DVP28SV11T2 DVP: Delta PLC series code 28: Punti I/O totali 28 punti (16DI+12DO) SV: High-performance main unit of SV series; SV2 denotes second-generation hardware (suffix T2 = SV2) 11: DC24V power supply T: Transistor output NPN (tipo di lavandino) 2: Second-generation SV2 hardware version, supporting left-side high-speed expansion port Core Hardware Specifications Item Parameters Power Supply ...

  • Dettagli del prodotto

DVP28SV11T2

PAD: Delta PLC codice di serie

28: Punti I/O totali 28 punti (16DI+12DO)

SV: High-performance main unit of SV series; SV2 denotes second-generation hardware (suffix T2 = SV2)

11: DC24V power supply

T: Transistor output NPN (tipo di lavandino)

2: Second-generation SV2 hardware version, supporting left-side high-speed expansion port

Specifiche hardware principali

ArticoloParametri
Alimentazione elettricaDC24V, reverse‑polarity protection, maximum inrush current 2.2A
Ingresso digitale DI16‑point DC24V, source/sink compatible
Uscita digitale DO12‑point NPN transistor output
Capacità del programma30K Passaggi (SV2 second generation), data register 12K Word
High‑speed Counter8‑channel; X0/X1/X4/X5 max. 200kHz; remaining X terminals 10kHz
Uscita a impulsiY0‑Y3 max. 200kHz (4‑axis independent pulse output); supports linear/circular interpolation
ComunicazioneCOM1: Mini‑DIN8 RS232; COM2: RS485; Modbus RTU/ASCII master/slave
Capacità di espansioneRight‑side for standard S‑series modules; dedicated left‑side high‑speed expansion port; maximum total I/O 512 punti
MontaggioMontaggio su guida DIN35; Dimensions W70 × H90 × D109.4 mm
Temperatura operativa0‑55℃

Software

Software di programmazione: WPLSoft / ISPSoft, with COMMGR communication manager

Supported features: 4-livello di protezione tramite password, backup del programma, battery-free real-time clock, 16-channel external interrupt.

Applicazioni tipiche

Posizionamento dei servi, XY manipulators, etichettatrici, macchine confezionatrici, cutting equipment, macchine tessili, and other equipment requiring multi-axis pulse motion control.

Distinction of Models in the Same Series

DVP28SV11T: First-generation SV, 16K-step program, without left-side high-speed expansion port

DVP28SV11T2: SV2 second-generation, 30K-step program, with left-side high-speed expansion port

DVP28SV11R2: Relay-output version

DVP28SV11S2: PNP transistor-output version

Second-hand Inspection Checklist

  1. Prova di accensione: POWER indicator steady ON; check status of RUN/ERROR/BAT-LOW indicators; low-battery alarm.
  2. I/O test: Force ON/OFF to verify all input and output points.
  3. High-speed pulse test: Test Y0-Y3 pulse output up to 200kHz; verify high-speed counter reception on X0/X1.
  4. Prova di comunicazione: Program upload/download via RS232 and RS485; Modbus read-write test.
  5. Expansion port inspection: Check left-side and right-side expansion connectors for oxidation and intact pins.

Alternative References

Delta native alternatives: DVP28SV11S2 (PNP); DVP28SE211T (SE2 new generation, with Ethernet port)

Alternativa domestica: Inovance H2U-1616MT-XP (200impulso kHz, 4-asse)

Programming Software for Delta DVP28SV11T2 (SV2 Series)

This unit belongs to second-generation DVP-SV2 PLC; two official software packages are supported:

  1. ISPSoft (Consigliato per nuovi progetti)

Ultima versione: V3.24 and above

Mandatory companion: COMMGR communication manager, handles serial/USB communication connection

Supported IEC61131-3 languages: LD (Diagramma a scala), ST (Structured Text), FBD (Diagramma a blocchi funzione), SFC (Grafico delle funzioni sequenziali); full SV2 motion instructions, interpolazione, high-speed positioning; modular POU programming, simulazione, monitoraggio in linea, firmware upgrade.

sistema operativo: Win7/10/11 (64-morso)

  1. WPLSoft (Legacy software for existing project maintenance)

Versione: V2.52, traditional Delta DVP programming software, mainly supports ladder diagram and instruction list, no Structured Text support

Suitable for reading backup programs from legacy equipment and simple logic; inferior to ISPSoft for complex motion-control functions.

⚠️ Nota: DIADesigner does NOT support DVP28SV11T2. DIADesigner is for high-end SV3, AS/AH series PLCs.

Programming Cables

For the front-panel Mini-DIN8 RS232 port of DVP28SV11T2:

  1. Delta original USB-DVP programming cable (USB to Mini-DIN8)
  2. RS232-to-Mini-DIN8 cable is also acceptable; program download is available via COM2 RS485 as well.

Software Selection Guidance

Posizionamento dei servi, interpolazione circolare, processi complessi: ISPSoft + COMMGR

Legacy equipment with WPLSoft-format project files: Maintain with WPLSoft.

Communication Protocols for Delta DVP28SV11T2 (SV2)

On-board hardware: COM1-RS232 (Mini-DIN8), COM2-RS485 terminal block. No native Ethernet or CANopen; fieldbus functions require left-side expansion modules.

