Marca: Tele Haase (Austrian manufacturer of industrial control relays)
Tipo di prodotto: Multifunction Timer Relay
Serie: ENYA E1ZM Series
Modello completo: E1ZM10 12-240VAC/DC (or E1ZM10 24-240VAC/DC)
Ordine n.: 110100 (12-240V version) / 110200 (24-240V version)
Key Specifications & Functions
| Articolo | Details |
| Tensione di alimentazione | Wide‑range design: 12‑240VAC/DC or 24‑240VAC/DC, 50/60Hz |
| Time Range | 7 selectable ranges, covering 0.05 seconds to 100 ore |
| Output Contact | 1 changeover contact (SPDT / 1CO), potential‑free |
| Contact Rating | 8A @ 250VAC, AgNi contact material |
| Dimensioni | Width 17.5mm, Height 87mm, Depth 65mm (DIN rail mount) |
| Operating Temp. | -25°C to +55°C |
| Classe di protezione | IP20 |
7 Timing Functions (set with power disconnected)
- E: ON delay
- R: OFF delay
- Ws: Leading edge single pulse with control input
- Wa: Trailing edge single pulse with control input
- Es: ON delay with control input
- Wu: OFF delay with control input
- Bp: Pulse interval (cyclic timer)
Caratteristiche & Applicazioni
Universal Compatibility: Wide voltage range suits global industrial environments without extra power conversion.
Montaggio su guida DIN: 17.5mm slim width saves control cabinet space, conforming to industrial standards.
Multifunction Integration: Replaces multiple single-function timers, reducing inventory and procurement costs.
Precise Control: High electronic timing accuracy for automated processes requiring precise sequence control.
Applicazioni: Widely used in motor control, pump and valve actuation, production line sequencing, lighting systems, safety monitoring, and other industrial automation fields.
Related Models & Alternative
Same Series: E1ZMQ10 (simplified version, 4 functions), E3ZM20 (2 changeover contacts)
Alternative Brands:
Omron H3CR Series
Siemens 3RP Series
Schneider RE7 Series
Installazione & Operating Notes
- Function selection must be set via DIP switches with power disconnected.
- Mount on standard 35mm DIN rail, maintaining adequate heat dissipation space from other devices.
- During wiring, distinguish between supply terminals, control input terminals, and output contact terminals.
- Avoid installation in environments with strong electromagnetic interference, excessive vibration, or high humidity.
Tele E1ZM 10 Multifunction Timer Relay: Cross-Brand Replacement Comparison
- Core Specifications of Original Unit
| Articolo | Specifica |
| Marca | Tele Haase (Austria) |
| Serie | ENYA E1ZM Series |
| Functions | 7 timing functions (E/R/Ws/Wa/Es/Wu/Bp) |
| Contatti | 1 changeover contact (SPDT/1CO), AgNi material |
| Contact Rating | 8A @ 250VAC |
| Dimensioni | 17.5mm (W) × 87mm (H) × 65mm (D), DIN rail mount |
| Supply | 12‑240VAC/DC or 24‑240VAC/DC, 50/60Hz |
| Time Range | 7 adjustable ranges, 0.05s to 100h |
| Operating Temp. | -25°C to +55°C |
| Classe di protezione | IP20 |
- Cross-Brand Replacement Comparison Table
| Marca | Modello sostitutivo | Contact Rating | Larghezza | Tensione di alimentazione | Time Range | Differenze chiave |
| Schneider | RE17RMMW | 8UN | 17.5mm | 12‑240VAC/DC | 0.1s‑100h | More functions, slightly different timing accuracy |
| Schneider | RE17RAMU | 8UN | 17.5mm | 24‑240VAC/DC | 0.1s‑100h | Narrower voltage range, otherwise identical |
| Siemens | 3RP1505‑1AP30 | 8UN | 22.5mm | 24‑240VAC/DC | 0.05s‑100h | 5mm wider, slightly different functions |
| Omron | H3RN‑8 Series | 8UN | 17.5mm | 24‑240VAC/DC | 0.1s‑100h | Different starting time, no 12VAC/DC support |
| Crouzet | MXR1 | 8UN | 17.5mm | 12‑240VAC/DC | 0.05s‑10 days | Longer max timing, more versatile functions |
| Littelfuse | TMM175 | 8UN | 17.5mm | 12‑240VAC/DC | 0.1s‑100h | Solid‑state output, no mechanical contact wear |
| ASQU/ASTU | ASQU108MV1 | 8UN | 17.5mm | 12‑240VAC/DC | 0.5s‑10 days | Fewer functions, different time range |
| Tele Haase | E1ZMQ10 | 8UN | 17.5mm | 24‑240VAC/DC | 0.05s‑100h | Same‑brand simplified version, fewer functions, lower cost |
- Detailed Replacement Descriptions
- Schneider RE17R Series
RE17RMMW: Ideal direct replacement. 17.5mm width matches perfectly, 12-240VAC/DC wide voltage, 10 timing functions (3 more than E1ZM10), 8A contact rating, time range 0.1s to 100h, DIN rail mount, IP20.
