Phoenix 2981800 Safety Relay - Contattore,interruttore automatico,inverter solare,contatore elettrico,batterie solari

Wechat: +86-13184948252 Whatsapp: 0086-13811255435 E-mail: kent@bestcontactor.com

Di Contatto |

Phoenix 2981800 Safety Relay - Contattore,interruttore automatico,inverter solare,contatore elettrico,batterie solari

elettrico/

Phoenix 2981800 Safety Relay

  Model Segment Full Designation Description 2981800 Ordine n. Phoenix Contact global unique part number PSR PSR Phoenix Contact PSR series safety relay (Programmable Safety Relay) SCP SCP Safety function: dedicated for Emergency Stop / Safety Gate monitoring (Safety Control for E-Stop/Door) 24DC 24DC Control voltage: DC24V input ESD ESD Function feature: Emergency Stop Delay ...

  • Dettagli del prodotto

 

Segmento modelloFull DesignationDescrizione
2981800Ordine n.Contatto della Fenice global unique part number
PSRPSRPhoenix Contact PSR series safety relay (Programmable Safety Relay)
SCPSCPSafety function: dedicated for Emergency Stop / Safety Gate monitoring (Safety Control for E-Stop/Door)
24DC24DCTensione di controllo: Ingresso 24 V CC
ESDESDFunction feature: Emergency Stop Delay
4X14X1Configurazione dei contatti: 4 contatti (2 safety NO + 2 auxiliary NO), 1-channel safety input
3030Delay range: adjustable power-off delay 0.1s ~ 30s

Applicazione principale: Single-channel safety relay for Emergency Stop and Safety Gate monitoring. It complies with safety rating SIL 3 / Cat.4 PL e, with 0.1–30s adjustable power-off delay. Suitable for protection scenarios of automated equipment requiring safety stop delay.

  1. Specifiche principali
Categoria dei parametriSpecifica dettagliataOsservazioni
Safety PerformanceSafety Level: SIL 3 (CEI 61508)Meets highest industrial safety requirements
Livello di prestazione: PL e, Categoria 4 (EN ISO 13849-1)
PFHd: 2.5×10⁻⁸/h
Caratteristiche di ingressoTensione di controllo: DC24V (19.2~28.8V)Compatible with standard industrial 24V DC control systems
Corrente in ingresso: Max 40mA
Input Channel: 1 safety input (NC/NO optional)
Reset Mode: Automatico / Manual selectable
Caratteristiche di uscitaSafety Contacts: 2 pcs N/O (Force-guided)Force-guided safety contacts ensure fail-safe operation
Contatti ausiliari: 2 pcs N/O
Valutazione dei contatti: AC-15: 230V/2,5 A
DC-13: 24V/2,5 A
Max Switching Voltage: 250V CA/CC
Max Switching Current: 6UN
Delay CharacteristicsPower-off delay: continuously adjustable 0.1s~30sAdapt to different equipment stopping time requirements
Precisione dell'impostazione: ±10%
Caratteristiche fisicheDimensioni: W22.5mm × H99mm × D121mmSingle-channel width, consente di risparmiare spazio nell'armadio
Peso: ca. 0.22kg
Montaggio: 35Guida DIN da mm (IN 60715)
Cablaggio: Plug-in screw terminals
Caratteristiche ambientaliTemperatura operativa: -20~+60℃Industrial-grade environmental adaptability for harsh working conditions
Temperatura di conservazione: -40~+85℃
Umidità: 5~95%RH (senza condensa)
Resistenza alle vibrazioni: 10~150Hz, 2G
Resistenza agli urti: 15G
Safety CertificationsCE, UL, CSA, TÜV, ATEXConforme agli standard di sicurezza internazionali, globally applicable
  1. Elenco degli accessori & Linee guida per l'installazione

3.1 Accessori standard

Safety relay unit ×1

Installation manual ×1

Terminal marking label ×1

Fixing clip ×2 (for DIN rail locking)

