Phoenix MCR-C-UI-UI-DCI-2810913 - Contattore,interruttore automatico,inverter solare,contatore elettrico,batterie solari

Wechat: +86-13184948252 Whatsapp: 0086-13811255435 E-mail: kent@bestcontactor.com

Di Contatto |

Phoenix MCR-C-UI-UI-DCI-2810913 - Contattore,interruttore automatico,inverter solare,contatore elettrico,batterie solari

elettrico/

Phoenix MCR-C-UI-UI-DCI-2810913

Model Code Breakdown Explanation Code Segment Definition MCR Base series identifier: Modular Current/Voltage Converter, series of 3-way isolated signal conditioners C Dimension specification: Larghezza standard (17.5mm), differs from MINI MCR series (6.2mm/12.5mm) UI Input type: Universal Input, supports 0–10V voltage & 4–20mA current signals UI Output type: Universal Output, supports 0–10V voltage & 4–20mA current ...

  • Dettagli del prodotto
  1. Model Code Breakdown Explanation
Segmento di codiceDefinizione
MCRBase series identifier: Modular Current/Voltage Converter, series of 3-way isolated signal conditioners
CDimension specification: Larghezza standard (17.5mm), differs from MINI MCR series (6.2mm/12.5mm)
UITipo di ingresso: Universal Input, supports 0–10V voltage & 4–20mA current signals
UITipo di uscita: Universal Output, supports 0–10V voltage & 4–20mA current signals
DCICaratteristica funzionale: DC Isolation; built-in DC/DC converter realizes 3-port isolation among Input / Produzione / Alimentazione elettrica
2810913Unique order number: Ufficiale Fenice part number for procurement & inventory management
  1. Core Specification Data Sheet

2.1 Basic Electrical Specifications

ParametroValoreRemark
Isolation Type3-way isolation (Ingresso / Produzione / Energia)Withstand voltage test: In-Out:1.5kV CA; Power-Signal:1kV CA (50Hz, 60S)
Input Signal0–10V DC / 4–20mA DCMassimo. ingresso:30V / 50mA
Output Signal0–10V DC / 4–20mA DCMassimo. produzione:15V / 30mA
Transmission Error≤0.1% FSHigh-precision signal conversion
Alimentazione elettrica18–30V DCNominal 24V DC; No-load current <30mA
Consumo energetico≤900mWUnder rated operating condition
Cut-off Frequency30Hz3dB point, effectively suppress high-frequency interference
Step Response11SM (10%–90%)Fast signal tracking performance

2.2 Meccanico & Specifiche ambientali

ParametroValoreRemark
Dimensione complessivaW17.5mm × H99mm × D114.5mmDIN rail mounting for space saving
MontaggioGuida DIN standard da 35 mmArbitrary installation orientation available
TerminazionePlug-in screw terminal (COMBICON)Stripping length:8mm, M3 screw thread
Cable SizeSolid/Flexible:0.2–2,5 mm² (AWG24–14)Compatible with various industrial cables
Temp. operativa.-20°C~+65°CWide temperature range for industrial environment
Ingress RatingIP20Indoor cabinet installation only
Peso149.4G (with package)Lightweight for easy mounting

2.3 Certificazione & Conformità

CertificazioneStandardRemark
CEIN 61000-6-2 / IN 61000-6-4EMC compliant
UL RecognizedUL 508Class I Div.2 Groups A-D; Class I Zone2 Group IIC
Eco-certificateEU RoHS / China RoHSEFUP-50 (50-year service life for environmental compliance)
HS Code85437090For customs clearance in international trade
  1. Full Series Part Number List (MCR-C-UI-UI-DCI Family)
Ordine n.ModelloCaratteristica specialeApplicazione tipica
2810913MCR-C-UI-UI-DCIVersione standard, factory preset 0–10V/0–10VGeneral industrial signal isolation & conversion
2810939MCR-C-UI-UI-DCI-NCNC = No CalibrationFixed application without on-site calibration
2811284MACX MCR-UI-UIUpgraded replacement modelNew generation with improved performance
2810915MCR-C-UI-UI-450-DCIHigh-load type, Massimo. output load ≤450ΩLong-distance signal transmission & high-load occasions
2810941MCR-C-UI-UI-450-DCI-NCHigh-load without calibrationHigh-load fixed installation without trimming
  1. Cross-reference: Obsoleto & Competitor Replacement List

