Interruttore automatico ABB SACE EMAX E3H3200-PR123-P-LSIG - Contattore,interruttore automatico,inverter solare,contatore elettrico,batterie solari

Wechat: +86-13184948252 Whatsapp: 0086-13811255435 E-mail: kent@bestcontactor.com

Di Contatto |

Interruttore automatico ABB SACE EMAX E3H3200-PR123-P-LSIG - Contattore,interruttore automatico,inverter solare,contatore elettrico,batterie solari

interruttore automatico/

Interruttore automatico ABB SACE EMAX E3H3200-PR123-P-LSIG

Standard designation: E3H 3200 R3200 PR123/P-LSIG an air circuit breaker from ABB’s SACE EMAX series, frame size E3H. Model Segment Description E3H Frame designation (E3 = 3200A frame, H = high breaking capacity) 3200 Corrente nominale del telaio (3200UN) R3200 Trip unit rated current (3200UN) PR123/P Intelligent trip unit (PR123/P is high-end type with LCD display) ...

  • Dettagli del prodotto

Standard designation: E3H 3200 R3200 PR123/P-LSIG an interruttore automatico dell'aria from ABB’s SACE EMAX series, frame size E3H.

Segmento modelloDescrizione
E3HFrame designation (E3 = 3200A frame, H = high breaking capacity)
3200Corrente nominale del telaio (3200UN)
R3200Trip unit rated current (3200UN)
PR123/PSganciatore intelligente (PR123/P is high-end type with LCD display)
LSIGProtection configuration (L=overload, S=short-time delay, I=instantaneous, G=ground fault)
-PTipo di montaggio (P = withdrawable, F = fixed)

Codice ordine globale: 1SDA060849R1 (ritirabile) / 1SDA056503R1 (fisso)

Trade Description: ABB SACE EMAX E3H 3200A 3P/4P LSIG Intelligent Air Circuit Breaker

  1. Specifiche tecniche principali
ArticoloValoreNote
Dimensioni del telaioE3 (3200UN)Max rated current up to 3200A
Corrente operativa nominale (In)3200UNWith PR123/P-LSIG trip unit
Tensione di isolamento nominale (Ui)1000V e50/60Hz, sistema trifase
Tensione nominale di resistenza all'impulso1000VConforme all'IEC 60947-2
Ultimate Short-Circuit Breaking Capacity (terapia intensiva)100kA a 415 V CAHigh breaking, arc-free design
Service Short-Circuit Breaking Capacity (IC)100kA a 415 V CA (100% terapia intensiva)Full selective protection
Funzioni di protezione4-step LSIG protectionl, S, IO, G as defined above
Tipo di unità di sgancioPR123/PDisplay LCD, programmabile, registrazione degli eventi
MontaggioEstraibile (P) / Fisso (F)Withdrawable allows hot-swap maintenance
Poli3P or 4P4P includes neutral pole protection
ConnessioneRear horizontal (risorse umane) / Front horizontal (FR) / Verticale (V)Flexible panel integration
Resistenza meccanica20,000 operazioniDesign ad alta affidabilità
Resistenza elettrica2,000 operazioni (at rated short-circuit)Conforme all'IEC 60947-2
Dimensioni432×396.5×461mm (ritirabile)Compact footprint
Pesoca. 85kg (ritirabile)Configurazione standard
Protezione dall'ingressoIP30Dust-resistant, suitable for switchgear
Tensione di resistenza all'impulso12kVElevato isolamento per ambienti industriali
Temperatura operativa-25°C fino a +70°CWide-temperature design
Tensione di controllo220V CA/CC (standard)Optional 110V/24V AC/DC
  1. Applicazioni

This breaker is widely used in industrial and building power distribution systems:

  1. Industrial Main Distribution: Main incomers, substation LV sections, large motor control centers (Centro clienti)
  2. Edifici commerciali: Main switchboards in shopping malls, Hotel, hospitals for critical loads
  3. Centri dati: UPS I/O, server room main distribution, high-reliability protection
  4. Energia rinnovabile: inverter fotovoltaici, wind turbine converters, suitable for high-harmonic environments
  5. Infrastrutture: Metro, aeroporti, porti, withstands frequent operation and harsh conditions
  6. Attrezzatura OEM: Large industrial furnaces, laminatoi, marine electrical systems
  7. Caratteristiche principali

