カルロ・ガヴァッツィ VNY 4 NS/NT Conductive Level Sensor (Item No.: 481046)

カルロ・ガヴァッツィ VNY 4 NS/NT Conductive Level Sensor (Item No.: 481046)

モデルセグメント説明
VNY製品シリーズ: Conductive level probe; VNY series features threaded connection with PBTP housing and non-insulated electrodes
4Electrode quantity: 4 electrodes, supporting multi-level monitoring (高い / 中くらい / 低い / Ultra-low)
NSElectrode type: Non-Isolated, suitable for general conductive liquid measurement
NT接続タイプ: ネジ端子, convenient for field wiring
481046Global unique item / 注文番号, official Carlo Gavazzi part identifier
  1. Full Core Technical Specifications
パラメータのカテゴリ仕様備考
Basic InfoConductive level sensor for multi-point level control of conductive liquidsMust be used with amplifier relays (SV series, S195/196, ELA/ELC/ELD)
注文番号.481046 (corresponds to model VNY 4 NS/NT)Order strictly by this part number
メーカーカルロ・ガヴァッツィWell-known brand in industrial automation sensors
Electrode Configuration4 non-insulated electrodes, AISI316 stainless steel (DIN1.4401)Diameter 5mm, standard length 100cm (field-cuttable)
ハウジング材質PBTP engineering plasticCorrosion-resistant for industrial environments
取付タイプ1 1/2″ pipe thread (ISO 228/1-G1 1/2″)Standard industrial pipeline mounting, fixed with VM15 nut
接続方法Screw terminal connection (NT)More suitable for vibrating environments than cable connection, easy maintenance
侵入保護IP67Dust-tight and waterproof, submersible in liquid
動作温度0°C ~ 90°C (32°F ~ 194°F)Compatible with most industrial liquid temperature ranges
保管温度-25°C ~ 100°C (-13°F ~ 212°F)Adaptable to extreme transportation and storage conditions
使用圧力10 バー (@ 60°C)Suitable for medium and high-pressure tank applications
ケーブル仕様No built-in cable (screw terminal type)Customer-supplied cable recommended; shielded cable preferred to reduce interference
認証CE certified (IECに準拠 529)Meets EU industrial safety requirements
寸法Electrode diameter 5mm, total length approx. 100cmElectrode length can be cut on-site according to actual liquid level
重さ約. 0.8kgLightweight design for easy installation and maintenance
  1. VNY Series Full Model List
Item No.モデルElectrode QtyElectrode Type接続タイプハウジング材質Mounting Thread特別な機能
481046VNY 4 NS/NT4Non-Isolated (NS)ネジ端子 (NT)PBTP1 1/2″Multi-level control, general industrial use
481043VNY 1 NS/NT1Non-Isolated (NS)ネジ端子 (NT)PBTP1 1/2″Single-point level detection, 費用対効果の高い
481044VNY 2 NS/NT2Non-Isolated (NS)ネジ端子 (NT)PBTP1 1/2″Two-point high/low level control
481045VNY 3 NS/NT3Non-Isolated (NS)ネジ端子 (NT)PBTP1 1/2″Three-point high/medium/low level control
481047VNYI 4 IS/NT4Insulated (IS)ネジ端子 (NT)PBTP1 1/2″PE insulated electrodes, anti-clinging liquid interference
481042VNY 1 NS/CB1Non-Isolated (NS)Cable Connection (CB)PBTP1 1/2″2m fixed cable length, suitable for long-distance installation
  1. 交換 & Cross Reference

4.1 Same Brand Direct Replacement

オリジナルモデル代替機種Replacement Descriptionアプリケーションシナリオ
VNY 4 NS/NT (481046)VNYI 4 IS/NTUpgraded insulated electrodes to avoid false triggering from liquid clingingViscous liquids and wall-adhering media (syrup, lubricating oil)
VNY 4 NS/NT (481046)VNY 4 NS/CBChanged to cable connection for heavy vibration environmentsLevel monitoring for vibrating equipment such as pump sets and compressors
VNY 4 NS/NT (481046)VN 4 NS/CBCable type with PBTP housing and 1 1/2″ 糸General industrial environments, better cost performance

4.2 Cross-Brand Equivalent Models

カルロ・ガヴァッツィシュナイダーオムロンペッパール+フックス主な違い
VNY 4 NS/NT (481046)XPSAK3711D4CC-4000FTL20-0020Carlo Gavazzi adopts superior AISI316 material with IP67 protection
Schneider higher integration; Omron more cost-competitive
Field-cuttable electrode length for better adaptability
Pepperl+Fuchs suitable for explosion-proof areas; Carlo Gavazzi for general industry
  1. Application Industries & Typical Cases

推奨アプリケーション

  1. Process Industry: Tank level monitoring in chemical, petrochemical and pharmaceutical industries to prevent overflow and dry running
  2. 食べ物 & 飲料: Raw material and finished tank level control for beer, beverage and dairy production lines
  3. 水処理: Level monitoring for sedimentation tanks and reaction tanks in waterworks and wastewater plants
  4. Energy Sector: Level protection for cooling and lubrication systems in power plants and substations
  5. Mechanical Manufacturing: Oil level monitoring for hydraulic and lubrication systems to avoid equipment damage
  6. Marine Industry: Level measurement for ship ballast tanks, fuel tanks and fresh water tanks

