The Chint NXB63-3P-D63 circuit breaker is a three-phase miniature circuit breaker (MCB) designed for high-load scenarios. It is suitable for circuits with an alternating current of 50/60Hz and a rated voltage of 400V AC, providing overload, short-circuit protection, and isolation functions. Below is an analysis of its core information: Core Parameters and FunctionsChint NXC-75/220V AC ...

  • 製品詳細

The Chint NXB63-3P-D63 サーキットブレーカー is a three-phase miniature circuit breaker (MCB) designed for high-load scenarios. It is suitable for circuits with an alternating current of 50/60Hz and a rated voltage of 400V AC, providing overload, short-circuit protection, and isolation functions. Below is an analysis of its core information:

  1. コアパラメータと関数Chint NXC-75/220V AC contactor
  2. Specification FeaturesChint DC Contactor NC1-5011-36V

Poles: 3P (three-phase), suitable for three-phase four-wire power distribution systems.

定格電流: 63あ, matching the continuous operation requirements of high-power equipment (例えば, モーター, 変圧器).

Trip Characteristic: Type D curve, with an instantaneous trip current of 10–16 times the rated current, effectively handling inrush currents during motor starting.

遮断容量: 6の, safely interrupting short-circuit fault currents to prevent contact welding or equipment damage.

  1. Technical Standards

Complies with IEC 60898-1 (international) および GB/T 10963.1 (中国) standards, and is 3C certified.

Operating temperature range: -35°C to 70°C, adapting to temperature fluctuations in industrial environments.

  1. アプリケーションシナリオ

Industrial Sector: Motor control, power distribution for production line equipment. The Type D trip characteristic avoids frequent false tripping.

Commercial and Residential Use: Main switches or branch protection in three-phase power supply systems, such as power distribution in shopping malls and factories.

Special Scenarios: Equipment requiring high short-circuit protection (例えば, welding machines, 変圧器), enabling rapid response to fault currents.

Ⅲ. Installation and Usage Recommendations

  1. インストール要件

Must be installed by a professional electrician, vertically mounted on a standard 35mm rail, ensuring wiring screws are tightened to prevent loosening and heat generation.

Use wires with appropriate cross-sectional area (例えば, 6mm² copper wire) and reserve sufficient operating space during wiring.

  1. Maintenance and Precautions

Regularly inspect contacts and terminal blocks to avoid poor contact due to oxidation or looseness.

If tripping occurs frequently, check whether the load exceeds the rated current or if a short-circuit fault exists.

  1. Price and Market Positioning

Reference Price: More cost-effective than similar imported brands (例えば, Siemens EA9 series).

Positioning: As an upgraded version of the DZ47 series, the NXB-63 improves breaking capacity and reliability, suitable for cost-sensitive scenarios requiring high protection performance.

  1. Comparison with Siemens Equivalent Products

遮断容量: The Siemens EA9AN3C63 has a breaking capacity of 6kA, comparable to the NXB-63, but its price is typically 30–50% higher.

Trip Characteristics: Siemens Type D curve products (例えば, 5SJ6 series) have an instantaneous trip multiple of 10–14 times, close to the NXB-63’s 10–16 times, both suitable for motor protection.

Certifications: Siemens products are usually UL-certified, while the NXB-63 does not explicitly mention North American certifications. U.S. users are advised to prioritize models with UL marks.

  1. 予防

Voltage Matching: The 3P model has a rated voltage of 400V AC and cannot be used in single-phase 230V circuits.

Certification Compliance: For use in the U.S., verify whether the product is UL-certified or choose other models compliant with North American standards (例えば, Siemens 5SJ6 series).

Technical Parameters of Chint NXB63-3P-D63 Circuit Breaker

(Compiled from official data and industry standards)

  1. Core Electrical Parameters
  2. 定格電圧: AC400V (three-phase system), suitable for 380V/400V power distribution scenarios; not for single-phase 230V circuits.
  3. 定格電流: 63あ, matching continuous operation of high-power equipment (例えば, モーター, 変圧器).
  4. Trip Characteristic: Type D curve, instantaneous trip current 10–16× rated current, effectively handling motor starting inrush currents.
  5. 遮断容量: 6の (IECに準拠 60898-1), safely interrupting short-circuit fault currents.
  6. 機械的パラメータと環境パラメータ
  7. Poles: 3P (three-phase), suitable for three-phase four-wire power distribution systems.
  8. Mechanical Life: 20,000 operations; Electrical Life: 10,000 operations, ensuring long-term stable operation.
  9. 動作温度: -35°C ~ +70°C, adapting to industrial temperature fluctuations.
  10. 設置方法: Standard 35mm rail mounting, requiring vertical fixation for heat dissipation and operational stability.

Ⅲ. Certifications and Compliance

  1. Domestic Certification: 3C certified (Certificate No. 2020980307001645), compliant with GB/T 10963.1.
  2. International Standards: Compliant with IEC 60898-1, but not explicitly UL-certified. North American users should prioritize models with UL marks (例えば, Siemens 5SJ6 series).
  3. Accessories and Extended Functions
  4. Auxiliary Contacts: Supports accessories like AX-X1 (1NO+1NC), MX+OF (shunt trip + auxiliary contact) for remote control and status feedback.
  5. Wiring Terminals: Threaded pressure plate terminals recommended for 6mm² copper wire (for 63A load), with a tightening torque of 2.0N·m to avoid heat generation.
  6. Dimensions and Installation Size

寸法: Approximately 90mm (W) × 75mm (H) × 85mm (D), subject to the official manual.

Wiring Space: Reserve sufficient space; recommended wire cross-sectional area: 1–25mm² (selected by load current).

  1. Notes
  2. Voltage Matching: Only for 400V three-phase systems; not for single-phase 230V circuits.
  3. 過負荷保護: Frequent tripping indicates checking whether the load exceeds the rated current or a short circuit exists.
  4. North American Market: Not UL-certified; recommend Siemens 5SJ6 or other North American-compliant models.