SMC SY3220-5G-C4 5/2-way Single-coil Pilot-operated Solenoid Valve Product Positioning SMC SY3000 series miniature 5/2-way single-coil pilot-operated solenoid valve. Designed specifically for high-frequency switching, suitable for small cylinder control. Widely applied in pneumatic automation, apparecchiature elettroniche, macchine per l'imballaggio e altre industrie. Definizione del codice modello (SY3220-5G-C4) Segment Code Description Optional Configuration SY SY SMC SY series pilot-operated ...

  • Dettagli del prodotto

SMC SY3220-5G-C4 5/2-way Single-coil Pilot-operated Solenoid Valve

  1. Posizionamento del prodotto

SMC SY3000 series miniature 5/2-way single-coil pilot-operated solenoid valve.

Designed specifically for high-frequency switching, suitable for small cylinder control.

Widely applied in pneumatic automation, apparecchiature elettroniche, macchine per l'imballaggio e altre industrie.

  1. Definizione del codice modello (SY3220-5G-C4)
SegmentoCodiceDescrizioneOptional Configuration
SYSYSMC SY series pilot-operated 5-way solenoid valveFisso
33Size code: 3000 series miniature body (width 10mm)3=Mini, 5=Medium, 7=Large, 9=Extra Large
22Tipo di funzione: 5/2-way2=5/2-way, 3=5/3-way
2020Struttura: Single-coil + manifold base mounting20=Single-coil, 40=Dual-coil
55Tensione della bobina: DC24V4=AC110V, 5=DC24V, 6=AC220V
GGWiring type: Direct outlet type (lead type, cable length 300mm)G=Direct outlet, LZ=Socket with indicator, LD=Socket with indicator + diode
C4C4Port size: φ4mm push-in fittingC4=φ4mm, C6=φ6mm, M5=M5 thread
  1. Main Technical Specifications
CategoriaParametroDettagli
Basic CharacteristicsValve Type5/2-way, Single-coil, Internal pilot, Elastic seal
Working MediumCompressed air (Lubrication optional; ISO VG32 lubricant recommended)
Tipo di montaggioManifold base mounting
Pressure RatingsOperating Pressure0.15~0.7 MPa
Proof Pressure1.0 MPa
Guaranteed Withstand Pressure1.5 MPa
Electrical RatingsTensione nominaleDC24V
Fluttuazione della tensione±10%
Consumo energeticoStandard: 2.5W; Energy-saving: 0.1W (with power-saving circuit)
Classe di protezioneIP40
Flow CharacteristicsEffective Cross-sectional Area1.1 mm²
Max Flow Rate196 NL/min @ 0.5MPa
Environmental RatingsAmbiente / Temperatura media-5℃~+50℃ (Non-freezing)
Umidità35%~85%RH
Parametri fisiciValve Body Width10mm (SY3000 series standard width)
Pesoca. 60G (including coil)
Piping MethodFront piping (push-in fitting)
  1. Standard Accessories List
Nome dell'accessorioSpecificaQtàOsservazioni
Solenoid Valve Main BodySY3220-5G-C41 pcIncludes coil, valve body, pilot valve
Outlet Cable300mm, 2-core1 pcStandard for G-type direct outlet
Mounting GasketFor SY3000 series1 pcManifold sealing
Mounting ScrewsM3×8mm2 pzFix valve to manifold
Manuale di istruzioniElettronico / Paper Version1 copyIncluding installation, manutenzione & Risoluzione dei problemi
  1. SY3220 Series Full Model List (Common Types)
    ModelloVoltaggioTipo di cablaggioDimensione della portaCaratteristiche
    SY3220-5G-C4DC24VDirect outletφ4mmTipo standard, high-frequency switching
    SY3220-5G-C6DC24VDirect outletφ6mmHigh flow type
    SY3220-5LZ-C4DC24VSocket with indicatorφ4mmVisible status, easy diagnosis
    SY3220-5LD-C4DC24VSocket with indicator + diodeφ4mmProtezione da inversione di polarità, protezione del circuito
    SY3220-4G-C4AC110VDirect outletφ4mmCompatible with AC110V control system
    SY3220-6G-C4AC220VDirect outletφ4mmCompatible with AC220V control system
    SY3220-5G-M5DC24VDirect outletM5 threadThread connection type
    SY3220-5GUE-C4DC24VDirect outlet with indicator + protezione contro le sovratensioniφ4mmAdvanced protection type

