商品番号: 120329 | 製品の状態: 廃止 (Discontinued by Manufacturer)
- モデルコードの内訳
`UC2000-F43-2KIR2-V17`
- UC2000: UC series ultrasonic sensor, maximum measuring distance 2000 mm
- F43: Flat rectangular housing (F-type enclosure)
- 2K: 2 relay contact outputs
- 私: Analogue 4…20 mA current output
- R2: Built-in RS232 interface for parameter programming
- V17: Hardware version V17
- 主要な技術仕様
Ranging Performance
| アイテム | 仕様 |
| Effective measuring range | 100 … 2000 mm |
| Blind zone (dead zone) | 0 … 100 mm |
| Transducer frequency | 約. 175 kHz |
| Standard reflector target | 100×100 mm flat plate |
| Measurement resolution | 0.5 mm |
| Non-linearity error | <0.2% of full scale |
| Repeat accuracy | ≤0.1% of full scale |
| Programmable hysteresis | 0~15% of measuring range adjustable |
電気データ
電源電圧:
Without analogue output: 10…30 VDC; With 4–20mA activated: 15…30 VDC
No-load power consumption: ≤0.7 W; マックス. full-load power consumption: ≤2 W
Output Combination (Key Feature)
✅ 2 independent relay outputs (SPDT changeover contacts)
接点定格: 60 VDC / 1 あ (抵抗負荷, 最大. 24 W DC)
✅ 1 analogue 4 … 20 電流出力, maximum load impedance ≤500 Ω
コミュニケーション: RS232, 9600bps, 8N1. Parameter configuration via UC-PROG1-USB and ULTRA2001 software
応答時間: 分. ≤50 ms; Factory default ≤150 ms
機械式 & 環境仕様
繋がり: M12×1 8-pin male connector
保護クラス: IP65
ハウジング材質: PBT thermoplastic
動作温度: -25 ℃~ +70 ℃
保管温度: -40 ℃~ +85 ℃
重さ: 290 g
Built-in temperature compensation
LEDステータス表示
Green LED steady ON: Target within measuring window; Green LED flashing: No target detected
Red LED ON: Fault condition (high acoustic interference, 配線ミス, 等)
- M12 8-Pin Pin Assignment
| ピン | 意味 |
| 1 | DC+ Power Positive |
| 2 | リレー 1 共通端子 |
| 3 | 直流- パワーネガティブ |
| 4 | リレー 2 共通端子 |
| 5 | 4~20mA Analogue Signal Output |
| 6 | リレー 1 通常開 / 通常閉 |
| 7 | リレー 2 通常開 / 通常閉 |
| 8 | シールド (Housing Earth) + RS232 Communication |
⚠️ Important Note: When using the 4–20mA output, supply voltage must not drop below 15 VDC; otherwise analogue output malfunction will occur.
- 代表的な応用分野
- Warehouse & ロジスティクス: Level height detection, pallet presence detection, anti-collision distance measurement
- 包装機械: Roll diameter measurement, material presence monitoring
- 水処理: Non-contact level measurement for open tanks
- 一般的な自動化: All-in-one solution for dual limit switching + continuous distance transmission
アドバンテージ: Single sensor delivers two limit switch signals + continuous distance feedback, 設置スペースの節約.
- 交換オプション (Critical Section)
No direct pin-to-pin upgraded model available with original F43 flat housing. Two selection options:
オプション 1: Functional Equivalent (Requires modified mounting bracket & electrical adaptation)
UC2000-L2-IUR2-V15
測定範囲: 100…2000 mm
出力: 4–20mA analogue + 2 PNP switching outputs + RS232
違い: トランジスタ出力, no relay contacts; Cylindrical housing with different mounting dimensions
If passive relay contacts are mandatory on site, select third-party ultrasonic sensor paired with external relay.
オプション 2: Maintain Relay Output
Only used / refurbished stock available for legacy series. For new projects:
UC2000-L2-IUR2-V15 + auxiliary miniature relay for contact conversion.
- 選択 & 運用ガイドライン / 落とし穴の回避
- Blind Zone Limitation: Reliable measurement impossible within 100 mm; Do not select for close-range applications.
