Questo è un 10 Mbps Ethernet communication module for CV-series PLCS. Supporta TCP/IP, UDP/IP, Protocolli FINS e funzioni del server FTP, consentendo la comunicazione dati tra PLC, computer host e altri dispositivi PLC.
- Spiegazione del codice modello
| Segmento di codice | Descrizione |
| CV500 | Omron SYSMAC CV-series PLC module, compatible with CPU units of CV500, CV1000, CV2000 and CVM1 series |
| ETN | Identifier for Ethernet communication function |
| 1 | Product version number, basic Ethernet unit |
- Main Specifications
| Articolo | Specifiche | Osservazioni |
| Basic Features | ||
| Communication Standard | Ethernet Version 2 (IEEE 802.3 compiacente) | CSMA/CD access method supported |
| Transmission Rate | 10 Mbit/s (baseband transmission) | Fixed speed |
| Transmission Medium | Coaxial cable (10BASE5) | Maximum segment length: 500 M |
| Massimo. Nodes per Segment | 100 nodes | Node spacing must be a multiple of 2.5 M |
| Communication Ports | 8 concurrent communication ports | Supports simultaneous operation of multiple applications |
| Protocolli supportati | TCP/IP, UDP/IP, FINS, FTP Server | Socket interface communication available |
| Caratteristiche Elettriche | ||
| Alimentazione elettrica | Powered by PLC backplane | Massimo. current consumption: 1.7 UN (including transceiver) |
| Transceiver Power Output | 12 VCC, massimo. 0.35 UN | Powers external transceivers |
| Connettore | 15-pin D-sub (IEEE 802.3 compiacente) | Equipped with slide lock mechanism |
| Dimensioni fisiche | ||
| Dimensioni | 34.5×250×98.1 mm (L×A×P) | Standard size for CV-series modules |
| Peso | 500 G (ca. 1.1 libbre) | Weight including housing |
| Posizione di montaggio | Designated slots on CPU rack or expansion CPU rack | Depends on backplane type; maximum 4 units per PLC |
| Caratteristiche funzionali | ||
| Network Diagnostics | PING response, inter-node test, error logging | Self-diagnosis and network status monitoring supported |
| FTP Function | File read & write (for RAM/EEPROM cards) | Requires V1-version CPU and PLC in PROGRAM mode |
| Data Buffer | TCP: 4 KB (Tx/Rx); UDP: 9 KB (Tx) / 9.016 KB (Rx) | Refer to Appendix F for detailed configuration |
| Massimo. Distanza di comunicazione | 2.5 km per system (multiple segments via repeaters) | Single segment: massimo. 500 M |
- Full Model List (CV-series Ethernet Units)
| Modello | Nome | Caratteristiche principali | Scenari applicativi |
| CV500-ETN01 | Ethernet Unit | Di base 10 Mbps Ethernet, 8 porti, FINS/FTP supported | Standard industrial Ethernet communication, HMI & host monitoring |
| CV500-ETN11 | Enhanced Ethernet Unit | More protocols, prestazioni più elevate | Complex network environments, multi-system integration |
| CV500-MC221 | Ethernet Module | Rich integrated functions, Modbus TCP supported | Communication with third-party devices, SCADA integration |
| CV500-ETN21 | High-speed Ethernet Unit | 10/100 Mbps auto-negotiation | High-volume data transmission, real-time monitoring systems |
> Nota: Orders for CV500-ETN01 were suspended in March 2012, and full production ceased around 2017.
