Interfaccia uomo-macchina OMRON NS8-TV00B-ECV2

Model Code Breakdown NS8-TV00B-ECV2 NS8: NS series, 8.4-inch programmable terminal HMI TV: TFT Color LCD 00: Modello standard, without video input (TV01 = supports video module) B: Black bezel (model without “B”: light gray bezel NS8-TV00-ECV2) CE: Built-in Ethernet port V2: 2nd generation hardware version Cross reference within series: NS8-TV00B-V2 = No Ethernet; NS8-TV00B-ECV2 = ...

  • Dettagli del prodotto

Scomposizione del codice modello

NS8-TV00B-ECV2

NS8: NS series, 8.4-inch programmable terminal HMI

TV: TFT Color LCD

00: Modello standard, without video input (TV01 = supports video module)

B: Black bezel (model without “B”: light gray bezel NS8-TV00-ECV2)

CE: Porta Ethernet integrata

V2: 2nd generation hardware version

Cross reference within series: NS8-TV00B-V2 = No Ethernet; NS8-TV00B-ECV2 = Standard equipped with Ethernet

  1. Specifiche hardware principali
ArticoloParametro
Display8.4″ TFT Color LCD, Resolution 640×480(VGA)
Display Colors65,536 colori (16-morso)
Tocca TipoAnalog Resistive Touch Screen
Alimentazione elettricaDC24V (Allowable range:20.4~27.6V), Max power consumption ≤18W
Memoria del programma60 MB
Interfacce✅ 10/100BASE-T Ethernet
✅ Dual RS232C (DB9)
✅ USB Slave (Program Upload/Download)
✅ USB Host (USB Flash Drive / Mouse)
Front ProtectionIP65 / NEMA4 (When properly sealed after panel mounting)
Temperatura operativa0~50℃; Storage Temperature -20~60℃ (Nessuna condensa)
Dimensioni complessive315(W) × 241(H) × 48.5(D) mm
Panel Cutout Dimensions298 × 224 mm
RetroilluminazioneCCFL Cold Cathode Fluorescent Lamp (Service life approx. 50,000 ore; yellowing and dimming will occur after aging)
  1. Informazioni sul software

Software di programmazione: NS-Designer Ver.6.X

Protocolli di comunicazione: OMRON Collegamento dell'ospite, FINS Ethernet. Compatible with CJ/CS/CP1H/CP1E series PLCs; also supports Modbus RTU/TCP

⚠️ Not compatible with Sysmac Studio; cannot directly replace NA/NJ series HMI

  1. Avviso sul ciclo di vita del prodotto

✅ Official End of Production (EOP)

Available supply: New surplus stock and used refurbished units; spare part prices keep rising.

Soluzioni sostitutive

  1. Direct in-place replacement (Preferred, compatible mounting cutout)

NA8-12W101-V2 (8.4-inch NA series; wide screen, note resolution difference, screen project needs full redesign)

  1. Minimum program modification migration solution

Used NS8-TV00B-ECV2

  1. Alternative domestiche: Weinview, Kinco 8-inch HMI; requires full screen redrawing and communication debugging.
  2. Difetti comuni & Pitfall Reminders
  3. Typical failure: CCFL backlight aging leading to black screen. Backlight strip replacement or LED backlight modification is feasible.
  4. Touch malfunction: Touch panel aging; independent replacement touch glass available for purchase.
  5. Ethernet communication failure: The Ethernet chip of ECV2 model is vulnerable to electrostatic damage. Surge protection is recommended for communication cables.
  6. Compatibilità del programma: Projects developed for V2 hardware cannot be opened directly on early V1 units.
  7. Ordering distinction: Do not confuse NS8-TV00B-V2 (Niente Ethernet) and ECV2 (Con Ethernet).
  8. Applicazioni tipiche

Macchine utensili, macchine per l'imballaggio, injection molding equipment, linee di trasporto, retrofitting projects equipped with classic OMRON PLCs (CP1H, CJ1M, CS1G).

