It is not a contactor, but a CHINT NJMC1 series impulse relay, a low-power consumption bistable control electrical device.
Model Explanation
NJMC1: Model code of CHINT impulse relay series
16: Rated contact capacity (16UN)
1P: 1 pole (single contact)
Core Parameters
| Category | Details |
| Product Type | Mechanical bistable impulse relay |
| Contact Parameters | Resistive load: 16A/250VAC; Maximum switching power: 4000VA (AC) / 448W (DC) |
| Coil Parameters | Voltage range: AC 12~380V / DC 6~220V; Triggered only by pulse signal (no continuous power supply required) |
| Service Life | Vita elettrica: 1×10⁵ operations; Vita meccanica: 2×10⁶ operations |
| Ambiente operativo | Temperatura: -25℃~+55℃; Grado di inquinamento: 1; Overvoltage category: Ⅱ |
| Mounting Method | 35mm DIN rail mounting |
| Dimensioni | 86×70×18mm |
Caratteristiche principali
Bistable Design: The contact state is switched by pulse signal (duration 50ms~1s). No continuous power supply is needed after switching, featuring ultra-low power consumption (different from the continuous power supply of ordinary relays).
High Compatibility: Complete AC/DC coil voltage specifications, suitable for different control circuits.
Miniaturization: Dimensioni compatte, suitable for dense control cabinet layout.
Applicazioni tipiche
Suitable for low-power on-off control scenarios, ad esempio:
– Energy-saving control of lighting circuits
– Switching of small loads (per esempio., solenoid valves, indicator lights)
– Signal-triggered on-off circuits in automation equipment
Full Specification Selection Table of CHINT NJMC1 Series Impulse Relays
(Nota: All series adopt mechanical bistable design, triggered only by pulse signal, no continuous power supply required after switching, low power consumption and energy saving)
| Modello | Number of Poles | Corrente nominale | Contact Configuration | Optional Coil Voltage Specifications | Rated Load (Resistive) | Mounting Method | Dimensioni (L×W×H) | Peso (approx.) |
| NJMC1-10/1P | 1P | 10UN | 1 changeover contact (1CO) | AC: 12V/24V/110V/220V/380V; DC: 6V/12V/24V/48V/110V/220V | AC 10A/250V (3000VA); DC 10A/24V (240W) | 35mm DIN Rail | 86×70×18mm | 85g |
| NJMC1-10/2P | 2P | 10UN | 2 changeover contacts (2CO) | Same as 1P specification | Same as 1P specification | 35mm DIN Rail | 86×70×36mm | 150g |
| NJMC1-10/3P | 3P | 10UN | 3 changeover contacts (3CO) | Same as 1P specification | Same as 1P specification | 35mm DIN Rail | 86×70×54mm | 210g |
| NJMC1-10/4P | 4P | 10UN | 4 changeover contacts (4CO) | Same as 1P specification | Same as 1P specification | 35mm DIN Rail | 86×70×72mm | 270g |
| NJMC1-16/1P | 1P | 16UN | 1 changeover contact (1CO) | AC: 12V/24V/110V/220V/380V; DC: 6V/12V/24V/48V/110V/220V | AC 16A/250V (4000VA); DC 16A/24V (384W) | 35mm DIN Rail | 86×70×18mm | 90g |
| NJMC1-16/2P | 2P | 16UN | 2 changeover contacts (2CO) | Same as 1P specification | Same as 1P specification | 35mm DIN Rail | 86×70×36mm | 160g |
| NJMC1-16/3P | 3P | 16UN | 3 changeover contacts (3CO) | Same as 1P specification | Same as 1P specification | 35mm DIN Rail | 86×70×54mm | 225g |
| NJMC1-16/4P | 4P | 16UN | 4 changeover contacts (4CO) | Same as 1P specification | Same as 1P specification | 35mm DIN Rail | 86×70×72mm | 290g |
| NJMC1-20/1P | 1P | 20UN | 1 changeover contact (1CO) | AC: 12V/24V/110V/220V/380V; DC: 6V/12V/24V/48V/110V/220V | AC 20A/250V (5000VA); DC 20A/24V (480W) | 35mm DIN Rail | 86×70×18mm | 95g |
| NJMC1-20/2P | 2P | 20UN | 2 changeover contacts (2CO) | Same as 1P specification | Same as 1P specification | 35mm DIN Rail | 86×70×36mm | 170g |
| NJMC1-20/3P | 3P | 20UN | 3 changeover contacts (3CO) | Same as 1P specification | Same as 1P specification | 35mm DIN Rail | 86×70×54mm | 240g |
| NJMC1-20/4P | 4P | 20UN | 4 changeover contacts (4CO) | Same as 1P specification | Same as 1P specification | 35mm DIN Rail | 86×70×72mm | 310g |
| NJMC1-25/1P | 1P | 25UN | 1 changeover contact (1CO) | AC: 12V/24V/110V/220V/380V; DC: 6V/12V/24V/48V/110V/220V | AC 25A/250V (6250VA); DC 25A/24V (600W) | 35mm DIN Rail | 86×70×18mm | 100g |
| NJMC1-25/2P | 2P | 25UN | 2 changeover contacts (2CO) | Same as 1P specification | Same as 1P specification | 35mm DIN Rail | 86×70×36mm | 180g |
| NJMC1-25/3P | 3P | 25UN | 3 changeover contacts (3CO) | Same as 1P specification | Same as 1P specification | 35mm DIN Rail | 86×70×54mm | 255g |
| NJMC1-25/4P | 4P | 25UN | 4 changeover contacts (4CO) | Same as 1P specification | Same as 1P specification | 35mm DIN Rail | 86×70×72mm | 330g |
Key Selection Instructions (Essential for Sales/Quotation Scenarios)
- Core Selection Dimensions:
– Number of Poles (1P~4P): Select according to the number of control circuits (per esempio., 1P for single-circuit lighting, 3P for three-phase equipment);
– Corrente nominale (10A/16A/20A/25A): Load current ≤ 80% of rated current (per esempio., it is recommended that the load of 16A model ≤ 12.8A);
– Tensione della bobina: Must match the customer’s control circuit voltage (AC 220V and DC 24V are the most commonly used specifications, which can be recommended first in quotation).
- Load Compatibility:
– Suitable for resistive loads (illuminazione, forni a resistenza) and low-power inductive loads (small solenoid valves, tifosi). For capacitive loads, derating by 50% è obbligatorio.