Contatto della Fenice PSR-SPP-24DC/ESD/4X1/30 Relè di sicurezza (Articolo n.: 2981813)
Marca: Contatto della Fenice
- Scomposizione del codice modello
`PSR-SPP-24DC/ESD/4X1/30`
- PSR: Safety relay of PSRclassic series
- SPP: Push-in spring cage terminals (tool-free pluggable wiring)
- 24DC: Control coil rated voltage DC24V
- ESD: Electrical Switch-off Delay (dropout delay function)
- 4X1: 4 safety normally-open contacts (2 istantaneo, 2 delayed)
- 30: Adjustable delay range: 0.1s ~ 30s
- Core Safety Ratings & Standard di conformità
Forcibly guided mechanical contacts: CEI/EN 61810-3
Machinery safety: Cat.4 / PL e (NELL'ISO 13849-1)
Functional safety: SIL 3 / SILCL3 (CEI 62061 / CEI 61508)
Applicable safety devices: Emergency stop pushbuttons, safety door interlock switches, safety light curtains
- Key Electrical Specifications
3.1 Control Input (Bobina)
Tensione nominale: DC24V, permissible operating range 0.85~1.1Un
Corrente operativa: 75mA
Response actuation time: 150SM
Reset recovery time: 330SM
3.2 Output Contacts (4 N/O Normally Open)
Instantaneous contacts: 2 pz, release time ≈20ms
Delayed contacts: 2 pz, ritardo regolabile: 0.1~30 seconds
Materiale di contatto: AgSnO₂
Corrente nominale continua: 6UN / 250V CA/CC
Massimo. power for resistive loads: 1500VA (AC250V), 144W (DC24V)
Minimum switching capacity: 0.4W, minimum carry current 25mA
Vita utile meccanica: 10 million switching cycles
3.3 Cablaggio & Montaggio
Terminali: Pluggable push-in spring cage terminals (SPP)
Montaggio: Guida DIN standard da 35 mm
Classe di protezione: IP20 (for cabinet internal installation only)
Peso: ca. 0.24kg
- Caratteristiche funzionali
- 2-channel monitoring: Supports single/dual-channel safety circuit connection, compatible with dual-channel E-stop and safety door interlocks
- Two reset modes: Ripristino automatico / manually monitored reset (with feedback loop)
- Dropout delayed output: Delayed power cut-off for drives after equipment shutdown, ideal for scenarios requiring inertia coast-down of motors and slow stop of conveyors
- Tamper-proof design: Sealable delay adjustment knob to prevent unauthorized on-site modification of delay settings
- Built-in self-diagnosis: Integrated diagnostic LEDs to rapidly identify power supply faults, safety circuit open-circuits and reset failures
- Scenari applicativi tipici
E-stop safety circuits for machine tools, injection molding machines and stamping equipment
Safety guard door monitoring for automated production lines
Signal evaluation for safety light curtains in robot workcells
Delayed power disconnection for conveyor and roller motors with inertia stop
- Cross-Series Alternative Comparison
| Modello | Articolo n. | Tipo di terminale | Intervallo di ritardo | Configurazione dei contatti |
| PSR-SPP-24DC/ESD/4X1/30 | 2981813 | Push-in spring cage | 0.1~30s | 2 instantaneous N/O + 2 delayed N/O |
| PSR-SCP-24DC/ESD/4X1/30 | 2981800 | Terminale a vite | 0.1~30s | 2 instantaneous N/O + 2 delayed N/O |
- Appalti & Stock Information
Member price on official domestic store: ca. Città di New York 3,475; standard minimum order quantity 1 piece per carton; industrial automation spare parts kept in regular stock.
Full Application Scenarios of PSR-SPP-24DC/ESD/4X1/30 (Item No.2981813)
Core advantages of this model: 2-channel safety monitoring + 2 instantaneous safety contacts + 2 dropout delay contacts (0.1~30s) + Cat.4/PL e/SIL3. It is specially designed for safety conditions where equipment carries large rotational inertia and cannot be fully powered off instantly. All scenarios support monitoring of three categories of safety components: E-stop buttons, safety door interlocks and safety light curtains.