If needed, I can supplement:

CAD text of panel cutout dimensions

Rear interface pin assignment definition

Step-by-step guide for FINS Ethernet communication setup via NS-Designer

Simple operation guide for backlight modification

Programming Software for OMRON NS8-TV00B-ECV2

  1. Software Evolution

This unit belongs to NS Series V2 Hardware (-ECV2)

  1. Original standalone software: NS-Designer (Max Version V6)
  2. Later integrated software: CX-Designer

✅ CX-Designer is widely adopted currently

CX-Designer is integrated into the CX-One software suite, CX-One installation is prioritized.

  1. Version Selection Recommendation
  2. CX-One 4.0 / 4.1 (Most stable, widely used in industrial automation)

Built-in CX-Designer, fully compatible with NS8-TV00B-ECV2.

  1. Newer CX-One 4.2/4.3 are also compatible, but compatibility mode configuration is required under Win10/Win11.
  2. ❌ Sysmac Studio is NOT supported!

Sysmac Studio only supports NA/NJ/NX series; it cannot work with legacy NS touch screens.

  1. Project File Formats

Source project file: `.ipp`

Compiled file downloaded to HMI: `.tsp`

  1. Note importanti
  2. Old NS-Designer projects can be opened and converted directly with CX-Designer; reverse conversion is not available.
  3. Program download methods: Ethernet(FINS), USB-B cable, RS232 serial port.
  4. NS8-TV00B-ECV2 is V2 hardware; select exact model NS8-TV00B-ECV2 in software, avoid selecting V1 version.
  5. HMI firmware upgrade can be performed within CX-Designer.
  6. Common Confusion Reminder

Many users mix up different software:

NB series HMI → NB-Designer

NA/NJ new generation → Sysmac Studio

Legacy NS touch screen → CX-Designer (CX-One Suite)

If needed, Posso fornire:

Procedures for downloading HMI projects via FINS Ethernet

CX-One compatibility settings guide under Win11

Operation process for program upload and decryption

Full List of Supported Communication Protocols for OMRON NS8-TV00B-ECV2

Hardware Interfaces: Dual RS232C (Port A / Port B; Port B switchable to RS422/485) + Built-in RJ45 Ethernet + Ospite USB + USB Slave

Software: CX-Designer (CX-One Suite). All protocols can be selected in [Impostazioni di comunicazione] of project.

  1. Protocols for Ethernet Port (Built-in on ECV2)

For connecting OMRON PLC, program download and PC host communication

  1. FINS Ethernet (UDP/TCP) [Primary Protocol]

For CJ1M/CJ2M/CS1G/CP1H/CP1E OMRON PLCs, più comunemente usato.

  1. ModBus TCP (Master)

Direct connection to Modbus TCP instruments and third-party PLCs.

  1. Controller Link (Ethernet routing)
  2. Memory Link (Ethernet)

Data exchange with custom PC host software.

  1. Serial Port Protocols (RS232C / RS422/485)

✅ OMRON native protocols (For OMRON PLC connection)

  1. NT Link 1:1 / NT Link 1:N (High-speed serial)

Compatible with CJ/CS/CP1H series (Classic serial communication for NS series)

  1. Collegamento dell'ospite (1:1)

Legacy OMRON PLCs: CVM1, C200H, CPM1A, ecc.

  1. CompoWay/F

Direct connection to OMRON temperature controllers E5CC/E5AZ and sensors, no PLC forwarding required.

✅ Standard Industrial Protocols

  1. ModBus RTU (Master)

Frequency inverters, strumenti, third-party PLCs (Only RTU supported, Modbus ASCII is not supported)

  1. Memory Link (Seriale)

Serial data exchange between PC host and HMI.

✅ Third-party PLC Serial Protocols

Mitsubishi: MC Protocol (3C/4C Frame) → FX/Q Series

Rockwell AB: DF1 Protocol

GE Fanuc: SNP-X Protocol

Siemens: Siemens 3964(R)/RK512 (S5/Old S7 serial, S7 Ethernet is not supported)

⚠️ Critical Limitation: Native S7 TCP / Profinet / CC-Link are unavailable. Cannot connect S7-1200/1500 directly via Ethernet; Modbus TCP gateway is required for communication with new Siemens PLCs.

