Ventola con filtro Schneider NSYCVF165M230PF

Model Code Definition Breakdown of NSYCVF165M230PF Code Segment Meaning Description NSY Product series prefix General mark for Schneider ClimaSys cabinet cooling products CV Sub-series ClimaSys CV series standard cabinet filter fan F Product type Fan 165 Air flow rate Rated airflow 165m鲁/h at 50Hz, 193m鲁/h at 60Hz M Mounting type Side mounting on cabinet 230 ...

  • Dettagli del prodotto

Definizione del codice modello

Breakdown of NSYCVF165M230PF

Segmento di codiceSensoDescrizione
NSYPrefisso della serie di prodottiGeneral mark for Schneider ClimaSys cabinet cooling products
CVSottoserieClimaSys CV series standard cabinet filter fan
FTipo di prodottoFan
165Air flow rateRated airflow 165m鲁/h at 50Hz, 193m鲁/h at 60Hz
MTipo di montaggioSide mounting on cabinet
230Tensione nominale230V e
PProtection configurationEquipped with pre-filter
FAir outlet configurationFitted with front grille
  1. Parametri delle specifiche principali
CategoriaIndice tecnicoOsservazioni
Parametri di base
Tipo di prodottoCabinet Filter FanClimaSys CV series, Protezione IP54
Air Flow165m³/h (50Hz) / 193m³/h (60Hz)Measured with standard G2 filter
Intervallo di tensione175~253V ACCompatible with most 230V power grids worldwide
Tensione nominale230V 50/60HzDual frequency compatibility
Parametri Elettrici
Energia16.3W (50Hz) / 14.3W (60Hz)Alta efficienza energetica
Attuale0.12UN (50Hz) / 0.94UN (60Hz)Low power consumption design
ConnessioneFaston terminal + power cableInstallazione semplice
Parametri fisici
External Dimension268×248×104mmHeight×Width×Depth
Cutout Size223×223mmStandard cabinet mounting hole
MaterialeAir outlet grille: ASA+PC thermoplasticAnti-aging, grey RAL 7035
Peso1.14kgStable installation, low resonance
Parametri di prestazione
Classe di protezioneIP54Dustproof and splashproof, suitable for outdoor cabinets
Bearing TypeCuscinetto a sfereLunga durata, basso rumore
Livello di rumore50~51dBQuiet operation, applicable near office areas
Max Static Pressure50Pa (0m³/h)Resists certain air resistance
Parametri Ambientali
Temperatura operativa-20℃~60℃Wide temperature range for harsh environments
Temperatura di conservazione-40℃~70℃Reliable transportation and storage
CertificazionePORTATA, RoHSCompliant with environmental standards
  1. Elenco completo dei modelli della serie
ModelloAir Flow(m³/h)VoltaggioConfigurazioneCutout Size(mm)External Size(mm)
NSYCVF38M230PF39230V eGrille + Filtro117×117137×137×85
NSYCVF54M230PF54230V eGrille + Filtro148×148170×170×92
NSYCVF85M230PF85230V eGrille + Filtro170×170190×190×95
NSYCVF165M115PF165/193115V eGrille + Filtro223×223268×248×104
NSYCVF165M230PF165/193230V eGrille + Filtro223×223268×248×104
NSYCVF165M24DPF165/19324A DCGrille + Filtro223×223268×248×104
NSYCVF300M230PF300/350230V eGrille + Filtro262×262300×300×110
NSYCVF550M230PF550/650230V eGrille + Filtro336×336380×380×120
NSYCVF850M230PF838/980230V eGrille + Filtro400×400450×450×130
NSYCVF850M400PF838/980400V eGrille + Filtro400×400450×450×130
  1. Cross-brand Replacement Comparison
MarcaModelloAir Flow(m³/h)VoltaggioClasse di protezioneCutout Size(mm)Vantaggi della sostituzione
Rittal323920074/87230V eIP54148×148Tool-free quick installation
Rittal3241700160/190230V eIP54223×223High-efficiency energy saving series
StegoF.K 66230165/193230V eIP54223×223Integrated temperature control, intelligent start-stop
Pfannenberg1041230160/190230V eIP54223×223Long filter service life, low maintenance frequency
RSPRO130-853165/193115V eIP54223×223Conveniente, sufficient stock
  1. Risoluzione dei problemi comuni & Manutenzione
Fenomeno di guastoPossibili causeInspection StepsMaintenance Solution
Fan not running1. Power disconnected1. Test power voltage1. Reconnect power supply
2. Motor burnout2. Check motor winding resistance2. Replace identical motor
3. Stuck bearing3. Manually rotate fan blade3. Clean and lubricate bearing
4. Control circuit failure4. Inspect loose Faston connector4. Reconnect or replace connector
Reduced airflow1. Clogged filter1. Check filter blockage1. Clean or replace G2 filter
2. Dust accumulated on blades2. Inspect blade cleanliness2. Clean blades with soft brush
3. Sottotensione3. Measure operating voltage3. Adjust voltage to rated value
4. Reverse rotation4. Verify mounting direction4. Reinstall fan outward air discharge
Abnormal noise1. Worn bearing1. Locate noise source1. Replace bearing or whole fan
2. Unbalanced fan blade2. Check blade deformation and attachments2. Correct balance and clear debris
3. Loose mounting3. Tighten mounting screws3. Fasten all screws
4. Vibration resonance4. Observe cabinet vibration4. Add shock pad or adjust position
Protezione da sovracorrente1. Motor short circuit1. Test insulation resistance1. Replace motor
2. Excessive bearing friction2. Check bearing flexibility2. Lubricate or replace bearing
3. Sovratensione3. Measure operating voltage3. Restore normal voltage
  1. Ambiente applicativo & Casi di settore