- Basic Safety Signal Monitoring (Universal for All Automated Equipment)
1.1 Dual-channel Emergency Stop Circuit Monitoring
Dual-channel E-stop detection for machine tools, standalone production line units, robots and packaging machinery
Supports manually monitored reset / ripristino automatico, with detection of short-circuits and open-circuit faults in E-stop wiring
Instantaneous contacts cut off main drives immediately; delayed contacts control slow stop of auxiliary loads including fans, conveyors and lubrication systems
1.2 Equipment Safety Guard Door Monitoring
Dual-channel monitoring of safety door interlocks for stamping machines, injection molders, centri di lavoro, robot enclosures and automated modules
Main spindle/servo power is instantly cut off when the door opens; cooling, chip removal and conveyor systems keep running with delay until full inertia stop before disconnection
Detects cross-wire short-circuits in door switch wiring, fully compliant with machinery safety standards
1.3 Safety Light Curtain Signal Evaluation
Safety circuits for light curtains on stamping, bending, robotic loading/unloading and packaging lines
Main motor cuts off instantly upon curtain obstruction; delayed contacts operate discharge roller conveyors to clear residual materials
Built-in cross-circuit fault diagnosis, meeting the highest PL e safety rating requirements
- Core Featured Scenarios (Relying on ESD Dropout Delay Function, Exclusive Strength of This Model)
2.1 Trasmettere & Logistics Equipment (Belt Conveyors, Roller Lines, Stacker Cranes)
Trasportatori a nastro, roller sorting lines, automated warehouse roller conveyors, packaging transport lines
Operating logic: After E-stop or door opening, main drive cuts off instantly; rollers remain running for an adjustable delay of 0.5~10s to clear materials on belts, avoiding material extrusion, machine jamming and belt tearing
Widely applied in food packaging, warehousing logistics and lithium battery assembly lines
2.2 Rotational Inertia Load Equipment (Tifosi, Centrifugal Machines, Miscelatori, Extruder Screws)
Injection extruders, pelletizing screws, high-speed agitators, centrifugal dehydrators, high-power cooling fans, compressori d'aria
Operating logic: Main spindles carry massive inertia; instant power-off risks screw fracture and impeller damage. Main power is cut off instantly, while lubrication and cooling fans keep operating for 3~30s until rotational speed drops to zero before auxiliary circuits are disconnected
Standard configuration for plastic extrusion, chemical mixing, lithium coating and rubber pelletizing industries
2.3 Web Winding, Slitting & Attrezzature per la stampa
Film slitters, paper printing machines, non-woven winders, lithium battery electrode slitters
After safety trigger, winding/unwinding servos cut off instantly; tension rollers keep running for 2~8s to prevent sudden web breakage and flying material hazards to operators
2.4 Macchine utensili & Metal Processing Equipment
CNC machining centers, CNC lathes, punch presses, bending machines, smerigliatrici, macchine da taglio laser:
- Instant cut-off of spindle servos when safety door opens or E-stop is activated
- Delayed contacts continuously run cutting fluid pumps, cooling fans and chip conveyors; all power disconnected upon delay expiry
- Prevents damage to cutting tools and spindle bearings caused by rapid shutdown of hot spindles without cooling
2.5 Robot Workcells & Automated Assembly Units
6-axis robots, gantry manipulators, loading/unloading modules, welding stations:
Robot servos cut off instantly upon trigger from enclosure safety doors or area light curtains
Delayed control for slow stop of conveyors, fixture air blow dust removal and cooling fans
Compliant with safety specifications for auto parts and 3C electronics assembly
2.6 Cibo, Farmaceutico & Packaging Equipment
Macchine riempitrici, macchine sigillatrici, horizontal form fill seal packaging machines, pharmaceutical sorting equipment:
Main transmission cuts off instantly when safety guards are opened
Discharge conveyors run delayed to clear food/medicine bottles, avoiding mold jamming and cross-contamination from accumulated materials
- Summary of Complete Sets of Applications by Industry
- Industria delle macchine utensili: CNC equipment, punch presses, bending machines, taglierine laser, macchine per lo stampaggio ad iniezione
- Logistica & Warehousing Industry: Belt conveying, roller sorting, automated warehouse stacker cranes
- Gomma, Plastica & Industria chimica: Extrusion pelletizing, high-speed mixing, film slitting machines
- Robotica & Automazione: Saldatura, loading/unloading, enclosure safety protection for 3C assembly robots
- Lithium New Energy Industry: Safety monitoring for electrode slitting, coating and cell assembly lines
- Cibo & Industria farmaceutica: Safety door + light curtain monitoring for filling, packaging and sorting equipment
- General Fan & Air Compressor Station: Safety circuits for maintenance access doors of high-power fans and water chillers
- Model Selection Guidance (Why Choose This Model Over Standard Non-Delayed Safety Relays)
- Standard safety relays cut off all contacts simultaneously; inertia loads easily suffer equipment damage and material jamming
- This model separates instantaneous safety circuits and delayed auxiliary circuits, balancing operator personal safety and equipment protection
- Push-in spring cage terminals (SPP) enable tool-free wiring and higher mass assembly efficiency in control cabinets
- Sealable delay adjustment knob prevents equipment faults caused by unauthorized on-site personnel shortening delay time
Contattore,interruttore automatico,inverter solare,contatore elettrico,batterie solari
















NH42-63-318x560.png)




