Telemecanique XS618B1MAL2 Inductive Proximity Sensor - Contattore,interruttore automatico,sensore,Codificatore,PLC,Convertitore

Wechat: +86-13184948252 Whatsapp: 0086-13811255435 E-mail: kent@bestcontactor.com

Di Contatto |

 Telemecanique XS618B1MAL2 Inductive Proximity Sensor - Contattore,interruttore automatico,sensore,Codificatore,PLC,Convertitore

Sensore/

Telemecanique XS618B1MAL2 Inductive Proximity Sensor

M18 Flush-mount Inductive Proximity Switch (2-wire AC/DC universal, Normalmente aperto NO) Model Code Explanation XS6: General-purpose inductive proximity sensor of XS6 series 18: M18 threaded cylinder B: Standard sensing distance 1: Normalmente aperto (NO) M: 2-wire AC/DC universal A: Cable outlet L2: 2-meter fixed cable Core Electrical & Mechanical Specifications Item Parameter Nominal Sensing Distance ...

  • Dettagli del prodotto

M18 Flush-mount Inductive Proximity Switch (2-wire AC/DC universal, Normalmente aperto NO)

  1. Spiegazione del codice modello

XS6: Uso generale sensore di prossimità induttivo of XS6 series

18: M18 threaded cylinder

B: Standard sensing distance

1: Normalmente aperto (NO)

M: 2-wire AC/DC universal

UN: Uscita cavo

L2: 2-meter fixed cable

  1. Nucleo elettrico & Specifiche meccaniche
ArticoloParametro
Distanza di rilevamento nominale Sn8 mm, montaggio ad incasso (shielded type)
Tensione di alimentazione24…240 V CA/CC (50/60Hz)
Tipo di uscita2-filo, Normalmente aperto (NO)
Carica correnteDC: 5~200mA; AC: 5~300mA
Body Length62 mm; Thread M18×1
Materiale dell'alloggiamentoOttone nichelato; Sensing face PPS
Cavo2cavo fisso da m
Classe di protezioneIP68 / IP69K, double insulation
Temperatura operativa-25℃ ~ +70 ℃
Frequenza di commutazione1kHz
Detected ObjectMetallic conductors (optimal for ferromagnetic metals)
  1. Linee guida per l'installazione
  2. Montaggio a incasso (Shielded Type): The sensor can be fully embedded inside a metal mounting seat without false triggering caused by side metal.
  3. Mounting hole M18, supplied with double lock nuts.
  4. Minimum spacing between adjacent sensors of the same model ≥3×Sn (≥24mm) to prevent mutual interference.
  5. Target metal plate thickness ≥1mm, area ≥30×30mm for stable detection.
  6. Istruzioni di cablaggio

2-wire design, non polarizzato (AC/DC universale):

Connect two wires in series between power supply and load.

When metal approaches the sensing face → switch turns ON (NO contact closed).

Nota: 2-wire sensors carry standby leakage current. False actuation may occur with low-power loads (high-resistance relay coils). Load calculation is required during selection.

  1. Scenari applicativi tipici

Metal detection on conveyor lines, machine tool limit positioning, material presence detection, hydraulic/cylinder position feedback, food processing washdown equipment (IP69K for high-pressure cleaning), macchine per l'imballaggio.

  1. Alternativa / Equivalent Models within the Series

XS618B1MBL2: 2-wire Normally Closed NC, altri parametri identici

XS618B1PAM12: 3-filo PNP normalmente aperto, M12 connector type

XS618B1NAM12: 3-filo NPN normalmente aperto, M12 connector type

  1. Risoluzione dei problemi comuni
  2. Nessuna uscita: Verify supply voltage within 24~240V; confirm metal target enters the 8mm sensing range; inspect cable for breakage.
  3. Falsa attivazione: For flush mounting, ensure mounting metal does not cling to the sensing face; check interference from neighboring sensors.
  4. Cannot turn off: Too small load; leakage current of 2-wire sensor keeps relay energized. Replace with 3-wire PNP/NPN version.

Operating Principle of Flush-mount Inductive Proximity Switches (such as XS618B1MAL2)

Basic Principle

Inductive proximity switches work based on the eddy current effect, with a high-frequency oscillating coil as the core component.