4.1 Internal Phoenix Replacement

Vecchio modelloModello sostitutivoUpgrade Highlights
MCR-C-UI-UI-DCI (2810913)MACX MCR-UI-UI (2811284)Narrower width(12.5mm), lower power draw, risposta più rapida
MCR-C-UI-UI-450-DCIMACX MCR-UI-UI-450Identical function with compact footprint

4.2 Cross-brand Equivalent Comparison

Phoenix ModelEquivalente a SchneiderEquivalente SiemensDifferenze fondamentali
MCR-C-UI-UI-DCI (2810913)FOXboro IMT25SITRANS P DS IIIFenice:3-way isolation,1.5kV withstand, conveniente
1kV isolation,15ms response1.2kV isolation,12ms response
  1. Ambiente applicativo & Casi di settore

5.1 Applicazioni consigliate

  1. Automazione industriale: Signal isolation between PLC and field sensors/actuators to eliminate ground loop interference
  2. Industria di processo: Safe transmission of analog signals for chemical, farmaceutico, cibo & beverage in explosion-proof environment
  3. New Energy: Pitch control monitoring for wind turbine, PV inverter signal acquisition, substation remote signaling renovation
  4. Transito ferroviario: Signal isolation for train control & on-board equipment with superior EMC resistance
  5. Trattamento delle acque: PLC automation system for municipal water plant, safe integration of process sensor signals

5.2 Not Recommended Applications

  1. Intrinsically Safe hazardous area (Select MCR-EX intrinsic safety series instead)
  2. Ultra-low temp (<-20°C) or ultra-high temp (>+65°C) ambiente
  3. Special project requiring isolation voltage higher than 1.5kV
  4. High-frequency signal processing above 30Hz bandwidth

5.3 Casi applicativi tipici

Caso 1: Automotive Production Line

Applicazione: Signal isolation for welding robot controller & pressure transmitter

Problema: Severe EMI from welding current causes distorted sensor readings

Soluzione: Install MCR-C-UI-UI-DCI isolator, 1.5kV galvanic isolation, conversion error<0.1% to guarantee precise pressure control

Caso 2: Municipal Wastewater Treatment Plant

Applicazione: Conversion & isolation between pH sensor and PLC analog input

Problema: Different equipment ground potential drift leads to unstable output

Soluzione: Adopt 3-port isolation to cut ground loop; convert 0–10V sensor signal to standard 4–20mA for up to 1000m long-distance cabling

  1. Suggerimenti per la selezione & Regole di riferimento rapido

Regole di selezione rapida

  1. Identificazione del modello: MCR-C=standard size; UI=universal I/O; DCI=DC galvanic isolation
  2. Specifiche chiave: 3-way isolation @1.5kV, 0–10V/4–20mA, 0.1%FS accuracy,11ms step response
  3. Opzione di aggiornamento: Compact space saving → MACX MCR series PN:2811284
  4. Application Rule: Ground loop trouble →3-port isolation; long cable run →4–20mA output
  5. Air Shipment Compliance & CE Certification Summary

7.1 Air Transport Compliance

Lithium Battery Check: No built-in lithium cell, classified as non-restricted goods without special shipping marking

Transport Classification: Complies with IATA DGR Class9, acceptable as general cargo

Imballaggio: Original factory carton preferred; ESD bag protection recommended

7.2 CE Certification Info

Standard applicabili: EN61000-6-2 (Immunity), EN61000-6-4 (Emission)

