| Segmento modello | Full Designation | Descrizione |
| 2981800 | Ordine n. | Contatto della Fenice global unique part number |
| PSR | PSR | Phoenix Contact PSR series safety relay (Programmable Safety Relay) |
| SCP | SCP | Funzione di sicurezza: dedicated for Emergency Stop / Safety Gate monitoring (Safety Control for E-Stop/Door) |
| 24DC | 24DC | Tensione di controllo: Ingresso 24 V CC |
| ESD | ESD | Function feature: Emergency Stop Delay |
| 4X1 | 4X1 | Configurazione dei contatti: 4 contatti (2 safety NO + 2 auxiliary NO), 1-channel safety input |
| 30 | 30 | Delay range: adjustable power-off delay 0.1s ~ 30s |
Applicazione principale: Single-channel safety relay for Emergency Stop and Safety Gate monitoring. It complies with safety rating SIL 3 / Cat.4 PL e, with 0.1–30s adjustable power-off delay. Suitable for protection scenarios of automated equipment requiring safety stop delay.
- Specifiche principali
| Categoria dei parametri | Specifica dettagliata | Osservazioni |
| Safety Performance | Safety Level: SIL 3 (CEI 61508) | Meets highest industrial safety requirements |
| Livello di prestazione: PL e, Categoria 4 (NELL'ISO 13849-1) | ||
| PFHd: 2.5×10⁻⁸/h | ||
| Caratteristiche di ingresso | Tensione di controllo: DC24V (19.2~28.8V) | Compatible with standard industrial 24V DC control systems |
| Corrente in ingresso: Max 40mA | ||
| Input Channel: 1 safety input (NC/NO optional) | ||
| Modalità di ripristino: Automatico / Manual selectable | ||
| Caratteristiche di uscita | Safety Contacts: 2 pcs N/O (Force-guided) | Force-guided safety contacts ensure fail-safe operation |
| Contatti ausiliari: 2 pcs N/O | ||
| Valutazione dei contatti: AC-15: 230V/2,5 A | ||
| DC-13: 24V/2,5 A | ||
| Max Switching Voltage: 250V CA/CC | ||
| Max Switching Current: 6UN | ||
| Delay Characteristics | Power-off delay: continuously adjustable 0.1s~30s | Adapt to different equipment stopping time requirements |
| Precisione dell'impostazione: ±10% | ||
| Caratteristiche fisiche | Dimensioni: W22.5mm × H99mm × D121mm | Single-channel width, consente di risparmiare spazio nell'armadio |
| Peso: ca. 0.22kg | ||
| Montaggio: 35Guida DIN da mm (IN 60715) | ||
| Cablaggio: Plug-in screw terminals | ||
| Caratteristiche ambientali | Temperatura operativa: -20~+60℃ | Industrial-grade environmental adaptability for harsh working conditions |
| Temperatura di conservazione: -40~+85℃ | ||
| Umidità: 5~95%UR (senza condensa) | ||
| Resistenza alle vibrazioni: 10~150Hz, 2G | ||
| Resistenza agli urti: 15G | ||
| Certificazioni di sicurezza | CE, UL, CSA, TÜV, ATEX | Conforme agli standard di sicurezza internazionali, globally applicable |
- Elenco degli accessori & Linee guida per l'installazione
3.1 Accessori standard
Safety relay unit ×1
Installation manual ×1
Terminal marking label ×1
Fixing clip ×2 (for DIN rail locking)
Delay adjustment screwdriver ×1 (special tool)
3.2 Precauzioni per l'installazione
- Requisiti di montaggio: Install on standard 35mm DIN rail; maintain ≥5mm clearance from adjacent modules for heat dissipation.
- Specifiche di cablaggio:
Circuito di controllo: Connect DC24V to A1(+)、A2(-)
Safety Input: Connect E-stop / safety gate contact to S11、S12 (NC contact preferred)
Uscita di sicurezza: Connect safety circuit (per esempio. bobina del contattore) A 13-14、23-24
Auxiliary Output: Connect alarm / indication circuit to 31-32、41-42
- Reset Setting:
Auto Reset: Automatically restore after power cycle
Ripristino manuale: Requires external reset signal or manual reset button operation
- Delay Adjustment: Use the dedicated screwdriver to adjust the front panel potentiometer to set 0.1–30s power-off delay.
