Contattore Schneider LC1E630M7N

LC1E630M7N is a 3‑pole AC contactor from Schneider EasyPact TVS (formerly TeSys E) serie. The breakdown is as follows: Part Meaning LC1 Basic contactor series identifier E EasyPact TVS (economico) serie, mainly for China market 630 Rated operational current 630A (AC‑3 at 440V) M Coil voltage code: 220V e 7 Coil supports 50/60Hz N Domestic version (performance is ...

  • Dettagli del prodotto

LC1E630M7N is a 3‑pole AC contactor from Schneider EasyPact TVS (formerly TeSys E) serie. The breakdown is as follows:

ParteSenso
LC1Basic contactor series identifier
EEasyPact TVS (economico) serie, mainly for China market
630Rated operational current 630A (AC‑3 at 440V)
MCodice tensione bobina: 220V e
7Coil supports 50/60Hz
NDomestic version (performance is essentially the same as LC1E630M7)
  1. Specifiche tecniche principali
ArticoloValoreNote
Poli3P (3 NO)Contatti principali: 3 NO
Corrente operativa nominale630UNAC‑3, 440V, 50/60Hz
Tensione operativa nominale≤ 690V ACMax main circuit voltage
Control coil220V e, 50/60HzSpunto: ca. 1600VA, Presa: ca. 200VA
Categoria di utilizzoAC‑3For starting, running, stopping three‑phase induction motors
Mechanical enduranceca. 10 milioni di operazioniStandard conditions
Electrical enduranceca. 100,000 operazioniAC‑3 at 630A
Montaggio35mm DIN rail or bolt fixingW≈200mm, H≈220mm, D≈100mm
Contatti ausiliariCan add 2 O 4 moduliNot included; sold separately
  1. Applicazioni
  2. Control of medium and large three‑phase induction motors (ca. 315kW at 440V)
  3. Main circuit control in industrial automation lines
  4. Power equipment control in building electrical and HVAC systems
  5. Heavy‑duty loads requiring frequent starting and stopping
  6. Can combine with LRE series thermal relays (per esempio., LRE630N) as a starter for motor overload protection
  7. Caratteristiche principali
  8. Design ad alta affidabilità: Optimized arc extinguishing system for harsh industrial environments
  9. Wide voltage compatibility: Coil operates stably at 85%–110% of rated voltage
  10. Progettazione modulare: Supports auxiliary contacts, interblocchi meccanici, soppressori di sovratensione, ecc.
  11. Certificazioni: Complies with IEC 60947‑4‑1, GB 14048.4, ecc.
  12. Installazione & Manutenzione
  13. Liquidazione: ≥50mm top/bottom, ≥20mm left/right for cooling
  14. Cablaggio: Main circuit recommended ≥185mm² copper cable; torque approx. 55N·m
  15. Maintenance interval: Every 6 months in normal environment; 3 months in dusty areas
  16. Risoluzione dei problemi: Check coil voltage if no pull‑in; check load and operating frequency if contact erosion
  17. Replacements & Compatible Products
  18. Schneider direct replacements:

LC1N630M7N: Official successor to LC1E series, same economic positioning

LC1D620M7C: Standard contactor, 620UN, more stable performance

LC1F630M7: High‑performance series for severe duty

  1. Cross‑brand references:

ABB: AF630‑30‑22 (630UN, 220V e)

Siemens: 3RT2076‑6AP36 (630UN, 220V e)

CINT: CJX2‑630S (630UN, 220V e)

  1. Important Notes
  2. Some LC1E models are discontinued; LC1N series is recommended for new projects
  3. Verificare il tipo di carico (resistive/inductive), operation frequency, and environment during selection
  4. Match thermal relay rating to motor rating (630A typically controls ~315kW motors)

Better Schneider Contactors Than LC1E630M7N

Contactors superior to LC1E630M7N fall into three categories:

Sostituzione dell'aggiornamento (LC1N630M7N / D3N),

Standard Enhanced (LC1D620M7C / LC1D630M7C),

High‑Performance Premium (LC1F630M7 / LC1G630M7).