DOC Download: EU Declaration of Conformity available on Phoenix official website (Doc n.:083097087_04_DoC_EU.pdf)

Valid Scope: All EU member states & regions accepting CE marking

  1. Guida alla risoluzione dei problemi
Sintomo di guastoRoot CauseRimedio
Power LED off1. Missing power or reverse polarity1. Rewire DC supply with correct polarity
2. Supply out of 18–30V range2. Measure & adjust input to rated 24V DC
No output variation1. Improper input wiring1. Verify input wiring & signal type
2. Wrong DIP switch setting2. Reconfigure DIP switches
3. Load out of specification3. Voltage output ≥10kΩ; Current output ≤500Ω
Fluctuating output1. Input signal interfered1. Single-point grounding for shield cable
2. Excessive power supply ripple2. Add power filter
3. Poor module earthing3. Secure module chassis ground
Excessive conversion error1. Zero/Span drift1. Re-trim Zero & Span (±2% adjustable)
2. Ambient temp out of rated range2. Improve cabinet ventilation
3. Mismatched load impedance3. Adjust load to specified range

Phoenix MCR‑C‑UI‑UI‑DCI (2810913) On-site Installation Manual

  1. Safety Precaution (Mandatory Reading)

Classe di protezione: IP20, indoor dry cabinet installation only

Withstand Voltage: In-Out 1.5kV AC/60s; Power-Signal 1kV AC/60s, overvoltage withstand test prohibited

Protezione ESD: Static-sensitive component; discharge body static by touching grounded metal before handling

Zona pericolosa: Suitable for Zone2 / Class I Div.2 only; MCR‑EX IS series for Intrinsically Safe location

Alimentazione elettrica:18–30V DC (Nominal 24V DC); reverse polarity will permanently damage unit, confirm polarity prior to power-up

  1. Unpacking & Ispezione

2.1 Lista imballaggio

Isolation amplifier MCR‑C‑UI‑UI‑DCI (2810913) ×1

This installation manual ×1

Factory test certificate ×1

2.2 Visual Check

No housing crack, intact snap latch, non-deformed & rust-free terminals

Confirm model & part No.: MCR‑C‑UI‑UI‑DCI / 2810913

  1. Ambiente di installazione & Clearance Requirement

3.1 Ambient Condition

Temp. operativa: -20°C~+65°C

Temp. di conservazione: -25°C~+70°C

Umidità:10%~90% non-condensing

Min.30cm clearance away from strong EMI source (VFD, large motor, trasformatore)

3.2 Spaziatura di montaggio

Mount: Guida DIN standard da 35 mm (EN60715), any mounting direction allowed

Side gap between adjacent modules ≥5mm

Vertical top/bottom clearance ≥20mm for heat dissipation & manutenzione

Install at upper/middle cabinet position; avoid dusty bottom compartment

  1. DIN Rail Mount & Dismount Steps

4.1 Montaggio

  1. Clean DIN rail from grease & burr, ensure reliable rail grounding
  2. Flip upward the orange top latch of module
  3. Hook upper notch onto top edge of DIN rail then press down module bottom
  4. Audible click sound confirms locked & fixed without wobble

4.2 Dismounting

  1. Cut off module power & all field signals first; no live removal allowed
  2. Lift orange release latch upward
  3. Lift module bottom upward to detach from DIN rail then take out
  4. Definizione del terminale & Specifiche di cablaggio

5.1 Terminal Pinout (Left to Right)

Perno n.MarcaturaDefinizioneNota
1.1IN UVoltage Input (0–10 V)Signal Positive
1.2IN IIngresso corrente (4–20mA)Signal Positive
1.3GND 1Input CommonSignal Negative
2.1OUT UVoltage Output (0–10 V)Signal Positive
2.2OUT ICurrent Output (4–20mA)Signal Positive
2.3GND 2Output CommonSignal Negative
3.124A DCPositive Power18–30V DC
3.2GNDNegative PowerSupply Ground

5.2 Wiring Standard

Cable strip length:8mm (too long → short circuit; too short → poor contact)

