Schneider MGNEA9C45C1630CA Integrated Residual Current Circuit Breaker with Overcurrent Protection (RCBO) Product Line: Easy9 EA9C45 Integrated RCBO Model Breakdown: MGNEA9C45 = Upgraded Easy9 1P+N integrated RCBO; C16 = C-curve, 16定格電流; 30 = 30mA residual current; CA = Type A residual protection (plain C stands for Type AC) ✅ Core Technical Parameters Poles: 1P+N ...

  • 製品詳細

シュナイダー MGNEA9C45C1630CA Integrated 残留電流遮断器 過電流保護付き (RCBO)

Product Line: Easy9 EA9C45 Integrated RCBO

モデルの内訳:

MGNEA9C45 = Upgraded Easy9 1P+N integrated RCBO; C16 = C-curve, 16定格電流; 30 = 30mA residual current; CA = Type A residual protection (plain C stands for Type AC)

✅ Core Technical Parameters

極: 1P+N (DPN, 段階 + 中性), 2 モジュール / 36幅mm

定格電流: 16あ

トリップ曲線: タイプC (磁気トリップ: 5~10インチ; for lighting & 一般的なソケット回路)

定格動作電圧: AC230V, 50Hz

定格残留動作電流: 30ミリアンペア (high sensitivity for personal shock protection)

Residual current type: タイプA (detects AC sinusoidal leakage + 脈動DC漏れ; suitable for variable-frequency appliances, switch-mode power supplies, 充電器, small EV charging circuits)

Rated short-circuit breaking capacity Icn: 4.5の

保護機能: 過負荷保護 + 短絡保護 + 漏電保護 (3-in-1)

取り付け: 35mm DINレール

Max wire cross-section: 16mm² copper cable; 締め付けトルク: 2.5N・m; top-in bottom-out wiring

持久力: 電気 & 機械的寿命: 20,000 サイクル

規格: GB16917, IEC61009; with CCC certification

📌 Selection Differentiation (致命的)

MGNEA9C45C1630C: ACタイプ, only detects AC leakage; for pure resistive lighting & ソケット回路

MGNEA9C45C1630CA: タイプA; preferred for phone chargers, inverter air conditioners, 給湯器, water purifiers, small EV charging circuits (mandatory for modern residential electrical installations)

📍 Typical Application Scenarios

Residential indoor socket circuits, 台所 & bathroom circuits, single-phase power distribution in small retail premises.

Not suitable for direct-on-line starting of high-power motors.

⚠️ Replacement Options

  1. Direct same-series replacement: MGNEA9C45C1630CA (タイプA)
  2. Domestic equivalent alternatives: Chint NXBL-32 1P+N C16 30mA Type A; Delixi HDBE-40LE, 等.
  3. Upgraded Schneider series: iC65N Vigi (iC65N + separate residual current attachment, 6kA遮断容量)

📋 Troubleshooting Guide

  1. 閉店直後の旅行: Earth leakage fault (Type A is more sensitive to DC leakage), or live-neutral cross-connection
  2. Intermittent tripping under load: Minor line-to-earth leakage, or internal power supply board leakage from connected equipment
  3. Cannot close the switch: Short circuit or overload; disconnect downstream loads before retesting
  4. テストボタン (T): Press once per month; the breaker should trip normally

Schneider MGNEA9C45C1630CA (EA9C45 1P+N C16 30mA Type A) vs Other Brands’ 1P+N RCBOs

Product positioning: Easy9 contractor-grade integrated RCBO, electronic Type A, 4.5kA遮断容量, 2 モジュール (36mm), neutral pole non-switched

Comparison scope: Chint NXBL, Delixi HDBE, ルグラン, Siemens 5SU1, ABB 1P+N RCBOs

  1. Common Structural & Wiring Characteristics (All 1P+N Models)

✅ Shared features: Only the live (L) pole is disconnected during tripping; 中性 (N) pole remains continuous. The neutral pole has no overload/short-circuit protection. Strict L/N polarity is required; polarity reversal is forbidden. All models are 2-module (36mm) DIN rail mounted, 30mA instantaneous trip, Cカーブ.

⚠️ This is an inherent design of 1P+N breakers, not exclusive to Schneider. It differs fundamentally from 2P RCBOs (which cut both live and neutral poles).

  1. Key Differences Between Brands

(1) 残留電流タイプ (Most Common Pitfall)

This Schneider model: タイプA (CA suffix). Detects both AC leakage and pulsating DC leakage; compatible with chargers, inverter AC, LED drivers, small EV chargers and switch-mode power supplies. This is the standard Type A required for modern residential & high-end renovation projects.

Many entry-level domestic 1P+N breakers: Default Type AC, only responding to sinusoidal AC leakage. They will fail to trip when DC leakage occurs from electronic loads, creating hidden safety risks.

Full Model List for MGNEA9C45 Series (Original Schneider Order Codes)

(1) C Curve | タイプA (CA suffix, mainstream residential model)

定格電流Full Order Code備考
6あMGNEA9C45C630CAタイプA, 30ミリアンペア
10あMGNEA9C45C1030CAタイプA, 30ミリアンペア
16あMGNEA9C45C1630CA (Your selected model)タイプA, 30ミリアンペア
20あMGNEA9C45C2030CAタイプA, 30ミリアンペア
25あMGNEA9C45C2530CAタイプA, 30ミリアンペア
32あMGNEA9C45C3230CAタイプA, 30ミリアンペア
40あMGNEA9C45C4030CAタイプA, 30ミリアンペア

(2) C Curve | ACタイプ (C suffix, legacy model for pure AC loads)

定格電流Full Order Code
6あMGNEA9C45C630C
10あMGNEA9C45C1030C
16あMGNEA9C45C1630C
20あMGNEA9C45C2030C
25あMGNEA9C45C2530C
32あMGNEA9C45C3230C
40あMGNEA9C45C4030C

(3) D Curve | タイプA (CA suffix, for motors & impulse loads)

定格電流Full Order Code
16あMGNEA9C45D1630CA
20あMGNEA9C45D2030CA
25あMGNEA9C45D2530CA
32あMGNEA9C45D3230CA
40あMGNEA9C45D4030CA

(4) Derived K-type (Both live & neutral poles switched, ACタイプ)

MGNEA9C45C1630CK

MGNEA9C45C2030CK

Unified Technical Specifications for the Whole Series

極: 1P+N (DPN); 幅: 36mm (2 モジュール)

遮断容量: Icn = 4.5kA

漏れタイプ: 電子, 瞬間トリップ, 30ミリアンペア

配線: Max 16mm² copper wire; 締め付けトルク: 2.5N・m

電圧: AC230V, 50Hz

工事: Monoblock integrated RCBO (not a MCB plus separate RCD attachment)

Phase-out Notice

  1. Old part numbers without the MGN prefix (EA9C45C1630C) have been upgraded to the new MGNEA9C45 range.
  2. Low-current Type AC variants are gradually being discontinued. New projects are recommended to specify CA Type A.

クイックセレクションガイド

  1. General sockets, kitchen/bath circuits, inverter appliances → C curve + カリフォルニア州 (タイプA)
  2. Pure resistive incandescent lighting loads → Type C (交流) is acceptable
  3. ウォーターポンプ & small motors → D curve + カリフォルニア州 (タイプA)

 