Eaton XTCG018C00AO Eaton-Moeller AC Contactor

注記: The last character is letter O, not digit 0; belongs to XTCG sub-series of Eaton XT-range IEC contactors. Model Code Decoding Code Segment Description XT Eaton XT‑range IEC control series C Contactor G XTCG series, screw‑terminated 3‑pole motor contactor 18 AC‑3 rated operational current:18A for main circuit C Frame size C, 45 mm width housing ...

  • 製品詳細

注記: The last character is letter O, not digit 0; belongs to XTCG sub-series of Eaton XT-range IEC 接触器.

モデルコードのデコード

コードセグメント説明
XTイートン XT‑range IEC control series
Cコンタクタ
GXTCG series, screw‑terminated 3‑pole motor contactor
18AC‑3 rated operational current:18A for main circuit
CFrame size C, 45 mm width housing
0No built‑in auxiliary contacts (0NO+0NC)
コイル: AC220V 50/60Hz (A=AC, O=code for 220VAC coil)

Full definition: 3-ポール, AC-3 18A, no-built-in auxiliary contacts, AC220Vコイル, screw-terminal AC contactor.

コアの電気パラメータ

アイテム仕様
Main Poles3P‑NO (three normally‑open main contacts)
AC‑3 Rated Operational Current18A @400V motor load
AC‑1 Resistive Load32あ
定格絶縁電圧 Ui690V
コイル電圧AC220V 50/60Hz
補助接点None onboard; external accessories XTCGXF*** required
機械的耐久性≥10 000 000 operations
AC‑3 Electrical Endurance≥1 000 000 operations
取り付けDIN35 rail mounting or screw‑on backplate mounting
端子ネジ締め端子
認証CCC, CE, UL, CSA, IEC60947‑4‑1

物理的な & 環境条件

Housing width: 45 mm

動作温度:-25℃~+60℃, condensation and icing forbidden

保管温度:-40℃~+85℃

重さ: 約. 0.21 kg

典型的なアプリケーションシナリオ

  1. Three-phase motor start-stop control (≤7.5kW @400V motor)
  2. ファン, ウォーターポンプ, コンベア, エアコンプレッサー, 包装機械
  3. 空調設備 & cabinet OEM assembly; can be paired with XTOD thermal overload relay for motor overload protection

List of Compatible Accessories

Auxiliary contact block: XTCGXFAC (1NO+1NC etc.), サイドマウント

サーマルリレー: XTOD018 (0.1-18A motor protection coverage)

Mechanical interlock module: XTCG-MV, for reversing circuit

サージキラー: ラジコン / varistor module for coil side

Direct-Replacement Models & 交換ノート

  1. Same-series alternative: XTCG018C00DT (different coil code; verify coil voltage, not a drop-in replacement)
  2. Cross-series alternative: XTCE018C00A0 (Eaton XTCE series, functionally equivalent; check accessory compatibility)

⚠️Pitfall reminder: XTCG018C00AO has no onboard auxiliary contacts. External auxiliary-contact accessory must be fitted if PLC feedback signals are required, otherwise control circuits cannot function.

Non-Applicable Operating Conditions

Switching frequency>1200 cycles/hour

Heavy corrosive gas / heavy dust environment without proper protection

DC-coil applications (this unit is AC-coil type)

Brief Wiring Instructions

  1. 主回路: L1-L2-L3 supply side; T1-T2-T3 load (モーター) 側
  2. Coil terminals A1/A2 connect to AC220V
  3. 補助接点は内蔵されていません; all logic feedback signals shall be obtained from externally fitted auxiliary-contact accessories.

XTCG018C00AO (Frame C) 取り付け & 全体の寸法 (ユニット: mm)

All XTCG-C frame models (009-032あ) share identical housing dimensions. Supports DIN35 rail mounting AND screw-on back-plate mounting.

