LS EBS203C-200A-3P MCCB - Contattore,interruttore automatico,inverter solare,contatore elettrico,batterie solari

Wechat: +86-13184948252 Whatsapp: 0086-13811255435 E-mail: kent@bestcontactor.com

Di Contatto |

LS EBS203C-200A-3P MCCB - Contattore,interruttore automatico,inverter solare,contatore elettrico,batterie solari

interruttore automatico/

LS EBS203C-200A-3P MCCB

EBS203C-200A-3P is a 3-pole, 200A rated earth-leakage molded case circuit breaker (MCCB/ELCB) manufactured by LS Electric (formerly LS Industrial Systems / LG Industrial Systems). It provides overcurrent, short-circuit and earth-leakage protection for three-phase electrical circuits. 📌 Model Explanation EBS203C: EBS series earth-leakage MCCB; 200 = frame size (DI), 3 = number of poles (3P), C ...

  • Dettagli del prodotto

EBS203C-200A-3P is a 3-pole, 200A rated earth-leakage interruttore automatico scatolato (MCCB/ELCB) manufactured by LS Electric (formerly LS Industrial Systems / LG Industrial Systems). It provides overcurrent, short-circuit and earth-leakage protection for three-phase electrical circuits.

📌 Model Explanation

EBS203C: EBS series earth-leakage MCCB; 200 = frame size (DI), 3 = number of poles (3P), C = thermal-magnetic trip type (TM).

200UN: Corrente operativa nominale 200 amperes.

3P: 3 poli, suitable for three-phase three-wire systems.

⚙️ Key Specifications

ArticoloSpecifica
Frame size (DI)200AF~399AF
Rated short‑circuit breaking capacity (terapia intensiva)85kA at AC220V; 37kA at AC400V
Tensione nominaleAC220/460V
Funzioni di protezioneSovraccarico, short‑circuit, earth leakage (100/200/500mA optional)
Tipo di viaggioViaggio magnetotermico (TM), instantaneous trip rating 12×In
Dimensioni (A×L×P)165×105×87mm
Pesoca. 1.2kg
CertificazioniCE, CCC

🛠️ Applications & Compatibilità

Typical applications: Distribuzione dell'energia industriale, production line equipment, power and lighting circuits, suitable for three-phase applications requiring reliable earth-leakage and short-circuit protection.

Raccomandazione: Can be used with Meta-MEC series products for selective protection and coordination to improve system reliability.

🔄 Equivalent & Series Models

Same series: EBS203C-100A/125A/150A/175A, EBS204C (4-palo), ecc.

Alternative references: ABB Tmax series, Schneider NSX series, Chint NM8L series and other equivalent earth-leakage MCCBs. Breaking capacity and mounting dimensions must be matched.

📦 Supply & Procurement

Marca: LS Elettrico (LSIS), originally manufactured in South Korea.

Purchasing channels: Authorized LS Electric distributors in China, industrial platform www.bestcontactor.com. Typical price is around one thousand RMB; negotiable for bulk orders.

The core difference between EBS203C-200A-3P and EBS203C-200A-4P (modello standard: EBS204C-200A) lies in the number of poles and the control method of the neutral (N) conductor, which directly affects wiring, protection scope and application scenarios.

  1. Structural Differences

EBS203C-200A-3P (3-palo)

Structure: 3 line/incoming terminals, controlling only L1, L2, L3 (three-phase live conductors).

Neutro (N): Does not pass through the breaker; directly connected.

Protezione: Fornisce sovraccarico, short-circuit and earth-leakage protection only for three-phase live conductors.

EBS204C-200A-4P (4-palo)

Structure: 4 line/incoming terminals, controlling L1, L2, L3 + N (three-phase live conductors + neutro).

Neutro (N): Passes through the breaker and switches simultaneously with phase conductors.

Protezione: Protects three-phase live conductors + neutral and can disconnect a faulty neutral line.