Scenari applicabili

  1. Automazione industriale: Cooling for PLC, inverter and servo drive cabinets
  2. Sistema di alimentazione: Heat dissipation for outdoor ring main units, box substations and charging pile control boxes
  3. Telecommunication: Ventilation for base station cabinets, optical distribution boxes and data center server cabinets
  4. Transito ferroviario: Temperature control for signal boxes and converter cabinets
  5. New Energy: Cooling for photovoltaic inverters and energy storage control cabinets

Scenari non consigliati

  1. Corrosive atmosphere such as chemical and marine environment (anti-corrosion model required)
  2. Heavy dust sites like mines and cement plants (extra pre-filter needed)
  3. Submerged or long-term rain exposure (IP54 only splash-proof)
  4. Fully sealed space without air inlet circulation

Casi tipici

Automobile Factory: Installed on welding robot cabinets, failure rate reduced by 70% against high temperature

Power Grid Company: Eliminated switch misoperation, equipment service life extended 3 volte

Centro dati: Hierarchical cooling with air conditioner, energy consumption cut by 20%

  1. Suggerimenti per la selezione & Avoidance Guide

Quick Calculation Rule

  1. Airflow demand = Cabinet volume × (8~10) m³/h, suitable for 16~20m³ cabinet
  2. Voltage selection: 230V for general industry, 115V for North America, 24V for DC system
  3. Mounting mark: M=side, MF=top, FB=bottom

Operation Warnings

  1. Inspect and replace G2 filter every 3 months to avoid airflow drop and motor overload
  2. Keep air outlet outward and match air inlet for effective ventilation
  3. Adopt cabinet air conditioner when external temperature is 5℃ higher than internal temperature
  4. Restrict voltage fluctuation within ±10% to guarantee service life
  5. Confirm UL, CE and other certifications for export use
  6. Order Information

Modello: NSYCVF165M230PF

Ordine n.: NSYCVF165M230PF (Global unified)

Package Contents: 1 axial fan motor, 1 cutting template, 1 pre-filter, 1 air outlet grille, 1 power cable, 2 protective grilles

Delivery Lead Time: 3-5 working days for standard stock items