ABB ACS355 series general machinery drive, 0.37 kW / 0.5 HP, single-phase 200–240 V input, IP20 protection, rated output current 2.4 에이. Suitable for speed control and energy-saving operation of small machinery.
1 Model Code Explanation
| Code Part | Meaning |
| ACS355 | ABB general machinery drive series |
| 01E | Protection class IP20, for installation in enclosed electrical cabinets |
| 02A4 | Rated output current 2.4 에이 |
| 2 | Single-phase 200–240 V AC (±10%), 50/60 Hz input |
2 Key Technical Data
| 목 | 값 |
| Rated power | 0.37 kW (0.5 HP) |
| Rated output current | 2.4 에이 (at 40°C) |
| Input voltage / 빈도 | Single-phase 200–240 V AC (±10%), 50/60 헤르츠 |
| Output voltage / 빈도 | Three-phase 0–240 V AC, 0–500 Hz |
| Protection class | IP20 (indoor cabinet installation) |
| Control method | Scalar control (V/f), built-in application macros |
| Overload capability | 150% 정격 전류의 60 에스; 180% for 2 에스 |
| Cooling method | Natural cooling |
| 치수 (W×H×D) | 169×70×135 mm |
| 무게 | 대략. 1.2 kg |
| Order code | 3AUA0000058166 |
| EMC performance | Built-in EMC filter, compliant with EN 61800-3 |
3 Key Features
3.1 Flexible Control
Predefined application macros: constant torque, fan/pump, PID control, 등.
Local/remote control switching via keypad, terminals or fieldbus
Built-in PID controller for closed-loop flow, pressure, 등.
3.2 Reliable Protection
Overcurrent, overload, overvoltage, 저전압, overheating, phase loss protection
Motor over-temperature protection (requires external PTC)
Short-circuit and earth-fault protection
3.3 Easy Operation
Compatible control panel with ACS350/510/550 series
Parameter copy function for fast commissioning
MTBF > 100,000 hours for continuous operation
4 일반적인 응용 분야
Small conveyors, 포장 기계
Fans, pumps (small HVAC systems)
Mixers, centrifuges and small processing machines
Automatic doors, roller shutters
Medical equipment, laboratory instruments
Textile, printing and other light industrial machinery
5 Installation & Commissioning Guidelines
5.1 설치 요구 사항
Must be installed in an enclosed electrical cabinet
Ambient temperature: 0–40°C (derate 10% at 40–50°C)
Mount vertically, keep ≥ 100 mm clearance above and below for cooling
Avoid dust, oil, corrosive gases
Input protection: 10 A MCCB (C-curve) or fuse recommended
5.2 Basic Commissioning Steps
- Pre-power check: Verify wiring (L1/N input, U/V/W output), terminal torque, proper earthing
- Parameter initialization
Group 99: set motor rated voltage, 현재의, power, speed
Select application macro (Standard, PID, 등.)
- Control configuration
Local control: via control panel
Remote control: via DI terminals or optional Modbus RTU
- Operation test
No-load test: run at 5–10 Hz, check rotation and stability
Load test: gradually apply load, verify current and temperature
Adjust acceleration/deceleration time (1–10 s recommended)
6 Cross-Brand Replacement Options (0.37 kW, 1-phase 220 다섯, IP20)
| Brand | 모델 | Key Matching Points |
| 슈나이더 | ATV12HU04M2 | 0.37 kW, 1-phase 220 다섯, IP20, similar size |
| 지멘스 | V20 6SL3210-5BB12-5UV1 | 0.37 kW, 1-phase 220 다섯, IP20, integrated EMC |
| 친트 | NVF2-0.37/2 | 0.37 kW, 1-phase 220 다섯, IP20, economical alternative |
| ABB alternative | ACS150-01E-02A4-2 | Same power range, more compact design |
7 Selection & 유지 관리 팁
7.1 Recommended Options
Braking function: optional braking resistor (75 Ω / 50 W recommended)
Communication: add RS485 module
Enhanced EMC: additional input EMC filter
7.2 Maintenance
Clean cooling channels every 6 months
Check terminal torque annually
Avoid frequent starts/stops (≤ 20 times per day)
Storage temperature: -25°C to +60°C, dry environment
ABB ACS355-01E-02A4-2
Installation and Commissioning Manual
Overview: This manual provides complete instructions for safety, installation, wiring, parameter setting and commissioning of the ACS355-01E-02A4-2 drive (0.37 kW / 0.5 HP, single-phase 200–240 V) for general machinery speed control and energy saving.