全体の寸法 (without fitted accessories)

アイテム価値備考
Width W45Reference for cabinet layout spacing
Height H85Total height including upper & lower terminals
Depth D97.4Depth inside cabinet panel after rail‑mounted

Overall dimension: 45(W) × 85(H) × 97.4(D) mm

Screw-on back-plate cut-out dimensions (DIN rail unused, direct screw-fix onto cabinet back-plate)

Horizontal mounting-hole centre-to-centre spacing: 35 mm

Vertical mounting-hole centre-to-centre spacing: 76 mm

Fastener hole diameter: Φ4.5 (M4ネジ)

Hole-to-edge margin: approx.4.5 mm top & 底.

DIN Rail Installation Information

  1. Standard DIN-35-7.5 rail (universal electrical 35 mm rail)
  2. Back-side snap-in clip for direct rail-clip mounting; tool-free assembly & disassembly.

⚠️Dimension change after accessory installation

  1. Side-mount auxiliary-contact block XTCGXF: width increases by 10 mm, total width 55 mm
  2. Bottom-mount thermal overload relay XTOD: overall height increases by approx.42.5 mm
  3. Mechanical interlock XTCG-MV: two contactors side-by-side with zero gap; total width = direct sum (45+45=90 mm)

Installation Boundary Conditions

  1. Cooling clearance: ≥10 mm top & 底; no mandatory clearance side-to-side (multiple units may be mounted adjacent to each other)
  2. Do not mount tightly against closed cabinet partitions; ambient temperature-25℃~+60℃, condensation prohibited.
  3. Maximum permitted conductor size: main circuit 6 mm²; coil circuit 2.5 mm².

Cross-model reference

Models XTCG009C / XTCG025C / XTCG032C share identical housing, cut-out and rail-mount dimensions; only internal contact current rating differs. Varied coil voltage codes (AO/DT etc.) produce no change in physical dimensions.

Operating Voltage Differentiation for Eaton XTCG018C00AO

Two separate voltage systems exist for contactors: 主回路 (主な連絡先) and coil control circuit. Do not confuse them.

  1. コイル制御電圧 (suffix code AO)

Coil rated voltage: AC 220V 50/60Hz

端子: A1, A2

Permissible coil operating voltage range: 0.85~1.1×Ue, つまり. AC187V ~ AC242V

⚠️This is an AC coil. DC supply is strictly forbidden.

  1. 主回路 (main contacts for motor loads)
パラメータ価値
定格使用電圧Ueマックス. AC690V
Common operating voltagesAC230V / 400V / 500V / 690V
定格絶縁電圧Ui690V
Impulse withstand voltage Uimp6 kV

The 18A AC-3 rating is specified at 400V. Main circuit can operate within 0-690V AC; allowable current varies with applied voltage.

Key Supplementary Notes

  1. Suffix code `AO` exclusively denotes AC220V coil. Changing suffix code (例えば. DT=AC380V) only alters coil voltage; main-circuit voltage capability remains unchanged.
  2. Voltage outside permitted coil operating range causes faults: undervoltage → pull-in failure / chattering; overvoltage → coil overheating & burnout.
  3. Main-circuit current derating applies at elevated ambient temperatures.

XTCG018C00AO Coil Troubleshooting Guide

Coil specification: AC220V 50/60Hz; Terminals A1/A2; permissible operating range AC187V-242V; DC supply prohibited.

故障 1: Contactor does not pull-in at all, zero acoustic response

Probable Root-Causes

  1. No voltage on control circuit: 0V measured across A1/A2; upstream relay / PLC出力 / fuse / 壊れたワイヤー / loose terminal.
  2. Coil supply voltage below 0.85Ue (<187V): insufficient voltage for pull-in.
  3. Coil open-circuit burnout: infinite resistance reading between A1-A2 via multimeter.
  4. 機械的焼き付き: foreign-object ingress, corroded iron-core, mis-fitted add-on accessories causing mechanical jamming.

