SMC Filter Regulator AW30-03E1-W-B

SMC AW series modular filter regulator, 3/8 inch port size, 5μm filtration precision, equipped with reverse flow function and white built-in pressure gauge. It is used for pre-treatment of compressed air in pneumatic systems, supplying clean and stable compressed air to solenoid valves, cylinders and other pneumatic components. Model Segment Definition Model Segment Meaning Description ...

  • Dettagli del prodotto

SMC AW series modular filter regulator, 3/8 inch port size, 5μm filtration precision, equipped with reverse flow function and white built-in pressure gauge. It is used for pre-treatment of compressed air in pneumatic systems, supplying clean and stable compressed air to solenoid valves, cylinders and other pneumatic components.

  1. Definizione del segmento del modello
Segmento modelloSensoDescrizione
AWSerie di prodottiIdentification of SMC modular filter regulator series
30Dimensioni del telaioMisurare 30, flow rate approx. 1400 l/min (ANR)
3Port Specification3/8 pollice (Rc thread)
E1Funzione specialeE = With reverse flow function; 1 = Standard type
WPressure Gauge TypeWhite built-in pressure gauge (with limit indicator)
BDrainage ModeManual drain (B = Standard type)
SMCLogo del marchioSMC Corporation, Giappone
  1. Core Specification Parameter Table
Categoria dei parametriTechnical IndexOsservazioni
Parametri di base
Working FluidCompressed AirExcluding corrosive gas and chemically active gas
Massimo. Operating Pressure1.0 MPa (10 sbarra)Exceeding may damage internal components
Pressure Setting Range0.02~0.8 MPaStandard pressure regulation range
Filtration Precision5µmEffectively filters solid particles and oil mist
Dimensione della portaTc3/8 (3/8 inch taper pipe thread)Inlet and outlet identical
Flow Characteristic1400 l/min (ANR)At pressure drop of 0.02 MPa
Temperatura ambiente-5℃ ~ +60 ℃Under non-freezing condition
Fluid Temperature-5℃ ~ +60 ℃
Pesoca. 0.36 kgIncluding pressure gauge
Structural Characteristics
Pressure Regulation MethodKnob type (with locking function)Prevenire operazioni errate
Drainage ModeManual drainRotate bottom knob clockwise for draining
Pressure GaugeWhite built-in, 0~1.0 MPaWith limit indicator for easy pressure setting management
Bowl MaterialPolycarbonate (computer)Transparent with metal protective cover
Filter ElementPolyester FiberReplaceable, service life approx. 1000 ore
Reverse Flow FunctionConfigurazione standardAllows reverse airflow for special circuit application
Caratteristiche di installazione
Tipo di montaggioModular mounting / Independent mountingCan be combined with other SMC air preparation components
Mounting DirectionInstallazione verticale (bowl facing downward)Ensure good drainage performance
Direzione del flussoLeft inlet, Right outletStandard flow direction
  1. Elenco degli accessori & Linee guida per l'installazione

3.1 Standard Package Contents

AW30-03E1-W-B Filter Regulator main unit

White built-in pressure gauge (preinstallato)

Metal bowl protective cover (preinstallato)

Filter element (preinstallato)

Mounting bracket (for modular assembly)

Product manual (including maintenance instructions)

3.2 Accessori opzionali

Parte n.NomeFunzione
AW30-03-DFilter Element (Pezzo di ricambio)5μm filtration precision, periodic replacement
KQ2H03-00Push-in FittingSimplify tube connection
AME30-03LubricatorCombine with filter to form FRL unit
AC30-03Air FilterFront coarse filtration to extend main filter service life
AW30-X2622SUS316 Stainless Steel VersionSuitable for corrosive environments

3.3 Punti chiave dell'installazione

Mounting Direction: Must be installed vertically with the bowl facing downward to ensure smooth discharge of condensed water.

Metodo di connessione: Rc3/8 threaded connection; sealing tape or sealant is recommended, tightening torque 15~20 Nm.

Modular Combination: Can be assembled with SMC series lubricators and regulators via modular clips to save installation space.

Maintenance Clearance: Reserve ≥50mm space at the bottom for manual draining and filter replacement.

Air Pre-filtration: It is recommended to install a main line filter at the upstream with filtration precision ≤40μm to protect this component.

  1. Funzioni & Scenari applicativi

Funzioni principali

  1. Gas-Liquid Separation: Effectively separate moisture and impurities from compressed air via centrifugal force and filter element.
  2. Pressure Regulation: Precisely adjust output pressure to keep pneumatic system stable.
  3. Pressure Indication: White built-in pressure gauge with limit indicator for intuitive pressure monitoring and safety range setting.
  4. Reverse Flow Protection: Built-in reverse flow valve allows reverse airflow and prevents circuit pressure impact.
  5. Manual Draining: Bottom knob draining design, funzionamento facile, suitable for low-humidity environments.