Intelligent Protection: PR123/P-LSIG 4-step protection with precise selectivity to minimize outages

Alta affidabilità: 100potere di interruzione kA, arc-free design for personnel and equipment safety

Flexible Configuration: Withdrawable/fixed, 3P/4P, multiple terminations for various installations

Smart Monitoring: LCD real-time display, event logging for diagnostics and preventive maintenance

Espandibilità: Supports PR120/V (voltage monitoring), PR120/K (load control), PR120/D (directional protection)

Comunicazione: Modbus opzionale, Profibus, Ethernet/IP for IIoT integration

Eco-certified: RoHS and REACh compliant, basso consumo energetico (<50W control circuit)

  1. Detailed Protection Functions (PR123/P-LSIG)
ProtezioneDescrizioneGamma regolabileApplicazione
Sovraccarico (l)Tempo inverso, prevents overheating0.4–1.0In, 0.1–60sMotori, trasformatori, cavi
Short-Time Delay (S)Definite/inverse time for selectivity2–10 pollici, 0.05–3sCascaded distribution, no upstream tripping
Istantaneo (IO)No-delay trip for severe faults5–20InEmergency short-circuit protection
Ground Fault (G)Detects earth current, shock/fire prevention0.2–0.8In, 0.1–1sPersonnel and insulation safety
Phase Unbalance (U)Monitors phase current difference10%–50% unbalanceThree-phase motor protection
Sottotensione (UV)Detects voltage drop60%–90%Un, 0.1–10 secondiCritical equipment voltage stability
Sovratensione (OV)Detects overvoltage105%–120%Un, 0.1–10 secondiGrid fluctuation protection
Overtemperature (OT)Internal trip unit thermal protectionFactory setSelf-protection in harsh environments
  1. Alternative

6.1 Alternative ABB della stessa serie

ModelloCaratteristicheApplicazione
E3H 3200 R2500 PR123/P-LSIG2500Una corrente nominale3200A frame with lighter load
E3H 3200 R3200 PR122/P-LSIGPR122/P (basic trip unit)Budget-friendly full protection
E3H 3200 R3200 PR123/P-LSIWithout ground fault protectionSystems not requiring earth fault protection
E3N 3200 R3200 PR123/P-LSIGE3N (medium breaking 65kA)Lower short-circuit duty

6.2 Alternative multimarca

MarcaModello alternativoSpecifiche corrispondenti
SchneiderMT32H100 LSIG3200UN, 100IL, LSIG
Siemens3WL3225-3CB36-4GA03200UN, 100IL, LSIG
Interruttore ChangshuCW3-3200/3P 100kA LSIGDomestic high-performance alternative
CintoNA1-3200X-3200M/3PEconomic domestic alternative
  1. Selezione & Note di installazione
  2. Telaio & Rated Current Match: E3H max 3200A; select trip rating 630A-3200A based on load
  3. Configurazione della protezione:

LSIG: Full protection for main incomers and critical loads

LSI: Without ground fault for general distribution

LI: Basic overload + instantaneous for feeders

  1. Tipo di montaggio:

Estraibile (P): For frequent maintenance, online replacement

Fisso (F): Space-limited, low-maintenance sites

  1. Terminazione:

risorse umane: Collegamento posteriore

FR: Collegamento frontale

V: Vertical for busbar systems

  1. Accessori:

Contatti ausiliari: Up to 10NO+10NC

Sganciatore di minima tensione: Loss-of-voltage protection

Viaggio di derivazione: Intervento remoto

Communication modules: Smart monitoring

  1. Prezzo di riferimento (Tax-included, RMB)
ConfigurazioneFascia di prezzoNote
Withdrawable 3P28,000 - 35,000With PR123/P-LSIG
Withdrawable 4P30,000 - 38,000With neutral protection
Fixed 3P25,000 - 32,000~10% lower than withdrawable
Fixed 4P27,000 - 35,000With neutral protection
Modbus Communication Module2,000 - 3,000Optional extra
  1. Vantaggi fondamentali
  2. Full Selectivity: LSIG with precise settings minimizes outage area
  3. Alta affidabilità: 100kA rottura + arc-free design
  4. Smart Monitoring: LCD and event logs for easy diagnostics
  5. Flexible Layout: Multiple mounting, palo, and connection options
  6. IIoT Ready: Industrial communication for intelligent power management

