Modicon Advantys STB distributed remote I/O, NIM Network Interface Module (Standard CANopen NIM) Full Designation: STBNCO2212, commonly abbreviated as NC02212 in the industry ✅ Model Code Explanation STB: Advantys STB distributed I/O series NCO: NIM + CANopen (CO = CANopen) 2212: Standard NIM supporting expanded I/O islands (the basic version is STBNCO1010) 📌 Key Specifications ...

  • 製品詳細

Modicon Advantys STB distributed remote I/O, NIM Network Interface Module (Standard CANopen NIM)

Full Designation: STBNCO2212, commonly abbreviated as NC02212 in the industry

✅ Model Code Explanation

STB: Advantys STB distributed I/O series

NCO: NIM + CANopen (CO = CANopen)

2212: Standard NIM supporting expanded I/O islands (the basic version is STBNCO1010)

📌 Key Specifications

  1. バスプロトコル: CANopen, まで 1 メガビット/秒, DB9 male CAN bus connector
  2. 電源: DC24V (モジュール電源), provides 5.25V to the STB backplane bus inside the I/O island

-25℃~+60℃: 1.2あ; derated to 0.575A from 60℃ to 70℃

  1. I/O Island Capacity: 1 primary segment, 最大 6 expansion segments; まで 32 STB I/O modules per single I/O island
  2. 保護クラス: IP20 (DINレール取付, キャビネット設置のみ)
  3. 重さ: 約. 0.135 kg
  4. 動作温度: Standard -25℃ ~ +70℃ (wide-range version, FM認定)

Equipped with rotary DIP switches to set the CANopen node ID

Onboard status LEDs for bus, fault and module run diagnostics

Automatically scans all STB I/O modules within the island and performs auto-configuration; supports standard CANopen services including PDO, SDO and NMT

Note for analog applications: DS401 protocol. Object 6423h must be enabled to activate TxPDO transmission of analog values

📦 Application Scenarios

Distributed I/O signal acquisition and output for packaging machinery, textile equipment, 生産ライン, クレーン, water treatment and other machinery using CANopen.

⚠️ Lifecycle & 交換オプション

The STB series is an older generation of distributed I/O. STBNCO2212 is obsolete, only spare stock and used units available.

置換選択:

オプション 1: Keep CANopen → Migrate to Modicon TM7 CANopen remote I/O (TM7NCO1)

オプション 2: Upgrade to Ethernet → TM7 Ethernet NIM (TM7ETH1), full replacement of the STB I/O island

🔎 NIM Family Comparison (for easy identification)

STBNCO2212: CANopen

STBNDP2212: プロフィバスDP

STBNIP2212: Modbus TCP

STBNIC2212: イーサネット/IP

STBNDN2212: デバイスネット

🧰 Key Troubleshooting Points

  1. CAN bus communication failure: Check DB9 wiring, terminating resistors (120Ω at both ends of the bus), ensure no duplicate node IDs set via DIP switches
  2. Module red LED on power-up: Backplane 5V overload inside the island, excessive I/O modules or backplane short circuit
  3. No analog value upload: CANopen object dictionary entry 6423h is not set to 1
  4. High-temperature alarm: Ambient temperature exceeds 60℃, backplane current derating and excessive I/O load

STB I/O Island Hardware Wiring Overview (STBNCO2212)

DIN rail mounting sequence [left to right]: STBNCO2212 (NIM) → optional PDM power distribution module → DI/DO/AI/AO I/O modules → XBE expansion modules (for multi-segment expansion) → STBXMP1100 end termination cover

  1. NIM (STBNCO2212) DC24V Power Terminals

Spring terminals below the NIM supply power to the NIM itself, which converts internally to 5.25V for the island backplane bus (logic power for all internal I/O modules).

Positive terminal: DC24V+

Negative terminal: DC24V 0V

✅ Requirements: SELV extra-low safety voltage power supply, operating range 19.2~30VDC; small fuse recommended; reverse polarity forbidden.

