PNOZ-X2.8P-777301 PILZ Safety Relay - Contattore,interruttore automatico,inverter solare,contatore elettrico,batterie solari

Wechat: +86-13184948252 Whatsapp: 0086-13811255435 E-mail: kent@bestcontactor.com

Di Contatto |

PNOZ-X2.8P-777301 PILZ Safety Relay - Contattore,interruttore automatico,inverter solare,contatore elettrico,batterie solari

elettrico/

PNOZ-X2.8P-777301 PILZ Safety Relay

PNOZ-X2.8P-777301-PILZ is the most widely used dual-channel safety relay from Pilz’s PNOZ X product line. Its core advantages cover wide 24V AC/DC operating voltage, 3NO+1NC contact configuration, high safety rating of SIL 3 / PL e, and ultra-fast response within ≤50ms. It is extensively deployed for various industrial safety monitoring applications. Thanks to hardwired design, ...

  • Dettagli del prodotto

PNOZ-X2.8P-777301-FUNGO is the most widely used dual-channel safety relay from Pilz’s PNOZ X product line. Its core advantages cover wide 24V AC/DC operating voltage, 3NO+1NC contact configuration, high safety rating of SIL 3 / PL e, and ultra-fast response within ≤50ms. It is extensively deployed for various industrial safety monitoring applications. Thanks to hardwired design, it delivers superior reliability over software-based solutions under high-vibration and severe EMI conditions, making it an optimal choice for industrial automation safety protection.

  1. Scomposizione del codice modello
Segmento di codiceDefinizioneDescrizione dettagliata
PNOZPrefisso della serie di prodottiIdentifier for Pilz core safety relay product range
XCodice della serieBasic standalone safety relay of PNOZ X series, operable without extension modules
2.8Functional code“2” stands for dual-channel monitoring; “8” denotes automatic / monitored start mode with 3 safety outputs plus 1 auxiliary output
PTipo di terminazioneScrew terminal version; Push-in indicates spring-cage pluggable terminals, unmarked for standard terminals
777301Numero dell'ordineUnique global part number for purchasing and inventory management
FUNGOBrand namePilz GmbH & Co. KG, Germania
  1. Specifiche tecniche principali
Categoria dei parametriSpecificaOsservazioni
General Data
Tipo di prodottoDual-channel safety relayConforme alla norma EN ISO 13849-1 (PL e) & IN 62061 (SIL 3)
Rated Supply24V CA/CC (±15%)Wide-range input compatible with standard industrial power supplies
Dimensione94×22.5×121mm (A×L×P)22.5mm standard width for compact cabinet layout
Montaggio35Guida DIN da mm (IN 60715)Installazione verticale, coppia di serraggio: 0.5~0.8Nm
Caratteristiche di ingresso
Input Circuits2 independent dual-channel inputs (S11-S12/S52, S21-S22)24A DC, 30mA input, compatible with PNP sensors
Input FunctionOptional cross-contact short-circuit detectionEnabled by short-circuiting S11-S12; disabled by short-circuiting S21-S22
Caratteristiche di uscita
Safety Outputs3 Normalmente aperto (NO) contacts with redundant dual-contact series designRedundant structure for guaranteed safe cut-off
Auxiliary Output1 Normalmente chiuso (NC) contattoSolo per indicazione dello stato, NOT permitted in safety circuits
Valutazione dei contattiAC1:240V/6A; DC1:24V/6AAgCuNi silver-copper-nickel contact material for arc oxidation resistance
AC15:230V/5A; DC13:24V/5A
Parametri di prestazione
Tempo di risposta≤50ms (input to output); reset time ≤100msFast safety cut-off for high-speed machinery
Consumo energeticoMax.100mALow-power design for energy saving
Temperatura ambienteOperazione: -10°C~+55°C; Magazzinaggio: -35°C~+70°CSuitable for harsh industrial ambient conditions
Protezione dall'ingressoIP20 (corpo principale), IP40 (terminal area)Must be installed inside control cabinet ≥IP54
CertificazioniCE, CCC, UL, RoHSGlobal market access certifications

III. Full Range Model List (Core PNOZ X2 Series)

ModelloOrdine n.Tensione di alimentazioneConfigurazione dell'uscitaStart ModeTipo di terminale
PNOZ X2.8P77730124V CA/CC3NA+1NCAutomatico / MonitoredVite
PNOZ X2.877730024V CA/CC3NA+1NCAutomatico / MonitoredStandard
PNOZ X2.8P PI77730224V CA/CC3NA+1NCAutomatico / MonitoredCollegare
PNOZ X2.7P77731124~240V AC/DC3NA+1NCAutomatico / MonitoredVite
PNOZ X2.777731024~240V AC/DC3NA+1NCAutomatico / MonitoredStandard
PNOZ X2.10P77732124A DC2NA+1NCRipristino manualeVite
PNOZ X2.11P77733124A DC3NA+1NCRipristino manualeVite
  1. Cross-Brand Equivalent Replacement Table
MarcaAlternative PartDifferenze chiaveAmbito di applicazione
SchneiderZelio SR2B121BDSingle-channel, 2NA+1NC, 24VDC onlyLow-risk applications with limited budget
Siemens3SK1111-1AB30Doppio canale,3NA+1NC,24V CA/CCFull drop-in replacement, SIL3 compliant
OmronG9SA-321-T075Doppio canale,3NA+1NC,24V CA/CCMatched for Japanese-built equipment, conveniente
ABBMSR125TPDoppio canale,3NA+1NC,24V CA/CCHeavy-duty machinery with superior anti-vibration performance
Pilz UpgradePNOZ X2.7P (777311)Wide voltage:24~240V AC/DCGlobal projects with varying supply voltages
  1. Ambiente applicativo & Casi di settore

