ABB XT2N160 TMA 160 3p F F

Order No.: 1SDA061805R1 (1SDA067020R1)

Full Model: XT2N 160 TMA 160-1600 3p F F

シリーズ: ABB Tmax XT Series Molded Case Circuit Breaker

  1. Core Parameters Summary
Parameter Category詳細仕様注意事項
Basic Information• Frame size: XT2For low-voltage power distribution in industry and buildings
• Frame current: 160あ
• Rated current In: 160あ
• Poles: 3P
• Breaking capacity: タイプN (36kA @ 415V AC)
• Rated operating voltage Ue: 690Vと, 500V DC
• Standards: IEC 60947-2, GB 14048.2
Trip System• Trip type: TMA thermal-magnetic (過負荷 + 短絡保護)Not suitable for earth fault protection; additional accessories required
• Overload protection (Ir): Adjustable, 160あ
• Short-circuit protection (I3): Adjustable, 800~1600A
• Instantaneous short-circuit protection: Fixed at 10In (1600あ)
• Protection curve: Complies with IEC 60947-2
Mounting & 繋がり• Mounting type: Fixed (F)Standard DIN rail or screw mounting
• Connection: Front connection (F)
• Operation: Direct handle operation
• Dimensions: 90mm×130mm×82.5mm
• Weight: 約. 1.574kg
• Protection degree: IP20
Electrical Characteristics• Rated insulation voltage Ui: 800VSuitable for AC-1, AC-2, AC-3, AC-4 duties
• Rated impulse withstand voltage Uimp: 8kV
• Rated short-time withstand current Icw: 16kA/1s
• Rated frequency: 50/60Hz
• Wiring capacity: max. 95mm² copper, max. 70mm² aluminum
  1. Detailed Protection Characteristics

2.1 過負荷保護 (Thermal)

Characteristic: Inverse time curve per IEC 60947-2

Adjustable range: 160あ (fixed)

Trip time:

1.05で: No trip for long duration

1.3で: Trip within ≤1 hour

6で: Trip within 2~10 seconds

2.2 短絡保護 (Magnetic)

Instantaneous trip: 800~1600A adjustable (I3)

Short-time delay: 利用不可 (TMA has no short-time delay; TMD or electronic trip required)

Instantaneous short-circuit protection: Fixed at 10In (1600あ), non-adjustable

  1. Mounting Dimensions & 身体的特徴
Dimension価値Unit
Width90mm
Height130mm
Depth82.5mm
Mounting hole spacing75mm
Terminal spacingStandardmm
重さ1.574kg
Package size145*130*208mm
Package weight1.2kg

Mounting Requirements:

35mm standard DIN rail (EN 60715) recommended

Ambient temperature: -25°C ~ +70°C

高度: ≤2000m (derating required above)

Protection: IP20 (front); must be installed in enclosure with IP30 or higher

  1. Replacement & Extended Models in the Same Series

4.1 Direct Replacement Models

モデルDifferenceApplication
XT2N160 TMA 160 3P F FIdentical specificationsDirect replacement, no modification needed
XT2N160 TMA 160 3P P FPlug-in mounting (P)Frequent replacement or maintenance
XT2N160 TMA 160 3P F WRear connection (W)Limited cabinet space

4.2 Function-Extended Models

モデルFunctional UpgradeOrder No.
XT2N160 Ekip LSI 160 3P F FElectronic trip, LSI protection1SDA067071R1
XT2N160 Ekip LSIG 160 3P F FElectronic trip, LSIG protection (including earth fault)1SDA067072R1
XT2N160 TMD 160 3P F FThermal-magnetic with short-time delay1SDA067035R1

4.3 Pole-Extended Models

4P version: XT2N160 TMA 160 4p F F (Order No.: 1SDA061806R1 / 1SDA067041R1)

Neutral pole rated current: 50% または 100% of phase current optional

4.4 Cross-Brand Reference

シュナイダー: NSX160N TMD160 3P F

シーメンス: 3VT8116-1AA03-0AA0

チント: NM1-160S/3300 160A

  1. Recommended Accessories
Accessory TypeモデルDescription
Auxiliary contactXT2-AS111いいえ + 1ノースカロライナ州, for status indication
Alarm contactXT2-AL111いいえ + 1ノースカロライナ州, for fault alarm
Shunt tripXT2-SHTRemote tripping, AC/DC 220V
Undervoltage releaseXT2-UVTUndervoltage protection, AC 220V
Rotary handleXT2-CRDoor-mounted operation, improved safety
Extended rotary handleXT2-CREFor deep panels
Terminal coverXT2-TCProtect terminals, prevent electric shock
Label holderXT2-LBFor marking breaker parameters
  1. Applications & Selection Notes