RE17RAMU: Suitable where 12V supply is not required; otherwise identical to RE17RMMW.
- Siemens 3RP15 Series
3RP1505-1AP30: Similar functions but 22.5mm width (5mm wider than E1ZM10), which may affect cabinet layout. Offers 8 timing functions, with 0.05s start time matching the original; suitable where space permits.
- Omron H3RN-8 Series
H3RN-81 24-240VAC/DC: 17.5mm slim width, 8 timing functions, 8A contact rating, but time range starts at 0.1s and does not support 12VAC/DC; suitable where low-voltage operation is not needed.
- Crouzet MXR1 Series
MXR1: 17.5larghezza mm, 10 timing functions, 12-240VAC/DC wide voltage, ultra-long timing range 0.05s to 10 days, 8A contact rating; ideal for applications requiring extended timing.
- Littelfuse TMM175 Series
TMM175: Solid-state multifunction timer, 17.5larghezza mm, 10 timing functions, 12-240VAC/DC wide voltage, 8A output, no mechanical contacts, longer service life; suitable for high-frequency operation.
- Replacement Selection Recommendations
- Best Direct Replacement: Choose Schneider RE17RMMW. All key parameters match Tele E1ZM 10 except starting time (0.1s vs 0.05s), with richer functions and identical mounting dimensions.
- Space-Constrained Applications: Prioritize 17.5mm width models (Schneider RE17R Series, Crouzet MXR1, Littelfuse TMM175, Omron H3RN-8) to avoid width issues with Siemens 3RP15 (22.5mm).
- 12V Supply Requirement: Select models supporting 12-240VAC/DC (Schneider RE17RMMW, Crouzet MXR1, Littelfuse TMM175), avoiding types with only 24-240V such as RE17RAMU and E1ZMQ10.
- Function Matching:
For original 7 functions: Schneider RE17RMMW (10), Siemens 3RP15 (8), Crouzet MXR1 (10) all cover requirements.
Simplified use: Tele E1ZMQ10 (4 functions) offers best same-brand compatibility and lower cost.
- Long-Term Reliability: Consider Littelfuse TMM175 solid-state timer with no mechanical contact wear, ideal for high-cycle applications.
- Same-Brand Replacements & Upgrades
E1ZMQ10: Simplified version from Tele Haase, 4 timing functions, 24-240VAC/DC supply, lower cost for basic applications.
E3ZM20: Upgraded same-brand model, 2 changeover contacts (2CO), 8A×2 rating, otherwise identical to E1ZM10; suitable for dual-output requirements.