Delay adjustment screwdriver ×1 (special tool)

3.2 Precauzioni per l'installazione

  1. Mounting Requirement: Install on standard 35mm DIN rail; maintain ≥5mm clearance from adjacent modules for heat dissipation.
  2. Specifiche di cablaggio:

Circuito di controllo: Connect DC24V to A1(+)、A2(-)

Safety Input: Connect E-stop / safety gate contact to S11S12 (NC contact preferred)

Safety Output: Connect safety circuit (per esempio. bobina del contattore) A 13-14、23-24

Auxiliary Output: Connect alarm / indication circuit to 31-32、41-42

  1. Reset Setting:

Auto Reset: Automatically restore after power cycle

Ripristino manuale: Requires external reset signal or manual reset button operation

  1. Delay Adjustment: Use the dedicated screwdriver to adjust the front panel potentiometer to set 0.1–30s power-off delay.
  2. Cross-model & Cross-brand Replacement

4.1 Phoenix Contact Same Series Alternative Models

Model No.Differenza fondamentaleScenario applicativo
29818001 canale, 2 sicurezza + 2 contatti ausiliari, 0.1–30s delayStandard E-stop / safety gate monitoring (modello attuale)
29818011 canale, 2 sicurezza + 2 contatti ausiliari, 0.1–10s delayEquipment with short stopping time
29818021 canale, 2 sicurezza + 2 contatti ausiliari, 0.1–1s delayFast stop equipment
29818102 canali, 4 sicurezza + 2 contatti ausiliari, no delayDual-channel redundant safety system
29818201 canale, 2 sicurezza + 2 contatti ausiliari, with alarm outputSystem requiring alarm indication

4.2 Cross-brand Equivalent Solutions

MarcaModelloParametri chiaveNota sulla compatibilità
SchneiderZelio SR2P121BD1 canale, 2 safety contacts, 24A DC, Cat.4Similar function, different wiring layout
Siemens3SK1111-1AB301 canale, 2 safety contacts, 24A DC, SIL 3Different dimensions, cabinet rearrangement required
OmronG9SA-321-T151 canale, 2 safety contacts, 24A DC, Cat.4Delay range 0.05–10s, slightly narrower
ABBMSR12751 canale, 2 safety contacts, 24A DC, SIL 3Prezzo più alto, fully identical function
WeidmüllerDRM570730LT1 canale, 2 safety contacts, 24A DC, Cat.4Fixed 1s non-adjustable delay

 

  1. Selezione & Linee guida per la sostituzione

5.1 Core Selection Criteria

✅ Safety Level Matching: Ensure required safety rating (SIL/PL/Cat.) does not exceed product capability (SIL 3 / Cat.4 PL e).

✅ I/O Requirement:

Ingresso: 1 channel sufficient; confirm NC or NO contact type.

Produzione: Verify 2 sicurezza + 2 auxiliary contacts meet control demands.

Capacità di contatto: Ensure load current ≤2.5A (AC-15/DC-13).

✅ Delay Requirement: Confirm 0.1–30s adjustable range covers equipment stopping time.

✅ Reset Mode: Select auto or manual reset according to operation needs.

✅ Environmental Adaptation: Operating temperature ≤60℃ and humidity within industrial standard range.

5.2 Aggiornamento & Opzioni di sostituzione

Option A: Same Series Function Upgrade

More channels: 2981800 → 2981810 (2 canali, 4 safety contacts)

Add alarm output: 2981800 → 2981820 (with alarm output)

Shorter delay: 2981800 → 2981801 (0.1–10s) O 2981802 (0.1–1s)

Option B: Migrate from PSRclassic to PSRmini (Space Optimization)

Modello sostitutivo: 2981900 (PSRmini-SCP-24DC/ESD/4X1/30)

Vantaggio: Only 17.5mm width (5mm narrower), funzioni identiche, consente di risparmiare spazio nell'armadio.