- Cross-model & Cross-brand Replacement
4.1 Phoenix Contact Same Series Alternative Models
| Model No. | Differenza fondamentale | Scenario applicativo |
| 2981800 | 1 canale, 2 sicurezza + 2 contatti ausiliari, 0.1–30s delay | Standard E-stop / safety gate monitoring (modello attuale) |
| 2981801 | 1 canale, 2 sicurezza + 2 contatti ausiliari, 0.1–10s delay | Equipment with short stopping time |
| 2981802 | 1 canale, 2 sicurezza + 2 contatti ausiliari, 0.1–1s delay | Fast stop equipment |
| 2981810 | 2 canali, 4 sicurezza + 2 contatti ausiliari, no delay | Dual-channel redundant safety system |
| 2981820 | 1 canale, 2 sicurezza + 2 contatti ausiliari, with alarm output | System requiring alarm indication |
4.2 Cross-brand Equivalent Solutions
| Marca | Modello | Parametri chiave | Nota sulla compatibilità |
| Schneider | Zelio SR2P121BD | 1 canale, 2 contatti di sicurezza, 24A DC, Cat.4 | Funzione simile, different wiring layout |
| Siemens | 3SK1111-1AB30 | 1 canale, 2 contatti di sicurezza, 24A DC, SIL 3 | Different dimensions, cabinet rearrangement required |
| Omron | G9SA-321-T15 | 1 canale, 2 contatti di sicurezza, 24A DC, Cat.4 | Delay range 0.05–10s, slightly narrower |
| ABB | MSR1275 | 1 canale, 2 contatti di sicurezza, 24A DC, SIL 3 | Prezzo più alto, fully identical function |
| Weidmüller | DRM570730LT | 1 canale, 2 contatti di sicurezza, 24A DC, Cat.4 | Fixed 1s non-adjustable delay |
- Selezione & Linee guida per la sostituzione
5.1 Criteri di selezione fondamentali
✅ Safety Level Matching: Ensure required safety rating (SIL/PL/Cat.) does not exceed product capability (SIL 3 / Cat.4 PL e).
✅ I/O Requirement:
Ingresso: 1 channel sufficient; confirm NC or NO contact type.
Produzione: Verify 2 sicurezza + 2 auxiliary contacts meet control demands.
Capacità di contatto: Ensure load current ≤2.5A (AC-15/DC-13).
✅ Delay Requirement: Confirm 0.1–30s adjustable range covers equipment stopping time.
✅ Reset Mode: Select auto or manual reset according to operation needs.
✅ Environmental Adaptation: Operating temperature ≤60℃ and humidity within industrial standard range.
5.2 Aggiornamento & Opzioni di sostituzione
Option A: Same Series Function Upgrade
More channels: 2981800 → 2981810 (2 canali, 4 contatti di sicurezza)
Add alarm output: 2981800 → 2981820 (with alarm output)
Shorter delay: 2981800 → 2981801 (0.1–10 secondi) O 2981802 (0.1–1s)
Option B: Migrate from PSRclassic to PSRmini (Space Optimization)
Modello sostitutivo: 2981900 (PSRmini-SCP-24DC/ESD/4X1/30)
Vantaggio: Only 17.5mm width (5mm narrower), funzioni identiche, consente di risparmiare spazio nell'armadio.
Option C: Migrate from PSRclassic to PSRmodular (Espansione del sistema)
Soluzione: PSRmodular system + safety function modules
Vantaggio: Multi-channel expandable; integrates safety gate, E-stop, light curtain and other safety functions, suitable for complex safety systems.