6.1 代表的な用途

Industrial plants: Motor protection (≤160A), distribution feeder protection

Commercial buildings: HVAC, lighting, pump control

Infrastructure: Small substations, データセンター, PV systems

Others: OEM equipment, agricultural machinery, marine systems

6.2 Selection Guide

Requirement推奨Not Recommended
Motor protection (with proper setting)Small motors (<10あ); use MCB instead
Distribution protection (sub-circuits)Main incomer (use XT3/XT4 series)
Earth fault protection (needs accessories) (choose Ekip LSIG)
Frequent operation (MCCB not suitable) (接触器 + relay)
Isolation function (IEC 60947-3)

6.3 Selection Cautions

  1. Ensure rated current In matches load
  2. Breaking capacity must meet system short-circuit current (N: 36kA @ 415V)
  3. Mounting (fixed/plug-in) and connection (front/rear) must match panel design
  4. Auxiliaries, shunt/undervoltage trips ordered separately
  5. Not for DC short-circuit protection (use DC-rated model)
  6. トラブルシューティング & メンテナンス

7.1 一般的な障害 & ソリューション

Symptom考えられる原因ソリューション
Frequent tripping1. Overload1. Check load
2. Short circuit2. Locate short circuit
3. Incorrect trip setting3. Reset settings
4. 周囲温度が高い4. Improve ventilation
Cannot close1. No power to undervoltage trip1. Check control power
2. Shunt trip not reset2. Reset shunt trip
3. Mechanism fault3. Contact ABB service
4. Line fault4. Clear fault
No output after closing1. Main contacts damaged1. Inspect/replace contacts
2. 配線の緩み2. Tighten terminals
3. Trip unit fault3. Replace trip unit
Aux contact no signal1. Auxiliary contact defective1. Replace auxiliary contact
2. Wrong wiring2. Check wiring
3. Improper switching3. Adjust contact position

7.2 Maintenance Recommendations

Inspection: Every 6 months – check wiring and mechanism

Cleaning: Every 12 months – remove dust to maintain insulation

Operation test: Once per year – 3~5 manual ON/OFF cycles

Trip test: Once every 2 years – simulate overload and short circuit

Service life: Typically 10 years, depending on duty and environment

  1. Ordering & Packaging

Standard package: 1 unit/box, including installation manual and certificate

MOQ: 1 unit

Warranty: 18 months from commissioning, または 24 months from delivery (whichever comes first)

Order code: 1SDA061805R1 (or 1SDA067020R1, varies by region)

Complete Model Guide for ABB Tmax XT2 Series (160A Frame)

Frame size: XT2 (160あ)

定格電圧: 690Vと, 500V DC

Poles: 3P / 4P

Breaking classes: N(36の), S(50の), H(70の), L(100の)

  1. Model Naming Convention

XT2 [Breaking Class] [Frame Current] [Trip Type] [Current Range] [Poles] [Mounting] [繋がり]

Breaking class:

N: 36kA @ 415V (標準)

S: 50kA @ 415V (enhanced)

H: 70kA @ 415V (high performance)

L: 100kA @ 415V (ultimate)

Frame current: 160 (fixed)

Trip type:

TMA: Thermal-magnetic (過負荷 + instantaneous, no short-time delay)

TMD: Thermal-magnetic (過負荷 + short-time delay + instantaneous)

Ekip LSI: Electronic (過負荷 + short-time delay + instantaneous)

Ekip LSIG: Electronic (過負荷 + short-time delay + instantaneous + earth fault)

Ekip I: Electronic (instantaneous only)

Current range: 例えば, 160-1600 (TMA 160A)

Poles: 3P / 4P

Mounting: F (Fixed) / P (Plug-in)

繋がり: F (Front) / W (Rear)

  1. XT2 Series Model List (by Breaking Class)

2.1 Standard Breaking (N, 36の)

Model PrefixTrip Type代表的なモデルCurrent RangeApplication
XT2N160TMAXT2N160 TMA 160-1600 3P F F160あGeneral distribution, モーター
TMDXT2N160 TMD 100-1000 4P F W100あSystems requiring short-time delay
Ekip LSIXT2N160 Ekip LSI R125 3P P F125あElectronic protection, remote monitoring
Ekip LSIGXT2N160 Ekip LSIG R80 4P F F80あEarth fault protection required

