SK-R1-FAN1-F8: Cooling Fan Kit for Rockwell PowerFlex 750 Series SK-R1-FAN1-F8 is an inverter cooling fan kit manufactured by Allen-Bradley (Rockwell Automation), designed as an internally mounted spare part specifically for PowerFlex 750 Series Frame 8 AC drives. Core Specifications & Features Parameter Description Brand Allen‑Bradley (Rockwell Automation) Product Type Fan Kit, Inverter Heat Sink Applicable ...

  • 製品詳細

SK-R1-FAN1-F8: Cooling Fan Kit for Rockwell PowerFlex 750 シリーズ

SK-R1-FAN1-F8 is an inverter cooling fan kit manufactured by Allen-Bradley (Rockwell Automation), designed as an internally mounted spare part specifically for PowerFlex 750 Series Frame 8 AC drives.

Core Specifications & 特徴

パラメータ説明
ブランドAllen‑Bradley (Rockwell Automation)
製品タイプFan Kit, Inverter Heat Sink
Applicable EquipmentPowerFlex 750 Series Frame 8 AC Drive
取り付けInternal Mount
Lifecycle StatusACTIVE
Main FunctionProvides forced convection cooling for the inverter section of the drive, preventing overheating of power components
適用規格C-TICK, KC
Typical PriceApproximately US$3,780–3,835 per set (varies by distributor)

モデルの解釈

SK-R1: Prefix for cooling-related components in the Rockwell PowerFlex series

FAN1: Single-fan configuration (SK-R1-FAN2-F8 is the dual-fan version)

F8: Fits Frame 8 size drives

アプリケーション

This fan kit is a critical cooling component for PowerFlex 750 Series Frame 8 variable frequency drives, used in high-power industrial automation applications including:

Large motor speed control

Heavy machinery drive systems

Industrial production line automation

Energy and infrastructure projects

注意事項

  1. This is an original spare part; installation and maintenance should be performed by qualified technicians.
  2. Must be used with exact matching PowerFlex 750 Series Frame 8 drive models.
  3. Regularly inspect fan operation to ensure proper cooling system function and extend drive service life.

SK-R1-FAN1-F8 vs SK-R1-FAN2-F8

Detailed Parameter Comparison & Frame 8 Drive Compatibility List

  1. Core Parameter Comparison
パラメータSK‑R1‑FAN1‑F8SK‑R1‑FAN2‑F8Key Difference
Full Product NamePowerFlex 750 Inverter Heat Sink Fan KitPowerFlex 750 Internal Stirring Fan Kit with TrayFunctional purpose: primary cooling vs auxiliary airflow circulation
コア機能Provides forced convection cooling for inverter power modules, preventing overheating of IGBTs and other devicesOptimizes internal airflow distribution, eliminates local hot spots, and assists the main cooling systemCooling priority: FAN1 = primary, FAN2 = auxiliary
Fan ConfigurationSingle large centrifugal fan (R3G310‑AN48‑78)Two small stirring fans with mounting trayDifferent fan quantity and type
風量 (CFM)約. 1,200–1,400 CFM (ebmpapst R3G310 series, ドイツ)約. 2 × 200 CFM (dual fan combination)FAN1 has significantly higher airflow
消費電力約. 470W, 3あ, 230Vと約. 2 × 30W, 0.25A × 2, 24ワシントンDCでFAN1 has higher power and different voltage rating
取り付け位置Dedicated position for inverter heat sinkGeneral internal mounting position with trayDifferent mounting location and fixing method
重さ約. 9.5 kg (20.94 lb)約. 3.2 kg (7.05 lb)FAN1 is heavier due to large fan
Frame CompatibilityFrame 8–10 (primarily Frame 8)Frame 8 onlyFAN1 covers more frames
Typical PriceUS$3,780–3,835/setUS$1,200–1,500/setFAN1 is more expensive
Lifecycle StatusACTIVEACTIVEBoth are currently available spares
適用規格C-TICK, KCC-TICK, KCSame electrical safety compliance
取り付けInternal MountInternal Mount with trayFAN2 is simpler to install
  1. Power Ratings & Typical Models for Frame 8 Drives

2.1 Applicable Power Range

PowerFlex 750 Series Frame 8 drives cover the following power ratings (varies by voltage):

VoltageRated Power Range定格電流範囲
400Vと450kW–560kW (ND/HD)770A–850A
480Vと400kW–500kW (ND/HD)740A–820A
690Vと375kW–450kW (ND/HD)460A–520A

2.2 Compatible Drive Model List

SK-R1-FAN1-F8 is compatible with these PowerFlex 750 Series Frame 8 drives:

PowerFlex 753 シリーズ (20F prefix)

20F11NDxxxxNNNNNN (標準, 400/480V)

20F11TDxxxxNNNNNN (With DC Terminals, 400/480V)

20F11LDxxxxNNNNNN (Light Duty, 400/480V)

20F11HDxxxxNNNNNN (Heavy Duty, 400/480V)

PowerFlex 755 シリーズ (20G prefix)

20G11NDxxxxNNNNNN (標準, 400/480V)

20G11TDxxxxNNNNNN (With DC Terminals, 400/480V)

20G11LDxxxxNNNNNN (Light Duty, 400/480V)

20G11HDxxxxNNNNNN (Heavy Duty, 400/480V)

20G1ABDxxxxNNNNNN (Common converter module, Frame 8–10)

20G1ALDxxxxNNNNNN (Common inverter module, Frame 8–10)

PowerFlex 758 シリーズ (20P prefix, high performance)

20P11NDxxxxNNNNNN (標準, 400/480V)

20P11TDxxxxNNNNNN (With DC Terminals, 400/480V)

General Rule: All Frame 8 PowerFlex 750 drives (753/755/758) are compatible with SK-R1-FAN1-F8; some Frame 9–10 models also apply. SK-R1-FAN2-F8 is designed exclusively for Frame 8 and is not compatible with Frame 9–10.

  1. 選択 & Application Recommendations

When SK-R1-FAN1-F8 is Required

All newly installed Frame 8 drives

Drives operating under Heavy Duty (HD) or high ambient temperature (>40℃) conditions

Replacement after inverter cooling fan failure

When SK-R1-FAN2-F8 is Recommended

Local hot spots inside the drive

High altitude (>1000メートル) or enclosed cabinet installation

Need to improve internal airflow for better overall cooling efficiency

インストールに関する注意事項

Both can be installed together for a complete “primary cooling + auxiliary airflow” solution

Installation must be performed by qualified technicians to ensure safe electrical and mechanical connections

Disconnect power and allow heat sinks to cool fully before replacement to avoid burns

Inspect fan operation and clean dust regularly (recommended every 6 月)

Complete List of Cooling Fan Models

for Rockwell PowerFlex 750 シリーズ

Below is the complete official list of cooling fan kits for the PowerFlex 750 シリーズ, categorized by function type and frame size, including the SK-R1 (internal core cooling components) and SK-R9 (external cooling fan kits) シリーズ.

  1. SK-R1 Series: Internal Core Cooling Fan Kits

1.1 Frame 8 Specific Core Cooling Fans

モデルFull Name説明FrameLifecycle
SK‑R1‑FAN1‑F8PowerFlex 750 Inverter Heat Sink Fan KitPrimary cooling: forced convection for inverter power modules, fits Frame 8–10, includes large centrifugal fan (R3G310‑AN48‑78)Frame 8 (Frame 9–10 compatible)ACTIVE
SK‑R1‑FAN2‑F8PowerFlex 750 Internal Stirring Fan KitAuxiliary cooling: optimizes internal airflow, eliminates hot spots, includes mounting trayFrame 8ACTIVE
SK‑R1‑FAN2H‑F8PowerFlex 750 Internal Stirring Fan KitAuxiliary cooling: high‑performance internal stirring fan for improved circulationFrame 8ACTIVE
SK‑R1‑FAN4‑F8PowerFlex 750 IP54 Blower Assembly KitProtected cooling: blower system for IP54 environmental ratingFrame 8ACTIVE
SK‑R1‑FANH1‑F8PowerFlex 750 Fan Harness KitWiring component: dedicated harness for cooling fan electrical connectionFrame 8ACTIVE
SK‑R1‑FUSEFAN‑F8PowerFlex 750 Converter Input Fuse Stirring FanLocal cooling: stirring fan designed specifically for the converter input fuse areaFrame 8ACTIVE

1.2 Frame 9–10 Specific Cooling Fans

モデルFull Name説明FrameLifecycle
SK‑R1‑FAN1‑F9PowerFlex 750 Inverter Heat Sink Fan KitFrame 9 primary cooling fan, same function as F8 with matched dimensionsFrame 9ACTIVE
SK‑R1‑FAN1‑F10PowerFlex 750 Inverter Heat Sink Fan KitFrame 10 primary cooling fan, maximum airflow configurationFrame 10ACTIVE
SK‑R1‑OCARTFAN‑F9PowerFlex 750 FR9 Option Slot Fan Tray KitOption area cooling: directed cooling for Frame 9 option slot (including reactors)Frame 9ACTIVE
SK‑R1‑OCARTFAN‑F10PowerFlex 750 FR10 Option Slot Fan Tray KitOption area cooling: directed cooling for Frame 10 option slotFrame 10ACTIVE
  1. SK-R9 Series: External Cooling Fan Kits (By Protection Rating)