Backplane output: DC5.25V, 最大. 1.2A for logic power of all I/O modules on the island. Exceeding this rating triggers red overload fault.

  1. CANopen DB9 Male Pin Assignment (Front of STBNCO2212)
DB9 Pin No.信号説明
2CAN_LCAN Low
3CAN_GNDCAN bus ground
5CAN_SHLDCable shield (single-ended connection to cabinet earth)
7CAN_HCAN High
1,4,6,8,9予約済みNo connection

CAN Bus Wiring Rules

  1. ケーブル: Shielded twisted pair complying with CiA DR303-1
  2. Fit one 120Ω terminating resistor at each physical end of the CAN bus; no terminating resistors at intermediate nodes
  3. シールド: Single-point earthing only. Do not earth both ends (to avoid ground loop interference)
  4. Baud rate is set via two rotary DIP switches on the NIM, changes only take effect after power cycle. Node ID is also set by DIP switches; no duplicate IDs allowed on the same bus.
  5. I/O Island Backplane Bus (Inter-module connection)

Communication and 5V logic bus between NIM and I/O modules are implemented via metal contacts on STBXBA2000 base plates. No extra wiring required. Modules lock onto the base to automatically connect the backplane.

Single primary segment: I/O modules mounted directly to the right of NIM. STBXMP1100 termination cover must be fitted at the far right end of the segment.

Multi-segment expansion: Fit STBXBE1000 EOS expansion module at the end of primary segment. Use dedicated expansion cable to connect to the next I/O segment. マックス. 6 expansion segments; まで 32 I/O modules total per island.

  1. Field I/O Load Power Supply (センサー / 電磁弁)

⚠️ Distinguish two separate power circuits:

① Backplane 5.25V: Only powers internal electronics of I/O modules (supplied by NIM). Cannot feed external sensors or solenoid valves.

② Field 24V load supply: Powers DI sensors and DO solenoids, introduced via PDM power distribution modules (STBPDT series) and distributed to downstream I/O modules.

  1. DI デジタル入力 (例: STBDDI3610)

Module terminals: 24V+, 0V, channel I0~I5 etc.

For NPN/PNP sensors, connect common terminal according to module datasheet to 24V or 0V

  1. デジタル出力DO

Output common terminal QC connects to load power to drive solenoid valves and indicators

  1. Analog AI/AO (STBACI / STBAVO series)

4-20ミリアンペア / 0~10V signals. Use shielded cable and route separately from power cables. Object 6423h must be activated for AI modules to enable PDO upload.

  1. 試運転 & Fault Notes for Wiring
  2. Power-up sequence: Complete all field I/O wiring → Verify CAN bus and terminating resistors → Apply DC24V power to NIM last
  3. Red LED on power-up: ① DC24V reverse / 不足電圧; ② backplane 5V overload (too many I/O modules or backplane short); ③ CAN bus ID conflict
  4. Irregular flashing CAN communication LED: Check reversed CAN_H/CAN_L, terminating resistors, shield earthing, matching baud rate between master and NIM
  5. No analog data: Write SDO to set 6423h=1 to enable analog PDO transmission

Schneider Advantys STB I/O Island (STBNCO2212) 一般的な障害 & 救済策

Faults grouped by category: NIM hardware faults, backplane faults, CANopen communication faults, I/O channel faults, software configuration faults. LED interpretation follows STBNCO2212 official manual.