Dimensione del conduttore: Solid/Flexible 0.2–2.5mm² (AWG24–14); ferrules required for stranded flexible wire

Screw torque:0.5~0.6N·m for M3 terminal, avoid over-tightening thread slip

Shield cable: Single-end cabinet grounding (transmitter end floating) to eliminate ground loop

5.3 Typical Wiring Examples

Ex1: 4–20mA Input →4–20mA Output (2-wire transmitter)

Transmitter + →1.2(IN I)

Transmitter − →1.3(GND1)

2.2(OUT I) →PLC AI+

2.3(GND2) →PLC AI−

3.1→24V DC+;3.2→24V DC−

Ex2:0–10V Input→0–10V Output (Voltage sensor)

Sensor +→1.1(IN U)

Sensor −→1.3(GND1)

2.1(OUT U)→PLC AI+

2.3(GND2)→PLC AI−

3.1→24V DC+;3.2→24V DC−

  1. DIP Switch Configuration (Factory preset for 2810913:0–10V/0–10V)

6.1 Switch Location (Side housing; remove cover to access)

S1: Input Configuration

S1‑1:OFF=0–10V; ON=4–20mA

S1‑2:OFF=Unipolar; ON=Bipolar(±5V/±10V)

S2: Configurazione dell'uscita

S2‑1:OFF=0–10V; ON=4–20mA

S2‑2:OFF=Unipolar; ON=Bipolar(±5V/±10V)

6.2 Factory Default (2810913)

S1:OFF/OFF (Unipolar 0–10V Input)

S2:OFF/OFF (Unipolar 0–10V Output)

6.3 Setting Procedure

  1. Cut off power supply then remove 2 cross-head screws to open cover
  2. Toggle DIP switches as required with fully seated position
  3. Refit housing & tighten screws before power-on test
  4. Power-up & Messa in servizio

7.1 Ispezione pre-accensione (Obbligatorio)

Full wiring check: No cross-connection, short circuit or loose terminal

DC supply test: 24V DC ±10% measured across pin3.1 &3.2

Isolation test: No continuity between Input/Output/Power with multimeter continuity mode

7.2 Indicazione dello stato del LED

PWR(Verde): Steady ON=Normal Supply; OFF=Power fault/reverse polarity

RUN(Verde): Blinking=Running normally; Solid/OFF=Module malfunction

7.3 Calibrazione (Optional for high precision requirement)

Zero Adjustment: Feed zero input signal, trim ZERO potentiometer for zero output

Span Adjustment: Feed full-scale input, trim SPAN potentiometer for full-scale output

Precisione: ≤0.1%FS, max temperature drift ≤±2%

  1. On-site Quick Troubleshooting

8.1 Power LED Dark

Causa: Reverse polarity, abnormal voltage, cablaggio allentato | Action: Correct polarity, misurare la tensione, retighten terminals

8.2 Zero Output Signal

Causa: Cablaggio errato, mismatched DIP setting, sovraccarico | Action: Ricablare, reset switches, check load impedance

8.3 Unstable Swinging Output

Causa: Improper shield grounding, high supply ripple, nearby EMI | Action: Single-point ground, install power filter, relocate away from interference source

8.4 Out-of-spec Accuracy

Causa: Thermal drift, zero/span shift, mismatched load | Action: Ricalibrare, migliorare la ventilazione, adjust load

  1. Periodic Maintenance

Every 6-month routine: Power off to clean terminal/housing, recheck screw torque & recalibrate accuracy

Forbidden operation: Hot plug/unplug, overvoltage/overtemperature running, unauthorized internal circuit disassembly

  1. Supporto tecnico & Alternative Part

Manufacturer Support: Phoenix Contact China

Sostituzione dell'aggiornamento: MACX MCR‑UI‑UI (2811284):12.5larghezza mm, consumo energetico inferiore, faster response speed

Prec:

Prossimo:

Lascia una risposta