YORK (Johnson Controlli) 025W29964-000 Temperature Sensor - Contattore,interruttore automatico,sensore,Codificatore,PLC,Convertitore

Wechat: +86-13184948252 Whatsapp: 0086-13811255435 E-mail: kent@bestcontactor.com

Di Contatto |

 YORK (Johnson Controlli) 025W29964-000 Temperature Sensor - Contattore,interruttore automatico,sensore,Codificatore,PLC,Convertitore

Sensore/

YORK (Johnson Controlli) 025W29964-000 Temperature Sensor

Nome del prodotto: NTC Water Temperature Sensor (Copper Immersion Temperature Probe) Genuine OEM spare part for YORK centrifugal chillers, part of the sensor series for YMC2 magnetic bearing centrifugal chillers ✅ Basic Specifications Type: NTC thermistor sensor Nominal resistance: 3K @25°C (NTC3855) Sonda: Copper encapsulated immersion probe with fast response Equipped with original factory connector, directly ...

  • Dettagli del prodotto

Nome del prodotto: NTC Water Sensore di temperatura (Copper Immersion Temperature Probe)

Genuine OEM spare part for YORK centrifugal chillers, part of the sensor series for YMC2 magnetic bearing centrifugal chillers

✅ Specifiche di base

Tipo: NTC thermistor sensor

Nominal resistance: 3K @25°C (NTC3855)

Sonda: Copper encapsulated immersion probe with fast response

Equipped with original factory connector, directly pluggable into the unit’s OptiView control board

Applicazione: Supply/return chilled water, cooling water, temperatura di scarico, drive module temperature measurement and freeze protection

📌 Suffix Differentiation for the Same Series (Critical for Replacement)

025W29964-000: Basic water temperature probe

025W29964-001: Same electrical curve, differs in cable length and connector assembly

025W29964-002: Standard probe for VSD drive cooling protection kit, most widely used for YMC2

025W29964-004: Upgraded replacement version, accuracy ±2°C, interchangeable with 002

Nota: 000, 001, 002, 004 share identical electrical curves. Differences lie in cable length, connector sheath and mounting base. Direct interchange is not allowed on some unit models. Always purchase according to the unit spare parts list.

Compatible Units

YORK YMC2 magnetic bearing centrifugal chillers (Johnson Controls magnetic levitation chillers). Also applicable to selected YK and YV centrifugal models for evaporator/condenser water temperature and VSD variable frequency drive temperature monitoring.

🛠️ Fault Diagnosis

  1. Controller reports temperature sensor fault, unstable temperature reading or reading stuck at extreme values
  2. Measurement with multimeter resistance mode: ca. 3kΩ at 25°C; resistance decreases as temperature rises
  3. Fallimenti comuni: danni al cavo, water ingress and corrosion at connector, thermistor drift inside copper probe

📎 Remarks

Marking notation: `025W29964-000` / `025-29964-000` refer to the same part; W is just a separator variant

Replacement guideline: Genuine OEM part is preferred. Alternative sensors must match the 3K NTC3855 curve, otherwise the chiller will trigger faults and false freeze protection

025W29964-000 (NTC3855, R25=3000Ω, B25/50=3855K)

For YORK YMC2 magnetic bearing chiller, original curve for multimeter maintenance reference. Intervallo di temperatura: -20°C~80°C (normal operating water temperature range of the unit)

Temp°CResistance kΩTemp°CResistance kΩ
-2017.92352.34
-1514.7402.05
-1012.12451.81
-510.05501.6
08.38551.42
57.04601.27
105.96651.14
155.08701.03
204.36750.93
253800.85
302.64

 

Note supplementari

  1. Power off the unit and isolate the probe from the chiller, wait until temperature stabilizes before measurement, to avoid reading deviation caused by board power supply and self-heating effect
  2. Tolleranza: Original ±1%. Replacement sensors must strictly comply with NTC3855 / 3K@25°C. Mismatched B-value will trigger sensor faults
  3. Shared curve for freeze protection and VSD drive temperature probes
  4. Temperatures below -20°C and above 80°C are rarely used on the unit. Gamma estesa (-40~120°C) table is available upon request

Quick Fault Judgement

Measured resistance deviates significantly from 3kΩ at 25°C → Failed probe

Resistenza infinita: Internal open circuit; Resistance close to 0: Cortocircuito interno

YORK (Johnson Controlli) Chiller Temperature Sensor List (025 Serie, mainly for centrifugal / magnetic bearing chillers, including 025W29964)

Nota: Two writing formats for part numbers 025-XXXX-XXX/ 025WXXXX-XXX represent the same spare part. All are NTC thermistors, sorted by compatible unit and measurement location