5.3 Risoluzione dei problemi comuni
| Fenomeno di guasto | Possibile causa | Soluzione |
| Module indicator off | Control power disconnected or faulty | Check DC24V input, measure voltage within 19.2~28.8V |
| No safety output action | Safety input loop open | Check E-stop / safety gate contact wiring and loop continuity |
| Abnormal delay time | Improper potentiometer adjustment | Readjust with dedicated screwdriver; calibrate with timer recommended |
| Ripristinare l'errore | Incorrect reset mode setting | Verify auto/manual reset configuration and check reset signal |
| Contact adhesion | Overload current exceeded | Measure load current; add intermediate relay if necessary |
Contatto della Fenice 2981800 (PSR-SCP-24DC/ESD/4X1/30) is a single-channel safety relay with adjustable power-off delay, specially designed for emergency stop and safety gate monitoring, reaching the highest safety level SIL 3 / Cat.4 PL e. Its 22.5mm slim design and plug-in wiring facilitate installation and maintenance, while the 0.1–30s adjustable delay adapts to various equipment shutdown requirements. Durante la selezione, focus on safety rating, Configurazione degli I/O, delay range and reset mode. For upgrade, choose extended models in the same series or migrate to PSRmini / PSRmodular for space saving or system expansion.
Complete Model List of Phoenix Contact Safety Relays (Structured Classification)
- Model Naming Rule Overview
| Prefisso | Codice serie | Middle Code | Senso | Suffisso | Senso |
| PSR | Basic identifier for Phoenix safety relay | SCP | E-stop / Safety Gate dedicated | 24DC | Control voltage DC24V |
| PSR | Relè di sicurezza | SPP | Standard Safety Protection | ESD | Emergency Stop Delay (0.1-30S) |
| PSR | Relè di sicurezza | MC | Mini Compact | 4X1 | Contatto: 4 NO (2 sicurezza + 2 ausiliario) |
| PSR | Relè di sicurezza | SM | Monitoring Safety | 30 | Delay time range (0.1-30S) |
| PSR | Relè di sicurezza | UNI | Universal Configurable | PI | Push-in spring terminal |
| PSR | Relè di sicurezza | MM | Motion Monitoring | SC | Terminale a vite |
- PSRclassic Series (Standard Safety Relays)
2.1 E-Stop / Safety Gate (SCP Series)
| Modello | Ordine n. | Parametro fondamentale | Safety Level | Applicazione |
| PSR-SCP-24DC/ESD/4X1/30 | 2981800 | 1Ch, 2Safety+2Aux, 0.1-30s delay | SIL 3/Cat.4 PL e | Standard E-stop / Safety Gate |
| PSR-SCP-24DC/ESD/4X1/10 | 2981801 | 1Ch, 2Safety+2Aux, 0.1-10s delay | SIL 3/Cat.4 PL e | Short stop time equipment |
| PSR-SCP-24DC/ESD/4X1/1 | 2981802 | 1Ch, 2Safety+2Aux, 0.1-1s delay | SIL 3/Cat.4 PL e | Fast stop equipment |
| PSR-SCP-24DC/ESD/5X1/1X2/300 | 2981428 | 1/2Ch, 3Safety+1NC+2Aux, 0.1-300s delay | SIL 3/Cat.4 PL e | Long delay shutdown system |
| PSR-SCP-24UC/ESA4/3X1/1X2/B | 2963763 | 2Ch, 3Safety+1Aux, no delay | SIL 3/Cat.4 PL e | Dual-channel redundant safety system |
| PSR-SCP-24DC/MXF3/4X1/2X2/B | 2903257 | Multi-Ch, 4Safety+2Aux, 3 safety functions | SIL 3/Cat.4 PL e | Multi-function safety monitoring |
2.2 Standard Safety Function (SPP Series)
| Modello | Ordine n. | Parametro fondamentale | Safety Level | Applicazione |
| PSR-SPP-24DC/SDC4/2X1/B | 2901426 | 1Ch, 2Safety contacts, no delay | SIL 3/Cat.4 PL e | Basic safety loop |
