DVP16SP11T is a 16‑point slim digital mixed I/O expansion module of Delta DVP‑S series, configured as 8 DI (Ingresso digitale) + 8 FARE (Uscita digitale, NPN sinking transistor). It is specially designed for expanding I/O points of Delta DVP‑S series PLC main units, suitable for small automation systems with limited space, and supports high‑speed pulse ...

  • Dettagli del prodotto

DVP16SP11T is a 16‑point slim digital mixed I/O expansion module of Delta DVP‑S series, configured as 8 DI (Ingresso digitale) + 8 FARE (Uscita digitale, NPN sinking transistor).

It is specially designed for expanding I/O points of Delta DVP‑S series PLC main units, suitable for small automation systems with limited space, and supports high‑speed pulse output and counting functions.

  1. Spiegazione del modello & Posizionamento di base
Parte del modelloSenso
DVPDelta PLC product series code
16Total I/O points: 16 punti (8 ingresso + 8 produzione)
SPMixed I/O type (S = Slim, P = Mixed input/output)
11Codice della versione, tipo standard
TTipo di uscita: Transistor output (NPN sinking)

Posizionamento del prodotto:

Compact I/O expansion module for DVP‑S series PLC, used to expand the digital control capability of the main unit.

Especially suitable for space‑limited applications such as small mechanical equipment, linee di produzione automatizzate, and building control systems.

It can be seamlessly connected with DVP‑S series main units (DVP12SA11T, DVP16SA11T, ecc.).

  1. Parametri tecnici chiave
ArticoloSpecifica
Caratteristiche di ingresso
Input points8 punti (DI)
Input typeSinking / sourcing selectable (default sinking)
Rated input voltage24VCC (±10%)
Input current7mA per point (ON state)
Tempo di risposta1SM (standard), configurable to 0.1ms (high‑speed mode)
Input impedanceca. 3.3
Caratteristiche di uscita
Output points8 punti (FARE)
Tipo di uscitaTransistor (NPN sinking)
Rated output voltage24VCC (±10%)
Rated current per point0.5UN (continuous), 1UN (peak, 0.5S)
Massimo. total current4UN (all outputs active)
High‑speed pulse output2 points up to 10kHz (specific channels)
Elettrico & Caratteristiche fisiche
Fabbisogno di energia24VCC, module power consumption approx. 80mA
Resistenza di isolamento≥100MΩ (500VCC)
Dielectric strength2kV AC (between input/output/power, 1 min)
Temperatura operativa0℃ ~ +55 ℃
Temperatura di conservazione-25℃ ~ +70 ℃
Dimensioni25mm × 76mm × 102mm (design sottile, consente di risparmiare spazio nell'armadio)
Montaggio35Montaggio su guida DIN standard da mm
  1. Caratteristiche & Structural Advantages
  2. Ultra‑Slim Compact Design

Only 25mm wide, saves about 50% installation space compared with traditional modules, ideal for high‑density I/O control panels.

Gapless side‑by‑side assembly for maximum space utilization.

Clip‑on connection, no screws required, facile installazione.

  1. Flexible I/O Configuration

8 ingresso + 8 output mixed design to meet I/O requirements of most small control systems.

Input supports sinking/sourcing switching, compatible with NPN/PNP sensors.

Fast transistor response (≤10μs), suitable for high‑frequency switching control.

  1. High‑Speed Control Capability

2 high‑speed pulse outputs up to 10kHz for simple positioning (per esempio., stepper motor drive).

4 high‑speed counter inputs up to 20kHz for speed measurement, part counting, ecc.

Supports interrupt input for fast response to external emergency signals.

  1. Reliable Electrical Performance

Enhanced anti‑interference design, complies with industrial EMC standards (EN 61000‑6‑2 / EN 61000‑6‑4).

Output short‑circuit protection to prevent module damage.

Built‑in surge suppression circuit to protect output devices from back EMF of inductive loads.