Complete List of ABB SACE EMAX Series & Confronto tra marchi

  1. EMAX Naming Convention & Parametri fondamentali

1.1 Ripartizione del modello

Segmento modelloDescrizioneEsempio
E1/E2/E3/E4/E6/X1Dimensioni del telaio (E1=1600A, E2=2500A, E3=3200A, E4=4000A, E6=6300A, X1=630A)E3H
H/NClasse di rottura (H=high, N=medium)H
RXXXTrip rated currentR3200
PR121/PR122/PR123Tipo di sganciatore (PR123 = high-end with LCD)PR123/P
LSIG/LSI/LIProtection setLSIG
P/FMontaggioP

Esempio standard: E3H 3200 R3200 PR123/P-LSIG-P

Codice ordine globale: 1SDA060849R1 (ritirabile) / 1SDA056503R1 (fisso)

1.2 Breaking Capacity Classes

ClasseBreaking Capacity at 400VApplicazione
N65ILIndustria generale & commerciale
H100ILIndustria pesante & main distribution
V150ILHigh fault current areas (petrolchimico, metallurgia)
  1. Full EMAX Model List

2.1 Standard Range (X1/E1/E2/E3/E4/E6)

TelaioCorrente del fotogrammaIntervallo correnteRotturaStandard TripProtezioneMontaggioCodice d'ordine tipico
X1630UN250–630AN (42IL)PR121/PLSIGP/F1SDA052101R1
E11600UN630–1600AN (65IL), H (100IL)PR122/PLSIGP/F1SDA053101R1
E22500UN1250–2500AN (65IL), H (100IL)PR122/PLSIGP/F1SDA054101R1
E33200UN1600–3200AN (65IL), H (100IL), V (150IL)PR123/PLSIGP/F1SDA056503R1
E44000UN2000–4000AN (65IL), H (100IL), V (150IL)PR123/PLSIGP/F1SDA058101R1
E66300UN3200–6300AH (100IL), V (150IL)PR123/PLSIGP/F1SDA060101R1

2.2 Special Application Versions

SuffissoSensoApplicazioneEsempio
/DCDC dedicatoSolar, wind, accumulo di energiaE3H 3200 R3200 PR123/P-LSIG/DC
/VFVFD output ratedInverter side protectionE2H 2500 R2500 PR122/P-LSIG/VF
/LTTLow temp tolerant-40°C fino a +70°CE1H 1600 R1600 PR122/P-LSIG/LTT
/EEnhanced voltage690–1150V ACE3H 3200 R3200 PR123/P-LSIG/E

2.3 Confronto delle unità di viaggio

Unità di viaggioCaratteristicheDisplayLogCommApplicazione
PR121/PBasic LI/LSIGUIDATO10 eventsNessunoDistribuzione semplice
PR122/PStandard LSIGGUIDATO20 eventsModbus optionalIndustria generale
PR123/PAdvanced LSIG+schermo LCD100 eventsModbus/ProfibusCarichi critici & centri dati
  1. ABB EMAX vs Other Brands (Direct Match)

3.1 Full Cross-Brand Table

ABB EMAX ModelFrame/InRotturaProtezioneSchneiderSiemensChangshuCinto
E1H 1600 R1600 PR122/P-LSIG1600A/1600A100ILLSIGMT16H100 LSIG3WL1120-3CB36-4GA0CW3-1600/3P 100kA LSIGNA1-1600X-1600M/3P LSIG
E2H 2500 R2500 PR122/P-LSIG2500A/2500A100ILLSIGMT25H100 LSIG3WL1225-3CB36-4GA0CW3-2500/3P 100kA LSIGNA1-2500X-2500M/3P LSIG
E3H 3200 R3200 PR123/P-LSIG3200A/3200A100ILLSIGMT32H100 LSIG3WL1332-3CB36-4GA0CW3-3200/3P 100kA LSIGNA1-3200X-3200M/3P LSIG
E4H 4000 R4000 PR123/P-LSIG4000A/4000A100ILLSIGMT40H100 LSIG3WL1440-3CB36-4GA0CW3-4000/3P 100kA LSIGNA1-4000X-4000M/3P LSIG
E6H 6300 R6300 PR123/P-LSIG6300A/6300A100ILLSIGMT63H100 LSIG3WL1663-3CB36-4GA0CW3-6300/3P 100kA LSIGNA1-6300X-6300M/3P LSIG
E3N 3200 R2500 PR122/P-LSI3200A/2500A65ILLSIMT32N100 LSI3WL1325-3CB36-4GA0CW3-3200/3P 65kA LSINA1-3200X-2500M/3P LSI
X1N 630 R630 PR121/P-LI630A/630A42ILLIMT06N100 LI3WL1063-3CB36-4GA0CW3-630/3P 42kA LINA1-630X-630M/3P LI