2.1 NEMA Type 1 / IP20 External Cooling Fans (Frame 1–7)

モデルFull Name説明FrameLifecycle
SK‑R9‑FAN11‑F1PowerFlex 750 タイプ 1 Heat Sink Fan KitBasic external cooling for Frame 1, NEMA 1 ratedFrame 1ACTIVE
SK‑R9‑FAN11‑F2PowerFlex 750 タイプ 1 Heat Sink Fan KitBasic external cooling for Frame 2, NEMA 1 ratedFrame 2ACTIVE
SK‑R9‑FAN11‑F3PowerFlex 750 タイプ 1 Heat Sink Fan KitBasic external cooling for Frame 3, NEMA 1 ratedFrame 3ACTIVE
SK‑R9‑FAN11‑F4PowerFlex 750 タイプ 1 Heat Sink Fan KitBasic external cooling for Frame 4, NEMA 1 ratedFrame 4ACTIVE
SK‑R9‑FAN11‑F5APowerFlex 750 タイプ 1 Heat Sink Fan KitBasic external cooling for Frame 5, NEMA 1 ratedFrame 5ACTIVE
SK‑R9‑FAN11‑F6PowerFlex 750 タイプ 1 Heat Sink Fan KitBasic external cooling for Frame 6, NEMA 1 ratedFrame 6ACTIVE
SK‑R9‑FAN11‑F7APowerFlex 750 タイプ 1 Heat Sink Fan KitBasic external cooling for Frame 7, NEMA 1 ratedFrame 7ACTIVE

2.2 NEMA Type 4X/12 / IP66/54 Protected External Cooling Fans (Frame 4–7)

モデルFull Name説明FrameLifecycle
SK‑R9‑FAN14‑F45PowerFlex 750 Type 4X Heat Sink Fan KitProtected external cooling for Frame 4–5, NEMA 4X/12 ratedFrame 4–5ACTIVE
SK‑R9‑FAN14‑F6PowerFlex 750 Type 4X Heat Sink Fan KitProtected external cooling for Frame 6, NEMA 4X/12 ratedFrame 6ACTIVE
SK‑R9‑FAN14‑F7APowerFlex 750 Type 4X Heat Sink Fan KitProtected external cooling for Frame 7, NEMA 4X/12 ratedFrame 7ACTIVE
  1. Other Related Cooling Components
モデルFull Name説明FrameLifecycle
SK‑R9‑FAN2‑F23PowerFlex 750 Internal Fan KitGeneral internal cooling for Frame 2–3Frame 2–3ACTIVE
SK‑R9‑FAN2‑F45PowerFlex 750 Internal Fan KitGeneral internal cooling for Frame 4–5Frame 4–5ACTIVE
SK‑R1‑OCARTFAN‑F9PowerFlex 750 FR9 Option Slot Fan Tray KitDirected cooling for Frame 9 option slot (including reactors)Frame 9ACTIVE
SK‑R1‑OCARTFAN‑F10PowerFlex 750 FR10 Option Slot Fan Tray KitDirected cooling for Frame 10 option slotFrame 10ACTIVE
  1. モデルの命名規則

PowerFlex 750 cooling fan models follow a unified coding system:

PrefixMain IdentifierSuffix意味
SK‑R1-FAN[number]-F[frame]-[variant]Internal core cooling components; FAN1 = primary fan, FAN2 = stirring fan, FAN4 = IP54 blower, F[number] = frame size
SK‑R9-FAN[number]-F[frame]-[variant]External cooling fan kits; FAN11 = NEMA Type 1, FAN14 = NEMA Type 4X, F[number] = frame size
  1. 選択 & Application Guide
  2. Primary cooling fan is mandatory: All new PowerFlex 750 drives must be equipped with the corresponding frame-matched SK-R1-FAN1-Fx (internal primary) or SK-R9-FAN11-Fx (external primary) ファン.
  3. Auxiliary cooling recommendation: For high ambient temperature (>40℃), high altitude (>1000メートル), or enclosed cabinet installations, add SK-R1-FAN2-Fx series stirring fans.
  4. Protection rating matching: For outdoor or dusty environments, select SK-R9-FAN14-Fx-series NEMA 4X protected fans.
  5. Frame compatibility–: SK-R1-FAN1-F8 is compatible with Frame 8–10; all other models are frame-specific.

 