  1. Campi di applicazione
FieldApplicazioni tipicheVantaggi
Small MachineryMacchine per l'imballaggio, labeling machines, small machine toolsSlim size, high‑speed I/O for precise control
Automated LinesTrasportatori, sistemi di smistamento, assembly stationsMixed I/O for various sensors & actuators
Automazione degli edificiLighting control, access control, HVACBassa potenza, suitable for long‑time operation
Smart AgricultureIrrigazione, greenhouse control, feed processingStrong anti‑interference, adapts to harsh environments
New Energy EquipmentSmall PV inverters, sistemi di accumulo dell’energiaFast response, supports high‑frequency switching
  1. Comparison of Similar Modules in DVP‑S Series
ModelloConfigurazione I/OTipo di uscitaCaratteristiche principaliApplicazione
DVP16SP11T8DI + 8FARETransistor (NPN)16‑point mixed, high‑speed pulse outputFull control of small equipment
DVP16SP11R8DI + 8FARERelè16‑point mixed, AC/DC compatibleContactors, solenoids, carichi induttivi
DVP08SP11T4DI + 4FARETransistor (NPN)8‑point mixed, dimensione più piccolaMicro‑equipment control
DVP08SP11R4DI + 4FARERelè8‑point mixed, economicoSimple control circuits
DVP08SN11T0DI + 8FARETransistor (NPN)Output only expansionAdditional output points only
DVP08SM11N8DI + 0FAREIngresso digitaleInput only expansionAdditional input points only
  1. Connessione & Note operative
  2. System Connection

Connect to DVP‑S series main unit via left expansion port; fino a 8 modules can be expanded.

Modules connected by dedicated expansion cable, no extra configuration needed.

Massimo. I/O points after expansion: main unit points + expansion points (massimo. 128 punti).

  1. Wiring Rules

Input wiring: 24VDC supply, COM to 0V, signal terminal to sensor signal.

Output wiring: 24VDC supply, COM to +24V, signal terminal to load negative (sinking output).

4 outputs share one COM terminal; 2 COM groups (4 points each) for grouped control.

  1. High‑Speed Function Configuration

High‑speed pulse output: Y0/Y1 up to 10kHz for stepper or servo motors.

High‑speed counter: X0–X3 up to 20kHz, 1‑phase / 2‑phase configurable.

Configured via programming software (DVPSoft), no extra hardware required.

  1. Protection Measures

Surge suppressor on input side to resist external interference.

Freewheeling diode for inductive loads to protect transistors.

Avoid output short‑circuit; massimo. 0.5A continuous per output.

  1. Selezione & Sostituzione
  2. Linee guida per la selezione

Tipo di uscita: Transistor for high‑frequency, low inductance; Relay for AC/DC, alta potenza.

I/O points: Choose 8‑point or 16‑point based on controlled devices.

Space: Slim modules preferred for narrow control cabinets.

High‑speed functions: Select T‑type for pulse output or high‑speed counting.

  1. Opzioni di sostituzione
RequisitoSostituzione consigliataVantaggio
Relay output neededDVP16SP11RAC/DC load compatible, long contact life
Fewer I/O pointsDVP08SP11TSmaller size, costo inferiore
Higher pulse frequencyBuilt‑in high‑speed channels of DVP‑S main unit (up to 100kHz)Higher precision positioning
Cross‑series replacementDVP‑ES2 series expansion (DVP08SP11T‑ES2)Compatible with DVP‑ES2, richer functions
  1. Typical Application Examples
  2. Small Packaging Machine:

8 inputs (material position, product detection, safety door),

8 outputs (feeding motor, sealer, cutter, conveyor),

high‑speed pulse for feeding positioning.

  1. Automated Assembly Line:

Ingressi (part position, fixture status),

Uscite (cylinders, motori, indicators),

high‑speed counting for production statistics.

  1. Building Lighting Control:

Ingressi (motion sensor, light sensor, manual switch),

Uscite (circuiti di illuminazione, HVAC fans),

energy‑saving control.

Packing Specification: 1 pz/scatola, 10 pezzi/cartone

Differenze fondamentali: Delta DVP16SP11T vs. Similar Modules

At a Glance:

Delta DVP16SP11T features ultra‑slim 25mm width, conveniente, seamless compatibility with DVP‑S series.

Siemens / Mitsubishi / Omron excel in industrial ecosystem and high‑end functions.

Xinje focuses on cost‑effective domestic replacement.

  1. Main Competitors & Basic Comparison
ArticoloDelta DVP16SP11TSiemens S7‑200 SMART EM AT02Mitsubishi FX5U‑16EYT/ESOmron CP1W‑16ETXinje XC3‑16EYT
PosizionamentoDVP‑S slim mixed I/OS7‑200 SMART compact expansionFX5U/iQ‑F high‑performanceCP1H/CP1L general expansionXC3 domestic compact
I/O Config8DI + 8FARE16DI + 16FARE16DI + 16FARE16DI + 16FARE16DI + 16FARE
OutputTransistor NPN sinkingTransistor (sink/source selectable)Transistor (sink/source selectable)Transistor (sink/source selectable)Affondamento del transistor
Tensione in ingresso24VCC (±10%)24VCC24VCC24VCC24VCC
Larghezza25mm (thinnest)ca. 30mmca. 28mmca. 27mmca. 26mm
Compatible CPUDVP‑S series onlyS7‑200 SMART onlyFX5U / FX3U seriesCP1H / CP1L / CP1EXC3 / XC2 series only
Massimo. EspansioneFino a 8 moduliFino a 8 moduliFino a 16 moduliFino a 8 moduliFino a 7 moduli
Package1 pz/scatola, 10 pezzi/cartone1 pz/scatola1 pz/scatola1 pz/scatola1 pz/scatola
  1. Key Functional & Performance Differences