Protocols Supported by On-board Serial Ports

  1. ModBus RTU / Modbus ASCII (Il più utilizzato)

Available on COM1(RS232) and COM2(RS485); supports both Master and Slave modes

Max baud rate 115200bps; configurable data bits, parità, bit di arresto

Applicazioni: Connect to HMI, inverter, servi, meters and third-party Modbus devices.

  1. Delta proprietary protocol (PLCLink)

Data exchange among multiple DVP-SV2/SA2/SS2 PLCs via RS485 networking.

  1. Program download protocol

COM1 RS232: ISPSoft/WPLSoft program upload/download, monitoraggio in linea

Program download and monitoring are also supported over COM2 RS485.

Factory default serial parameters: 9600, 7, E, 1 (9600bps, 7-data-bit, even parity, 1 fermati un po')

Additional Fieldbus Protocols via Left-side High-speed Expansion Modules (Hardware add-on only, not built-in)

Use the dedicated left-side high-speed slot with corresponding communication modules:

DVPCOPM-SL: CANopen master module, CANopen DS301 compliant, for CANopen servo/drive connection

DVPNET-SL: Modulo Ethernet, supports Modbus-TCP (Master/Slave)

DVPDP-SL: Profibus-DP slave module

DVPDNM-SL: DeviceNet module

Port Function Summary

PortaHardwareFunzioni
COM1RS232 Mini‑DIN8Scaricamento del programma, Modbus RTU/ASCII Slave; cannot act as Modbus Master
COM2RS485 terminal blockModbus Master/Slave, PLCLink, download del programma
Left‑side Expansion PortDedicated high‑speed slotOptional CANopen, Ethernet, Profibus‑DP and other bus modules

Insidie ​​​​comuni

  1. DVP28SV11T2 has no built-in Ethernet or CAN interface. Expansion modules must be purchased separately.
  2. COM1(RS232) can only operate as Modbus Slave. Modbus Master function is exclusively for COM2(RS485).
  3. PLCLink works only between Delta DVP-series PLCs; incompatible with third-party hardware.

Complete Installation Guide for Delta DVP28SV11T2 (ISPSoft + COMMGR)

ISPSoft is preferred for DVP28SV11T2(SV2). COMMGR is mandatory for communication; program download will fail without it.

Supported OS: Win10 / Win11 64-bit. Download installation packages from Delta Industrial Automation official website.

Preparazione pre-installazione

  1. Uninstall old versions of ISPSoft and COMMGR; mixed versions cause communication failures.
  2. Right-click installer → Run as administrator (critical for Win11; avoids installation errors and driver failure).
  3. Temporarily disable antivirus / Windows Defender to prevent component interception.
  4. Ensure .NET Framework4.5 is installed (included in modern Windows; download from Microsoft if missing).

Two Installation Procedures

Method A: COMMGR bundled inside ISPSoft installer (Raccomandato)

  1. Unzip ISPSoft archive and run Setup.exe.
  2. Select Chinese language, follow on-screen prompts; keep the [COMMGR] component checked, do not uncheck it.
  3. Customize install path; avoid Chinese-character directories on C drive (per esempio. D:\Delta\ISPSoft).
  4. Complete installation and reboot PC as prompted.

⚠️ If COMMGR was unchecked during setup, download and install COMMGR separately.

Method B: Separate installation

  1. Install COMMGR (Communication Manager) Primo.
  2. Install ISPSoft programming software afterwards.

Post-installation Configuration (Program editing ≠ download capability; COMMGR channel setup is required)

  1. Close ISPSoft first, launch COMMGR from start menu (icon appears in system tray).
  2. Click [Aggiungere]

Driver name: English characters only, per esempio. DVP_SV2 (No Chinese characters or spaces)

Tipo di comunicazione:

Delta USB programming cable: Select USB

USB-to-RS232/485 adapter: Select Serial Port, confirm COM number in Windows Device Manager.

  1. Parameters matching PLC factory defaults: 9600, 7, E, 1, Station No.1
  2. Confirm configuration, select this channel and click [Inizio]. Status START means channel is ready.
  3. Open ISPSoft, create new project, seleziona il modello: DVP-SV2 → DVP28SV11T2
  4. Menu [Utensili] → [Impostazioni di comunicazione], select the pre-configured COMMGR channel to go online, upload or download programs.

Alternative Legacy Software WPLSoft (For maintenance-only)

Non consigliato per nuovi progetti; lacks ST language and advanced motion interpolation instructions.

  1. Install WPLSoft V2.53, esegui come amministratore.
  2. WPLSoft also relies on COMMGR; communication configuration follows identical steps above.

Risoluzione dei problemi comuni

  1. Gray online button: COMMGR is not running, channel status is not START.
  2. COM port not found: Install driver for USB-to-serial chip (CH340 / FT232); no yellow exclamation marks in Device Manager.
  3. Win11 installation errors: Always run as administrator, avoid Chinese-character install paths, disable security software temporarily.
  4. Communication errors: Double-check baud rate, parity setting and PLC station number. SV2 factory setting: 9600-7-E-1

Hint for New DVP28SV11T2 Project

ISPSoft New Project → Series DVP-SV2 → select DVP28SV11T2. The software automatically applies hardware parameters: 30K-step program capacity, 4-axis 200kHz pulse output.