Schneider Easy9 series 4‑pole 63A C‑curve interruttore automatico miniaturizzato, used for overload and short‑circuit protection in three‑phase four‑wire distribution systems. DIN‑rail mountable, suitable for final distribution in residential, commercial and light industrial applications.

1 Model Explanation

PartMeaning
EA9ANEasy9 series standard MCB
44 poli (3 phases + N), all poles with protection function
CC tripping curve (5–10In instantaneous trip), suitable for lighting and resistive/slightly inductive mixed loads
63Rated current 63A (at 30°C ambient)

2 Parametri tecnici chiave

ParametroValoreDescription
Rated operational voltage230/400V eSuitable for single‑/three‑phase systems
Tensione di isolamento nominale400V e-
Rated frequency50/60HzUniversal frequency
Potere di interruzione nominale6IL (400V)Standard breaking capacity for general distribution
Tripping typeThermal‑magneticThermal overload protection + magnetic short‑circuit protection
Curva di interventoC‑curveInstantaneous trip range: 5–10In, moderate inrush current withstand
Number of poles4P4 protected poles, neutral on the left
Mounting35mm DIN railStandard electrical cabinet mounting
Electrical endurance10,000 operazioniRated operating cycles
Mechanical endurance20,000 operazioniMechanical operating cycles
DimensioniApprox. 85mm×78.5mm×18mm (4‑pole width)Standard 4‑pole MCB size
StandardsGB16917/IEC60898National and international standards

3 Funzioni principali & Features

  1. Protezione da sovraccarico: Thermal trip unit acts with current‑time accumulation to prevent overheating and burnout.
  2. Short‑circuit protection: Magnetic trip unit operates instantaneously (<0.1s) to clear short‑circuit current and protect equipment and wiring.
  3. Isolation function: Complies with EN/IEC 60947‑2, can be used as an isolating device.
  4. Quick make: Internal mechanism ensures fast circuit closing.
  5. Operation indication: Clear ON/OFF status indication for easy maintenance.
  6. Safety design: Anti‑misoperation structure, high insulation performance, safe and reliable.

4 Applicazioni tipiche

Residential distribution: Main incoming breaker for three‑phase four‑wire homes, protecting the entire electrical system.

Commercial buildings: Floor or zone main breaker in offices, centri commerciali, Hotel, ecc.

Light industry: Branch circuit protection for workshops and production lines, suitable for mixed motor, lighting and socket loads.

Final distribution: Dedicated protection for three‑phase equipment (condizionatori d'aria, pumps, small machine tools).

5 Cross‑Brand Replacement Reference

MarcaReplacement ModelNote
ABBS204‑C63Same 4P C63A, 6kA breaking capacity
Siemens5SY6463‑7CC4P C63A, standard breaking capacity
CINTNXB‑63 4P C63Domestic alternative, cost‑effective
DeliziosoCDM30s‑63 4P C63Similar performance, compatible with domestic panels
Schneider upgradeA9F94463 (Acti9 series)Breaking capacity up to 15kA, improved performance

6 Installazione & Note sulla selezione

  1. Installation precautions

Must be mounted on 35mm standard DIN rail, installation depth ≥78.5mm

Terminal suitable for copper conductors: 1.5–35mm²

Neutral must be connected to the designated left terminal – do not reverse.

  1. Selection recommendations

Total three‑phase load current ≤63A, suitable for C‑curve loads (not heavy motor starting).

For distribution systems with short‑circuit current >6IL, upgrade to higher breaking capacity models (per esempio., Acti9 series).

Derate at ambient temperature >30°C: current reduced by 1% per °C rise.

Schneider EA9AN4C63 vs Acti9 A9F94463 Full Comparison & Upgrade Recommendation

At a glance: A9F94463 (iC60L series) is superior to EA9AN4C63 in breaking capacity, compactness, accessory expandability, and electrical/mechanical endurance, suitable for higher short‑circuit risk and higher reliability/expandability requirements.

EA9AN4C63 is more economical and meets basic protection for standard residential and light commercial use.