  1. Key Parameter Comparison
ArticoloEBS203C‑200A‑3PEBS204C‑200A‑4P
Telaio / Attuale200DI, 200UN, thermal‑magnetic type CIdentico
Potere di interruzione37kA at AC400V; 85kA at AC220VIdentico
Funzioni di protezioneSovraccarico, short‑circuit, earth leakageIdentico
Poli3P (3-polo)4P (4-polo)
Neutro (N)Bypasses the breakerSwitched with phases
LarghezzaNarrower (ca. 105mm)Wider (ca. 140mm)
Applicable systemThree‑phase three‑wire (IT, TN‑C without PEN)Three‑phase four‑wire (TN‑S, TN‑C‑S, TT)

III. Functional & Safety Differences

  1. Switching range

3P: Switches phases only. Neutral remains live, posing electric shock risk during maintenance.

4P: Switches both phases and neutral. Fully isolates power, safer and compliant with standards.

  1. Earth-leakage protection effectiveness

3P: Only detects three-phase current imbalance. Cannot protect against neutral faults (per esempio., neutral-to-earth short circuit).

4P: Monitors total current of four poles (L1-L2-L3-N), trips on neutral leakage for complete protection.

  1. Compatibilità del sistema

3P: Suitable for pure three-phase loads (motori, pompe) with no single-phase loads and no neutral in the panel.

4P: Suitable for mixed three-phase + single-phase systems (commerciale, industriale, building distribution); neutral disconnection required for safety.

  1. Guida alla selezione

Choose 3P (EBS203C):

Loads are pure three-phase motors, compressori, riscaldatori, ecc., with no 220V single-phase circuits.

Neutral in the distribution box does not pass through this breaker; space is limited.

Choose 4P (EBS204C):

System is TN-S / TN-C-S (separate N and PE conductors).

Circuit supplies single-phase loads (illuminazione, prese, circuiti di controllo); neutral must be switched.

Required by safety standards (manutenzione, earth-leakage protection, earthing systems).

Riepilogo

3P = space-saving, cost-effective → dedicated for three-phase power

4P = safer, more complete → required for mixed power distribution

LS Electric EBS Series Earth-Leakage MCCBs (BELCB): Elenco dei modelli & Cross-Brand Cross-Reference

  1. EBS Series Model System & Full List

Core features of EBS series: Earth-leakage molded case circuit breakers on LS Electric’s (formerly LS / LG Industrial Systems) Metasol platform, with built-in earth-leakage protection modules, fornendo tripla protezione contro il sovraccarico, short-circuit and residual current (earth leakage) for low-voltage distribution systems.

  1. Convenzione di denominazione dei modelli

EBS □□□ – □□□A – □P

EBS: Series code (earth-leakage MCCB)

1st digit: Frame size (5=50AF, 10=100AF, 20=200AF, 40=400AF)

2nd digit: Numero di poli (3=3P, 4=4P)

3rd letter: Classe del potere di interruzione (C=standard, S=high)

□□□A: Corrente nominale (In)

□P: Numero di poli (3P/4P, consistent with 2nd digit)

  1. Complete Model List by Frame Size

1) 50AF Frame (EBS53C / EBS54C)

PoliCorrente nominaleModello completoCapacità di interruzione (AC400V)
3P10A/16A/20A/25A/32A/40A/50AEBS53C‑10A~50A18IL
4P10A/16A/20A/25A/32A/40A/50AEBS54C‑10A~50A18IL

2) 100AF Frame (EBS103C / EBS104C)

PoliCorrente nominaleModello completoCapacità di interruzione (AC400V)
3P63A/75A/100AEBS103C‑63A/75A/100A37IL
4P63A/75A/100AEBS104C‑63A/75A/100A37IL

3) 200AF Frame (EBS203C / EBS204C)

PoliCorrente nominaleModello completoCapacità di interruzione (AC400V)
3P125A/150A/175A/200A/225A/250AEBS203C‑125A~250A37IL
4P125A/150A/175A/200A/225A/250AEBS204C‑125A~250A37IL

4) 400AF Frame (EBS403C / EBS404C)