Scenari applicativi tipici

Campo di applicazioneAttrezzatura applicabileFunzione fondamentale
Automated Production LineAssembly line, Conveyor systemSupply clean and stable air to solenoid valves and cylinders
Machine Tool IndustryMachining center, CNC latheProtect pneumatic fixtures and tool changing systems
Packaging EquipmentPackaging machine, PalletizerStabilize speed and force of pneumatic actuators
Produzione elettronicaApparecchiature per semiconduttori, Macchina per il posizionamento SMTPrevent fine particles from contaminating precision components
Cibo & BevandaFilling equipment, Packaging lineMeet food-grade pneumatic system requirements
Produzione automobilisticaWelding robot, Coating lineProtect pneumatic tools and precision inspection equipment
  1. Cross-Brand Alternative Comparison Table
MarcaModelloParametri chiaveCompatibilitàFascia di prezzo
SMC (Originale)AW30-03E1-W-B3/8″, 5µm, 0.02~0.8MPa, Reverse flow / White gauge100%600–800 CNY
FESTALFR-3/8-D-MINI3/8″, 5µm, 0.05~0.8MPa, Manual drainAlto500–700 CNY
SchneiderV50A313A-033/8″, 5µm, 0.05~0.8MPa, With pressure gaugeMedio400–600 CNY
ARTICOGFR300-033/8″, 5µm, 0.05~0.8MPa, Manual drainMedio200–300 CNY
NORGRENB72G-3GK-AD3-RMN3/8″, 5µm, 0.07~0,7MPa, With pressure gaugeAlto700–900 CNY
  1. Linee guida per la selezione & Soluzioni alternative

Selection Mnemonic

Port Matching → Flow Demand → Filtration Precision → Pressure Range → Drainage Mode → Special Function

Guida alla decisione di selezione

  1. Dimensione della porta: Select 1/4″(02), 3/8″(03) or 1/2″(04) according to pipeline; this model is 3/8″.
  2. Flow Demand: Misurare 30 for medium flow (1400 l/min); choose Size 20 for low flow, Misurare 40/60 for high flow.
  3. Filtration Precision: Standard 5μm for most industrial scenarios; precision equipment optional 2μm (suffix with “G”).
  4. Intervallo di pressione: 0.02~0.8MPa for general use; select 1.6MPa version for high-pressure systems.
  5. Drainage Mode: Manual drain (B) for low humidity; automatic drain (suffix withDP”) for high humidity.
  6. Funzione speciale: Choose type “E” for reverse flow; “BGfor oil mist separation; “X2622for stainless steel version.

Alternative consigliate

  1. Budget Limited: Adopt AIRTAC GFR300-03 or domestic alternatives to meet basic functions with cost performance.
  2. Integrazione del sistema: FESTO LFR series for seamless compatibility with FESTO pneumatic components; NORGREN B72G series for high-end applications.
  3. Function Upgrade: Upgrade to AW30-03BD-M5 (scarico automatico + pressure gauge port) for unattended operation.
  4. Ambiente duro: Select AW30-03E1-W-B-X2622 (SUS316 material) for corrosive conditions.
  5. Air Freight Compliance & Certificazione

Certificazione CE: Conforme alla norma EN ISO 4414, ISO 8573-1.

Air Freight Assessment: No built-in lithium battery / supercapacitor; classified as ordinary industrial pneumatic part, no special air freight restrictions.

Packaging Requirement: Anti-static packaging; transport temperature -40℃~+85℃, avoid heavy impact.

Material Compliance: Polycarbonate bowl complies with RoHS standard, applicable to food, electronics and other sensitive industries.

  1. Troubleshooting Quick Reference
Fenomeno di guastoPossibile causaSoluzione
Unstable Output PressureClogged filter element, fatigue pressure spring, air supply fluctuationReplace filter element, check air source, recalibrate pressure
Pressure Not AdjustableRegulating knob locked, diaphragm damaged, valve core stuckUnlock knob, replace diaphragm, clean valve core
No Pressure Gauge ReadingBroken pressure gauge, blocked pipeline, no air supplyReplace pressure gauge, clear pipeline, check air source
Difficult DrainingTilted bowl, blocked drain outlet, excessive condensed waterAdjust mounting angle, clean drain port, increase draining frequency
Air LeakageAging seals, loose thread connection, damaged diaphragmReplace seals, fasten thread, replace diaphragm
Reverse Flow FailureDamaged reverse valve, foreign matter jammingDisassemble for cleaning or replace reverse flow assembly
  1. AW30 Series Full Model & Order Number List
Ordine n.ModelloPort SpecFiltration PrecisionFunzione specialeDrainage ModePressure Gauge Type
AW30-03E1-W-BAW30-03E1-W-BTc3/85µmReverse FlowManualeWhite Built-in
AW30-03-BAW30-03-BTc3/85µmNo Reverse FlowManualeStandard Built-in
AW30-03E-BAW30-03E-BTc3/85µmReverse FlowManualeStandard Built-in
AW30-03BG-BAW30-03BG-BTc3/85µmReverse Flow + Oil Mist SeparationManualeStandard Built-in
AW30-03BD-BAW30-03BD-BTc3/85µmNo Reverse FlowAutomaticoStandard Built-in
AW30-03ED-BAW30-03ED-BTc3/85µmReverse FlowAutomaticoStandard Built-in
AW30-03E1-W-DAW30-03E1-W-DTc3/85µmReverse FlowAutomaticoWhite Built-in
AW30-03G-BAW30-03G-BTc3/82µmNo Reverse FlowManualeStandard Built-in
AW30-03EG-BAW30-03EG-BTc3/82µmReverse FlowManualeStandard Built-in
AW30-03-X2622AW30-03-X2622Tc3/85µmNo Reverse FlowManualeStandard Built-in
  1. Ciclo di manutenzione & Raccomandazioni per la manutenzione
  2. Filter Element Replacement: Replace every 1000 hours or 3 months under normal working conditions; shorten to 1 month in harsh environments.
  3. Bowl Cleaning: Inspect monthly, remove internal dirt and keep transparent visibility.
  4. Seal Inspection: Check O-rings, diaphragms and other seals every 6 mesi; replace in time if aging.
  5. Pressure Calibration: Calibrate output pressure quarterly to meet system requirements.
  6. Draining Operation: Perform manual draining daily after work to prevent condensed water accumulation affecting filtering performance.