  1. Internal circuit generates a high-frequency alternating magnetic field, radiating outward from the front sensing face.
  2. Quando un bersaglio metallico si avvicina alla superficie sensibile, the alternating magnetic field induces eddy currents on the metal surface.
  3. Eddy currents generate a reverse magnetic field to counteract the original oscillating magnetic field of the sensor.
  4. The amplitude of the oscillation circuit attenuates; detection circuit identifies this change and outputs switching signal (ACCESO/SPENTO).

✅ Core difference between Flush-mount (Shielded) and Non-flush (Non schermato): A metal shielding ring surrounds the coil

Structural Features of Flush-mount (Shielded Type)

A metal shielding layer wraps the sides of the sensing coil for flush-mount sensors:

Restricts magnetic field to directly in front of the sensor, nearly no magnetic field on lateral sides.

Perciò, it can be fully screwed into metal mounting brackets with sensor end face flush to mounting surface and no false triggering from surrounding metal.

Trade-off: Under identical specifications, sensing distance is shorter than non-flush type (Sn=8mm for XS618B1MAL2 flush model).

Non-flush type: Magnetic field exists on sides; cannot be embedded in metal seat, otherwise continuous triggering occurs, with longer sensing distance.

Signal Output Flow (2-wire NO model XS618B1MAL2)

  1. Power on → internal oscillator starts oscillation.
  2. No metal nearby → stable oscillation, switch open (NONormalmente aperto).
  3. Metal approaches and reaches rated sensing distance Sn → oscillation attenuates, detection circuit actuates and the 2-wire circuit conducts.
  4. Metal moves away → oscillation recovers, switch opens.

Caratteristiche chiave

  1. Only detects metal: Plastica, wood and glass cannot produce eddy currents and will not be detected. Ferromagnetic metals (acciaio, iron) deliver optimal sensing distance; effective distance attenuates for non-ferrous metals such as copper and aluminum.
  2. Velocità di risposta rapida, suitable for high-speed counting and position detection.
  3. Flush mounting resists side metal interference, preferred for machine tools, conveyor metal frame installations.
  4. 2-wire version carries leakage current; load selection needs attention.

Simple Comparison Table

TipoStrutturaFunzionalità di montaggioDistanza di rilevamento
Flush-mount (Shielded)Coil with metal shielding ringCan be flush embedded into metal holesShorter
Non a filo (Non schermato)No side shieldingCannot embed into metal; front clearance requiredLonger

Common Application Scenarios of Inductive Proximity Switches

Funzionalità principali: Detect metal only, non-contact, nessuna usura meccanica, resistant to dust and oil; Flush type (XS618B1MAL2) suitable for flush installation on metal frames

  1. Rilevamento della posizione / Travel Limit (Più comune)
  2. Cylinder position feedback: Detect extended/retracted end position of cylinder piston rod to confirm completion of cylinder action, standard fitting for pneumatic automation; M18 flush sensors widely used on cylinder mounting seats.
  3. Machine tool travel limit: Soft limit and hard overtravel protection for CNC machine slides and worktables; turret and tool magazine positioning, tool change confirmation; fixture clamping verification to judge workpiece seating status.
  4. Valvola, baffle and safety door status detection: Detect closure of metal safety gates for safety interlock; equipment startup prohibited when door open.
  5. Robot positioning: Homing and station in-place detection for robotic arms.
  6. Conteggio, Speed Measurement & Rotational Speed Monitoring
  7. Metal workpiece counting on conveyor lines: Count metal parts, viti, metal caps and metal pallets on production lines for output statistics.
  8. Rotational speed / line speed acquisition: Gear tooth disc fitted on motor shaft; proximity sensor detects gear teeth pulses, PLC collects pulses to calculate rotation speed and line speed, widely used for conveyors and reducer spindle monitoring.
  9. Material break / shortage detection: Monitor feeding of metal rods to confirm material delivery and breakage.
  10. Trasmettere & Smistamento logistico
  11. Detect arrival of metal workpieces on belt conveyors to trigger cylinder actions for transfer and sorting;
  12. Metal pallet presence detection and rack positioning in automated warehouses;
  13. Jam monitoring: Alarm for material accumulation and blockage.
  14. Confezione & Macchine alimentari (Suitable for XS618B1MAL2 with IP68/IP69K)

Detection of cans, metal caps and aluminum foil seals to verify cap presence;

Trigger filling when metal containers arrive at filling stations;

High-pressure washdown capability; flush sensors preferred for food & beverage cleaning lines.

  1. Produzione automobilistica

Workpiece positioning at welding stations and fixture clamping confirmation for welded car bodies;

Gear position detection for gearboxes and presence check of wheel hubs;

Stable performance under welding slag and heavy dust; inductive sensors outperform photoelectric sensors in contaminated environments.

