OMRON G3PA-240B-VD Single-Phase Solid State Relay

Omron single-phase SSR, integrated heat sink, DINレールマウント, zero-crossing type ✅ Model Code Explanation G3PA: G3PA series solid state relay with integrated heat sink 2: Output voltage class AC24~240V 40: Rated output current 40A B: Built-in heat sink, screw terminals VD: DC control input DC5~24V, phototriac isolation, zero-crossing, operation indicator light 📋 Key Specifications ...

  • 製品詳細

オムロン single-phase SSR, integrated heat sink, DINレールマウント, zero-crossing type

✅ モデルコードの説明

G3PA: G3PA series solid state relay with integrated heat sink

2: Output voltage class AC24~240V

40: Rated output current 40A

B: Built-in heat sink, ネジ端子

VD: DC control input DC5~24V, phototriac isolation, zero-crossing, operation indicator light

📋 主な仕様

入力側 (制御端子A1/A2)

定格入力電圧: DC 5~24V

動作電圧範囲: DC 4~30V

マックス. 入力電流: 7ミリアンペア (25℃)

ピックアップ電圧: ≤DC4V; ドロップアウト電圧: ≥DC1V

出力側 (負荷端子)

Load voltage: AC24~240V, permissible range AC19~264V (50/60Hz)

定格電流: 40A @40℃; derate to 36A when tightly mounted side by side

Surge current withstand: 440あ (60Hz, 1 サイクル)

On-state voltage drop: ≤1.6V RMS

漏れ電流: ≤20mA@AC200V

Trigger mode: Zero-cross switching (ideal for heating loads to reduce interference)

分離: Phototriac

操作する / リリースタイム: ≤ half cycle +1ms

環境 & 機械式

取り付け: DINレール / ネジ取付

周囲温度: -30~+80℃ (結露や氷結がないこと)

絶縁耐力: AC4000V 1min; insulation resistance ≥100MΩ (DC500V)

端子: ネジ端子

認証: UL, cUL, VDE, CE

📌 一般的なアプリケーション

Electric heating tubes, industrial ovens, injection molding heating, hot air equipment, ON/OFF temperature control for single-phase resistive loads. Not suitable for high-frequency PWM, only for periodic zero-cross switching.

⚠️重要な注意事項

  1. Use 40A rating for resistive loads; 誘導負荷 (モーター, 変圧器) require heavy derating.
  2. When multiple units are tightly installed side by side, derate current to 36A due to poor heat dissipation.
  3. Zero-crossing type: turns on and off only when AC voltage crosses zero. It suppresses EMI but cannot switch at random phase angles.
  4. Non-polarized DC input; can be driven directly by PLC or temperature controller with DC5–24V output.
  5. SSR has no mechanical contacts and cannot provide short-circuit protection. A fuse must be installed upstream.

🔁 Same Series & 代替モデル

G3PA-220B-VD: 20あ / AC24-240V / DC5-24V

G3PA-260B-VD: 60あ / AC24-240V / DC5-24V

G3PA-420B-VD: 20あ / AC200-400V / DC12-24V

国内代替品: 40A zero-cross SSR with integrated heat sink. Verify derating curve and surge rating before replacement.

G3PA-240B CEO (Zero-crossing, 40あ, DC5–24V Controlled SSR) アプリケーションシナリオ

コアの位置決め: ON/OFF temperature control for single-phase AC24–240V resistive loads. DIN rail integrated heat sink, driven by temperature controllers or PLCs. Designed mainly for heating loads, zero-crossing for low EMI, capable of frequent switching. Not for high-frequency PWM or inductive loads such as motors.

🔥 Heating & 温度制御 (主な用途)

  1. 工業用オーブン, hot air circulation ovens, aging chambers, constant temperature cabinets, high-low temperature test chambers (electric heating tubes, quartz heating tubes)
  2. Injection molding barrel heating, extruder die heating, blow molding machine zone heating
  3. Hot press machines, hot stamping machines, heat transfer machines, heating plates for laminators
  4. 包装機械: heat sealers, hot cutting knives, shrink tunnel heating
  5. 食品機械: baking lines, hot air dryers, electric heating for sauce cooking, commercial ovens
  6. 水処理: electric heating boilers, tank heating, pipe trace heating, defrost heating
  7. Vulcanizing machines, single-phase heating circuits for mold temperature controllers. (For 3-phase heating, 使用 3 units separately for each phase.)

🧪 Automation Equipment

  1. 環境試験器, 一定の温度 & humidity machines, electric heating sections of dehumidifiers
  2. 半導体 / PCB production: drying lines, preheating stations for glue coating
  3. リチウム電池設備: vacuum ovens, formation cabinet heating
  4. テキスタイルプリント & 染色: セッティングマシン, drying rooms, hot roller heating
  5. 印刷機: drying tunnels, auxiliary heating for UV systems

💡 Other Resistive Load Switching

  1. High-power halogen lamps, infrared heating lamp banks (resistive lamp loads)
  2. High-power electric heaters for cabinets and clean rooms
  3. Electric auxiliary heating modules for air conditioning / 新鮮な空気システム

アドバンテージ: Zero-cross switching reduces inrush current and interference to temperature instruments, PLCs and power grid.