- Acoustic Cone Interference: Activate sensor synchronisation function when multiple sensors are installed side-by-side to prevent mutual ultrasonic interference.
- Medium Limitation: Soft foam, fluffy fabrics produce weak echo and lead to unstable detection.
- Relay Service Life: Electrical service life limited to 3×10⁵ switching cycles. Not suitable for high-frequency switching applications. Transistor output models are recommended for frequent operation.
- Programming Requirement: Adjustment of switching points, measuring range and hysteresis requires UC-PROG1-USB programming cable. No external teach-in button available.
- トラブルシューティング マトリックス
| 故障の症状 | 根本的な原因 | 是正措置 |
| Analogue output locked at 4mA / 20ミリアンペア | Target out of measuring range / Undersupply voltage | Verify supply ≥15 VDC; Confirm target is within 100~2000 mm range |
| Relay triggers falsely and frequently | Acoustic reflection interference, insufficient hysteresis setting | Increase hysteresis parameter; Install separation baffles; Enable synchronisation mode |
| Red LED continuously illuminated | 過剰な電源リップル / Internal sensor failure | Add power supply filter; Check shielding wiring of pin 8 |
| Communication connection failure | Incorrect RS232 wiring, mismatched baud rate | Confirm 9600,8N1 setting; Use original UC-PROG1 adapter |
ペッパール+フックス UC2000-F43-2KIR2-V17 Practical Application Cases
Core Feature Recap (All cases based on unique strengths of this model)
Flat F43 rectangular housing, measuring range 100~2000 mm;
2 SPDT passive relay contacts + 4…20mA analogue output + RS232 programmable interface;
Highlight: Single sensor integrates dual limit switching + continuous distance transmission. Passive relay contacts can directly drive contactors and audible/visual alarms. Flat housing fits confined mounting spaces; IP65 rated with built-in temperature compensation.
Important Reminder: This sensor is discontinued by the manufacturer. Alternatives are recommended for new projects. The below cases are proven historical applications.
Cse 1 | 廃水処理: Level Monitoring & Pump Control for Open Settling Tank
Working Conditions
Open regulating tank in small wastewater treatment plant with surface foam and high humidity. 要件:
① Continuous level signal transmitted to PLC via 4–20mA;
② Low-level pump start, high-level pump stop (two relays directly control contactors to reduce PLC point consumption);
③ Limited installation space above tank guardrail, cylindrical sensors cannot be fitted.
Implementation Scheme
Sensor installed horizontally with downward tilt above the tank, avoiding severe foam zones.
リレー 1: High level limit (1.6 メートル) → Trigger to stop drainage pump
リレー 2: Low level limit (0.4 メートル) → Trigger to activate water inlet
4–20mA signal sent to central control for real-time liquid level display
RS232 used on-site to calibrate measuring range and hysteresis, suppressing frequent fluctuation caused by water ripples.
Reason for Model Selection
Flat F43 housing compatible with narrow mounting brackets; Passive relays drive contactors directly without additional auxiliary relays. Ultrasonic measurement immune to water colour and mild foam.
Risk Notes
Thick foam absorbs ultrasound; proper mounting tilt required. Blind zone of 100 mm prevents low-level alarm setup near tank bottom.
場合 2 | Plastic Extrusion Industry: Residual Roll Diameter Monitoring for Film / Nonwoven Web
Working Conditions
Continuous unwinding of raw material rolls on cast film production line. Control system requirements:
- Real-time roll outer diameter measured; 4–20mA signal sent to tension controller for automatic unwinding torque regulation;
- Dual limit: Low material pre-warning + complete roll depletion safety shutdown.
Implementation Scheme
Sensor mounted laterally on machine frame, aligned horizontally with roll outer surface; 0.1~2m measuring range matches maximum roll diameter.
リレー 1: Minimum roll diameter reached (pre-warning) → Audible & visual alarm for material preparation
リレー 2: Roll diameter hits minimum limit → Full production line safety shutdown
Continuous 4–20mA analogue distance output for roll diameter conversion and closed-loop tension control.