  1. Idraulico & Macchine edili

Hydraulic cylinder position detection and metal float liquid level monitoring;

Position feedback for machinery doors and buckets;

Adapt to heavy vibration and oily harsh environments.

  1. Other Segmented Applications
  2. Attrezzature per lo stampaggio: Mold closure detection and safety interlock;
  3. Electronic equipment: Metal component detection on SMT lines;
  4. Pompa & fan: Shaft stall monitoring via gear tooth speed measurement.

Suggerimenti per la selezione (For XS618B1MAL2)

✅ Flush-mount (Shielded Type): Can be installed flush within metal mounting seats, free from false triggering by surrounding metal; preferred for machine frames and cylinder mounts.

⚠️ Limitazione: Only identifies metal, plastica, paper and non-metallic workpieces cannot be detected; effective sensing distance shortens for copper and aluminum.

⚠️ 2-wire models (per esempio. XS618B1MAL2) have leakage current, which may cause false pull-in of small-load relays.

Telemeccanica XS618B1 Series Full Model List (M18 Flush Mount, Sn=8mm)

Unified Base Specification: XS618B1 = XS6 series, M18 threaded, flush shielded type, nominal sensing distance 8mm, nickel-plated brass housing, IP68/IP69K, -25~+70℃

Regola di codifica del modello: XS618B1 + Output Code + Tipo di uscita + Length/Connector

M = 2-wire AC/DC; P=PNP; N=NPN

A=Normally Open NO; B=Normally Closed NC

L2=2m cable; L5=5m cable; M12=M12 circular connector; AU20=1/2″UNF connector

  1. 2-wire AC/DC (Branch of XS618B1MAL2, 24~240 V CA/CC)
ModelloProduzioneCablaggioPresaOsservazioni
XS618B1MAL2NO2-filo2cavo da mModello di riferimento, Body L=62mm
XS618B1MBL2NC2-filo2cavo da mSame specs as MAL2
XS618B1MAU20NO2-filo1/2″UNF connectorAmerican thread connector, L=73mm
XS618B1MBU20NC2-filo1/2″UNF connectorNormally closed version with American connector
  1. 3-wire DC PNP (12~48VDC, most common for PLC)
ModelloProduzioneCablaggioPresaOsservazioni
XS618B1PAL2NO3-wire PNP2cavo da mL=62mm
XS618B1PBL2NC3-wire PNP2cavo da mL=62mm
XS618B1PAL5NO3-wire PNP5cavo da mLong cable version
XS618B1PBL5NC3-wire PNP5cavo da mLong cable normally closed
XS618B1PAM12NO3-wire PNPConnettore M12 a 4 pinL=74mm
XS618B1PBM12NC3-wire PNPConnettore M12 a 4 pinL=74mm
  1. 3-wire DC NPN (12~48VDC, for NPN-type PLC)
ModelloProduzioneCablaggioPresaOsservazioni
XS618B1NAL2NO3-wire NPN2cavo da m62mm body
XS618B1NBL2NC3-wire NPN2cavo da m62mm body
XS618B1NAM12NO3-wire NPNConnettore M1274mm body
XS618B1NBM12NC3-wire NPNConnettore M1274mm body
  1. ATEX Dust Explosion-proof Versions (Explosive Atmosphere)
ModelloProduzioneCablaggioPresaOsservazioni
XS618B1PAL10EXNOPNP10cavo da mATEX dust hazardous area
XS618B1PBL10EXNCPNP10cavo da mATEX dust hazardous area

Guida alla selezione rapida

  1. 2-wire models starting with M (XS618B1MAL2): Universal AC/DC, no polarity distinction; ⚠️ leakage current exists, prone to false relay pull-in for tiny loads, adatto per carichi pesanti.
  2. 3-wire P/N prefix: DC12~48V, PNP/NPN, protezione da cortocircuito, standard PLC selection, preferred replacement for 2-wire sensors.
  3. Suffix L2/L5: Fixed cable; M12/AU20: Detachable connector for easier maintenance.
  4. A=NO Normally Open, B=NC Normally Closed: When metal approaches, NO closes and NC opens.

Extended M18 Flush Models in the Same Series (Longer Sn, Non-B1)

XS618B4PAL2: Montaggio a incasso, Sn12mm, PNP n, 2cavo da m

Prec:

Lascia una risposta

Lasciate un messaggio