Option C: Migrate from PSRclassic to PSRmodular (System Expansion)

Soluzione: PSRmodular system + safety function modules

Vantaggio: Multi-channel expandable; integrates safety gate, E-stop, light curtain and other safety functions, suitable for complex safety systems.

5.3 Risoluzione dei problemi comuni

Fenomeno di guastoPossibile causaSoluzione
Module indicator offControl power disconnected or faultyCheck DC24V input, measure voltage within 19.2~28.8V
No safety output actionSafety input loop openCheck E-stop / safety gate contact wiring and loop continuity
Abnormal delay timeImproper potentiometer adjustmentReadjust with dedicated screwdriver; calibrate with timer recommended
Reset failureIncorrect reset mode settingVerify auto/manual reset configuration and check reset signal
Contact adhesionOverload current exceededMeasure load current; add intermediate relay if necessary

Contatto della Fenice 2981800 (PSR-SCP-24DC/ESD/4X1/30) is a single-channel safety relay with adjustable power-off delay, specially designed for emergency stop and safety gate monitoring, reaching the highest safety level SIL 3 / Cat.4 PL e. Its 22.5mm slim design and plug-in wiring facilitate installation and maintenance, while the 0.1–30s adjustable delay adapts to various equipment shutdown requirements. Durante la selezione, focus on safety rating, Configurazione degli I/O, delay range and reset mode. For upgrade, choose extended models in the same series or migrate to PSRmini / PSRmodular for space saving or system expansion.

Complete Model List of Phoenix Contact Safety Relays (Structured Classification)

  1. Model Naming Rule Overview
PrefissoCodice serieMiddle CodeSensoSuffissoSenso
PSRBasic identifier for Phoenix safety relaySCPE-stop / Safety Gate dedicated24DCControl voltage DC24V
PSRSafety RelaySPPStandard Safety ProtectionESDEmergency Stop Delay (0.1-30S)
PSRSafety RelayMCMini Compact4X1Contatto: 4 NO (2 sicurezza + 2 ausiliario)
PSRSafety RelayMSMonitoring Safety30Delay time range (0.1-30S)
PSRSafety RelayUNIUniversal ConfigurablePIPush-in spring terminal
PSRSafety RelayMMMotion MonitoringSCTerminale a vite
  1. PSRclassic Series (Standard Safety Relays)

2.1 E-Stop / Safety Gate (SCP Series)

ModelloOrdine n.Core ParameterSafety LevelApplicazione
PSR-SCP-24DC/ESD/4X1/3029818001Ch, 2Safety+2Aux, 0.1-30s delaySIL 3/Cat.4 PL eStandard E-stop / Safety Gate
PSR-SCP-24DC/ESD/4X1/1029818011Ch, 2Safety+2Aux, 0.1-10s delaySIL 3/Cat.4 PL eShort stop time equipment
PSR-SCP-24DC/ESD/4X1/129818021Ch, 2Safety+2Aux, 0.1-1s delaySIL 3/Cat.4 PL eFast stop equipment
PSR-SCP-24DC/ESD/5X1/1X2/30029814281/2Ch, 3Safety+1NC+2Aux, 0.1-300s delaySIL 3/Cat.4 PL eLong delay shutdown system
PSR-SCP-24UC/ESA4/3X1/1X2/B29637632Ch, 3Safety+1Aux, no delaySIL 3/Cat.4 PL eDual-channel redundant safety system
PSR-SCP-24DC/MXF3/4X1/2X2/B2903257Multi-Ch, 4Safety+2Aux, 3 safety functionsSIL 3/Cat.4 PL eMulti-function safety monitoring