    Compatible Manifold Models

Manifold ModelNumber of StationsDimensione della portaCaratteristiche
SS5Y3-01-011-stationC4/C6/M51-station manifold
SS5Y3-02-022-stationC4/C6/M52-station manifold
SS5Y3-05-055-stationC4/C6/M55-station manifold
SS5Y3-10-1010-stationC4/C6/M510-station manifold
SS5Y3-20-2020-stationC4/C6/M520-station manifold
SS5Y3-05-05D5-stationC4/C6/M5With DIN rail mounting
  1. Concorrente & Cross-Brand Replacement Chart
MarcaModelloSpecification MatchingDifferenza fondamentaleIntercambiabilità
SMCSY3220-5G-C4100%Original genuine, qualità affidabile, prezzo più alto
Airtac4V210-0690%30% prezzo più basso, slightly lower flowSame mounting holes, direct interchangeable
MindmanMVSC-220-4E190%Similar response speed, prezzo moderatoDimensioni di montaggio compatibili
FestoVUVS-L20-M52-AD-G14-F885%Prezzo più alto, IP65 protectionRequires adapter plate
insufficienza renale cronica4F210-0885%Japanese quality, prezzo moderatoSame mounting holes
  1. Linee guida per la selezione & Regole di sostituzione

Suggerimenti per la selezione

Three key factors for SY3220 selection: voltaggio, wiring and port size;

5 stands for 24V, G for direct wire outlet;

C4 for Φ4 tube, C6 for Φ6 tube;

20 for single-coil, 40 for dual-coil match;

10mm miniature body, manifold mounting saves space.

Selection Decision Tree

  1. Tensione di controllo: Scegliere 5 for DC24V, 4 for AC110V, 6 for AC220V
  2. Tipo di cablaggio: Fixed installation → G (direct outlet); Frequent replacement → LZ/LD (socket type)
  3. Dimensione della porta: Low flow → C4 (Φ4mm); High flow → C6 (Φ6mm)
  4. Modalità di controllo: Single-acting → 20 single-coil; Double-acting → 40 dual-coil
  5. Montaggio: Manifold mounting → Standard type; Independent mounting → Model with F1 bracket

Raccomandazioni per la sostituzione

Budget limited: Choose Airtac 4V210-06, 30% cost down, sufficient performance for most working conditions

Manutenzione frequente: Select LZ/LD socket type for fast coil replacement and less downtime

Higher flow required: Upgrade to SY5220 series (medium body, effective area 2.8mm²)

Ambiente duro: Choose UE suffix model (con indicatore + protezione contro le sovratensioni) for higher reliability

  1. Typical Application Fields
  2. Electronic Equipment: Small cylinder drive, automatic assembly line, PCB conveying & posizionamento
  3. Macchine per l'imballaggio: Label attaching, controllo della tensione del film, packaging sealing cylinder
  4. Attrezzature mediche: Pneumatic control of analytical instruments, sample conveying mechanism
  5. Automation Production Line: Jig & fixture positioning, small manipulator joint control
  6. Food Processing: Small pneumatic actuator, sorting mechanism control
  7. Key Operation & Punti di manutenzione
  8. Before Installation: Ensure medium cleanliness (5μm filter recommended) to prevent seal damage by impurities
  9. Direzione di installazione: Follow the flow arrow on valve body; reverse installation is prohibited
  10. Manifold Mounting: Use sealing gasket, tighten screws evenly (torque 0.5~0.7N·m)
  11. Ciclo di manutenzione: Inspect seals every 6 mesi; replace O-rings annually
  12. Risoluzione dei problemi: No action → Check in sequence: Voltage → Air pressure → Coil → Pilot valve

SMC SY Series Solenoid Valve Complete Model List & Guida alla selezione

  1. Series Classification & Naming Rule Overview

1.1 Series Specification Classification (by Body Size & Fluire)

Codice serieLarghezza del corpoEffective AreaMax FlowSuitable CylinderApplicazione tipica
SY300010mm1.1m㎡196NL/minφ6~φ20Mini cylinder, precision control
SY500015mm2.8m㎡470NL/minφ25~φ40Small cylinder, general automation
SY700020mm5.2m㎡860NL/minφ50~φ63Medium cylinder, production line
SY900030mm11.0m㎡1780NL/minφ80~φ125Large cylinder, high flow system