Remedial Steps

  1. Power-off safety confirmation; measure live voltage across A1/A2 terminals.
  2. 電源オフ; disconnect coil wiring; measure DC resistance of coil standalone. Typical resistance of C-frame AC220V coil: 1300-1500 Ω. Infinite resistance = burned-open coil; near-zero resistance = short-circuited coil.
  3. Manually actuate contactor armature; verify smooth movement. If sticking, remove foreign debris; inspect fit of auxiliary-contact / interlock accessories.
  4. Verify continuity of control-circuit fuse, PLC outputs and intermediate relays.

故障 2: Contactor chatters / loud buzzing noise, unstable pull-in

Probable Root-Causes

  1. Marginal low coil voltage; long-run / thin-gauge control wiring creates excessive voltage drop.
  2. Iron-core mating surfaces contaminated with oil, dust or iron-particles; enlarged magnetic air-gap.
  3. Supply-waveform distortion, harmonic distortion caused by VFD interference.
  4. Degraded coil with partial turn-to-turn short-circuit.

Remedial Steps

  1. Live measurement of A1/A2 voltage; must stay within AC187-242V. Increase control-cable cross-section for long-distance control loops.
  2. 電源オフ; clean iron-core mating surfaces of iron-dust and debris. Do NOT apply lubricant grease or oil.
  3. コイル抵抗を測定する; significantly-lower-than-nominal resistance indicates turn-to-turn short-circuit; replace full contactor unit.
  4. Fit RC-type coil surge suppressor in case of severe electromagnetic interference.

Fault3: Coil persistent overheating / rapid burnout

Probable Root-Causes

  1. Wrong supply voltage: AC380V applied to AC220V coil — most frequent burnout cause.
  2. Continuous supply voltage>1.1Ue (>242V), long-term over-voltage operation.
  3. Mechanical jamming prevents full armature closure; large residual air-gap keeps coil current high continuously.
  4. Accidental DC power supply to AC coil: instant burnout.

Remedial Steps

  1. Double-check actual supply voltage; match AO-coded AC220V coil rating strictly.
  2. Verify free mechanical movement; confirm full armature closure.
  3. Confirm AC-only supply; never drive with DC source.

Burnt-out coil: XTCG-series coils are non-field-replaceable individually. Replace complete contactor assembly.

Fault4: Contactor fails to release after de-energization (stuck closed)

Distinguish main-contact welding versus coil residual-voltage / mechanical-seizure non-release.

  1. Residual voltage persists across A1/A2 after coil de-energization (PLC leakage current, residual voltage from parallel indicator lamps).
  2. 機械的焼き付き; return-spring fatigue.
  3. Main-circuit short-circuit event resulting in welded main contacts.

Remedial Steps

  1. Measure residual voltage across de-energized A1/A2. Residual>30V prevents release; fit RC snubber for voltage dissipation.
  2. Disconnect main-circuit power; test manual return-action of mechanism. Replace unit if spring failure occurs.
  3. Inspect main-contacts for burn-welding. Welded contacts require full-unit replacement; do not refurbish by polishing contacts for continued service.

⚠️Hard-forbidden Operations

  1. Never apply DC voltage to AC220V AC-coil; instant burnout risk.
  2. Do not short-circuit terminals A1/A2 for test purposes.
  3. Do not repeatedly apply power to already-burned coil; secondary cabinet-damage risk.
  4. Never apply oil / grease onto iron-core mating surfaces; oil traps ferrous dust and causes buzzing / stuck-closed failure.

Quick-Reference Test Matrix

Measurement ItemAcceptable Reference ValueFault Judgment
Live coil operating voltageAC187‑242V<187V: pull‑in failure;>242V: overheating burnout
Coil DC resistance(A1‑A2)1300‑1500 ΩInfinite = open‑circuit; far‑lower reading = turn‑to‑turn short‑circuit
Residual voltage A1‑A2 (power‑off)<10 V>30 V risk of release failure

Supplementary note: No auxiliary contacts built-in. External side-mount auxiliary-contact block XTCGXF is mandatory for status feedback signals.