  1. Sensors for YMC2 Magnetic Bearing Centrifugal Chiller (3K@25°C, B=3855, same series as the referenced model)
Parte n.DescrizioneOsservazioni
025W29964-000Immersion water temperature sensor (evaporator/condenser/drive cooling)Modello base, 3K NTC3855
025W29964-001Water temperature probe with identical curveVariation in cable and sheath
025W29964-002Drive module cooling temperature probe (standard for kit)Most popular for YMC2
025W29964-004Upgraded replacementCan replace 002, accuracy ±2°C
  1. YK Traditional Centrifugal Chiller (R134a/R1234ze) Acqua & Refrigerant Temperature Probes
Parte n.DescrizioneOsservazioni
025-47669-000Fornitura & return water temperature sensorYK evaporator inlet / outlet water
025-47673-000Refrigerant temperature sensorScarico / saturated refrigerant temperature
025-28935-000Water temperature NTC probeOlder YK F/G/H models
025-34159-000Refrigerant temperature sensorEarly YK units
025-52739-000Fornitura & return water probeNew generation YK
025-52740-000Spare water temperature probeMatched with 52739
025-53145-000Fornitura & return water temperature sensorReplacement for 025-52739-000
  1. Oil Temperature & Bearing Temperature Sensors (Centrifugal Compressor Dedicated)
Parte n.DescrizioneOsservazioni
025-34177-000Oil sump temperature sensorYK oil tank temperature
025L02246-000Bearing temperature probeCompressor bearing temperature monitoring
025-39517-000Oil supply temperature sensorOil system monitoring
  1. YV Variable Speed Centrifugal, YVAA/YVFA Water-Cooled Chillers
Parte n.DescrizioneOsservazioni
025W39721-001Water temperature probeYV series
025W39721-002Immersion water temperature sensorYVAA/YVFA
025-40334-000Refrigerant temperature sensorYV compressor discharge
  1. Screw Chiller (YS/YEWS) Sensori di temperatura
Parte n.DescrizioneOsservazioni
025W48195-001Acqua / discharge temperature sensorYS screw chiller
S1-025-49696-000Coil temperature sensor (10K)Commercial air-cooled screw & heat pump
  1. Johnson Controls Standalone BAS Sensors (A99 / TE Series, not built-in chiller spare parts, for building automation)

These are Johnson Controls branded sensors, not YORK 025-series chiller OEM spares, used for BAS systems:

A99LY-200C, A99LY-300C: PTC duct & pipe temperature sensors

TE-6361A-1, TE-6361M-1: 10K Type II NTC duct probes

✅ Sourcing & Regole di sostituzione (Per Manutenzione)

  1. Interchangeability only when B-value matches: All variants of 025W29964 (000/001/002/004) are 3K NTC3855
  2. Many probes for YK/YV/YS are 10K NTC, not compatible with 3K YMC2 probes; direct installation will trigger faults
  3. Distinguish types: Water immersion probe (copper tube), refrigerant probe (high-pressure resistant package), oil temperature probe (oil-resistant package). Similar appearance but different pressure and medium resistance
  4. Complete OEM kit: 325-29964-604 (YK water side full sensor kit including 4 pcs 025W29964-002)

📌 Supplementary Notes

Full YORK spare parts database is available in HVAC Navigator, the correct probe can be locked by unit serial number

The above list covers high-volume models commonly seen on site, not the complete Johnson Controls part library

Se necessario, I can export separate data: NTC resistance (R25), B-value, Steinhart-Hart coefficients and HS code for each part number

Campi applicabili (For 3K@25°C, B=3855, YORK 025W29964-000 YMC2 NTC)

Prerequisito: This resistance-temperature table is only valid for NTC with R25=3kΩ and B-value=3855K. Not applicable for NTC with different B-values.

  1. HVAC & Refrigerazione (Primary Original Application)

Maintenance and testing of YORK YMC2 magnetic bearing centrifugal chillers, YK/YV centrifugal chillers

On-site multimeter comparison to check open circuit, cortocircuito, resistance drift and aging

Calibration for chilled water, cooling water, VSD temperature and freeze protection loops

Chiller retrofit, alternative sensor selection and incoming inspection of replacement probes

Troubleshooting and commissioning for building cooling stations and central air conditioning control cabinets

  1. Automazione industriale & PLC Programming

PLC (Siemens, Mitsubishi, Allen‑Bradley etc.) analog acquisition and NTC temperature conversion programming

Curve lookup calibration for temperature controllers and custom replacement mainboards

