  Model Part Meaning ABE Series code, Meta-MEC economy MCCB, thermal-magnetic trip, low breaking capacity (economy type) 40 Frame rating current 400A 4 4 極 (4P), suitable for three-phase four-wire system protection B Breaking capacity class B (10kA@AC380V) 400A Rated operational current 400A, set by plug module Key Technical Parameters Item Specification Description Product Type ...

  • 製品詳細

 

Model Part意味
ABESeries code, Meta-MEC economy MCCB, thermal-magnetic trip, low breaking capacity (economy type)
40Frame rating current 400A
44 極 (4P), suitable for three-phase four-wire system protection
BBreaking capacity class B (10kA@AC380V)
400あRated operational current 400A, set by plug module
  1. Key Technical Parameters
ItemSpecificationDescription
Product Type経済 Molded Case Circuit Breaker (MCCB)Thermal-magnetic trip, fixed mount
定格電圧AC 600V, Ui 690VComplies with IEC 60947-2
Rated Frequency50/60HzUniversal frequency range
遮断容量Icu=10kA@AC380VClass B economy breaking capacity
Trip TypeFixed thermal-magnetic trip過負荷保護 (inverse time) + 短絡保護 (instantaneous)
定格絶縁電圧Ui=690VMaximum voltage for insulation performance
Mechanical Endurance8500 operationsStandard operating cycles
Electrical Endurance1000 operationsOperating cycles at rated current
Mounting TypeFixed typeStandard 35mm DIN rail or panel mount
繋がりFront connection / Rear connectionOptional for different installations
Applicable StandardsIEC 60947-1/2, で 60947-1/2International electrical standards
  1. Series Model List (400AF Frame)
モデル遮断容量定格電流範囲
ABE402b2P10の250あ, 300あ, 350あ, 400あ
ABE403b3P10の250あ, 300あ, 350あ, 400あ
ABE404b4P10の250あ, 300あ, 350あ, 400あ
ABS402b2P25の250あ, 300あ, 350あ, 400あ
ABS403b3P25の250あ, 300あ, 350あ, 400あ
ABS404b4P25の250あ, 300あ, 350あ, 400あ
ABH402b2P35の250あ, 300あ, 350あ, 400あ
ABH403b3P35の250あ, 300あ, 350あ, 400あ
ABH404b4P35の250あ, 300あ, 350あ, 400あ
  1. Recommended International Brand Replacements
ブランドシリーズReplacement Model主要なマッチングパラメータ
シュナイダーEZD SeriesEZD400E44004P, 400あ, 10の, thermal-magnetic trip
シーメンス3VT Series3VT8440-1AA034P, 400あ, 10の, thermal-magnetic trip
ABBTmax SeriesT2N400 TMD 400/400 FF 4P4P, 400あ, 10の, thermal-magnetic trip
EatonPower DefenseLZMN4-A400-I4P, 400あ, 10の, thermal-magnetic trip
Changshu SwitchCM3 SeriesCM3-400M/4300B 400A4P, 400あ, 10の, thermal-magnetic trip
  1. Applications & Selection Notes
  2. 代表的な用途

End protection in low-voltage distribution systems, 例えば, lighting and power distribution in commercial buildings and industrial plants

Three-phase asynchronous motor protection (≤200kW, 380V)

Capacitor bank protection

Small generator outlet protection

  1. Selection Guidelines

Confirm system voltage (≤600V) and frequency (50/60Hz)

Calculate circuit rated current to ensure 400A meets long‑term operation

Evaluate short-circuit level: if >10の, use higher breaking capacity ABS (25の) or ABH (35の) シリーズ

Consider pole requirement: 4P for neutral protection applications

Confirm mounting (fixed/drawout) and connection direction (front/rear)

  1. Product Features & Advantages
  2. 経済的 & Practical: ABE series is cost-effective for budget‑limited projects
  3. Standard Design: Complies with IEC standards, interchangeable with other brands
  4. Reliable Protection: Thermal-magnetic trip provides basic overload and short-circuit protection
  5. Flexible Installation: Supports front/rear wiring and multiple mounting methods
  6. Complete Accessories: Can be equipped with auxiliary contacts, alarm contacts, undervoltage release, 等.
  7. メンテナンス & トラブルシューティング
  8. Regular Inspection: Inspect appearance and tighten terminals quarterly to avoid looseness or overheating
  9. Trip Test: Perform manual trip test annually to verify mechanical reliability
  10. トラブルシューティング:

Frequent overload tripping: Check load or replace with higher rated model

Short-circuit tripping: Locate and repair short circuit before closing

Failure to close: Check mechanical jam or replace damaged parts

LS ELECTRIC ABE404B-4P-400A is an economy 4-pole MCCB with 400A rated current and 10kA breaking capacity, suitable for low-voltage distribution systems with moderate breaking requirements. For higher breaking capacity, use ABS (25の) or ABH (35の) シリーズ.