✅ Suitable Working Conditions

頻繁な切り替え (several to tens of times per minute), avoid contact burnout and arcing of contactors

Driven by PID temperature controllers or PLC digital outputs (DC24V)

DIN rail installation inside control cabinets, compact space, built-in heat sink, no extra heat sink required

高い絶縁性 (4kV 絶縁耐力) and operation indicator for easy commissioning

Single-phase resistive heating loads, mainly AC220V, current ≤40A (derate to 36A when densely mounted)

❌ 推奨されないアプリケーション (選択の落とし穴)

AC motors, ウォーターポンプ, transformers and other inductive loads: high starting surge may cause breakdown. Heavy derating or random-phase SSR / contactor is preferred.

High-frequency PWM dimming (tens of Hz or above): zero-cross SSR cannot perform phase-angle regulation.

容量性負荷.

OMRON G3PA-240B-VD Selection Guide & アプリケーションノート (Product Page Version, 中国語 + 英語)

Optimized for bestcontactor foreign trade website, readable for engineers, buyers and procurement, E-E-A-T compliant.

  1. Selection Checklist — Confirm the 4 Items Before Choosing G3PA-240B-VD

✅ Load type: Single-phase resistive load preferred (加熱管, infrared heaters, 加熱プレート)

✅ Load voltage: AC 24~240V (AC220V most common)

✅ Control signal: DC 5~24V (PLC DO, PID temperature controller output)

✅ Mounting: DIN rail inside cabinet, integrated heat sink

If not satisfied — Recommended Alternatives

  1. 誘導負荷 (モーター, 電磁弁, 変圧器)

Not recommended for this model. Use contactors or random-phase SSR with at least 50% current derating.

  1. 3-phase heating loads

解決: 3 pcs G3PA-240B-VD to control each phase independently. Do not use one unit for 3-phase load.

  1. Power regulation, phase-angle dimming, high-frequency PWM

G3PA is zero-cross SSR, only for ON/OFF cycle control, not phase-angle modulation. Choose OMRON G3PW power controllers if regulation is needed.

  1. Load current near 40A continuously, multiple units tightly arranged

Derate to 36A for dense mounting. Upgrade to G3PA-260B-VD (60あ) if load current is continuously above 36A.

Load Current Formula (for foreign trade page)

Safe current for resistive load = rated load current × 1.25 安全マージン

Multiply by 0.9 derating factor if densely mounted

例: 3000W @AC220V heating tube, current ≈13.6A, sufficient margin for G3PA-240B-VD.

  1. 配線ガイド (Concise for Product Page)

入力 (コントロール): A1, A2, DC5~24V, 無極性

出力 (負荷): power in, ロードアウト; AC side non-polarized

Built-in operation indicator: lights up when control signal is present for easy on-site commissioning

Isolation rating: AC4000V between input and output

重要: Fast fuse must be installed on upstream AC side. SSR cannot withstand short circuit and will be permanently damaged.

  1. アプリケーションノート
  2. 放熱 & ディレーティング

This model has integrated heat sink. Heat dissipation worsens at high cabinet temperature or when tightly mounted side by side; rated 40A derates to 36A. Keep ventilation inside cabinet. Sealed installation without airflow is prohibited.

  1. Zero-crossing Characteristic

The SSR turns on and off only when AC voltage crosses zero. 利点: low inrush current and low EMI. 制限: cannot switch at arbitrary phase angle, not for dimming or phase control.

  1. 漏れ電流

Small residual leakage current (≤20mA @AC200V) exists in OFF state. Tiny loads may show faint heating or glowing, which is normal for SSR. A bleeder resistor can be added to resolve this.

  1. Load Surge

Infrared lamps and quartz tubes have low cold resistance with high inrush current at power-on. This model withstands 440A (60Hz, 1 サイクル). Select a higher current rating if surge exceeds this value.

  1. 周囲条件

動作温度: -30℃~+80℃, 腐食性ガスがないこと, condensation or dust accumulation. Dust and oil will clog heat sink and accelerate aging.

  1. 禁止されている操作

Do not test output short circuit; do not use directly for capacitive loads; avoid frequently surging inductive loads.

  1. Recommended Supporting Items

ヒューズ: ceramic fast fuse

温度調節器: オムロン E5CC / E5EC PID controller

代替機種: G3PA-220B-VD (20あ), G3PA-260B-VD (60あ)

Upgrade for power regulation: G3PW series power controller

  1. よくある質問 (for bottom of product page)

Q: Can G3PA-240B-VD control motors?

あ: 推奨されません. Zero-cross SSR has limited surge withstand and may fail under motor starting current. AC contactor is preferred.

Q: Why is the heating tube still slightly warm after SSR turns off?

あ: It is caused by inherent leakage current of SSR, more obvious on small loads. Add a bleeder resistor.

Q: Can it be driven directly by PLC DC24V output?

あ: はい. Input power consumption is low (約. 7ミリアンペア), standard PLC output points can drive it.