Full Product Range of Tele Haase (Tele Brand)
Tele Haase is an Austrian manufacturer specializing in industrial control relays, focusing on the development and production of timer relays, monitoring relays, switching relays, and power electronic devices. Below is its complete product portfolio:
- Timer Relay Series
1.1 ENYA Series (17.5mm Slim Width)
| Sub‑series | Model Examples | Caratteristiche | Intervallo di tensione | Configurazione dei contatti |
| E1ZM | E1ZM10, E1ZM20, E1ZMQ10, E1ZMW10 | 7 timing functions, 0.05s‑100h | 12‑240VAC/DC or 24‑240VAC/DC | 1CO or 2CO |
| E1Z1 | E1Z1E10, E1Z1R10, E1Z1ER10 | Single / dual function (E/R/ER) | 24‑240VAC/DC | 1CO |
| E3ZM | E3ZM20 | 2 changeover contacts, 8 timing functions | 12‑240VAC/DC | 2CO |
| E1YF | E1YF10, E1YF20 | Dedicated star‑delta timer | 24‑240VAC/DC | 2CO |
1.2 VEO Series (22.5mm Width)
| Sub‑series | Model Examples | Caratteristiche | Intervallo di tensione | Configurazione dei contatti |
| V2ZQ | V2ZQ10, V2ZQ20 | 8 timing functions, 0.05s‑10 days | 24‑240VAC/DC | 1CO or 2CO |
| V2Z1 | V2Z1E10, V2Z1R10 | Single / dual function timer | 24‑240VAC/DC | 1CO |
| V3ZQ | V3ZQ20 | 2 changeover contacts, 8 timing functions | 24‑240VAC/DC | 2CO |
1.3 GAMMA Series (22.5mm Width, with Display)
| Sub‑series | Model Examples | Caratteristiche | Intervallo di tensione | Configurazione dei contatti |
| G2ZM | G2ZM10, G2ZM20, G2ZMF11 | Digital display, 8 timing functions | 24‑240VAC/DC | 1CO or 2CO |
| G2Z1 | G2Z1E10, G2Z1R10 | Digital display, single / dual function | 24‑240VAC/DC | 1CO |
| G3ZM | G3ZM20 | Digital display, 2 changeover contacts | 24‑240VAC/DC | 2CO |
1.4 KAPPA Series (Premium Multifunction Timers)
| Sub‑series | Model Examples | Caratteristiche | Intervallo di tensione | Configurazione dei contatti |
| K4ZM | K4ZM20 | 10 timing functions, digital display, ampia tensione | 12‑240VAC/DC | 2CO |
| K4Z1 | K4Z1E10, K4Z1R10 | Digital display, single / dual function | 24‑240VAC/DC | 1CO |
1.5 COMBI Series (Plug-in Timer Modules)
| Sub‑series | Model Examples | Caratteristiche | Compatible Base | Time Range |
| COM3T | COM3T | 8 timing functions, plug‑and‑play | RT Series industrial relay bases | 0.05s‑10 days |
| COM4T | COM4T | 10 timing functions, digital display | RT Series industrial relay bases | 0.05s‑10 days |
- Monitoring Relay Series
2.1 Monitoraggio della tensione
| Serie | Model Examples | Monitoring Functions | Intervallo di tensione | Configurazione dei contatti |
| E1PF | E1PF400VS01, E1PF400VSY01 | Phase sequence / failure / Sopra / under voltage | 24‑240VAC/DC | 1CO or 2CO |
| E3PF | E3PF400VS01 | Three‑phase voltage monitoring, 2 changeover contacts | 24‑240VAC/DC | 2CO |
| E1UF | E1UF230VS01 | Single‑phase over / under voltage | 24‑240VAC/DC | 1CO |
2.2 Current Monitoring
| Serie | Model Examples | Monitoring Functions | Current Range | Intervallo di tensione |
| E1IM | E1IM10AACL10, E1IM10AACL20 | Single‑phase over / under current | 0.1‑100A | 24‑240VAC/DC |
| E3IM | E3IM10AL20 | Three‑phase current monitoring | 0.1‑100A | 24‑240VAC/DC |
| E1IM‑F | E1IM‑F10AACL10 | Earth‑fault monitoring | 0.001‑1A | 24‑240VAC/DC |
2.3 Power Monitoring
| Serie | Model Examples | Monitoring Functions | Measured Parameters | Tipo di uscita |
| E1PM | E1PM400VS01 | Fattore di potenza / active power monitoring | PF, P, IO, U | 1CO + analog output |
| E3PM | E3PM400VS01 | Three‑phase power monitoring | PF, P, IO, U | 2CO + analog output |
2.4 Temperature Monitoring
| Serie | Model Examples | Input Type | Intervallo di temperatura | Intervallo di tensione |
| E1TF | E1TF230VT01 | Thermocouple / RTD input | -50°C to +250°C | 24‑240VAC/DC |
| E3TF | E3TF230VT01 | Dual‑channel temperature monitoring | -50°C to +250°C | 24‑240VAC/DC |
2.5 Load Monitoring
| Serie | Model Examples | Monitoring Functions | Applicazione | Configurazione dei contatti |
| E1BF | E1BF230VT01 | Motor stall / sovraccarico / phase failure | Induction motor protection | 1CO |
