In the model numbers of the CHINT AC contactor CJX2 series, the meaning of the four-digit suffix is mainly related to the rated current and the configuration of auxiliary contacts, and the specific rules are as follows:
- Decomposition and Meanings of the Four-digit Number
Take the common models CJX2-1210 and CJX2-0901 as examples:
- The first two digits (ad esempio 12, 09)
They represent the rated current of the contactor, with the unit being amperes (UN).
– Per esempio:
12 indicates that the rated current is 12A (suitable for small and medium-sized loads, such as lighting and small motors);
09 indicates that the rated current is 9A (suitable for low-load scenarios).
Special instructions:
– For some models, there may be “rounding” or approximate values. Per esempio, the rated current of CJX2-1810 is 18A, but it may be marked as 17.5A in the actual product manual (it is necessary to refer to the official parameters).
– If the model contains a letter (such as CJX2-1210N), “N” usually indicates a reversible contactor, but the meaning of the four-digit number remains unchanged.
- The last two digits (ad esempio 10, 01)
They represent the quantity and type of auxiliary contacts, in the format of “number of normally open contacts + number of normally closed contacts”.
– Per esempio:
10 indicates 1 contatto normalmente aperto (NO) E 0 normally closed contacts (NC);
01 indicates 0 normally open contacts and 1 contatto normalmente chiuso;
22 indicates 2 normally open contacts and 2 normally closed contacts (Per esempio, in CJX2-4011, the last two digits “11” indicate 1NO + 1NC).
Special instructions:
– For some models, the functions may be further distinguished by “letter suffixes”. Per esempio, “04” in CJX2-1204N indicates 0 normally open contacts and 4 normally closed contacts, but this type of model is relatively rare, and it is necessary to confirm in combination with the specific product parameters.
- Examples of Typical Models and Parameter Correspondences
| Modello | Corrente nominale (UN) | Configuration of Auxiliary Contacts | Scenari applicativi |
| CJX2-0910 | 9 | 1NO | Circuiti di illuminazione, control of small relays |
| CJX2-1201 | 12 | 1NC | Motor protection circuits (normally closed signal feedback) |
| CJX2-1810 | 18 | 1NO | Small and medium-sized motors (such as below 1.5kW) |
| CJX2-2501 | 25 | 1NC | Control of industrial equipment (requiring normally closed signals) |
| CJX2-4011 | 40 | 1NO + 1NC | Complex logic control (such as star-delta starting) |
III. Association between Other Key Parameters and Models
- Number of Poles (Pole)
It is usually not directly reflected in the four-digit number, and it is necessary to confirm through the model suffix or product description.
– Per esempio:
CJX2-1210N 220V indicates a 3-pole (3P) reversible contactor, suitable for three-phase motor control;
CJX2-6504N indicates a 4-pole (4P) contattore, used in special power distribution scenarios.
- Tensione della bobina
The voltage information may be included in the model, but it is necessary to judge in combination with the complete model.
– Per esempio:
CJX2-1210 24V indicates that the coil voltage is 24V AC;
CJX2-1801 380V indicates that the coil voltage is 380V AC.
- Certificazioni e standard
CE certification: Complies with the EN 60947-4-1 standard (low-voltage switchgear and controlgear);
Certificazione CCC: Models sold in China need to pass the China Compulsory Certification.
- Suggerimenti per la selezione e l'utilizzo
- Select the Rated Current According to the Load Current
Principio: The rated current of the contactor ≥ 1.2 times the load current (considering the motor starting impact).
Esempio: When controlling a 10A motor, CJX2-1210 (12UN) should be selected instead of CJX2-0910 (9UN).
- Select the Auxiliary Contacts According to the Control Logic
Normally open contacts (NO): Used for signal output (such as start indication);
Normally closed contacts (NC): Used for safety interlocking (such as emergency stop circuits).
- Pay Attention to Environmental and Installation Requirements
Protection level: Usually IP20 (protection against finger contact), and models with an IP55 or above protection level need to be selected for special scenarios;
Metodo di installazione: Supports rail installation (35mm standard), which is convenient for quick replacement.
- Official Documents and Verification
For further confirmation, you can refer to the CHINT official website or product manuals. Per esempio:
– The technical parameters of CJX2-1210 clearly state “rated current 12A, auxiliary contact 1NO”;
– The manual of CJX2-0901 states “9UN, 1NC auxiliary contact”.
Through the above rules, users can quickly identify the core parameters of the CJX2 contactor to ensure accurate model selection.
Contattore,interruttore automatico,inverter solare,contatore elettrico,batterie solari