- Model Breakdown
| 암호 | 설명 |
| A9F18325 | Official order number for Schneider Electric Acti9 iC65N Miniature Circuit Breaker |
| IC65N | Product series: Acti9 iC65 series, N-type breaking capacity (6그만큼), thermal-magnetic trip unit |
| 3피 | Number of poles: 3 극 (3-phase 3-wire), can switch off three phases simultaneously |
| C25A | C-curve tripping, rated current 25A (at 30°C) |
- 주요 기술 매개변수
| 목 | 사양 |
| 상표 | 슈나이더 일렉트릭 |
| 제품 시리즈 | Acti9 iC65N |
| 유형 | Miniature Circuit Breaker (MCB), thermal-magnetic trip |
| 정격전류 | 25에이 (at 30°C) |
| Poles | 3피 (3 protective poles) |
| Tripping Curve | C-curve (instantaneous trip at 5–10In, for distribution and lighting circuits) |
| 차단 용량 | 6그만큼 (compliant with IEC/EN 60898-1) |
| 정격전압 | 400뷔와 (3-단계), 230뷔와 (single-phase) |
| 정격 주파수 | 50/60헤르츠 |
| Mounting | 35mm standard DIN rail mounting |
| Ambient Conditions | Temp: -25°C ~ +40°C, 고도 2000m 이하, humidity ≤95% (non-condensing) |
| Protection | Overload protection (thermal trip) and short-circuit protection (magnetic trip) |
- Product Features
- 높은 신뢰성: Thermal-magnetic tripping provides accurate overload and short-circuit protection
- 모듈형 디자인: Compact size, saves panel space, easy installation and maintenance
- Wide Application: For all low-voltage distribution systems: residential, commercial and industrial
- Certifications: Complies with IEC/EN 60898-1, GB10963.1 and other international & national standards
- Long Service Life: Mechanical life ≥20,000 operations, electrical life ≥5,000 operations
- Applications
3‑phase distribution systems: Overload and short-circuit protection for 3‑phase circuits
Lighting circuits: 3‑phase lighting protection in large commercial buildings and industrial plants
Power equipment: Control and protection of small 3‑phase motors, pumps, 팬, 등.
Distribution boards / cabinets: Main or branch switch for low-voltage distribution systems
- Replacement Models & Cross-Brand Comparison
5.1 Schneider Same-Series Replacements
| 모델 | Difference | Application Change |
| A9F18320 | 20에이, C-curve, 3피 | For lower load current |
| A9F18332 | 32에이, C-curve, 3피 | For higher load current |
| A9F19325 | 25에이, D-curve, 3피 | For inductive loads such as motors |
| A9F18225 | 25에이, C-curve, 2피 | Single-phase circuit protection |
- Installation & 사용법 참고 사항
- 설치 전, confirm model matches system parameters: check rated current, poles and tripping curve
- Must be mounted on standard 35mm DIN rail for secure installation
- Ensure terminals are tightly connected to avoid overheating
- Inspect breaker status regularly to ensure proper tripping mechanism
- After a fault trip, eliminate the cause before manually resetting
- 선택 권장 사항
- C-curve is suitable for distribution and lighting circuits; not recommended for frequent-start motors (use D-curve)
- 3P breakers are for 3-phase 3-wire systems; use 4P if neutral protection is required
- 6kA breaking capacity is for general industrial & 상업용 건물; use higher-rated types (e.g. H-type 10kA) for high short-circuit current
Recommended Replacements for A9F18325-IC65N-3P-C25A
- Direct Replacements (슈나이더 일렉트릭)
| Replacement Model | Order No. | Key Parameters | Difference | Application |
| IC65N 3P C25A | A9F18325 | 3피, C25A, 6그만큼 | Identical, original | Same distribution protection |
| IC65N 3P C20A | A9F18320 | 3피, C20A, 6그만큼 | 20에이 (lower) | 3-phase lighting / distribution with lower load |
| IC65N 3P C32A | A9F18332 | 3피, C32A, 6그만큼 | 32에이 (higher) | 3-phase lighting / distribution with higher load |
| IC65N 3P D25A | A9F19325 | 3피, D25A, 6그만큼 | D-curve (10–14In trip) | 3-phase motors, compressors and inductive loads |
| IC65H 3P C25A | A9F28325 | 3피, C25A, 10그만큼 | 10그만큼 (higher breaking capacity) | Industrial environments with high short-circuit current |
| IC65L 3P C25A | A9F38325 | 3피, C25A, 15그만큼 | 15그만큼 (highest level) | Critical power systems with very high fault current |
| IC65N 4P C25A | A9F18425 | 4피, C25A, 6그만큼 | 4 극 (includes neutral protection) | 3-phase 4-wire systems |
- Upgraded Replacements (New Schneider Series)
| 시리즈 | 모델 | Order No. | Upgrade Advantage | Application |
| Acti9 IC60N | IC60N 3P C25A | A9F58325 | More compact, higher short-circuit withstand | New projects with limited panel space |
| Acti9 IC40N | IC40N 3P C25A | A9P58325 | Ultra-slim (18mm/pole), space-saving | Small distribution boards, residential / 광고 |
- Cross-Brand Equivalent Replacements
| 상표 | 모델 | Key Parameters | Match | Cost |
| 씨줄 | S203-C25 | 3피, C25A, 6그만큼 | ★★★★★ | 중간, reliable quality |
| 지멘스 | 5SY6325-7CC | 3피, C25A, 6그만큼 | ★★★★★ | 중간, German quality |
| 친트 | NXB-63-3P C25 | 3피, C25A, 6그만큼 | ★★★★☆ | Lower, high-quality domestic |
| 맛있는 | CDM30s-63C25/3300 | 3피, C25A, 6그만큼 | ★★★★☆ | Lower, cost-effective |
| Changshu Switch | CH1-63C25/3P | 3피, C25A, 6그만큼 | ★★★★☆ | Lower, well-known domestic brand |
| Liangxin | NDM1-63C25/3P | 3피, C25A, 6그만큼 | ★★★★☆ | Lower, suitable for industry |
Key Selection Advice for Replacements
- Direct equivalent: Prefer IC65N 3P C25A (A9F18325) to match original protection characteristics
- Tripping curve:
C-curve (5–10In): distribution & 조명
D-curve (10–14In): 모터, transformers to avoid nuisance tripping
- 차단 용량:
6그만큼 (N-type): general commercial & residential
10그만큼 (H-type): industrial & large commercial
15그만큼 (L-type): critical systems with high fault current
- Poles:
3피: 3-phase 3-wire (no neutral protection)
4피: 3-phase 4-wire (단계 + 중립 보호)
- Brand choice:
국제적인 (씨줄, 지멘스): stable, for critical equipment & export projects
국내의 (친트, 맛있는): cost-effective, for general industrial & civil projects
접촉기,회로 차단기,태양광 인버터,전기 계량기,태양 전지