The core differences of CHINT circuit breakers lie in series positioning, breaking capacity, tripping characteristics, pole specifications, expansion functions, application scenarios, and price . 소형 회로 차단기 (MCBs) are mainly used for residential applications, while moldedcase circuit breakers (MCCBs) and air circuit breakers (ACBs) are preferred for industrial purposes. Selection should match the load requirements and budget constraints.

  1. Core Series Classification and Positioning
SeriesTypeCore Positioning일반적인 시나리오
DZ47 (including DZ47S)Miniature Circuit Breaker (MCB)Classic basic model with high cost – 유효성Old projects, budgetfriendly residential decoration, and smallscale commercial power distribution
NXB/NXBLEMiniature Circuit Breaker/Residual Current Circuit Breaker with Overcurrent Protection (MCB/RCBO)Upgraded version of DZ47, core model of Kunlun SeriesResidential decoration, smallscale projects requiring basic protection and modular expansion
NB3/NB6/NBE7Miniature Circuit Breaker/Residual Current Circuit Breaker with Overcurrent Protection (MCB/RCBO) (Taiji Series)높은 – end for home decoration, balancing appearance and performance높은 – end finished residential buildings, smart homes, and home decoration with high safety and appearance requirements
NXMMoldedCase Circuit Breaker (MCCB)Power distribution and motor protection, mediumcapacityIndustrial power distribution, building power distribution, and motor circuits (63A–1600A)
NM5MoldedCase Circuit Breaker (MCCB)높은 – performance MCCB with high breaking capacity and intelligenceNew energy projects, largescale infrastructure, and highreliability industrial power distribution
NA1/NA8Air Circuit Breaker (ACB)Largecapacity main switch with intelligent coordinated controlMain incoming lines of distribution rooms and main circuits of large factories (800A–6300A)
  1. Key Technical Parameter Differences (Core Comparison Between Miniature and MoldedCase Circuit Breakers)
  2. Core Differences of Miniature Circuit Breakers (MCB/RCBO)
ParameterDZ47NXBNB6NBE7NB3
Breaking Capacity6그만큼6그만큼 (better arcextinguishing performance)6kA/10kA (높은 – end models)6그만큼6그만큼
Tripping CurveB/C/DC/D (higher precision)C/D (10mA residual current protection optional)C/DC/D
극 구성1P/1P+N/2P/3P/4P1P/1P+N/2P/3P/4P1P/1P+N/2P/3P/4P1P/2P/3P/4P1P/1P+N/2P/3P/4P
정격전류6A–63A6A–63A6A–63A16A–40A (50/63A not available)6A–63A
Expansion FunctionsBasicSupports shunt trip, undervoltage trip, and alarm accessoriesSupports intelligent accessories and 10mA residual current protectionBasicSlim design (18mm), appearanceoriented
PriceLowest낮은 – medium중간 – 높은중간 (높은 비용 – 유효성)중간
  1. Core Differences of MoldedCase Circuit Breakers (MCCB)
ParameterNXMNM5
정격전류63A–1600A16A–1000A
Ultimate ShortCircuit Breaking Capacity (중환자실)25kA–50kA36kA–70kA
Service ShortCircuit Breaking Capacity (Ics)50%–100% of Icu100% of Icu
Accessory ExpansionRegular modularizationCan be equipped with 4 types of accessories, miniaturized design
Intelligent FunctionsBasic protectionSmart IoT connectivity and remote monitoring

III. Key Selection Points (By Scenario)

  1. Residential Decoration Selection

Budgetpriority: NBE7 (16A–40A) or NXB, featuring high cost – 유효성.

안전 – priority: NB6 (10mA 잔류 전류 보호) or NB3 (slim design), suitable for families with infants and young children and smart homes.

Old house renovation: Direct replacement with DZ47 without modifying the airconditioning circuit.