2.2 Standard Safety Function (SPP Series)

ModelloOrdine n.Core ParameterSafety LevelApplicazione
PSR-SPP-24DC/SDC4/2X1/B29014261Ch, 2Safety contacts, no delaySIL 3/Cat.4 PL eBasic safety loop
PSR-SPP-230AC/ESAM2/3X1/1X2/B29014311Ch, 3Safety+1Aux, AC230VSIL 3/Cat.4 PL eAC power supply system
PSR-SPP-24UC/URM/3X1/3X229014271Ch, 3Safety+3Aux, universal voltageSIL 3/Cat.4 PL eMulti-voltage compatible system
PSR-SPP-24DC/ESD/3X1/1X2/3029814271Ch, 3Safety+1Aux, 0.1-30s delaySIL 3/Cat.4 PL eDelay-type safety system

2.3 Light Curtain Monitoring (SCR Series)

ModelloOrdine n.Core ParameterSafety LevelApplicazione
PSR-SCR-24DC/3X1/1X229815002Ch, 3Safety+1Aux, dedicated for light curtainSIL 3/Cat.4 PL eStandard light curtain monitoring
PSR-SCR-24DC/4X1/2X229815012Ch, 4Safety+2Aux, dedicated for light curtainSIL 3/Cat.4 PL eComplex light curtain safety system
PSR-SCR-24DC/5X1/1X229815022Ch, 5Safety+1Aux, dedicated for light curtainSIL 3/Cat.4 PL eHigh-density safety output

2.4 Two-Hand Control (SCT Series)

ModelloOrdine n.Core ParameterSafety LevelApplicazione
PSR-SCT-24DC/2X1/1X229816002Ch, 2Safety+1Aux, two-hand controlSIL 3/Cat.4 PL eStandard two-hand operation
PSR-SCT-24DC/3X1/2X229816012Ch, 3Safety+2Aux, two-hand controlSIL 3/Cat.4 PL eComplex two-hand operation
  1. PSRmini Series (Micro Compact, 17.5mm Width)

3.1 Basic Safety Function (MC Series)

ModelloOrdine n.Core ParameterSafety LevelApplicazione
PSR-MC32-3NO-1NC-24-230UC-SP27005251/2Ch, 3Safety+1NC, universal voltageSIL 3/Cat.4 PL eGeneral safety monitoring
PSR-MC34-3NO-1DO-24DC-SP27005481/2Ch, 3Safety+1diagnostic output, DC24VSIL 3/Cat.4 PL eSystem with diagnostic output
PSR-MC45-3NO-1DO-24DC-SC10820241Ch, 3Safety+1diagnostic output, DC24VSIL 3/Cat.4 PL eCompact E-stop system
PSR-MC22-2NO-1NC-24DC-SP27005001Ch, 2Safety+1NC, DC24VSIL 3/Cat.4 PL eSmall safety loop

3.2 Safety Monitoring Module (MS Series)

ModelloOrdine n.Core ParameterSafety LevelApplicazione
PSR-MS21-1NO-1DO-24DC-SC27021921Ch, 1Safety+1digital output, DC24VSIL 3/Cat.4 PL eSafety controller expansion
PSR-MS31-2NO-1DO-24DC-SP27022001Ch, 2Safety+1digital output, DC24VSIL 3/Cat.4 PL eSafety status monitoring
  1. PSRmodular Series (Modular Safety System)

4.1 Main Control Module

ModelloOrdine n.Core ParameterSafety LevelApplicazione
PSR-UNI-L-1X4NO-1DO-24DC-PI14876481/2Ch, 4Safety+1DO, configurableSIL 3/Cat.4 PL eUniversal configurable safety system
PSR-UNI-L-2X4NO-2DO-24DC-PI14876492Ch, 8Safety+2DO, configurableSIL 3/Cat.4 PL eComplex safety system
PSR-UNI-L-1X2NO-1NC-1DO-24DC-PI14876501/2Ch, 2Safety+1NC+1DOSIL 3/Cat.4 PL eSystem with NC output