PoliCorrente nominaleModello completoCapacità di interruzione (AC400V)
3P250A/300A/350A/400AEBS403C‑250A~400A50IL
4P250A/300A/350A/400AEBS404C‑250A~400A50IL
  1. Earth-Leakage Parameters (Whole Series)

Residual operating current (IΔn): 30mA/100mA/300mA/500mA optional (default 30mA for personal protection)

Operating time: ≤0.3s (IΔn=30mA), ≤0,1 s (IΔn≥100mA)

Tipo di protezione: Tipo A (AC + pulsating DC leakage), suitable for modern electronic loads

  1. Cross-Brand Equivalent Table for EBS Series

Below are equivalent models from major brands with matching core parameters (telaio, corrente nominale, poli, potere di interruzione) for replacement reference.

LS EBS ModelABB Tmax XTSchneiderNSXChint NM8LDelixi CDM1L
EBS53C‑50A‑3PXT1N160 TMD50 3P RCCBNSX100N TM50D 3P VigiNM8L‑100S/3300 50ACDM1L‑100C/3300 50A
EBS103C‑100A‑3PXT1N160 TMD100 3P RCCBNSX100N TM100D 3P VigiNM8L‑100S/3300 100ACDM1L‑100C/3300 100A
EBS203C‑200A‑3PXT2N250 TMD200 3P RCCBNSX250N TM200D 3P VigiNM8L‑250S/3300 200ACDM1L‑250C/3300 200A
EBS204C‑200A‑4PXT2N250 TMD200 4P RCCBNSX250N TM200D 4P VigiNM8L‑250S/4300 200ACDM1L‑250C/4300 200A
EBS403C‑400A‑3PXT4N630 TMD400 3P RCCBNSX630N TM400D 3P VigiNM8L‑630S/3300 400ACDM1L‑630C/3300 400A

Key Notes for Replacement

  1. Breaking capacity matching: Select alternatives with breaking capacity ≥ original EBS model to ensure short-circuit protection reliability.
  2. Earth-leakage module compatibility:

ABB requires RC221/RC222 earth-leakage accessories

Schneider requires Vigi modules (built-in / add-on)

Domestic NM8L/CDM1L have built-in earth-leakage modules, no extra parts needed

  1. Mounting dimension check: Width may vary between brands (per esempio., EBS203C-200A-3P: 105mm; Schneider NSX250: 108mm), affecting panel layout.
  2. Wiring type: Ensure replacement supports original mounting (fisso / collegare) and connection (anteriore / rear wiring).

III. Differenze chiave: EBS203C-200A-3P vs EBS204C-200A-4P

ArticoloEBS203C‑200A‑3P (3-polo)EBS204C‑200A‑4P (4-polo)
Poli & Terminali3 main terminals (L1/L2/L3)4 main terminals (L1/L2/L3/N)
Neutral controlNeutral bypasses breakerNeutral switched with phases
Protection scopeSovraccarico, short‑circuit, leakage on phases onlyFull protection on phases + neutro (including neutral leakage)
Larghezza105mm140mm
Applicable system3‑phase 3‑wire (IT, TN‑C without PEN)3‑phase 4‑wire (TN‑S, TN‑C‑S, TT)
Safety levelPhases switched only; extra isolation neededFull isolation; maggiore sicurezza
  1. Selezione & Procurement Advice
  2. Selezione del palo

Pure three-phase power loads (motori, compressori) → choose 3P (EBS203C)

Mixed three-phase + single-phase loads (illuminazione, prese) → choose 4P (EBS204C) to meet safety standards

  1. Earth-leakage current selection

Personal protection (socket circuits) → IΔn = 30mA

Electrical fire prevention (power/lighting mains) → IΔn = 100mA / 300mA

  1. Purchasing channels

Authorized domestic distributors, industrial e-commerce platform www.bestcontactor.com

Regular stock models: EBS53C-50A, EBS103C-100A, EBS203C-200A, EBS403C-400A, ecc.

Prec:

Lascia una risposta