| E3BF | E3BF400VT01 | Comprehensive three‑phase motor protection | Large motor protection | 2CO |
- Switching Relay Series
3.1 Miniature Relays
| Serie | Tipo | Configurazione dei contatti | Contact Rating | Montaggio |
| RA | Blade‑type miniature relay | 1CO/2CO | 10A@250VAC | Socket mount |
| RM | Blade‑type miniature relay | 1CO/2CO/3CO | 10A@250VAC | Socket mount |
| RP | PCB power relay | 1CO/2CO | 10A@250VAC | PCB mount |
3.2 Industrial Relays
| Serie | Tipo | Configurazione dei contatti | Contact Rating | Montaggio |
| RT | 8/11‑pin industrial relay | 1CO/2CO/3CO | 10A@250VAC | Socket mount |
| RT‑COM | RT with timer module | 1CO/2CO/3CO + 8 timing functions | 10A@250VAC | Socket mount |
3.3 Slim Interface Relays
| Serie | Larghezza | Configurazione dei contatti | Contact Rating | Montaggio |
| SKR | 6.2mm | 1CO | 6A@250VAC | DIN rail mount |
| STKR | 12.5mm | 2CO | 6A@250VAC | DIN rail mount |
- Power Monitoring & Conversion Devices
4.1 Current Transformers
| Serie | Tipo | Measuring Range | Output Signal | Alimentazione elettrica |
| V4IA | Active current transformer | 0‑100A | 4‑20mA / 0‑10V | 24‑240VAC/DC |
| S9IA | Passive current transformer | 0‑3000A | 5UN / 1UN | Nessuno |
| V4IB | Dual‑output current transformer | 0‑100A | 4‑20mA + 5UN | 24‑240VAC/DC |
4.2 Signal Converters
| Serie | Funzione | Input Signal | Output Signal | Intervallo di tensione |
| E1CF | Current/voltage conversion | 0‑5A / 0‑1A | 4‑20mA / 0‑10V | 24‑240VAC/DC |
| E1VF | Voltage/current conversion | 0‑230V / 0‑400V | 4‑20mA / 0‑10V | 24‑240VAC/DC |
4.3 Hour Meters
| Serie | Tipo | Counting Range | Intervallo di tensione | Display |
| E1ZH | Electronic hour meter | 0‑99999.9h | 24‑240VAC/DC | schermo LCD |
| E3ZH | Three‑phase hour meter | 0‑99999.9h | 24‑240VAC/DC | schermo LCD |
- Power Electronics
5.1 Soft Starters
| Serie | Tipo | Power Range | Metodo di controllo | Protection Features |
| TSG | Compact soft starter | 0.75‑75kW | Voltage ramp control | Overcurrent / sovraccarico / phase failure |
| MSG | Semiconductor soft starter | 0.75‑200kW | Thyristor control | Comprehensive motor protection |
5.2 Thyristor Controllers
| Serie | Tipo | Power Range | Applicazione | Control Signal |
| TSC | Single‑phase thyristor controller | 0‑50kW | Carichi resistivi | 4‑20mA / 0‑10V |
| TTC | Three‑phase thyristor controller | 0‑200kW | Motors / riscaldatori | 4‑20mA / 0‑10V |
- Modular Monitoring Systems
WatchDog pro Series
Main Unit: WD-PRO-CU | Comunicazione: Ethernet, RS485, SMS, E-mail
Moduli di espansione: WD-PRO-IM (current monitoring), WD-PRO-VM (voltage monitoring), WD-PRO-TM (temperature monitoring)
Applicazioni: Distributed energy systems, industrial automation lines, smart building energy management
- Special-Function Relays & Accessories
7.1 Special-Function Relays
| Serie | Funzione | Model Examples | Applicazione |
| E1ZM‑ER | Combined ON + OFF delay | E1ZM‑ER10 | Complex sequence control |
| E1ZM‑BP | Pulse interval timer | E1ZM‑BP10 | Intermittent equipment control |
| E1ZM‑Ws | Leading edge single pulse | E1ZM‑Ws10 | Trigger signal control |
7.2 Accessories
Relay Sockets: Special sockets for RA/RM/RP/RT series
Mounting Bases: DIN rail brackets, panel mount adapters
Test Tools: Relay function testers, signal simulators
Marking System: Product labels, terminal markers
- Product Naming Convention
Tele Haase model numbers generally follow this structure:
1st character: E = 17.5mm width, V = 22.5mm width, G = with display, K = premium
2nd character: 1 = single function / 1 contatto, 2 = dual function, 3 = 2 contatti
3rd character: Z = timer, P = phase monitoring, U = voltage monitoring, I = current monitoring, M = power monitoring
4th character: M = multifunction, 1 = single function, F = monitoring
Suffix: 10 = 1 changeover contact, 20 = 2 changeover contacts, VS01 = voltage monitoring, ACL10 = current monitoring
Contattore,interruttore automatico,inverter solare,contatore elettrico,batterie solari