Raccomandazione:

New projects → LC1N630M7N

Severe applications → LC1D620/630

Frequent starts / high altitude / special certs → LC1F / LC1G

  1. Posizionamento & Limitations of LC1E630M7N

LC1E630M7N belongs to Schneider EasyPact TVS (economico) series – a domestic 3‑pole contactor, 630UN (AC‑3, 440V), coil 220V AC 50/60Hz.

Limitations:

Some ratings discontinued (06A–95A phased out)

Electrical endurance approx. 100,000 operazioni (AC‑3), lower than standard/high‑performance models

Narrower ambient temperature range; limited special certifications (marine, railway)

  1. Graded Recommendations

2.1 Sostituzione dell'aggiornamento: LC1N630M7N (EasyPact D3N)

Official replacement for LC1E, improved economic version.

VantaggioImprovement
PrestazioneElectrical endurance ↑ ~20%; mechanical endurance 12 milioni
DesignMore complete modularity, better accessory compatibility
AffidabilitàUpgraded arc chamber for harsh environments
InstallazioneOptimized terminals, stable torque, easier maintenance
CompatibilitàSame footprint as LC1E for drop‑in replacement

2.2 Standard Enhanced: LC1D620M7C / LC1D630M7C (TeSys D)

Schneider’s mainstream standard series, balanced performance and cost.

Key BenefitSpecifica
Higher durabilityElectrical endurance 150,000 operazioni (AC‑3); mechanical 15 milioni
Wide environment‑25°C to +70°C; altitude ≤4000m (vs ≤2000m for LC1E)
Special certsSupports marine (DNV), railway, ecc.
Safety features1NO + 1NC standard; mirror contacts available
Rating rangeLC1D620 (620UN), LC1D630 (630UN)

2.3 High‑Performance Premium: LC1F630M7 (TeSys F) / LC1G630M7 (TeSysGiga)

For severe duty: frequent starts, heavy loads, extreme environments.

SerieKey AdvantagesApplicazioni
TeSys F (LC1F)• Electrical endurance: 200,000 operazioni (AC‑3)Metallurgy, minerario, large compressors
• Higher current margin (630A → short‑time 700A)Frequent operation (≥1200 operations/h)
• Lower holding power (≈180VA)
TeSysGiga (LC1G)• Up to 300,000 operazioni (AC‑3)Offshore platforms, high altitude (>4000M), ‑40°C
• Rated insulation voltage 1000V, stronger breaking capacityCritical high‑reliability equipment
• IP20 standard, some IP65
  1. Core Specification Comparison
ArticoloLC1E630M7NLC1N630M7NLC1D620M7CLC1F630M7
Corrente nominale (AC‑3, 440V)630UN630UN620UN630UN
Electrical endurance (AC‑3)100k120k150k200k
Mechanical endurance10M12M15M20M
Coil holding power200VA190VA185VA180VA
Ambient temp‑5°C ~ +60°C‑10°C ~ +65°C‑25°C ~ +70°C‑30°C ~ +75°C
CertificazioniDi baseDi base + partial industrialFull industrialFull + marine
Price levelEconomicoEconomico +10%Standard +30%Premio +50%

Nota: k = 1000 operazioni; M = 1 milioni di operazioni

  1. Selection Advice
  2. New projects first choice: LC1N630M7N – perfect drop‑in replacement, better performance, affordable
  3. General industrial use: LC1D620M7C – higher reliability for automation and HVAC
  4. Severe duty: LC1F630M7 – frequent starts (>600/H), heavy load, high temperature
  5. Critical/extreme environment: LC1G630M7 – offshore, high altitude, low temperature, maximum reliability
  6. Important Warnings
  7. Although LC1E is not fully discontinued, Schneider officially recommends LC1N for better supply continuity
  8. 630A contactors typically control ~315kW (440V) three‑phase motors; match load, duty cycle, and environment
  9. Use matched thermal relays: LRE630N (LC1E/LC1N) or LRD630 (LC1D/LC1F)