter Comparison
ParametroJYB-714 SeriesNJYW1 SeriesNJB1-YW Series
Contact Rating3A AC220V3A AC220V5A AC220V
Control Distance≤1km≤1–2km≤1km
Montaggio8‑pin base8‑pin base / rail35Guida DIN da mm
IndicatoreOpzionale (B/C type)StandardStandard
Anti-interferenceDi baseIndustrialIndustrial
AmbienteCivil / light industryIndustrial / humidAutomation systems

Prev:

Prossimo:

Lasciare una risposta