- Modelli sostitutivi & Confronto della concorrenza
4.1 Official Omron Replacement Solutions
| Modello originale | Sostituzione consigliata | Compatibilità | Improvements |
| CV500-ETN01 | CS1W-ETN21 | PLC needs to be upgraded to CS1 series | 10/100 Mbps auto-negotiation, extended protocol support |
| CV500-ETN01 | CJ1W-ETN21 | PLC needs to be upgraded to CJ1 series | Dimensioni compatte, prestazioni più elevate, PROFINET supported |
| CV500-ETN01 | Built-in Ethernet of NJ/NX Series | Full PLC upgrade required | Ethernet/IP & Gigabit Ethernet supported, integrated motion control |
4.2 Cross-brand Competitor Comparison (Function Compatibility)
| Marca | Modello | Transmission Rate | Protocolli supportati | Fascia di prezzo |
| Siemens | CP 343-1 | 10/100 Mbit/s | TCP/IP, UDP, PROFINET | Medio-Alto |
| Mitsubishi | QJ71E71-100 | 10/100 Mbit/s | TCP/IP, UDP, MC Protocol | Medio |
| Schneider Electric | 140NOE77101 | 10/100 Mbit/s | TCP/IP, UDP, ModBus | Medio-Alto |
| Rockwell Automazione | 1756-ENBT | 10/100 Mbit/s | TCP/IP, UDP, Ethernet/IP | Alto |
| Omron | CV500-ETN01 | 10 Mbit/s | TCP/IP, UDP, FINS, FTP | Basso (Interrotto) |
- Ambiente applicativo & Casi di settore
5.1 Scenari applicabili
Industrial Automation Production Lines: Communication between PLCs and host monitoring systems for production data acquisition and remote control.
Sistemi di controllo del processo: Data exchange among multiple PLCs for distributed control in chemical and power industries.
Logistica & Warehousing Systems: Control of AGVs and conveyors, data interaction with WMS.
Automazione degli edifici: Integration of HVAC and security systems for centralized monitoring and management.
Semiconductor Equipment: Precision control and data collection; FTP-based program update.
5.2 Not Recommended Scenarios
High-speed Real-time Control: Limited to 10 Mbit/s, not suitable for millisecond-level response requirements.
Modern Industrial Networks: Does not support Gigabit Ethernet, EtherNet/IP and other new protocols.
New Equipment Development: Interrotto; no official technical support or spare parts supply.
Long-distance Communication: Single segment limited to 500 M; additional repeaters increase costs for long-range transmission.
5.3 Casi applicativi tipici
Caso 1: Monitoring System for Automotive Component Production Lines
Configurazione: 3 sets of CV1000 PLC + CV500-ETN01, connected via coaxial cables
Funzioni: Real-time collection of stamping, welding and assembly data, uploaded to SCADA system
Vantaggi: 8 concurrent connections for simultaneous communication with HMI, database server and remote monitoring terminals
Key Technology: FINS for inter-PLC data sharing; FTP for remote program update
Caso 2: Data Acquisition for Food & Beverage Filling Lines
Configurazione: CV500 PLC + CV500-ETN01 + Barcode Reader + Weighing Sensor
Funzioni: Collect bottle weight, production date and batch information, transmit to MES via Ethernet
Vantaggi: UDP for high-speed data transmission; TCP ensures reliability of critical data
Risoluzione dei problemi: PING command and inter-node test for quick network fault diagnosis
- Risoluzione dei problemi & Maintenance Guide
6.1 LED Indicator Diagnosis
| Indicatore | Colore | Stato | Senso | Soluzione |
| RUN | Verde | Spento | Module not running | Check power supply and restart PLC |
| ERC | Rosso | SU | Invalid node address (out of 1–126) or hardware failure | Reset node address; check module connection |
| ERH | Rosso | SU | PC error, wrong unit number or I/O table setting | Verify unit number; reconfigure I/O table |
| ERH | Rosso | Blinking | IP address unset or invalid | Reconfigure IP address |
| SD/RD | Arancia | Spento | No data transmission/reception | Check network wiring and communication parameters |
| FTP | Arancia | SU | FTP server active | Normal status |
| TS | Arancia | SU | Inter-node test in progress | Normal status |
6.2 Difetti comuni & Soluzioni
| Fenomeno di guasto | Possibili cause | Soluzioni |
| Errore di comunicazione | 1. Conflicting unit/node number | 1. Power off and reset unit number (00–15) & node number (1–126) |
| 2. Incorrect IP address | 2. Check for IP address conflict | |