| PSR-SPP-230AC/ESAM2/3X1/1X2/B | 2901431 | 1Ch, 3Safety+1Aux, AC230V | SIL 3/Cat.4 PL e | AC power supply system |
| PSR-SPP-24UC/URM/3X1/3X2 | 2901427 | 1Ch, 3Safety+3Aux, universal voltage | SIL 3/Cat.4 PL e | Multi-voltage compatible system |
| PSR-SPP-24DC/ESD/3X1/1X2/30 | 2981427 | 1Ch, 3Safety+1Aux, 0.1-30s delay | SIL 3/Cat.4 PL e | Delay-type safety system |
2.3 Light Curtain Monitoring (SCR Series)
| Modello | Ordine n. | Parametro fondamentale | Safety Level | Applicazione |
| PSR-SCR-24DC/3X1/1X2 | 2981500 | 2Ch, 3Safety+1Aux, dedicated for light curtain | SIL 3/Cat.4 PL e | Standard light curtain monitoring |
| PSR-SCR-24DC/4X1/2X2 | 2981501 | 2Ch, 4Safety+2Aux, dedicated for light curtain | SIL 3/Cat.4 PL e | Complex light curtain safety system |
| PSR-SCR-24DC/5X1/1X2 | 2981502 | 2Ch, 5Safety+1Aux, dedicated for light curtain | SIL 3/Cat.4 PL e | High-density safety output |
2.4 Two-Hand Control (SCT Series)
| Modello | Ordine n. | Parametro fondamentale | Safety Level | Applicazione |
| PSR-SCT-24DC/2X1/1X2 | 2981600 | 2Ch, 2Safety+1Aux, controllo a due mani | SIL 3/Cat.4 PL e | Standard two-hand operation |
| PSR-SCT-24DC/3X1/2X2 | 2981601 | 2Ch, 3Safety+2Aux, controllo a due mani | SIL 3/Cat.4 PL e | Complex two-hand operation |
- PSRmini Series (Micro Compact, 17.5larghezza mm)
3.1 Basic Safety Function (Serie MC)
| Modello | Ordine n. | Parametro fondamentale | Safety Level | Applicazione |
| PSR-MC32-3NO-1NC-24-230UC-SP | 2700525 | 1/2Ch, 3Safety+1NC, universal voltage | SIL 3/Cat.4 PL e | General safety monitoring |
| PSR-MC34-3NO-1DO-24DC-SP | 2700548 | 1/2Ch, 3Safety+1diagnostic output, DC24V | SIL 3/Cat.4 PL e | System with diagnostic output |
| PSR-MC45-3NO-1DO-24DC-SC | 1082024 | 1Ch, 3Safety+1diagnostic output, DC24V | SIL 3/Cat.4 PL e | Compact E-stop system |
| PSR-MC22-2NO-1NC-24DC-SP | 2700500 | 1Ch, 2Safety+1NC, DC24V | SIL 3/Cat.4 PL e | Small safety loop |
3.2 Safety Monitoring Module (MS Series)
| Modello | Ordine n. | Parametro fondamentale | Safety Level | Applicazione |
| PSR-MS21-1NO-1DO-24DC-SC | 2702192 | 1Ch, 1Safety+1digital output, DC24V | SIL 3/Cat.4 PL e | Safety controller expansion |
| PSR-MS31-2NO-1DO-24DC-SP | 2702200 | 1Ch, 2Safety+1digital output, DC24V | SIL 3/Cat.4 PL e | Safety status monitoring |
- PSRmodular Series (Modular Safety System)
4.1 Main Control Module
| Modello | Ordine n. | Parametro fondamentale | Safety Level | Applicazione |
| PSR-UNI-L-1X4NO-1DO-24DC-PI | 1487648 | 1/2Ch, 4Safety+1DO, configurable | SIL 3/Cat.4 PL e | Universal configurable safety system |
| PSR-UNI-L-2X4NO-2DO-24DC-PI | 1487649 | 2Ch, 8Safety+2DO, configurable | SIL 3/Cat.4 PL e | Complex safety system |
| PSR-UNI-L-1X2NO-1NC-1DO-24DC-PI | 1487650 | 1/2Ch, 2Safety+1NC+1DO | SIL 3/Cat.4 PL e | System with NC output |
4.2 Modulo di espansione
| Modello | Ordine n. | Parametro fondamentale | Safety Level | Applicazione |
| PSR-EXT-L-1X4NO-24DC-PI | 1487651 | 4-safety output expansion | SIL 3/Cat.4 PL e | Output expansion |
| PSR-EXT-L-1X2NO-1NC-24DC-PI | 1487652 | 2Safety+1NC output expansion | SIL 3/Cat.4 PL e | Mixed output expansion |
- PSRmotion Series (Motion Monitoring Safety Relay)
5.1 Zero Speed / OverSpeed Monitoring