Applications of LS ELECTRIC ABE404B-4P-400A MCCB

コアの位置決め:

This 4-pole economy MCCB (4P, 400あ, 10の) is mainly used for end protection in low‑voltage distribution systems, especially where neutral protection is required, short-circuit current ≤10kA, and budget is limited.

  1. Commercial Building Distribution
応用SuitabilitySelection Tip
Main distribution board main breaker4P protects 3-phase 4-wire; 400A fits small‑to‑medium commercial buildingsTotal load ≤320A (80% duty), short-circuit ≤10kA
Main A/C protection400A for large central A/C units (≤200kW, 380V)Match compressor inrush; recommend undervoltage release
Emergency lighting4P ensures neutral continuity for reliable emergency operationUse with EPS/UPS; front connection for easy maintenance
Elevator room power400A for multiple elevators; 4P prevents neutral faultsInstall in dedicated cabinet; ensure ventilation

Typical Cases:

3–5 story office buildings, chain supermarkets, hotels as main or important branch breaker.

  1. Industrial Plant Applications
  2. General Machinery

Main breaker for small‑medium production lines: 400A covers multiple branches; 10kA suits general industrial short-circuit levels

Motor group protection: Total power ≤200kW, used with thermal relays for precise protection

Auxiliary equipment: Fans, pumps, コンプレッサー; 4P for control circuits with neutral

  1. Specific Industries

Food processing: Cost-effective for light industry; 4P ensures safety and quality

Electronic assembly: 400A for multiple lines; 4P avoids neutral drift affecting precision equipment

Warehouse power: Main breaker for lighting and forklift charging

Warning:

If short-circuit current >10の, upgrade to LS ABS (25の) or ABH (35の).

  1. Public & Residential Buildings
  2. Education & Medical

School main distribution: 4P protects lighting, A/C, computer rooms; 400A for whole building

Community hospital: 4P for medical equipment with neutral; economy for primary care

Stadium auxiliary systems: Lighting, audio, seats; 400A for local zones

  1. Infrastructure

Small wastewater treatment: 400A for pumps and blowers; 4P prevents control system failure

Urban landscape lighting: Main breaker for multi-loop lighting with reliable neutral

Small waste transfer station: 400A for compressors and conveyors; low operating cost

  1. Special Applications
  2. Capacitor Bank Protection

For capacitor banks ≤100kvar; 4P prevents inrush and short-circuit during switching

Recommend adding SPD for surge protection

  1. Small Generator Systems

Main breaker for generators ≤300kVA; 4P ensures safe isolation from grid

Used with synchronizing equipment for smooth switch between mains and generator

  1. Temporary Power

Construction site temporary power main breaker; 400A for cranes, welders

4P suitable for harsh site conditions; prevents electric shock from broken neutral

  1. Key Selection & Application Criteria
要素推奨Not Suitable For
Short-circuit level≤10kA: suitable; >10の: use ABS/ABHHigh-risk areas (chemical, mining) と >10の
Load typeResistive & inductive loads (点灯, モーター)Large rectifiers, arc furnaces, high nonlinear loads
Earthing systemTN-S, TT systems (4P neutral protection)IT systems (operating rooms, mines)
EnvironmentIndoor dry, ≤40°COutdoor, damp, explosive areas (needs special enclosure)
Operation frequencyInfrequent operation (≤12/day)Frequent duty (cranes, elevator main circuits)
  1. Application Advantages
  2. 経済的: High cost-performance for budget projects
  3. Full protection: 4P design covers 3-phase + neutral for modern distribution
  4. Standard compliance: IEC 60947-2, interchangeable with major brands
  5. Flexible installation: Front/rear wiring + 35mm DIN rail
  6. Reliable: 機械式 8500, 電気 1000 operations

Best Combination:

Use ABE404B-4P-400A as main breaker + LS MCBs for branch protection to form a reliable two‑stage system.

For higher performance or electronic protection, upgrade to ABS (25の), ABH (35の), or ABN (electronic trip) シリーズ.