Chint NXBLE63 – 2P/C40

Chint NXBLE63 – 2P/C40 is a 2 – pole (2P) miniature residual current circuit breaker. Its main parameters and functions are as follows: Core Parameters Rated Current: 40あ (“C40indicates that the tripping characteristic is Type C and the rated current is 40A); 極数: 2P (cuts off both the live wire and the neutral wire ...

  • 製品詳細

Chint NXBLE63 – 2P/C40 is a 2 – pole (2P) miniature residual current circuit breaker. Its main parameters and functions are as follows:

Core Parameters

定格電流: 40あ (“C40indicates that the tripping characteristic is Type C and the rated current is 40A);

極数: 2P (cuts off both the live wire and the neutral wire simultaneously);

残留電流保護: AC type (detects ordinary AC leakage). The residual operating current is usually 30mA (an industry conventional value, and some models support options such as 50mA/75mA);

遮断容量: 6の (can safely cut off circuits with a shortcircuit current of not less than 6000A);

Applicable Voltage: 230V (for singlephase circuits);

Mechanical/Electrical Life: The mechanical life is 20,000 回, and the electrical life is 10,000 回.

Main Functions

  1. 残留電流保護: When there is electric shock to the human body (current ≥ 30mA) or equipment leakage in the circuit, the power supply is quickly cut off within 0.1 second to prevent electric shock casualties;
  2. 過負荷保護: If the circuit load is too large (current exceeds 40A), it will automatically disconnect to avoid overheating and fire of the circuit;
  3. 短い – 回路保護: 回路内でショートが発生した場合 (current increases sharply in an instant), the circuit is cut off immediately to protect electrical appliances and the circuit;
  4. アイソレーション機能: It can be used as a switch for infrequent onoff of the circuit under normal conditions.

アプリケーションシナリオ

Household Electricity: For highpower socket circuits in kitchens, living rooms, 等. (such as air conditioners, 電気温水器), it replaces traditional air switches and adds residual current protection;

Smallscale Commercial Places: For socket or lighting circuits in convenience stores and offices, meeting the electricity demand within 40A;

Decoration and Renovation: Upgrading the residual current protection of old circuits to meet the new national standard’s requirement thatsocket circuits must be equipped with residual current protection”.

Installation and Use Precautions

It should be selected according to the actual load of the circuit to avoida big horse pulling a small cart” または “a small horse pulling a big cart”;

Press thetest button (T key)” once a month to verify whether the residual current protection function is normal;

When installing, the live wire (L) and the neutral wire (N) must be distinguished. If the wiring is reversed, the residual current protection function may fail.