  1. NIM Red ERR LED steady ON, fails to start

症状: NIM ERR red LED stays on, RUN LED off; I/O island cannot be scanned

  1. NIM DC24V supply abnormality

原因: DC24V below 19.2V, excessive ripple, 逆極性, loose supply terminals

救済策: Measure terminal voltage of NIM; replace stabilized DC24V supply; verify polarity and fit fuse

  1. 過負荷 / short circuit of island backplane 5.25V (high-frequency fault)

原因: NIM max backplane output 1.2A, total logic current of I/O modules exceeds rating; burnt or deformed metal contacts on base plates; analog modules draw higher current and trigger this fault more easily

救済策:

電源を切る, remove I/O modules one by one to isolate the faulty module by sectioning

Calculate total logic consumption of all modules. Add STBCPS2111 auxiliary backplane power supply if overloaded

Inspect STBXBA2000 base plates for burn marks and bent spring contacts

  1. Poor contact between module and base plate

原因: DIN rail not clipped securely, module not fully latched, oxidized spring contacts on base

救済策: Remove and re-seat all modules, clean metal contacts, confirm firm DIN rail mounting

  1. NIM hardware damage

原因: Surge or overvoltage destroying internal power circuit

救済策: Power NIM alone disconnected from I/O island. If ERR remains red, replace STBNCO2212

  1. CANopen Communication Fault (CAN ERR red LED flashing / steady ON, PLC reports slave missing)

症状: NIM CAN ERR alarm; PLC cannot detect STB slave or slave drops intermittently

  1. Physical CAN wiring defect (most frequent)

原因: CAN_H / CAN_L を反転; loose DB9 terminals; missing 120Ω terminators at bus ends, or incorrectly fitted terminators on intermediate nodes; ground loop due to shield earthing at both ends

救済策: Verify DB9 pinout; install 120Ω only at two physical ends; single-point shield earth; CiA standard shielded twisted pair; separate routing away from high-power cables

  1. Duplicate Node ID / Baud Rate Mismatch

原因: DIP switch node ID duplicated on CAN bus; NIM baud rate different from CAN master; DIP switch modifications only take effect after power cycle

救済策: 電源を切る, reset DIP switches to ensure unique IDs; match baud rate (125k/250k/500k/1M) between master and NIM, reboot island

  1. Heartbeat / Guard Timeout (Heartbeat/Guard fail, ERR flashes twice)

原因: Bus interference, long cable length; too short heartbeat timeout parameter configured in master

救済策: Shorten cable length, improve shielding; increase slave heartbeat timeout in PLC master; eliminate earthing interference

  1. CAN Controller Error Alarm (ERR flashes once)

原因: Persistent bus disturbance, error counter overflow

救済策: Check grounding and coupling interference from power cables; inspect cable damage; reduce number of bus nodes

CAN RUN Green LED Reference:

Off = Initialization; Steady ON = Communication OK; Flashing = Pre-operational; Slow flash = Stopped state

  1. Failure to detect some I/O modules (Advantys tool reports missing / mismatched module type)

症状: After power-up self-test, NIM only detects partial I/O modules; Advantys software reports missing hardware

  1. Missing STBXMP1100 termination cover at segment end

原因: No termination cover fitted at right end of I/O segment, backplane signal corrupted, modules further downstream not detected

救済策: Install STBXMP1100 termination cover at end of single segment

  1. Faulty STBXBE1000 expansion module / damaged expansion cable

原因: For multi-segment islands, failed EOS/BOS expansion module or loose/broken dedicated expansion cable

救済策: Re-seat expansion cable; test expansion module standalone; dedicated expansion cable cannot be substituted with ordinary wire

  1. Mismatch between physical hardware and configuration

原因: Hardware module type differs from project configuration in Advantys software; new module fitted without re-downloading configuration

救済策: Perform online auto-scan of I/O island, download new hardware configuration to NIM, press NIM RST button to reboot island

  1. Damaged base plate

原因: Broken backplane contact spring on base plate, all modules after this position cannot communicate

救済策: Replace STBXBA2000 base plate

  1. Digital DI/DO Channel Faults

DI No Input Signal

原因: Missing 24V field load power from PDM (Distinguish from NIM logic power! NIM only supplies backplane 5V; sensor power comes from PDM); wrong common wiring; mismatch between NPN/PNP sensor and module type; 断線したセンサーワイヤー

救済策: Measure 24V output of PDM; verify DI common wiring; check sensor power and signal cable