1 Safety Instructions (Must Read)
1.1 Electrical Safety
Power-off procedure: Disconnect all power before installation, wiring or maintenance. Wait 5 minutes for internal capacitors to discharge.
Earthing: PE terminal must be reliably earthed (earth resistance ≤ 4 Ω)
Overcurrent protection: Install 10 A MCCB (C-curve) or fuse on input side
Insulation test: Only test motor cables; do NOT apply voltage to the drive itself
1.2 Mechanical Safety
Rotating parts (shaft, coupling, pulley) must be guarded
Mount vertically on solid surface to avoid vibration
Do not modify internal circuits or structures
1.3 Environmental Safety
Operating temperature: 0–40°C (derate 10% at 40–50°C)
습기: 5–95% RH, non-condensing
IP20: must be installed in enclosed cabinet
2 Product Overview and Model Identification
2.1 Model Explanation (ACS355-01E-02A4-2)
| Code | Meaning |
| ACS355 | ABB general machinery drive series |
| 01E | IP20, cabinet-mounted |
| 02A4 | Rated output current 2.4 에이 (40°C) |
| 2 | Single-phase 200–240 V AC, 50/60 헤르츠 |
2.2 Core Specifications
| 목 | 값 |
| Rated power | 0.37 kW (0.5 HP) |
| Input voltage | Single-phase 200–240 V AC (±10%) |
| Output voltage | Three-phase 0–240 V AC |
| Output frequency | 0–500 Hz |
| Overload capacity | 150% for 60 에스, 180% for 2 에스 |
| Cooling | Natural cooling |
| 치수 (W×H×D) | 169×70×135 mm |
| 무게 | 대략. 1.2 kg |
| Order code | 3AUA0000058166 |
3 Installation Procedure
3.1 Preparation
- Unpack and inspect drive for damage
- Choose well-ventilated, dust-free location inside cabinet
- Tools: Phillips screwdriver (PH2), wire stripper, crimping tool, 멀티미터, insulation tape
3.2 Mounting
- Mount vertically on flat metal plate
- Keep ≥ 100 mm above/below, ≥ 50 mm left/right clearance
- Fix with M4 screws, tightening torque: 1.2–1.5 N·m
4 Electrical Wiring
4.1 Terminal Description (ACS355-01E Series)
| Section | Terminal | Description | 배선 |
| Power Circuit | L1/N | Single-phase 200–240 V input | 1.5–2.5 mm² copper |
| PE | Protective earth | ≥ 2.5 mm² copper | |
| U/V/W | 3-phase output to motor | 1.5–2.5 mm² copper | |
| 제어 회로 | DI1–DI3 | Digital inputs | 0.5–1.5 mm², max 50 m |
| AI1/AI2 | Analog inputs (0–10 V / 0–20 mA) | Shielded twisted pair, max 100 m | |
| AO1 | Analog output (0–20 mA) | Shielded twisted pair, max 100 m | |
| +24V/GND | 24 V DC supply (max 100 엄마) | 0.5–1.5 mm² | |
| RS485+/– | 모드버스 RTU | Shielded twisted pair, max 1000 m |
4.2 배선 단계
- Power wiring: L1/N to mains, PE to earth, U/V/W to motor
- Control wiring (Standard macro example):
DI1: Forward (FWD), DI2: Reverse (REV), DI3: Reset
AI1: Speed reference (0–10 V)
- Check torque, insulation, and phase sequence
5 Parameter Settings
5.1 Keypad Functions
▶/■: 시작 / Stop
▲/▼: Adjust value
ENTER: Confirm
ESC: Back
LOC/REM: Local / Remote
5.2 Quick Motor Settings (Group 99)
| 매개변수 | 이름 | Setting | 메모 |
| 9901 | Language | Chinese / English | User choice |
| 9902 | Application macro | 1 (Standard) | General use |
| 9903 | Motor type | 1 (Asynchronous) | Standard induction motor |
| 9904 | Motor rated power | 0.37 kW | From nameplate |
| 9905 | Motor rated voltage | 220/230/240 다섯 | From nameplate |
| 9906 | Motor rated current | Motor nominal | Typically ~2.1 A |
| 9907 | Motor rated frequency | 50/60 헤르츠 | From nameplate |