Circuit Breaker TypeSeriesRated Current RangeBreaking CapacityCore Application일반적인 시나리오
MoldedCase Circuit Breaker (MCCB)NXM, NXMS16A–1600A25kA–70kAProtection for power distribution trunk lines and power equipmentIndustrial power distribution, largecapacity loads, and generators
Air Circuit Breaker (ACB)NA1, NXA, NA5400A–6300A50kA–120kAProtection for main incoming lines and busbars of power gridsFactory distribution rooms, data centers, and main power distribution of buildings
  1. Comparison of Mainstream Miniature Circuit Breaker (MCB) Series (높은 – frequency for Sales)

MCBs are crucial for enduser selection. The following are the key differences among CHINT’s most commonly used MCB series, which directly affect quotation and customer communication:

ParameterNXB (Upgraded Version of DZ47)NB6NBE7DZ47 (Classic Model)
Breaking Capacity10그만큼6그만큼6그만큼6그만큼
Tripping CharacteristicsType B/C/DType C/DType C/DType C/D
극 구성1P/1P+N/2P/3P/4P1P/1P+N/2P/3P/4P1P/2P/3P/4P1P/2P/3P/4P
정격전류6A–125A (including 125G)6A–63A16A–40A6A–63A
Expansion FunctionsSupports shunt trip, undervoltage trip, and alarm accessoriesBasic model with few accessoriesBasic model with redgreen indicatorNo expansion accessories
Price PositioningMidrange (높은 비용 – 유효성)Midto highend (appearancepriority)Entrylevel (lowest price)Economyclass (being phased out)
Selection SuggestionMainstream choice for residential and commercial use높은 – end home decoration and smart homesBudgetconstrained and smallcurrent branch circuitsRenovation of old projects and temporary power supply

 

  1. Differences in Key Technical Parameters (Frequently Asked by Customers)
  2. Tripping Characteristics

Type B: Tripping current of 3In–5In, suitable for sensitive electronic equipment such as computers and PLCs.

C형: Tripping current of 5In–10In, suitable for general loads like lighting and ordinary sockets (mainstream for residential use).

D형: Tripping current of 10In–20In, suitable for loads with high starting inrush current such as motors, 에어컨, and compressors.

  1. Pole Selection

1P: Only disconnects the live wire (엘), used for lowpower branch circuits like lighting, with the lowest cost.

1P+N: Disconnects the live wire and monitors the neutral wire (N), costeffective and suitable for ordinary sockets.

2P: Disconnects both the live wire and neutral wire simultaneously, highly safe, used for highpower household appliances such as air conditioners and water heaters.

3P/4P: Used for threephase equipment (예를 들어, industrial motors and water pumps). 3P disconnects threephase live wires, and 4P disconnects threephase live wires plus the neutral wire.

  1. Breaking Capacity

Breaking capacity determines whether a circuit can be reliably disconnected during a shortcircuit. For residential use, a breaking capacity of over 6kA is recommended; for industrial and commercial applications, over 10kA is advisable to prevent arc faults.

  1. Quick Selection Guide (For Fast Customer Recommendations)

Regular residential use: NXB Series (10kA breaking capacity, full pole configurations, expandable with accessories, suitable for most residential decoration projects).

Budgetconstrained: NBE7 (low price, with status indicators, suitable for smallcurrent branch circuits).

높은 – end residential decoration: NB6 (elegant appearance, complete specifications, suitable for smart homes and demanding customers).

Industrial power applications: Prioritize NXM moldedcase circuit breakers or NA Series air circuit breakers, as their breaking capacity and accessories are better suited for heavyduty loads.

Ⅶ. Core Differences from Competitors (씨줄, 슈나이더)

Price: CHINT’s products are 15%–30% cheaper than ABB and Schneider products of the same specifications, boasting a distinct costeffectiveness advantage, which is suitable for budgetsensitive customers.

Accessory ecosystem: CHINT’s modular accessories (예를 들어, shunt trip and undervoltage trip) are more affordable and highly compatible, facilitating quotation combinations.

차단 용량: 낮은 – to midrange MCBs (예를 들어, DZ47) have a breaking capacity of 6kA, while the mainstream NXB Series reaches 10kA, which is on par with the midrange series of international brands.

 