DO No Output / Uncontrolled Output

原因: No load power connected to DO common QC terminal; shorted load burns DO channel; DO enters fail-safe state on communication loss; hardware channel damage

救済策: Check 24V supply at DO QC terminal; inspect solenoid valve load for short; check PLC communication status; force output test to confirm hardware failure

  1. Analog AI/AO No Reading / Jumpy Values (STBACI/STBAVO)
  2. AI no acquisition data

原因: CANopen object dictionary 6423h not set to 1, analog TxPDO disabled by default; unshielded analog cable with heavy interference; loss of sensor supply; open 4-20mA loop

救済策: Write SDO to set 6423h=1 to enable TxPDO; use shielded analog cable routed away from power cables; inspect sensor loop continuity

  1. Analog value drift or random fluctuation

原因: Ground loop interference; analog cables run together with power cables; loose terminal screws

救済策: Single-point earth for analog shield; separate cable trays; 端子を締める; inspect sensor

  1. ソフトウェア構成 & Download Faults (Advantys Configuration Tool)
  2. Configuration download failure, cannot write to NIM

原因: Unstable communication link; NIM locked to original master; incompatible old firmware/software version

救済策: Check CAN communication; clear master lock on NIM; update Advantys software; reset NIM before re-download

  1. Software warning: insufficient logic bus current

原因: Total logic consumption of all island modules exceeds NIM 5.25V backplane rating

救済策: Add STBCPS2111 auxiliary backplane power or split hardware into two separate I/O islands

  1. Intermittent Random Faults (hardest to troubleshoot)

Typical symptoms: Random communication dropouts, sporadic point flicker; faults more likely to occur under machine vibration

  1. Vibration-induced loose terminals / base plate spring contacts
  2. Incorrect CAN shield earthing, pulse interference generated by large power equipment switching
  3. Undersized DC24V power supply, voltage dip during load fluctuation
  4. 周囲温度 >60℃, NIM backplane current derating and insufficient I/O power (0.575A from 60~70℃)

救済策: Tighten all terminals; rectify shield earthing; upgrade DC24V power rating; improve cabinet cooling to reduce ambient temperature

  1. Recommended On-site Troubleshooting Sequence
  2. Observe NIM front-panel LEDs to narrow fault domain (NIM power / backplane / CAN bus)
  3. 電源を切る, visual inspection of modules, base plates and wiring for burn marks and looseness
  4. Measure DC24V supply at NIM terminals
  5. Disconnect CAN bus and power up I/O island standalone to isolate fault to either internal backplane or external field bus
  6. Remove I/O modules sequentially to locate faulty module or base plate
  7. Check CAN bus: terminating resistors, CAN_H/CAN_L, shield earthing, node ID and baud rate
  8. Use Advantys software online diagnosis to read internal NIM fault words
  9. Finally perform channel tests and force I/O points to validate hardware condition
  10. Safety Notes Before Shutdown

When CAN communication is lost, STB DO outputs enter pre-defined fail-safe state (所有 / リセット, defined in configuration). Safety interlocks must be considered for actuators.

Power down the entire I/O island before removing modules or modifying DIP switches. Hot-swap of STB modules on base plates is forbidden.

Schneider Modicon Advantys STB Full Model List (STB I/O Island)

カテゴリー: NIM network interface modules, PDM power distribution modules, digital DI/DO, analog AI/AO, special function modules, base plates, expansion and accessories. The full series is obsolete; only spare and used stock available.