Example Order No.: 1SDA061805R1 (XT2N160 TMA 160 3P F F)

2.2 Enhanced Breaking (S, 50の)

Model PrefixTrip Type代表的なモデルCurrent RangeApplication
XT2S160TMAXT2S160 TMA 63-630 3P F F63あIndustry, heavy-duty equipment
TMDXT2S160 TMD 40-400 4P P W40あFrequently started motors
Ekip LSIXT2S160 Ekip C Dip LSI R100 3P F F100あComplex commercial distribution
Ekip LSIGXT2S160 Ekip LSIG R50 4P F F50あData centers, medical facilities

Example Order No.: 1SDA067021R1 (XT2S160 TMA 160 3P F F)

2.3 High Performance Breaking (H, 70の)

Model PrefixTrip Type代表的なモデルCurrent RangeApplication
XT2H160TMAXT2H160 TMA 32-320 3P F F32あIndustrial systems with high short-circuit current
TMDXT2H160 TMD 3.2-32 4P F F3.2あPrecision equipment, control circuits
Ekip LSIXT2H160 Ekip Dip LSI R63 3P P F63あGenerators, substations
Ekip LSIGXT2H160 Ekip LSIG R25 4P F F25あPV, renewable energy

Example Order No.: 1SDA067587R1 (XT2H160 TMD 3.2-32 3P F F)

2.4 Ultimate Breaking (L, 100の)

Model PrefixTrip Type代表的なモデルCurrent RangeApplication
XT2L160TMAXT2L160 TMA 100-1000 4P F F100あHeavy industry with very high fault level
TMDXT2L160 TMD 160-1600 3P F W160あLarge motor control centers
Ekip LSIXT2L160 Ekip LSI R160 3P P F160あMetallurgy, chemical, hazardous areas
Ekip LSIGXT2L160 Ekip LSIG R125 4P F F125あPetrochemical, mining

Example Order No.: 1SDA067667R1 (XT2L160 TMA 100-1000 4P F F)

  1. Trip Unit Comparison
Trip TypeProtectionAdjustable ParametersTypical LoadPrice Level
TMAOverload + InstantaneousIr, I3Motors, general distribution経済
TMDOverload + Short-time + InstantaneousIr, Isd, tsd, I3Transformers, capacitors中くらい
Ekip LSIOverload + Short-time + InstantaneousFull range, communicationCritical distributionMedium-High
Ekip LSIGOverload + Short-time + Instantaneous + Earth FaultFull range, communication, loggingSensitive loads, safety高い
Ekip IInstantaneous onlyI3Short-circuit intensive devices経済
  1. Special Models & Options

4.1 4P Neutral Configurations

Standard: Neutral = 50% phase (general distribution)

Heavy: Neutral = 100% phase (non-linear loads: VFD, UPS)

例: XT2N160 TMA 160 4P F F (100% neutral)

4.2 Plug-in Mounting (P)

Fast replacement, suitable for critical equipment

例: XT2S160 TMD 80 3P P F

4.3 Rear Connection (W)

Saves cabinet space, compact panels

例: XT2H160 Ekip LSI R63 3P F W

4.4 アクセサリの互換性 (Full Series)

AccessoryモデルDescription
Auxiliary contactXT2-AS111NO+1NC, status indication
Alarm contactXT2-AL111NO+1NC, fault alarm
Shunt tripXT2-SHTRemote tripping, AC/DC 220V
Undervoltage releaseXT2-UVTUndervoltage protection, AC 220V
Rotary handleXT2-CRDoor operation, safety
  1. Quick Selection Table
ApplicationRecommended ClassTrip TypePolesMount/Conn
General industrialN/STMA/TMD3PF/F
Motor protectionN/STMA3PF/F
Commercial lightingNTMA3P/4PF/F
Data centerH/LEkip LSIG4PF/W
PV systemH/LEkip LSIG4PF/F
Frequent maintenanceAnyAny3P/4PP/F
  1. Replacement & Upgrade Path

6.1 Same-Frame Upgrade

遮断容量: XT2N → XT2S → XT2H → XT2L (dimensions unchanged)

Trip unit: TMA → TMD → Ekip LSI → Ekip LSIG

Mount/connection: F/F → P/F or F/W

6.2 Cross-Frame Upgrade

XT2 (160あ) → XT3 (250あ) → XT4 (250A enhanced) → XT5 (630あ)

Note dimension and parameter changes

All XT2 series models comply with IEC 60947-2 and GB 14048.2.

Fixed dimensions: 90mm × 130mm × 82.5mm for easy system expansion and maintenance.