Applicazioni consigliate

  1. Machinery Safety Monitoring: Emergency stop pushbuttons, safety door interlocks, safety light curtains, two-hand control stations
  2. Produzione automobilistica: Welding robots, coating production lines, lithium battery equipment interlock control
  3. Electronics Assembly: Macchine per il posizionamento SMT, AOI inspection equipment, laser cutter safety circuits
  4. Macchine per l'imballaggio: Linee di confezionamento ad alta velocità, palletizing robots, over-temperature protection for heat-sealing devices
  5. Logistics Automation: Stacker cranes, AGVs, conveyor safety door & E-stop systems

Non-Recommended Applications

Safety systems requiring complex logic operations (PNOZmulti modular safety controller recommended)

Extreme high-vibration environments (>10G): extra vibration dampening required

Unprotected outdoor mounting (only IP20 body protection)

Casi applicativi tipici

Case1: Lithium Battery Aging Room Safety Control for Automotive Industry

Funzioni: Access door interlock, emergency cut-off on over-temperature, fire protection linkage

Configurazione: PNOZ X2.8P(777301)+safety door switch+temperature sensor+E-stop button

Risultato: PL e safety level achieved to prevent thermal runaway of lithium cells

Case2: Safety Circuit Retrofit for Laser Cutting Machine

Original Issue: Distributed safety PLC I/O triggered false shutdown twice in three years due to EMI interference

Soluzione: Replace with hardwired safety circuit using PNOZ X2.8P

Risultato: Zero breakdown over 5 anni, response optimized ≤50ms, costi di manutenzione ridotti 60%

  1. Suggerimenti per la selezione & Regole di riferimento rapido

Quick Selection Formula

24V AC/DC X2.8, dual-channel with three NO & one NC<fratello>

Terminale a vite 777301, automatic start with top safety grade<fratello>

E-stop, cortina di luce & porta di sicurezza, certified SIL3 & PL e<fratello>

DIN rail mounting saves cabinet space, fits all industrial sites

Regole di riferimento rapido

  1. Model Memorization: PNOZ X2.8P = Dual-channel + Mode8 + P=screw terminals
  2. Codice ordine:777301 = standard baseline part of Pilz X2 family
  3. Specifiche principali:24V CA/CC,3NA+1NC,≤50ms response,SIL3/PL e
  4. Terminal Wiring Rules:

Short S11-S12: Activate contact short-circuit detection

Short S21-S22: Deactivate contact short-circuit detection

Short S12-S34: Enable automatic start mode

Short S52-S11: Enable automatic reset function

VII. Installazione & Linee guida per la manutenzione

Specifiche di installazione

  1. Mount vertically inside control cabinet with terminals facing upward for natural convection cooling
  2. Maintain ≥50mm clearance from heat-generating components, ≥30mm from cabinet inner walls
  3. Separate wiring of safety circuits and power circuits; route crossing wires at 90° to reduce EMI coupling
  4. Install 10A fuse in series ahead of output contacts for contact protection

Common Troubleshooting Guide

Fenomeno di guastoRoot CauseRemedial Action
Power indicator off1. No power supply or reversed polarity1. Verify A1/A2 wiring
2. Input voltage out of tolerance2. Confirm stable 24V AC/DC supply
Safety outputs fail to close1. Open input circuit1. Check continuity of S11-S12/S21-S22
2. Incorrect start circuit configuration2. Confirm jumper status of S12-S34
Contact ablation/burning1. Overloaded output rating1. Upgrade to higher-rated relay
2. Missing snubber for inductive loads2. Fit freewheeling diode(DC) or varistor(AC) in parallel
Unexpected false tripping1. Electromagnetic interference on input lines1. Apply shielded cable with proper grounding
2. Misconfigured short-circuit detection2. Adjust S11-S12/S21-S22 jumper setup

VIII. Air Shipment Compliance & Dettagli della certificazione

Numero ONU: Nessuna batteria al litio integrata, classified as non-dangerous goods

Categoria Trasporti: Carico generale, acceptable for air, sea and land freight

CE Compliance: Conforme alla norma EN 60947-5-1/-2 and EN ISO 13849-1

HS Code: 85364900 (Other electrical relays)

Prec:

Prossimo:

Lascia una risposta

Lasciate un messaggio