  1. NIM Network Interface Master Modules (I/O Island Gateway, STBNCO2212 belongs here)
モデルBus Type備考
STBNCO1010CANopenBasic economy type, limited I/O capacity
STBNCO2212CANopen標準バージョン, まで 32 I/Oモジュール (model discussed)
STBNDP2212プロフィバスDPStandard DP NIM
STBNIP2212Modbus TCP10M Ethernet, 標準
STBNIP2311Modbus TCPEnhanced version with extended functions
STBNIC2212イーサネット/IPEtherNet/IP protocol
STBNDN1010デバイスネットBasic DeviceNet
STBNDN2212デバイスネットStandard DeviceNet
  1. PDM Power Distribution Modules (supply external 24V for DI sensors & 電磁弁)
モデル仕様
STBPDT2100AC110/230V distribution
STBPDT2105AC110/230V with built-in fuse
STBPDT3100DC24V distribution, commonly used
STBPDT3105DC24V with integrated fuse protection
  1. Backplane Auxiliary Power Module (to boost 5.25V logic current when NIM capacity insufficient)

STBCPS2111: Backplane auxiliary supply module, shares the 5V logic load of the island

  1. Digital Input DI Modules (24VDC / 交流)

DC24V DI (最も広く使用されている)

STBDDI3425: 4から, 基本的な

STBDDI3610: 6から, 標準 (frequently used on projects)

STBDDI3725: 16から, high-density basic module

AC DI

STBDAI5260: 2-point 115VAC isolated input

  1. Digital Output DO Modules

DC24V Solid-state Output

STBDDO3415: 4する, 0.25あ

STBDDO3600: 6する, 0.5A standard

STBDDO3705: 16する, high-density output

AC DO

STBDAO5260: 2-point 115VAC isolated output, 2あ

STBDAO8210: 2-point 115/230VAC output, 2あ

  1. Analog Input AI (現在 / 電圧, 4-20ミリアンペア, 0~10V, HART capable)

STBACI0320: 4-channel 4-20mA

STBACI1225: 2-channel 4-20mA (older design)

STBACI1400: 8-channel 4-20mA

STBACI8320: 4-channel 4-20mA, HART protocol supported

STBAVI0300: 4-channel 0~10V voltage input

STBAVI1400: 8-channel voltage input

  1. アナログ出力AO

STBACO0120: 1-channel 4-20mA

STBACO0220: 2-channel 4-20mA

STBACO8220: 2-channel 4-20mA, ハート

STBAVO0200: 2-channel 0~10V voltage output

  1. 特殊機能モジュール

STBDRC3210: Relay output module

STBEHC3020: High-speed counter module

STBEPI2145: Pulse positioning module

  1. 拡張モジュール (for multi-segment I/O island cascading)

STBXBE1000: EOS expansion transmitter (at segment end)

STBXBE2100: BOS expansion receiver (start of next segment)

Used with dedicated STBXCAxxxx expansion cables, 最大. 6 expansion segments

  1. Base Plates (STBXBA series, every module requires matching base)
モデル幅目的
STBXBA100013.9mmNarrow base, for basic DI/DO/AI/AO
STBXBA200018.4mmStandard wide base for NIM, PDM, expansion modules
STBXBA210018.4mmCompatible with STBCPS2111 auxiliary power
STBXBA220018.4mmDedicated base for PDM power distribution modules
STBXBA3000Wide baseFor high-density 16-point DI/DO modules
  1. Terminal Connectors & End Accessories

端子 (spring-clamp / ネジ端子)

STBXTS1100, STBXTS1110, STBXTS1180, STBXTS2100, STBXTS2110, STBXTS5510, STBXTS5610, STBXTS6510, STBXTS6610

End Termination Cover (required at far right of each single I/O segment)

STBXMP1100: I/O segment termination cover for backplane bus

  1. Quick Reference for Model Naming Convention

STB + タイプコード + 数字

Nxx: NIM network interface module

PDT/CPS: 力 / power distribution module

DDI: DC digital input

DDO: DC digital output

DAI/DAO: AC digital I/O

ACI: Analog current input; AVI analog voltage input

ACO: Analog current output; AVO analog voltage output

XBA: Base plate; XBE: Expansion module; XMP: Termination cover

補足: Suffix K = Kit (モジュール + ベース + terminal block complete set). Without K = module only; base plate and terminals must be ordered separately.

例: STBDDI3610 = module only; STBDDI3610K = complete kit