Selection Advantage Comparison
Conventional transistor-output sensors rely on PLC logic for dual alarm functions. Built-in relays enable direct wiring to alarm circuits for legacy retrofit projects without modifying PLC programs.
Operation Tip
Surface wrinkles and web vibration cause signal fluctuation; configure sufficient measurement hysteresis via software.
場合 3 | Logistics Conveyor Line: Pallet Height Detection & Dual Position Limit
Working Conditions
Roller conveyor for automated warehouse transporting wooden / plastic pallets. Photoelectric sensors prone to false triggering caused by dust and pallet gaps. 要件:
① Confirm pallet arrival (near-point switch);
② Overheight pallet detection to prevent jamming in vertical lift;
③ Real-time pallet height data uploaded to WMS for cargo dimension verification.
Implementation Scheme
Sensor side-mounted above conveyor channel:
リレー 1: Pallet arrival confirmation signal
リレー 2: Pallet overheight alarm, trigger conveyor emergency stop
4–20mA output of measured pallet height sent to upper system for cargo dimension validation.
コアバリュー
Slim flat housing embedded into narrow side space of conveyor. Ultrasonic detection unaffected by pallet holes and dust; passive relay contacts compatible with legacy safety circuits.
場合 4 | Chemical Raw Material Hopper: Granular Level Monitoring (Plastic Pellets, Calcium Carbonate)
Working Conditions
Open-top raw material hopper for small extruders. Heavy dust environment unsuitable for capacitive level switches. 要件:
Low-level pre-warning, high-level full hopper shutdown, plus continuous level monitoring.
Implementation Scheme
UC2000-F43 installed laterally at hopper top:
リレー 1: High material level → Stop feeding conveyor motor
リレー 2: Low material level → Start raw material feeding conveyor
4–20mA signal transmitted to central control for daily raw material consumption tracking.
予防
Severe dust clouds attenuate ultrasonic echo; avoid vertical installation facing falling material stream.
場合 5 | 建設機械 / AGV: Anti-collision Distance Warning System
Working Conditions
Indoor factory Automated Guided Vehicle (AGV). Dual-stage collision protection required:
- Long-distance pre-warning (speed reduction); 2. Short-distance emergency stop; Continuous distance signal sent to on-board controller.
Implementation Scheme
Flat-mounted F43 sensor on AGV outer body (cylindrical sensors protrude and risk collision damage). Measuring range 100~2000 mm:
リレー 1: 1.2 m detection distance → Vehicle speed reduction
リレー 2: 0.5 m danger distance → Emergency stop
4–20mA real-time distance signal for obstacle distance display on vehicle HMI.
アドバンテージ
Flat housing resists scratches from cargo. Independent safety relay circuit enables emergency stop even if main controller fails.
場合 6 | 包装機械: Stacked Carton Height Monitoring
Working Conditions
Palletising station for carton stacking. Verify stack height compliance and implement overheight protection.
リレー 1: Stack height reaches target → Robot executes transfer operation
リレー 2: Overheight stack → Equipment lock and alarm
Continuous 4–20mA height data for production data acquisition.
Suitable for rigid flat-surface targets such as cartons and turnover boxes.
まとめ: Ideal Application Characteristics for This Model (Selection Checklist)
✅ Preferred Application Scenarios
- Confined installation space requiring flat rectangular housing; cylindrical ultrasonic sensors cannot be fitted
- Retrofit projects with existing control cabinets using passive contact signals; no intention to expand PLC I/O points
- Processes requiring dual limit switches + continuous analogue transmission integrated within one sensor
- Direct drive of 220 VAC audible/visual alarms or contactors (passive relay contacts)
- Environment with wide temperature fluctuation, ほこりや湿気 (内蔵温度補償, IP65)
❌ Unsuitable Scenarios
- Applications with millions of frequent switching cycles (limited mechanical relay life; transistor-output sensors preferred)
- Targets made of thick / soft foam (ultrasound absorption leads to poor detection)
- Measurement distance below 100 mm (inherent blind zone)
コンタクタ,サーキットブレーカー,ソーラーインバーター,電気メーター,太陽電池


















NH42-63-318x560.png)