OMRON Solid State Relay SSR Full Series (Foreign Trade Selection Version, Classified, including G3PA)

分類: Integrated heat sink DIN rail type (first choice for cabinet heating), separate heat sink type, fault detection SSR, plug-in I/O miniature SSR, power controller (not regular SSR, often selected together), discontinued models marked.

  1. Integrated Heat Sink DIN Rail SSR (Most Common for Heating, including G3PA)
  2. G3PA (Slim integrated type, replaceable power module)

単相, AC24–240V / AC200–480V, DC5–24V control, zero-crossing

G3PA-210B-VD: 10あ

G3PA-220B-VD: 20あ

G3PA-240B CEO: 40あ (このモデル)

G3PA-260B-VD: 60あ

G3PA-420B-VD: 20あ, AC480V version

G3PA-430B-VD: 30あ, AC480V version

G3PA-450B-VD-2: 50あ, AC480V version

✅ Typical use: オーブン, injection molding heating, mold temperature machines, PID ON/OFF temperature control

  1. G3PE (New compact integrated type, 単相 & 3-段階)

単相: G3PE-215B / 225B / 235B / 245B; 3-phase G3PE-325B, G3PE-345B

利点: better surge tolerance, random-phase version available, suitable for some inductive loads and dimming

取り付け: DINレール, 単相 / 3-phase heating circuits

  1. G3PJ (Low heat dense mounting type, 25A rating remains valid even 3 units tightly side by side)

G3PJ-225B, G3PJ-225B-PU (Push-in spring terminal)

For high-density control cabinets with multi-zone heating

  1. G3PH (High-current integrated type)

75あ / 150あ, AC240V, AC480V, for heavy heating loads

  1. G3PC (SSR with built-in fault detection)

Heater break detection and SSR short-circuit alarm output. Safety-critical heating control, preferred for test chambers and lithium battery ovens.

  1. G3PF (Smart CT current sensing SSR)

Built-in current transformer for real-time heating element break and short-circuit detection. For high-end equipment with alarm logging.

  1. Separate Heat Sink Type (No built-in heat sink, embedded installation, external heat sink required)
  2. G3NA (Classic universal model, large market stock)

単相, 5A~90A, mainly zero-crossing

G3NA-205B / 210B / 220B / 240B / 260B

G3NA-410B / 420B / 440B / 460B (AC480V)

G3NA-290B (90大電流)

サフィックス: -VD = DC5–24V control; models without B are random-phase type

  1. G3NE (Economical low-current, 5A/10A/20A, quick connect terminals)

低コスト, small heating loads, 赤外線ランプ, embedded inside machines

  1. プラグイン / I/O Mini SSR (Same footprint as MY/LY relays, signal and small load switching)

G3F / G3FD: MY relay size, socket mount, small AC/DC loads

G3H / G3HD: LY power relay size

G3R-I/O: G2R footprint I/O isolation SSR

G3RV-ST: 6.2mm slim DIN rail I/O SSR, high-density PLC isolation output

G3TA: SSR matched with G7TC I/O terminal blocks

G3RZ: MOSFET type, AC/DC low-power loads

  1. Power Controllers (Power regulators, not regular ON/OFF SSR)

Phase angle control, cycle control, soft start, for continuous power regulation

G3PW: Single-phase power controller (widely used for regulation instead of SSR)

G3ZA: Multi-channel power controller

G32A-EA: Cycle control unit

  1. PCB Mount SSR (Soldered on PCB, 信号切り替え)

G3S, G3M, G3DZ, G3TB etc. Low current, 信号絶縁, used inside control boards

  1. 生産終了モデル (Frequently asked in foreign trade inquiries)

G3PB, G3NH, G3B/G3BD, old G3RV-SR. Not recommended for new designs; only for spare replacement.

✅ Quick Selection Table (Can be placed directly on product page)

シリーズHeat Sink Type電流範囲主な特長代表的な用途
G3PAIntegrated DIN rail10~60Aスリム, zero-crossing, replaceable power core射出成形, オーブン, general heating
G3PEIntegrated DIN railシングル / 3-phase 15~45ABetter surge resistance, random-phase option加熱, partial inductive loads
G3PJIntegrated DIN rail25あNo derating when densely mountedMulti-zone dense control cabinets
G3PHIntegrated DIN rail75/150あExtra high currentハイパワー暖房
G3PC / G3PFIntegrated DIN rail25~45AFault detection & アラームLithium battery ovens, aging chambers, safety-critical equipment
G3NASeparate heat sink5~90Aユニバーサル, 費用対効果の高いEmbedded inside machines, external heat sink required
G3NESeparate heat sink5~20A経済的Low-power heating
G3PWPower regulator–段階 / cycle power controlContinuous temperature regulation

📌 Suffix Meaning (FAQ for Foreign Trade)

VD: DC5~24V non-polarized DC input (G3PA-240B-VD uses this suffix)

B: Zero-crossing trigger

No B: Random-phase trigger (phase-angle switching, 誘導負荷に適しています)

PU: Push-in spring terminal

-2: 480Vバージョン