1 Core Parameter Comparison

ParametroEA9AN4C63 (Easy9)A9F94463 (Acti9 iC60L)Key Difference
Series positioningEconomic standardHigh‑performance standardA9 higher‑end, richer functions
Poles/Current/Curve4P / 63UN / C‑curve4P / 63UN / C‑curveBasic specs identical
Potere di interruzione nominale6IL (400V)15IL (400V)A9 ×2.5 higher, stronger short‑circuit withstand
Tensione di isolamento nominale400V e400V eSame
Rated operational voltage230/400V e230/400V eSame
Tripping typeThermal‑magneticThermal‑magneticSame
Mounting35mm DIN rail35mm DIN railSame
Dimensioni85mm×78.5mm×18mm (4P)85mm×44.5mm×18mm (4P)A9 depth –43%, saves panel space
Wiring capacity1.5–35mm² (copper)1.5–35mm² (copper), dual tunnel terminalsA9 more secure, same conductor range
Electrical endurance10,00015,000A9 +50%
Mechanical endurance20,00025,000A9 +25%
Protection degreeIP20IP20 (terminal IP20B)A9 better terminal protection
Accessory compatibilityBasic accessories (aux./shunt)Full Acti9 range (aux., shunt, UVP, remote, ecc.)A9 more expandable, supports Ti24
StandardsGB16917/IEC60898GB16917/IEC60898/IEC60947‑2A9 covers more standards
Price rangeApprox. ¥150–200Approx. ¥350–500A9 ~2–2.5× EA9 price

2 Detailed Performance Differences

2.1 Capacità di interruzione: Core Safety Gap

EA9AN4C63: 6IL, suitable for general systems with short‑circuit current ≤6kA.

A9F94463: 15kA high breaking capacity, reliably clears higher short‑circuit currents, reduces arc risk.

Suitable for:

Industrial plants, large commercial buildings

Distribution circuits near transformers

Systems where short‑circuit current may exceed 6kA

2.2 Compact Design: Better Space Utilization

A9F94463 depth only 44.5mm, greatly reduced from EA9AN4C63 78.5mm.

Benefits:

Fits slimmer distribution boards/cabinets

Saves installation space, eases maintenance

Ideal for retrofit projects with limited space

2.3 Endurance & Reliability: Longer‑Term Stability

Electrical endurance from 10k → 15k operations; mechanical 20k → 25k.

A9 series uses higher‑grade materials and precision manufacturing for better long‑term stability.

Better vibration and impact resistance for harsh environments.

2.4 Accessory Expandability: Flexible Function Upgrades

EA9AN: Supports only basic auxiliary contacts and shunt trips.

A9F94463: Supports full Acti9 accessory range:

Multi‑function auxiliary / alarm contacts

Remote‑control shunt trips

Over/undervoltage protection modules

Auto‑reclose accessories

Ti24 interface for PLC/BMS integration

3 Upgrade Decision Guide

Recommended to upgrade to A9F94463 if:

  1. Calculated short‑circuit current >6IL
  2. Critical facilities: industriale, large commercial, hospital, data center
  3. Future expansion needed (remote control, voltage monitoring, ecc.)
  4. Limited panel space requires compact solution
  5. Higher reliability and longer service life required to reduce maintenance cost

Recommended to keep EA9AN4C63 if:

  1. Standard residential / small shop loads, short‑circuit ≤6kA
  2. Budget‑sensitive, cost priority
  3. Basic protection only, no complex accessories
  4. Already installed EA9 panel with matching system parameters

4 Replacement Notes

  1. Direct interchangeability: Both 4P C63A, DIN‑rail mount – direct replacement.
  2. Wiring check: A9F94463 neutral position matches EA9AN (left) – no need to reorder wiring.
  3. Derating: Both derate at >30°C (–1% per °C).
  4. Accessory compatibility: Existing EA9 accessories must be replaced with Acti9‑specific versions.

Prec:

Lascia una risposta

Lasciate un messaggio