2.1 High‑Speed Control (Differenza fondamentale)

ArticoloDelta DVP16SP11TSiemens EM AT02Mitsubishi FX5U‑16EYTOmron CP1W‑16ETXinje XC3‑16EYT
Pulse Output2 points @10kHz2 points @≈2kHz4 axes @200kHz (built‑in)4 points @100kHz2 points @10kHz
High‑Speed Counter4 points @20kHz6 points @100kHz6 points @200kHz4 points @200kHz4 points @10kHz
Input Response0.1SM (ad alta velocità)1SM0.2SM0.1SM0.5SM
StrengthBasic high‑speed, small positioningStable, low‑speed logicUltra‑high frequency, precision positioningStrong counting, high anti‑interferenceCosto più basso, basic control

2.2 Installazione & Cablaggio

ArticoloDelta DVP16SP11TSiemens EM AT02Mitsubishi FX5U‑16EYTOmron CP1W‑16ETXinje XC3‑16EYT
MontaggioClip‑on DIN rail, gaplessVite + Guida DINTerminal block, collegareGuida DIN + viteClip‑on DIN rail
terminaleSpring clamp, tool‑freeTerminale a viteSpring clampTerminale a viteSpring clamp
SpaceUltra‑compactStandard compactStandard compactStandard compactStandard compact

2.3 Software & Comunicazione

ArticoloDelta DVP16SP11TSiemens EM AT02Mitsubishi FX5U‑16EYTOmron CP1W‑16ETXinje XC3‑16EYT
SoftwareDVPSoft (easy to use)TIA Portal (powerful)GX funziona3 (FX compatible)CX‑Programmer (stabile)XCPPro (user‑friendly)
ComunicazioneMODBUS RTU/TCP, CANopenPROFINET, MODBUS TCPCC‑Link, Ethernet/IP, MODBUSMODBUS RTU/TCP, HostLinkMODBUS RTU/TCP
EcosystemSeamless with Delta servo/HMIFull Siemens integrationPerfect with Mitsubishi servo/inverterHigh compatibility with Omron devicesGood with domestic equipment
DiagnosisDi baseComprehensiveDetailed, monitoraggio remotoPrecise, fast fault locationDi base
  1. Application‑Based Selection Suggestions
  2. Best for Delta DVP16SP11T

Extremely limited space: 25mm ultra‑slim for compact panels.

DVP‑S series system: Direct expansion without adaptation.

Conveniente + basic high‑speed: 10kHz pulse / 20kHz counter for small packaging, labeling, trasportatori.

Fast delivery: DVPSoft is easy to learn, short commissioning time for OEMs.

  1. Best for Siemens S7‑200 SMART EM AT02

Large/complex lines: PROFINET, full diagnosis, multi‑device coordination.

Siemens ecosystem: PLC, servo, HMI unified.

Alta affidabilità: Automobilistico, chimico, trattamento dell'acqua.

  1. Best for Mitsubishi FX5U‑16EYT/ES

Posizionamento di precisione: 200kHz pulse, multi‑axis interpolation for CNC, precision assembly.

Mid‑to‑high automation: Built‑in Ethernet, analogico, CC‑Link.

Long‑term support: Mature FX ecosystem.

  1. Best for Omron CP1W‑16ET

Ambienti difficili: Strong anti‑interference, polvere, electromagnetic noise.

Counting & inspection: High‑speed counting for packaging, sorting.

Omron sensor/HMI system.

  1. Best for Xinje XC3‑16EYT

Domestic replacement / tight budget: Lower cost than Delta.

Beginner development: XCPPro easy to use.

Domestic equipment matching: Elevato rapporto costo-prestazioni.

  1. Cross‑Brand Replacement Notes
  2. I/O point match: Delta is 8DI+8DO; Siemens/Mitsubishi/Omron are 16DI+16DO per module. Adjust I/O layout.
  3. Output polarity: Delta is NPN sinking; others often support sink/source. Confirm COM wiring.
  4. High‑speed downgrade: If replacing from Mitsubishi/Siemens to Delta, reduce pulse/counter speed and reprogram.
  5. Comunicazione: Delta uses mainly MODBUS; Siemens/Mitsubishi support industrial Ethernet. Adjust protocol settings.