 

Typical Application Cases

  1. Chemical Plant Acid & Alkali Tank Level Control System

Application Goal: Monitor high/low levels of three 100m³ acid and alkali tanks to prevent overflow and pump dry running

主な利点: AISI316 corrosion-resistant electrodes; IP67 suitable for outdoor installation; 4-electrode enables multi-point level monitoring

System Configuration: VNY 4 NS/NT (481046) × 3 + ELA amplifier relay + PLC control system + HMI touch screen

Operation Effect: Level control accuracy ±1cm, false alarm rate reduced by 95%, maintenance cost cut by 60%

 

  1. Automobile Factory Hydraulic Station Oil Level Monitoring System

Application Goal: Monitor oil levels of 5 hydraulic stations to ensure stable operation and prevent oil shortage failure

主な利点: Vibration-resistant screw terminal design; oil-resistant PBTP housing; field-cuttable electrodes adaptable to various tank heights

System Configuration: VNY 4 NS/NT (481046) × 5 + S196 amplifier + indicator light + buzzer

Operation Effect: Equipment failure rate reduced by 40%, maintenance cycle doubled

Not Recommended Applications

Non-conductive liquids: Such as pure oil, alcohol, acetone; not detectable by conductive sensors

High temperature >90℃: Adopt VPP series (up to 100°C) or high-temperature versions

使用圧力 >10 バー: Special high-pressure level sensor required

Strong corrosive media: Concentrated hydrochloric acid, concentrated sulfuric acid; use VPP series with PVDF electrodes or anti-corrosion coated models

  1. インストール & Wiring Guidelines

インストール要件

  1. 取付位置: Install on tank top or side, away from inlet ports and agitators; ensure vertical electrode immersion
  2. Electrode Cutting: Cut electrode length on-site according to actual liquid level; deburr the end after cutting for accuracy
  3. Sealing: Use suitable gaskets (PTFE recommended) for leak-tight installation to maintain IP67 protection
  4. Earthing Requirement: Conductive tank body can serve as common electrode; non-conductive tanks require separate common electrode grounding
  5. Spacing Requirement: Keep ≥50mm between electrodes and between electrodes and tank wall to avoid signal interference

Core Terminal Definition

端子番号.関数タイプ備考
E1/E2/E3/E4Electrode 1–4Signal InputCorrespond to four level detection points; freely assign high/medium/low functions
COMCommon TerminalSignal ReferenceConnect to tank wall or separate common electrode to complete circuit
+V/-V電源24VDCRequires matching amplifier relay; sensor itself needs no independent power supply
NO/NC/COMリレー出力Switch ContactProvided by amplifier relay for valve control or alarm output

コミッショニングの重要なポイント

  1. Electrode Setting: Define corresponding level heights for each electrode (例えば. E1=Low, E2=Medium, E3=High, E4=Ultra-high)
  2. Sensitivity Adjustment: Adjust amplifier relay sensitivity to avoid false triggering caused by foam or clinging liquid
  3. 機能テスト: Simulate level changes to verify accurate switching action and response time
  4. Insulation Check: For non-insulated type, ensure no short circuit between electrodes and tank wall; check insulation integrity for insulated type
  5. Environmental Adaptation Test: Verify long-term stability within rated temperature and pressure range
  6. Selection Rules & Quick Reference

選定ガイドライン

  1. Liquid Type: Choose VNY series for conductive liquids; use capacitive or ultrasonic sensors for non-conductive liquids
  2. Electrode Quantity: 1=single point, 2=high/low, 3=high/medium/low, 4=four-point full control
  3. Electrode Insulation: NS for normal liquids; IS insulated type for viscous wall-adhering media
  4. 接続タイプ: NT screw terminal for vibration environments; CB cable type for long-distance installation
  5. Mounting Thread: 1 1/2″ for large tanks, 1″ for medium, 1/2″ for small containers
  6. 温度 & プレッシャー: VNY for 0–90°C / 10 バー; VPP for higher temperature; special models for higher pressure
  7. Air Freight Compliance & 認証

Air Freight Compliance: No lithium battery / supercapacitor. Pure mechanical and metallic structure, compliant with IATA DGR Class 9, shippable as standard general cargo.

認証:

– CE: IEC準拠 529 ingress protection standard

– RoHS: EU RoHS compliant, free of hazardous heavy metals

Material Certification: AISI316 stainless steel electrodes meet food-contact grade requirements for food & beverage industry

Environmental Compliance: Compliant with REACH regulations for global market access

  1. 購入 & Logistics Information
Purchase Item詳細
MOQ1 unit
リードタイムStandard 5–7 days; Express 2–3 days
包装Individual carton with installation manual, sealing gasket and mounting nut
保証12 months from commissioning acceptance
Recommended SparesSame model sensor, electrode extension joint (VD1), mounting nut (VM15)
マッチングアクセサリーCarlo Gavazzi ELA/ELC/ELD amplifier relay, PLC, HMI touch screen