1.2 Complete Naming Rule (Esempio: SY3220-5G-C4)

SegmentoCodiceSensoOptional Configuration
SYSYSeries prefixFisso
3/5/7/93Size code3=SY3000, 5=SY5000, 7=SY7000, 9=SY9000
2月3日2Codice funzione2=5/2-way, 3=5/3-way
20/40/30/31/3220Modalità di controllo20=Single-coil, 40=Dual-coil, 30=Closed center, 31=Exhaust center, 32=Pressure center
2005/4/65Tensione della bobina4=AC110V, 5=DC24V, 6=AC220V
G/LZ/LD/UEGWiring typeG=Direct outlet, LZ=Socket with indicator, LD=Socket with indicator+diode, UE=Indicator+surge protection
C4/C6/M5C4Port sizeC4=φ4mm push-in, C6=φ6mm push-in, M5=M5 thread
-Q-QCertificazioneQ=CE certified (opzionale)
  1. Full Standard Model List By Series

2.1 SY3000 Series (Mini, 10mm Width)

5/2-way Single-coil (Tipo 20)

ModelloVoltaggioTipo di cablaggioDimensione della portaCaratteristiche
SY3220-4G-C4AC110VDirect outletφ4mmTipo standard
SY3220-4G-C6AC110VDirect outletφ6mmHigh flow
SY3220-4LZ-C4AC110VSocket with indicatorφ4mmStatus visible
SY3220-5G-C4DC24VDirect outletφ4mmMost commonly used
SY3220-5G-C6DC24VDirect outletφ6mmHigh flow common
SY3220-5LZ-C4DC24VSocket with indicatorφ4mmStatus visible
SY3220-5LD-C4DC24VSocket with indicator+diodeφ4mmProtezione da inversione di polarità
SY3220-5G-M5DC24VDirect outletM5 threadThread connection
SY3220-5GUE-C4DC24VDirect outlet+indicator+surge protectionφ4mmProtezione avanzata
SY3220-6G-C4AC220VDirect outletφ4mmAC220V system compatible

5/2-way Dual-coil (Tipo 40)

ModelloVoltaggioTipo di cablaggioDimensione della porta
SY3240-5G-C4DC24VDirect outletφ4mm
SY3240-5LZ-C4DC24VSocket with indicatorφ4mm
SY3240-5G-C6DC24VDirect outletφ6mm

5/3-way (30/31/32 Tipo)

ModelloTipo di controlloVoltaggioTipo di cablaggioDimensione della porta
SY3330-5G-C4Closed CenterDC24VDirect outletφ4mm
SY3331-5G-C4Exhaust CenterDC24VDirect outletφ4mm
SY3332-5G-C4Pressure CenterDC24VDirect outletφ4mm

2.2 SY5000 Series (Medio, 15mm Width)

5/2-way Single-coil (Tipo 20)

ModelloVoltaggioTipo di cablaggioDimensione della porta
SY5220-5G-C4DC24VDirect outletφ4mm
SY5220-5G-C6DC24VDirect outletφ6mm
SY5220-5LZ-C6DC24VSocket with indicatorφ6mm
SY5220-5LD-C6DC24VSocket with indicator+diodeφ6mm
SY5220-5G-M5DC24VDirect outletM5 thread

5/2-way Dual-coil (Tipo 40)

ModelloVoltaggioTipo di cablaggioDimensione della porta
SY5240-5G-C6DC24VDirect outletφ6mm
SY5240-5LZ-C6DC24VSocket with indicatorφ6mm
SY5240-5LD-C6DC24VSocket with indicator+diodeφ6mm

5/3-way (30/31/32 Tipo)

ModelloTipo di controlloVoltaggioTipo di cablaggioDimensione della porta
SY5330-5G-C6Closed CenterDC24VDirect outletφ6mm
SY5331-5G-C6Exhaust CenterDC24VDirect outletφ6mm
SY5332-5G-C6Pressure CenterDC24VDirect outletφ6mm

