How to Select the Right ABB Residual Current Circuit Breaker

How to Select the Right ABB Residual Current Circuit Breaker with Overcurrent Protection (RCBO) for Household Use

The core principle of selecting an ABB Residual Current Circuit Breaker with Overcurrent Protection (RCBO) for household applications is to match household load characteristics, meet safety standards, and fit the distribution box space. Priority should be given to the ABB Compact Home series (예를 들어, GSH200 series), following the specific steps below:

  1. Clarify Core Selection Parameters

Five key parameters must be confirmed for household RCBOs, none of which can be omitted:

  1. 극 구성: Prioritize 1P+N

1P+N (예를 들어, GSH201 series) is suitable for all single-phase household circuits (조명, 소켓, 에어컨). The neutral pole remains permanently closed, with only the phase pole being switchable, saving distribution box space (너비: only 17.5mm).

If both the phase and neutral lines need to be switched off simultaneously (예를 들어, main switch in humid areas), 2P (예를 들어, GSH202 series) is an option. It has a width of 35mm and a slightly higher cost.

  1. 정격전류 (In): Calculate Based on Load Power
Household Circuit TypeRecommended Rated CurrentCorresponding Model Example
Lighting circuits (LED/fluorescent lamps)6A/10AGSH201 AC-C6/0.03
General socket circuits (mobile phones, small household appliances)16에이GSH201 AC-C16/0.03
High-power socket circuits for air conditioners/kitchens (2–3 HP air conditioners, electric ovens)20A/25AGSH201 AC-C20/0.03
  1. Tripping Curve: Uniformly Select Type C for Households

Type C tripping curve: The instantaneous tripping current is 5–10 times the rated current, which can avoid the inrush current during the startup of household appliances (예를 들어, refrigerator, air conditioner startup) without causing nuisance tripping.

메모: Type D curve is suitable for motors and does not need to be selected for household scenarios.

  1. Rated Residual Operating Current (IΔn): Select According to Regional Safety Requirements

Residual current is the core parameter for electric shock prevention. Households should follow the standards below:

Applicable AreaRecommended Rated Residual Operating CurrentSafety Description
Living rooms, bedrooms, lighting circuits (dry areas)30엄마Balances safety and avoidance of nuisance tripping, complying with the requirements of National Standard GB 16917
Bathrooms, kitchens, balconies (humid areas)10엄마High sensitivity, tripping faster (≤0.04s) in case of leakage, with model suffix /0.01
Main incoming switch100엄마 (optional)Prevents whole-house leakage, but must be used with branch circuit RCBOs of 30mA/10mA
  1. Residual Current Type: Prioritize Type A for Compatibility with All Household Appliances

Type AC: Only detects pure AC leakage, suitable for traditional resistive loads (예를 들어, incandescent lamps, electric kettles). However, it cannot detect leakage with DC components (예를 들어, LED drivers, switching power supplies, inverter air conditioners), and is not recommended for whole-house use.

Type A: Can detect AC + pulsating DC leakage, compatible with all household loads (especially smart home appliances and inverter equipment). It is the first choice for households, with model example: GSH201 A-C16/0.03.

  1. Match Requirements of Special Household Scenarios
  2. Humid Areas (Bathrooms, Kitchens)

Pole configuration: 2P (it is recommended to switch off both phase and neutral lines simultaneously)

Rated residual operating current: 10엄마

Residual current type: Type A

Recommended model: GSH202 A-C16/0.01

  1. High-power Equipment Circuits (Instant Water Heaters, Electric Floor Heating)

정격전류: 32에이 (check equipment power; 예를 들어, an 8kW water heater requires a 32A rating)

차단 용량: Select Icn≥6kA (ABB GSH200 series defaults to 6kA, meeting household short-circuit current requirements)

Recommended model: GSH201 A-C32/0.03

  1. Households with Smart Home Appliances/Grid-connected Photovoltaic Systems

Residual current type: Type A must be selected to avoid protection failure caused by DC leakage from photovoltaic inverters and smart home appliances.

메모: Type AC is strictly prohibited, 그렇지 않으면, the risk ofleakage without trippingwill occur.

III. Recommended ABB RCBO Models for Household Use

응용 시나리오Recommended ModelCore Advantages
Universal sockets/lighting for the whole houseGSH201 A-C16/0.03Type A leakage protection, C16 rating suitable for most loads, high cost-effectiveness
Humid areas such as bathrooms/kitchensGSH202 A-C16/0.012P switching, 10mA high sensitivity, preventing electric shock in humid environments
3 HP air conditioners/high-power kitchen appliancesGSH201 A-C25/0.0325A rated current, compatible with the startup of high-power loads
  1. Installation and Selection Precautions
  2. Check Distribution Box Space: 1P+N models have a width of 17.5mm, and 2P models have a width of 35mm. Confirm the remaining rail length of the distribution box.
  3. Compatibility Check: ABB GSH200 series has the same dimensions as the SH200 series miniature circuit breakers, allowing mixed installation.
  4. Certification Requirements: Must select models with 3C certification (예를 들어, GSH201 series certificate number: 2020980305001187) to ensure compliance with national standards.
  5. Avoid Misunderstandings:

Do not blindly choose an excessively high rated current (예를 들어, 32A for socket circuits), which will prevent tripping during overload and cause fire risks.

Do not use Type AC for smart home appliance circuits, 그렇지 않으면, the leakage protection function will fail.

  1. 요약

The simplest solution for selecting ABB RCBOs for households:

> For branch circuits, select 1P+N+Type A+C16/20A+30mA (GSH201 A-C16/0.03); for humid areas, select 2P+Type A+C16+10mA; for the main switch, 2P+Type A+C63+100mA is optional. This scheme balances safety, compatibility, and economy.