| Modello | Ordine n. | Parametro fondamentale | Safety Level | Applicazione |
| PSR-MM25-1NO-2DO-24DC-SC | 2702355 | Sensorless zero-speed monitoring, 3-motore di fase | SIL 3/Cat.3 PL e | Motor zero-speed safety protection |
| PSR-MM35-1NO-2DO-24DC-SC | 2702356 | Overspeed monitoring, 3-motore di fase | SIL 3/Cat.3 PL e | Motor overspeed safety protection |
| PSR-MM45-1NO-2DO-24DC-SC | 2702357 | Zero-speed + overspeed dual monitoring, 3-motore di fase | SIL 3/Cat.3 PL e | Full motor speed monitoring |
5.2 Rotation Direction Monitoring
| Modello | Ordine n. | Parametro fondamentale | Safety Level | Applicazione |
| PSR-MD25-1NO-2DO-24DC-SC | 2702360 | Rotation direction monitoring, 3-motore di fase | SIL 3/Cat.3 PL e | Motor rotation direction safety control |
- Safety Coupling Relays (PSR-SCP/SPP Series)
| Modello | Ordine n. | Parametro fondamentale | Safety Level | Applicazione |
| PSR-SCP-24DC/FSP/1X1/1X2 | 2981700 | 1Safety+1Aux contact, coupling function | SIL 3 | Safety signal isolation |
| PSR-SCP-24DC/FSP2/2X1/1X2 | 2981701 | 2Safety+1Aux contact, coupling function | SIL 3 | Dual-channel safety isolation |
| PSR-PS21-1NO-1NC-24DC-SC | 2981702 | 1Safety+1NC contact, coupling function | SIL 3 | Safety signal switching |
- Confronto dei parametri di selezione dei tasti
| Categoria dei parametri | Key Index | Suggerimenti per la selezione |
| Safety Level | SIL 1-3, Cat.1-4, PL a-e | Determined by equipment risk assessment; max support SIL 3/Cat.4 PL e |
| Input Channel | 1 Canale / 2 Canale | Single channel for basic safety; dual channel for redundant safety |
| Configurazione dei contatti | Quantity of safety / contatti ausiliari | ≥2 safety contacts recommended; auxiliary contacts for alarm & indicazione |
| Tensione di controllo | DC24V / AC230V / Universale | Match on-site control system power supply |
| Function Feature | Delay / Diagnostic / Cross-circuit detection | E-stop requires delay; complex system needs diagnostic function |
| Larghezza di montaggio | 17.5mm / 22.5mm / 27.5mm | Choose PSRmini (17.5mm) for limited cabinet space |
| Tipo di cablaggio | Vite / Push-in spring | Push-in for frequent wiring; screw type for vibration environment |
- Note supplementari
8.1 Posizionamento in serie
PSRclassic: Standard type with complete functions, width starting from 22.5mm, suitable for conventional safety applications.
PSRmini: Micro compact type, only 17.5mm width, consente di risparmiare spazio nell'armadio.
PSRmodular: Configurable modular system, suitable for complex safety systems with expandable functions.
PSRmotion: Dedicated for motion monitoring, applicable to motor zero-speed / overspeed / rotation direction safety control.
8.2 Replacement Information
Old models are gradually phased out; priority recommended to select models manufactured after 2020.
Some models are discontinued; refer to Phoenix Contact official website or technical support for replacement.
8.3 Certificazione di sicurezza
Full series certified by CE, UL, CSA, TÜV, conforme alla CEI 61508 and EN ISO 13849-1.
Partial models with ATEX certification for explosive atmosphere applications.
Contattore,interruttore automatico,inverter solare,contatore elettrico,batterie solari