2.3 SY7000 Series (Grande, 20mm Width)

ModelloFunzioneTipo di controlloVoltaggioTipo di cablaggioDimensione della porta
SY7220-5G-C65/2-waySingle-coilDC24VDirect outletφ6mm
SY7240-5G-C65/2-wayDual-coilDC24VDirect outletφ6mm
SY7330-5G-C65/3-wayClosed CenterDC24VDirect outletφ6mm
SY7331-5G-C65/3-wayExhaust CenterDC24VDirect outletφ6mm
SY7332-5G-C65/3-wayPressure CenterDC24VDirect outletφ6mm

2.4 SY9000 Series (Extra Large, 30mm Width)

ModelloFunzioneTipo di controlloVoltaggioTipo di cablaggioDimensione della porta
SY9220-5G-C65/2-waySingle-coilDC24VDirect outletφ6mm
SY9240-5G-C65/2-wayDual-coilDC24VDirect outletφ6mm
SY9330-5G-C65/3-wayClosed CenterDC24VDirect outletφ6mm
SY9331-5G-C65/3-wayExhaust CenterDC24VDirect outletφ6mm
SY9332-5G-C65/3-wayPressure CenterDC24VDirect outletφ6mm
  1. Special Specification Models (Common Derivatives)

3.1 With Mounting Bracket (Suffix F1)

For independent mounting, only available for 5/2-way single-coil models

SY3220-5G-C4-F1

SY5220-5G-C6-F1

SY7220-5G-C6-F1

3.2 CE Certified Model (Suffix -Q)

Compliant with EMC & Direttiva Bassa Tensione, widely used for European export

SY3220-5G-C4-Q

SY5220-5G-C6-Q

SY7220-5G-C6-Q

3.3 External Pilot Type (Suffix -P)

Suitable for vacuum or low-pressure environment (0~0.7MPa)

SY3220-5G-C4-P

SY5220-5G-C6-P

3.4 Clean Room Version (Suffix -C)

Suitable for Class 100 clean environment

SY3220-5G-C4-C

SY5220-5G-C6-C

  1. Compatible Manifold Models (Universale per tutte le serie)
Manifold ModelSerie applicabileNumber of StationsDimensione della portaCaratteristiche
SS5Y3-01-01SY30001-stationC4/C6/M51-station manifold
SS5Y3-05-05SY30005-stationC4/C6/M55-station manifold
SS5Y5-05-05SY50005-stationC4/C6/M55-station manifold
SS5Y7-05-05SY70005-stationC4/C6/M55-station manifold
SS5Y3-10-10DSY300010-stationC4/C6/M510-station with DIN rail
SS5Y5-20-20SY500020-stationC4/C6/M520-station manifold
  1. Selection Mnemonic

Five key points for SY selection: serie, funzione, voltaggio;

3=Mini,5=Medium,7=Large,9=Extra Large;

2=5/2-way,3=5/3-way remember clearly;

20=Single-coil,40=Dual-coil;

30=Closed,31=Exhaust,32=Pressure center;

5=24V,G=direct wire outlet;

C4 for Φ4,C6 for Φ6 tube;

Manifold mounting saves space, add F1 for standalone installation;

Add -Q for CE, add -P for external pilot.

  1. Core Selection Decision Tree
  2. Flow Demand: Mini cylinder → SY3000; Small → SY5000; Medium → SY7000; Large → SY9000
  3. Modalità di controllo: Single-acting → Single-coil(20); Reciprocating → Dual-coil(40); Mid-stop → 5/3-way(30/31/32)
  4. Voltage Match: DC24V→5; AC110V→4; AC220V→6
  5. Wiring Preference: Fixed installation→G; Frequent replacement→LZ/LD
  6. Dimensione della porta: Low flow→C4; High flow→C6; Thread→M5
  7. Montaggio: Manifold→Standard; Independent→Model with F1 bracke
  8. Cross-Series Replacement Reference
Modello originaleSostituzione dell'aggiornamentoDowngrade ReplacementMotivo della sostituzione
SY3220-5G-C4SY5220-5G-C6Upgrade when flow insufficient
SY5220-5G-C6SY7220-5G-C6SY3220-5G-C6Cylinder upsize / downsize
SY7220-5G-C6SY9220-5G-C6SY5220-5G-C6High flow demand / cost optimization