3.2 Key Model Matching (with Order Codes)

ABB CodeModello completoSchneider CodeSiemens CodeMatch Specs
1SDA056503R1E3H 3200 R3200 PR123/P-LSIG-FLV432630 (MT32H100)3WL1332-3CB36-4GA03200UN, 100IL, LSIG, fisso
1SDA060849R1E3H 3200 R3200 PR123/P-LSIG-PLV432631 (MT32H100)3WL1332-3CB36-4GA13200UN, 100IL, LSIG, ritirabile
1SDA054101R1E2H 2500 R2500 PR122/P-LSIG-PLV432531 (MT25H100)3WL1225-3CB36-4GA12500UN, 100IL, LSIG, ritirabile
1SDA053101R1E1H 1600 R1600 PR122/P-LSIG-PLV432431 (MT16H100)3WL1120-3CB36-4GA11600UN, 100IL, LSIG, ritirabile
1SDA052101R1X1N 630 R630 PR121/P-LI-PLV432031 (MT06N100)3WL1063-3CB36-4GA1630UN, 42IL, LI, ritirabile
  1. Selezione & Linee guida per la sostituzione

4.1 Technical Matching Rules

CategoriaMatching PrincipleNote
Frame/InDirect match or downsize630A frame cannot exceed 630A
Capacità di interruzione≥ system short-circuit currentH-class (100kA+) recommended for industry
ProtezioneMatch or upgradeLSIG can replace LSI; not vice versa
MontaggioSame type preferredWithdrawable can replace fixed; may need cabinet mods
Tensione di controlloIdentical or universal220V AC/DC preferred for flexibility
ConnessioneSame orientationFront/rear/vertical must align

4.2 Brand Strength Comparison

MarcaPunti di forza fondamentaliTypical Use
ABB EMAXUp to 150kA breaking, PR123 smart trip, arc-free, 30,000 mech cyclesCarichi critici, centri dati, industria pesante
Schneider MTMultiple breaking levels, Micrologic precision, modulare, supporto globaleCommercial, OEM, renewables
Siemens 3WL690V rated, protezione contro le sovratensioni, thermal-magnetic options, full commsInfrastrutture, sbarra, petrolchimico
Changshu CW330–40% lower cost, form-fit compatible, domestic supplyProgetti sensibili ai costi
Chint NA1Ultra-economical, full LSIG option, simple maintenanceResidenziale, industria leggera, rural grids

4.3 Prezzo di riferimento (Tax-included, RMB)

TelaioABB EMAXSchneider MTSiemens 3WLChangshu CW3Chint NA1
630UN8,000–12.0007,500–11,0008,500–12,5004,000–6.0003,000–5.000
1600UN15,000–22.00014,000–20.00016,000–23,0008,000–12.0006,000–10.000
3200UN28,000–35.00027,000–34.00029,000–36,00015,000–20.00012,000–18.000
6300UN50,000–65.00048,000–62,00052,000–68,00028,000–38,00025,000–35.000
  1. Raccomandazioni per la selezione
  2. Carichi critici: Use ABB EMAX or Schneider MT with PR123/Micrologic trips
  3. Efficienza dei costi: 630A-1600A → Changshu CW3 or Chint NA1
  4. Sostituzione tra marchi diversi:

630A-3200A: Direct form-fit replacement

4000A+: Consult manufacturer for cabinet compatibility

  1. Aggiornamenti:

Replace old ACBs (ME/DW15) with EMAX/MT/3WL

Add communication for smart power management

Prec:

Prossimo:

Lascia una risposta

Lasciate un messaggio