| 9908 | Motor rated speed | Motor nominal | ~1400–1450 rpm |
| 9909 | Number of motor poles | 4 | Standard for 0.37 kW |
| 9910 | Control mode | 1 (V/f) | Scalar control |
5.3 Common Application Parameters
| Group | 매개변수 | 이름 | Recommended Value |
| 10 | 1001 | Max frequency | 50/60 헤르츠 |
| 1002 | Min frequency | 0 헤르츠 | |
| 20 | 2001 | Acceleration time | 3–10 s |
| 2002 | Deceleration time | 3–10 s | |
| 21 | 2101 | Acc/dec type | 1 (Linear) |
| 40 | 4001 | DI1 function | 1 (FWD) |
| 4002 | DI2 function | 2 (REV) | |
| 4003 | DI3 function | 9 (RESET) | |
| 50 | 5001 | AI1 type | 1 (0–10 V) |
| 5002 | AI1 minimum | 0% | |
| 5003 | AI1 maximum | 100% | |
| 16 | 1607 | Save parameters | 1 |
6 Commissioning Flow
6.1 Pre-Power Check
Correct power and control wiring
Motor and drive area clear
Cabinet ventilation OK
Input voltage: 200–240 V single-phase
6.2 First Power-Up
Close MCCB, display shows REM or LOC
Check for fault codes
Verify Group 99 motor parameters
6.3 Motor Identification (선택 과목)
Set 9910 = 2 (ID Run)
Press ENTER; drive runs motor briefly
Completed when shown COMPLETE
6.4 No-Load Test
Switch to LOCAL
Run at 5 헤르츠, check rotation
Increase to rated frequency, check noise and vibration
6.5 Load Test
Switch to REMOTE
Control speed via AI1
Check output current ≤ 2.4 에이
Adjust acc/dec to avoid overcurrent
Test protection functions
7 문제 해결
7.1 Common Fault Codes
| 잘못 | Description | Cause | Remedy |
| OVERCURRENT | Overcurrent | Motor overload, 단락 | Check load, motor, parameters |
| OVERVOLTAGE | 과전압 | High mains, fast deceleration | 전압을 확인하세요, increase dec time |
| UNDERVOLTAGE | Undervoltage | Low supply, loose connection | Check mains and wiring |
| OVERTEMP | Overheating | High temp, blocked cooling | Improve ventilation, clean heatsink |
| MOTOR OVERLOAD | Motor overload | Excessive load | Check application, 부하를 줄이다 |
| FAULT RESET | Trip reset required | Fault occurred | Fix cause, reset via DI3 or keypad |
7.2 Typical Issues
| Symptom | Cause | 해결책 |
| Motor does not start | Wrong LOC/REM, missing DI signal | Check mode, wiring and parameters |
| Unstable speed | AI noise, poor parameters | Use shielded cable, adjust filtering |
| Communication failure | Wrong settings, bad wiring | Check Group 98, RS485, termination |
8 Maintenance
8.1 Routine Maintenance
Clean cooling channels every 6 months
Check terminal torque annually
Log operating current and temperature
8.2 Long-Term Storage
Temperature: -25°C to +60°C
Dry, ventilated environment
Power on for 1 hour every 6 months
9 Appendix: Options and Replacements
9.1 Recommended Options
Braking resistor: 100 Ω / 50 여
EMC filter
RS485 Modbus RTU module
Shielded cable for control wiring
9.2 Cross-Brand Alternatives (0.37 kW, 1-phase 220 다섯, IP20)
| Brand | 모델 | Matching Features |
| 슈나이더 | ATV12HU04M2 | 0.37 kW, 1-phase 220 다섯, IP20 |
| 지멘스 | V20 6SL3210-5BB12-5UV1 | 0.37 kW, 1-phase 220 다섯, IP20 |
| 친트 | NVF2-0.37/2 | 0.37 kW, 1-phase 220 다섯, IP20 |
| 씨줄 | ACS150-01E-02A4-2 | Direct same-power replacement |
Manual Version: V1.0 (based on ABB official ACS355 manual, adapted for ACS355-01E-02A4-2)
Effective Date: February 2026
Copyright: ABB Group, 모든 권리 보유
접촉기,회로 차단기,태양광 인버터,전기 계량기,태양 전지






















NH42-63-318x560.png)