4.2 Modulo di espansione

ModelloOrdine n.Core ParameterSafety LevelApplicazione
PSR-EXT-L-1X4NO-24DC-PI14876514-safety output expansionSIL 3/Cat.4 PL eOutput expansion
PSR-EXT-L-1X2NO-1NC-24DC-PI14876522Safety+1NC output expansionSIL 3/Cat.4 PL eMixed output expansion
  1. PSRmotion Series (Motion Monitoring Safety Relay)

5.1 Zero Speed / OverSpeed Monitoring

ModelloOrdine n.Core ParameterSafety LevelApplicazione
PSR-MM25-1NO-2DO-24DC-SC2702355Sensorless zero-speed monitoring, 3-motore di faseSIL 3/Cat.3 PL eMotor zero-speed safety protection
PSR-MM35-1NO-2DO-24DC-SC2702356Overspeed monitoring, 3-motore di faseSIL 3/Cat.3 PL eMotor overspeed safety protection
PSR-MM45-1NO-2DO-24DC-SC2702357Zero-speed + overspeed dual monitoring, 3-motore di faseSIL 3/Cat.3 PL eFull motor speed monitoring

5.2 Rotation Direction Monitoring

ModelloOrdine n.Core ParameterSafety LevelApplicazione
PSR-MD25-1NO-2DO-24DC-SC2702360Rotation direction monitoring, 3-motore di faseSIL 3/Cat.3 PL eMotor rotation direction safety control
  1. Safety Coupling Relays (PSR-SCP/SPP Series)
ModelloOrdine n.Core ParameterSafety LevelApplicazione
PSR-SCP-24DC/FSP/1X1/1X229817001Safety+1Aux contact, coupling functionSIL 3Safety signal isolation
PSR-SCP-24DC/FSP2/2X1/1X229817012Safety+1Aux contact, coupling functionSIL 3Dual-channel safety isolation
PSR-PS21-1NO-1NC-24DC-SC29817021Safety+1NC contact, coupling functionSIL 3Safety signal switching
  1. Confronto dei parametri di selezione dei tasti
Categoria dei parametriKey IndexSuggerimenti per la selezione
Safety LevelSIL 1-3, Cat.1-4, PL a-eDetermined by equipment risk assessment; max support SIL 3/Cat.4 PL e
Input Channel1 Canale / 2 CanaleSingle channel for basic safety; dual channel for redundant safety
Configurazione dei contattiQuantity of safety / contatti ausiliari≥2 safety contacts recommended; auxiliary contacts for alarm & indicazione
Tensione di controlloDC24V / AC230V / UniversaleMatch on-site control system power supply
Function FeatureDelay / Diagnostic / Cross-circuit detectionE-stop requires delay; complex system needs diagnostic function
Larghezza di montaggio17.5mm / 22.5mm / 27.5mmChoose PSRmini (17.5mm) for limited cabinet space
Tipo di cablaggioVite / Push-in springPush-in for frequent wiring; screw type for vibration environment
  1. Note supplementari

8.1 Posizionamento in serie

PSRclassic: Standard type with complete functions, width starting from 22.5mm, suitable for conventional safety applications.

PSRmini: Micro compact type, only 17.5mm width, consente di risparmiare spazio nell'armadio.

PSRmodular: Configurable modular system, suitable for complex safety systems with expandable functions.

PSRmotion: Dedicated for motion monitoring, applicable to motor zero-speed / overspeed / rotation direction safety control.

8.2 Replacement Information

Old models are gradually phased out; priority recommended to select models manufactured after 2020.

Some models are discontinued; refer to Phoenix Contact official website or technical support for replacement.

8.3 Safety Certification

Full series certified by CE, UL, CSA, TÜV, conforme alla CEI 61508 and EN ISO 13849-1.

Partial models with ATEX certification for explosive atmosphere applications.

Prec:

Prossimo:

Lascia una risposta

Lasciate un messaggio