Temperature conversion logic for SCADA and HMI (lookup table method reduces computing load vs real-time exponential calculation)

Nota: The original controller uses Steinhart-Hart equation. This B-value table is for simple acquisition and maintenance reference only. Not recommended for high-precision chiller firmware

  1. Spare Parts Foreign Trade, Appalti & Ispezione di qualità (Ideal for your industrial spare parts website)

Technical specifications, datasheets, quality inspection notes and SEO knowledge base content for product pages

Incoming quality control for suppliers: sampling inspection of NTC resistance

Technical reference for overseas clients and maintenance subcontractors

Attachment for alternative sensor datasheets and technical agreements

  1. Laboratorio, Metrology & Incoming Testing

Fast screening of NTC thermistor samples and preliminary failure judgement

Comparative test with constant temperature bath to preliminarily verify B-value 3855

Nota: Not for official metrology certification. Formal calibration requires certified calibration reports

  1. Other Equipment Compatible with 3K3855 NTC (Non-YORK Units)

Many industrial temperature control devices adopt the same NTC specification:

Industrial chillers, oil chillers, laser cooling units and spindle cooling systems

Battery cooling systems and thermal management (some older BMS)

Mold temperature controllers and small industrial heat pumps

⚠️ Important reminder: Most new energy storage NTCs are 10K, 5K or 10K3950, this table cannot be used

❌ Scenari non idonei

  1. High-precision metrology, third-party certification and factory calibration (Steinhart-Hart coefficients + multi-point calibration required)
  2. Other NTC specifications: 10K3950, 5K, 20K, PTC, PT100/PT1000 RTD
  3. Safety interlock and freeze protection firmware development (YORK mainboard uses Steinhart-Hart; B-value table brings deviation at low temperature and may cause false alarms)
  4. Medical equipment and precision laboratory instruments requiring ultra-high accuracy

On-site maintenance, prova del multimetro, incoming QC, simple PLC programming and spare parts documentation → B-value resistance-temperature table can be used

Chiller mainboard firmware, high-precision acquisition and OEM-level replacement development → Steinhart-Hart coefficients are preferred

Industrie applicabili (For 3K@25°C B3855 NTC, YORK 025W29964-000 R-T Table)

Prerequisito: Only valid for NTC thermistor with R25=3kΩ and B-value=3855K. Not applicable for other NTC specifications.

  1. HVAC & Industria della refrigerazione (Native Application)

Maintenance of centrifugal chillers, magnetic bearing chillers, screw chillers, industrial chillers, oil chillers, heat pumps and cooling stations; service troubleshooting, incoming inspection of spare parts, validation of alternative probes and freeze protection commissioning. Same NTC specification widely adopted by YORK, Johnson Controlli, Trane, McQuay and other large water-cooled chiller OEMs and after-sales service.

  1. Industrial Automation Industry

PLC, termoregolatori, custom control boards, SCADA and HMI programming; equipment thermal retrofit, control cabinet integration and temperature acquisition logic debugging; cooling water, hydraulic oil and lube oil temperature monitoring.

  1. Industrial Spare Parts Trading & Import/Export Industry

Datasheets, documenti tecnici, pre-sales technical support, maintenance reference for overseas clients and incoming QC standards. Suitable for foreign trade websites, spare parts distributors and engineering subcontractors.

  1. Laser Equipment Industry

Laser chillers, laser spindle cooling and fiber laser cooling units; many water cooling systems adopt 3K3855 NTC.

  1. Mold Temperature Control Industry

Water and oil mold temperature machines, water side temperature monitoring and over-temperature protection loop testing.

  1. Stoccaggio dell'energia & Battery Thermal Management Industry (Selected Legacy Models)

Battery cooling plate and liquid cooling thermal loops (only older BMS versions; most new designs use 10K3950, verify parameters before selection).

  1. Macchina utensile & Spindle Industry

CNC spindle water cooling, hydraulic station cooling system temperature monitoring and oil over-temperature protection.

  1. Confezione & Industria della plastica

Chillers for extruders and injection molding machines, cooling loop temperature verification.

  1. Metrology Testing (Rough Screening, Not Legal Metrology)

Fast screening of NTC components by manufacturers and third-party labs; for engineering reference only, not for metrology certification reports.

❌ Industries & Scenarios Where This Table Is Not Suitable

Medical devices and precision instruments (require high accuracy calibration with Steinhart-Hart coefficients)

Mainstream new energy BMS and charging piles (mostly 10K3950)

Food sterilization, precision cold chain verification and laboratory metrology calibration

Equipment using PT100/PT1000 RTD and PTC sensors

Prec:

Lascia una risposta