  1. USB Port Functions (Cannot be used for PLC communication, only peripheral connection & download del programma)
  2. USB Slave (Type-B): Connect PC CX-Designer for program upload/download
  3. Ospite USB (Type-A): Unità flash USB (Registrazione dei dati, program import), USB printer, mouse

❌ USB cannot communicate with PLC

  1. Key Engineering Pitfall Notes
  2. Port A and Port B can run different protocols simultaneously, enabling one HMI to connect two sets of equipment independently.
  3. NS8-TV00B-ECV2 only works as Communication Master, cannot act as Slave. It cannot be read/written actively by external PLCs.
  4. Ethernet port and serial ports support parallel communication at the same time.
  5. Firmware version affects protocol stability: Upgrade HMI system firmware to V8 or above for better reliability of third-party protocols.
  6. Ethernet/IP, OPCUA, Profinet are not supported natively.
  7. Distinzione: NS series protocols are incompatible with NA/NB series.

Recommended Communication Schemes

  1. OMRON CJ/CP Series PLC → FINS Ethernet (Prima scelta)
  2. Multiple E5CC Temperature Controllers → CompoWay/F (RS485)
  3. Invertitori & General Instruments → Modbus RTU (RS485) or Modbus TCP
  4. Mitsubishi FX Equipment Retrofit → MC Protocol (Seriale)

If needed, Posso fornire:

Complete configuration steps for FINS Ethernet communication

Wiring diagram and CX-Designer parameter template for Modbus RTU

Configuration points for dual serial ports driving multiple devices concurrently

Supported Operating Systems for CX-Designer (Matching NS8-TV00B-ECV2)

CX-Designer is embedded within the CX-One software suite. All descriptions below apply to widely deployed CX-One V4.x (CX-Designer V3.x) — the stable version for editing NS series HMI projects.

  1. Officially Supported Operating Systems

✅ Officially validated & raccomandato

  1. Finestre 7 (32morso / 64morso; Professionale / Enterprise / Ultimate Edition)
  2. Finestre 8.1 (32morso / 64morso; System patch KB2919355 installation required)
  3. Finestre 10 (32morso / 64morso; Pro / Enterprise / LTSC all compatible)
  4. Finestre 11 (Only 64bit. No official certification; verified operable in practice, compatibility mode configuration mandatory)

❌ Officially Unsupported

Windows XP, Windows Vista: Only compatible with legacy CX-Designer V2. Not recommended for NS8-TV00B-ECV2 project editing, risk of corrupted projects and firmware download failures.

Original Windows 8: Poor compatibility, not recommended by OMRON.

All Windows Server systems (Server2016/2019 etc.): No official guarantee; partial environments may run with instability.

  1. Practical Operation Tips for Different OS (Industrial Site Pitfall Avoidance)

1) Windows7 64bit

⭐ Preferred OS with maximum stability

Rarely encounter communication errors or upload/download failures; standard configuration for industrial field computers.

2) Windows10 64bit (LTSC 2019/2021 Raccomandato)

Good compatibility; right-click installer → Run as administrator during installation.

Dopo l'installazione: Configure CX-Designer shortcut: Compatibility Mode Windows7 + Esegui come amministratore.

3) Windows11 64bit

⚠️ Not officially certified, works under practical testing

Common risks: Intermittent disconnection during USB program download, unstable FINS Ethernet communication.

Two mandatory settings:

  1. CX-Designer shortcut → Properties → Compatibility Mode: Windows7
  2. Disable Memory Integrity (Windows Security → Device Security → Core Isolation)
  3. Important Restrictions
  4. No standalone 64-bit CX-Designer executable. The software is a 32-bit program running via WOW64 subsystem on 64-bit Windows.
  5. Avoid compact/green portable CX-One releases; high risk of connection failure to NS8-TV00B-ECV2 and project damage.
  6. MacOS, Linux: No native support. Only operable via virtual machine (VMware running Win7/Win10).
  7. Software boundary distinction:

CX-Designer: NS Series (NS8-TV00B-ECV2)

Sysmac Studio: NA/NJ/NX, Cannot open NS projects

  1. Minimum Hardware Requirements

Display Resolution ≥1024×768

Full CX-One installation: ≥4GB free hard disk space

RAM ≥4GB (8GB or higher recommended under Win10/Win11)