| 3. Loose cable connection | 3. Inspect locking of 15-pin D-sub connector | |
| 4. Defective transceiver | 4. Replace with a functional transceiver | |
| FTP transmission failure | 1. Non-V1 CPU version | 1. Confirm V1 CPU (per esempio. CV500-CPU01-EV1) |
| 2. PLC not in PROGRAM mode | 2. Switch PLC to PROGRAM mode | |
| 3. Memory card write-protected | 3. Disable write protection on memory card | |
| 4. Unsupported card type | 4. Use RAM or EEPROM card (EPROM is read-only) | |
| Slow communication speed | 1. Overloaded network | 1. Reduce concurrent connections (≤8) |
| 2. Buffer overflow | 2. Optimize data volume and expand buffer | |
| 3. Excessive transmission distance | 3. Shorten transceiver cable (≤50 m) | |
| Intermittent disconnection | 1. Power fluctuation | 1. Stabilize PLC power supply |
| 2. Interferenza elettromagnetica | 2. Separate communication cables from power cables; use shielded cables | |
| 3. Overheated transceiver | 3. Ensure good ventilation for transceivers |
6.3 Programma di manutenzione & Note
| Articolo di manutenzione | Ciclo | Note operative |
| Module Cleaning | Ogni 3 mesi | Power off first; remove dust with dry compressed air. Do not use liquid cleaners. |
| Connector Inspection | Ogni 6 mesi | Check for loose connection and pin oxidation; clean if necessary. |
| Network Test | Ogni 1 month | Run PING test and inter-node test to verify network quality. |
| Firmware Check | Ogni 1 anno | Confirm firmware version; update with professional tools if required. |
| Spare Parts Preparation | For critical systems | Prepare replacement modules or overall upgrade plans due to product discontinuation. |
- Linee guida per la selezione & Quick Reference
7.1 Three Key Points for CV500-ETN01 Selection
- Compatibilità PLC: Only for CV/CVM1 series; not compatible with CS/CJ series.
- Communication Demand: 10 Mbps speed and 8 concurrent ports for basic Ethernet communication.
- Ciclo di vita del prodotto: Interrotto. Select replacement models for new projects.
7.2 Troubleshooting Tips
LED off → Check power; LED blinking → Check IP address; steady red LED → Check parameter settings
Data transfer failure → Verify PROGRAM mode; unstable connection → Check EMI shielding; low speed → Reduce network load
7.3 Priority of Replacement Solutions
- Series upgrade path: CV500 → CS1 → CJ1 → NJ/NX
- Corrispondenza delle funzioni: Ensure compatibility with original protocols (FINS/FTP) and new requirements
- Cost evaluation: Balance the cost of module replacement and full system upgrade
Supplementary Content: Ambiente applicativo & Casi di settore
- Ambiente applicativo (Compatibilità & Restrictions)
1.1 Hardware & Compatibilità del sistema
PLC Platform: Exclusive to CPU racks and expansion racks of Omron CV500/CV1000/CV2000/CVM1 series. Massimo. 4 units per PLC.
Network Topology: 10BASE5 thick coaxial cable. Single segment: massimo. 500 M; node spacing: multiple of 2.5 M; massimo. 100 nodes per segment. Total distance up to 2.5 km with repeaters.
Protocolli di comunicazione: TCP/IP, UDP/IP, FINS, FTP Server. 8 concurrent ports for multi-device communication.
Electrical Environment: Backplane power supply (1.7 UN); external transceiver: 12 VCC / 0.35 UN. Temperatura operativa: 0–55 °C. Keep away from inverters and large motors to avoid strong electromagnetic interference.
1.2 Scenari applicabili (Vantaggi)
✅ Renovation & Maintenance of Old Production Lines: Network upgrade for legacy CV-series PLCs (replacing traditional RS-232/422).
✅ Medium & Low-speed Data Acquisition: For non-real-time applications such as production status, temperature and pressure monitoring.
✅ Multi-PLC Networking: Networking of 3–10 CV-series PLCs in one workshop for FINS-based data exchange.
✅ Host Monitoring (SCADA): Data exchange between PLCs, industrial PCs and HMIs for process visualization and remote operation.
✅ Remote Program Update: Read/write CPU programs via FTP (RAM/EEPROM card), reducing on-site card plugging operations.
1.3 Restricted Scenarios (Limitazioni)
❌ High-speed Real-time Control: 10 Mbps bandwidth insufficient for motion control, servo synchronization and high-frequency closed-loop control (per esempio. macchine confezionatrici, high-speed machine tools).
