Siemens 6EP1437-2BA10 SITOP POWER 40 Trifase Industrial Power Supply
- Scomposizione del codice modello
6EP1437-2BA10
6EP: Standard industrial power supply series of SITOP
1437: High-power three-phase AC model, 40A output platform
2: Basic standard version (without redundant diagnostic interface)
BA: Montaggio su guida DIN, 24Uscita VCC
10: 3-phase 400–500V input, 40UN / 960W output specification
- Parametri elettrici principali
Lato ingresso (3-Phase Industrial Grid)
Input format: 3×400~500V AC, 3-phase 5-wire L1/L2/L3/PE
Frequenza: 50/60Hz
Voltage dip tolerance: Minimum 340V for 2 seconds without output collapse
Wire gauge for input terminals: 0.5~4mm² solid/stranded copper wire
Output Side (Standard Industrial 24VDC)
Potenza nominale: 24VCC / 40UN, total power 960W
Adjustable output voltage range: 22.8~26.4V (tweaked via potentiometer at bottom)
Ripple & rumore: Ripple <150mVpp, peak noise <240mVpp
Output terminals: Dual groups of +/terminals for parallel connection; wire gauge 0.5~10mm²
Parallel expansion: Two identical units can be directly paralleled for max. 80Un'uscita
Funzioni di protezione (Full-condition Protection)
- Protezione da cortocircuito: Automatic hiccup current limiting, auto-recovery after fault clearance
- Protezione da sovratensione (OVP): Output cut-off when voltage >27V
- Protezione da sovraccarico (OLP): Current limiting at 120% corrente nominale
- Over-temperature Protection (OTP): Shutdown on overheat, auto-restart after cooling down
- Protection against input phase loss, surge and industrial EMC interference
III. Meccanico & Specifiche ambientali
Montaggio: Vertical installation on standard 35mm DIN rail
Dimensioni complessive (L × A × P): 160 × 125 × 121 mm
Peso netto: ca. 2.0 kg
Classe di protezione: IP20 (for cabinet installation only)
Temperatura operativa: 0~+55°C (full power derating required above 55°C)
Magazzinaggio / transport temperature: -25℃~+85℃
Umidità: 5%~95%RH, nessuna condensa
Certificazioni: CE, UL, GL marine certification; compliant with EN61010, EN61000 industrial EMC standards
- Comparison Table of Same-Series 3-Phase Power Supplies
| Ordine n. | Ingresso | 24V Output | Energia | Posizionamento |
| 6EP1436-2BA10 | 3AC 400–500V | 20UN | 480W | Medium-capacity 3-phase power supply |
| 6EP1437-2BA10 | 3AC 400–500V | 40UN | 960W | High-power standard 3-phase power supply |
| 6EP1437-3BA00 | 3AC 400–500V | 40UN | 960W | Equipped with relay signal output (fault contacts 13/14) |
- Definizione del terminale
- Input terminals: L1, L2, L3, PE (3 fasi + protective earth)
- Output terminals: Dual sets of +24V, 0V (parallel for current sharing)
- Voltage trimming potentiometer: Located at bottom; adjust with flat screwdriver
- Indicatore luminoso: Solid green = normal output; spento / flashing = fault (perdita di fase, cortocircuito, surriscaldamento)
- Scenari applicativi tipici
- Large PLC control cabinets (S7-1500/400, full-station power supply for ET200SP distributed I/O)
- Multi-axis servo systems, inverter control stations, postazioni di lavoro robotizzate
- Confezione, logistics sorting, automotive welding & assembly production lines
- Trattamento dell'acqua, energia eolica, metallurgia, cement and other high-power industrial control equipment
- Centralized 24V power supply scenarios requiring 3-phase industrial incoming power and high current loads
VII. Sostituzione & Capacity Expansion Solutions
- Upgraded same-spec model: 6EP1437-3BA00 (with fault relay contacts for PLC diagnostic connection)
- Capacity expansion: Parallel two 6EP1437-2BA10 units for max. 80UN / 1920W output
- Downsized alternative: 6EP1436-2BA10 (20UN / 480W) for half-load applications
VIII. Installation Prohibitions & Guida alla risoluzione dei problemi
Forbidden Operations (Critical Restrictions)
- Horizontal or upside-down mounting is strictly prohibited; blocked cooling air duct triggers rapid over-temperature protection
- Long-term power-on with direct output short circuit will cause continuous hiccup power derating
- Long-term operation with missing input phase accelerates aging of internal power components
- Do not install alongside high-power inverters without partition plates to avoid EMC interference
Common Fault Matrix
| Fenomeno | Causa ultima | Countermeasures |
| Green light off, no 24V output | 3-phase power loss, l'interruttore è scattato, internal overheating | Check 3-phase incoming voltage; power off and cool down then restart; clean dust in air duct |
| Green light flashing, output voltage drop | Output overload / cortocircuito | Disconnect loads and locate short circuit by segmentation; limit total load within 40A |
| Output voltage below 23V under load | Undersized cables causing excessive voltage drop | Thicken 24V main cables; add auxiliary power supplies nearby |
| Frequent over-temperature shutdown | Ambient temp >55℃, clogged air duct, fully enclosed cabinet | Install cabinet cooling fan, lower ambient temperature, reserve ≥50mm top & bottom ventilation clearance |
Official Overall Dimensions of Siemens 6EP1437-2BA10 (SITOP POWER 40 3-Phase 40A Power Supply)
- Overall Unit Dimensions (L × A × P, unità: mm)
160 × 125 × 121 mm
Larghezza (horizontal along DIN rail): 160 mm
Altezza (vertical cooling air flow direction): 125 mm
Profondità (cabinet depth direction): 121 mm
Peso netto: ca. 2.0 kg
- Dimension Differentiation of Confusable Same-Series Models (Avoid Errors in Procurement & Cabinet Layout)
| Ordine n. | Specifica | L × A × P (mm) | Peso |
| 6EP1436-2BA10 | 3-phase 20A | 90 × 125 × 120 | 1.6 kg |
| 6EP1437-2BA10 | 3-phase 40A (without fault contacts) | 160 × 125 × 121 | 2.0 kg |
| 6EP1437-3BA00 | 3-phase 40A (with fault relay) | 160 × 125 × 121 | 2.0 kg |
| 6EP1437-2BA20 (New PSU300S Series) | New generation 40A | 145 × 145 × 150 | 3.1 kg |
- Cabinet Installation Clearance Requirements
- Binario di montaggio: Standard 35mm TH35 DIN rail, installazione verticale (terminals downward)
- Superiore & bottom ventilation clearance: Reserve at least 40mm for heat dissipation; derating mandatory if ambient temp exceeds 55℃
- Side-by-side mounting: Units of same model can be tightly arranged without extra spacing
Nota integrativa
Dimensions such as 250×180×92 and 145×145×150 shown on some foreign websites belong to the new PSU300S model 6EP1437-2BA20, which is incompatible with the legacy 6EP1437-2BA10. Cabinet cutout and DIN rail layout cannot be shared between them.
Contattore,interruttore automatico,inverter solare,contatore elettrico,batterie solari