❌ New Equipment Development: Discontinued since 2012; risk of spare parts shortage and no official support.
❌ Modern Industrial Networks: Incompatible with 100 Mbps/Gigabit Ethernet, Ethernet/IP, PROFINET, Modbus TCP and other mainstream industrial protocols.
❌ Long-distance & Complex Topology: Complicated cabling for coaxial cables, poor anti-interference performance and high maintenance costs.
- Major Industry Applications (Popular in 2000–2010)
2.1 Automotive Component Production Lines (Più comune)
Configurazione: 3 × CV1000-CPU01-EV1 + CV500-ETN01 + 10BASE5 coaxial network + SCADA industrial PC
Process: Stamping, welding, assembly and inspection. Collect equipment status, output and yield data and upload to MES. FINS for inter-PLC safety interlock (per esempio. welding stations).
Improvement: Replaced old RS-485 multi-drop network to solve slow speed and frequent disconnection. 8 concurrent ports support connection with HMI, MES and remote maintenance terminals simultaneously.
2.2 Cibo & Beverage Filling Lines
Configurazione: CV500-CPU01 + CV500-ETN01 + Weighing Sensor + Barcode Reader + FTP Server
Process: Bottle washing, filling, capping, labeling and inspection. UDP for high-speed transmission of bottle weight, batch number and production date; TCP guarantees reliability of yield and alarm data. FTP for remote recipe update.
Valore: Cost-effective PLC-Ethernet-MES closed-loop system, meeting product traceability requirements for food industry.
2.3 Chemical Process Control (A prova di esplosione & Alta affidabilità)
Configurazione: Redundant CVM1-CPU21-V2 + 2 × CV500-ETN01 (main/backup) + Redundant coaxial network + DCS host
Process: Reactor temperature & pressure control, pipeline flow monitoring and valve interlock. FINS for data exchange with DCS. PING and inter-node test for fast fault location.
Adattabilità ambientale: Wide temperature range and vibration resistance, suitable for dusty and humid chemical workshops.
2.4 Automazione degli edifici (HVAC & Security)
Configurazione: CV2000-CPU01 + CV500-ETN01 + Air-conditioning Controller + Fire Alarm System + Access Control System
Funzioni: Centralized temperature & humidity control for central air conditioning, fire alarm linkage and access data upload. 8 concurrent ports manage multiple subsystems simultaneously.
Vantaggi: Cost-effective and reliable Ethernet solution for large buildings in the 2000s with easy maintenance.
2.5 Semiconductor Equipment (Legacy Non-critical Processes)
Configurazione: CV500-CPU01-EV1 + CV500-ETN01 + Wafer Inspection Station + Data Server
Process: Status monitoring and data recording for non-critical processes such as wafer cleaning and packaging. FTP for inspection report upload and remote program download.
Nota: Only applied to legacy equipment and non-high-speed processes. New devices adopt EtherNet/IP or Gigabit Ethernet.
- On-site Application Tips & Consigli per l'aggiornamento
3.1 On-site Application Tips
IP Planning: Node address: 1–126 (no duplication); Subnet mask: 255.255.255.0
Regole di cablaggio: Keep coaxial cables at least 30 cm away from power cables. Ensure waterproof and well-grounded connectors.
Maintenance Routine: Run PING test monthly; clean modules and connectors quarterly; back up programs annually.
3.2 Aggiornamento & Suggerimenti per la sostituzione (Anno 2026)
Short-term Maintenance: Use original second-hand CV500-ETN01 as spare parts; use third-party compatible products with caution.
Mid-term Upgrade: Migrate PLC to CS1/CJ1 series, adopt CS1W-ETN21 / CJ1W-ETN21 (10/100 Mbps auto-negotiation, FINS & Modbus TCP supported).
Long-term Renovation: Upgrade to NJ/NX series with built-in Gigabit Ethernet, supporting EtherNet/IP and PROFINET for Industry 4.0 applications.
Contattore,interruttore automatico,inverter solare,contatore elettrico,batterie solari





















NH42-63-318x560.png)