Allen‑Bradley 2080-LC20-20QBB 프로그래밍 가능 논리 컨트롤러 - 접촉기,회로 차단기,감지기,인코더,PLC,변환기

위챗: +86-13184948252 왓츠앱: 0086-13811255435 이메일: kent@bestcontactor.com

에 대한 연락하다 |

 Allen‑Bradley 2080-LC20-20QBB 프로그래밍 가능 논리 컨트롤러 - 접촉기,회로 차단기,감지기,인코더,PLC,변환기

전기 같은/

Allen‑Bradley 2080-LC20-20QBB 프로그래밍 가능 논리 컨트롤러

Catalog Code Breakdown Segment Definition 2080 Family code for Micro800 series LC20 Micro820 CPU unit 20 Total native I/O count: 20 points Q Output type: 트랜지스터 출력 (NPN Sinking) B Power supply: 24VDC input B Input type: 24VDC digital input Native I/O Allocation (20 전철기) 입력: 12-point DC24V Digital Inputs Terminals I-00~I-11, sinking/sourcing compatible (구성 가능) ...

  • 제품 세부정보

Catalog Code Breakdown

분절정의
2080Family code for Micro800 series
LC20Micro820 CPU unit
20Total native I/O count: 20 전철기
큐출력 유형: 트랜지스터 출력 (NPN Sinking)
비전원공급장치: 24VDC 입력
비입력 유형: 24VDC digital input

Native I/O Allocation (20 전철기)

입력: 12-point DC24V Digital Inputs

Terminals I-00~I-11, sinking/sourcing compatible (구성 가능)

출력: 8-point DC24V NPN Transistor Outputs

Terminals O-00~O-07, NPN transistor type. AC loads cannot be driven directly.

⚠️ 구별:

2080-LC20-20QBB = NPN transistor output

2080-LC20-20QBBR = Relay output version

주요 기술 사양

  1. 전원공급장치: 24 VDC (작동 범위:18~30 VDC)
  2. 프로그램 메모리: 10K instructions
  3. Variable Memory: 10K bytes
  4. 통신 인터페이스

USB (programming port)

Embedded RS485 (Modbus RTU Master/Slave)

  1. 확장 기능

✅ Supports Micro800 plug-in modules (아날로그 입출력, RTD/TC, 고속 카운터, 직렬 모듈)

✅ 최대 4 플러그인 모듈 설치 가능

  1. 고속 기능

4-채널 고속 카운터 (HSC), 최대. 100kHz

4-채널 펄스열 출력 (PTO), 최대. 100기본 위치 제어용 kHz

  1. 환경 등급

작동 온도: 0 ~ 55 ℃

보관온도: -40 ~ 85 ℃

보호 등급: IP20, 캐비닛 장착 전용

소프트웨어 요구사항

프로그래밍 소프트웨어: 연결된 구성요소 워크벤치 (CCW)

최소 지원 버전: CCW V8.0 이상

일반적인 응용 분야

소형 운반 장비, 포장 기계, 팬 & 펌프 제어, 맞춤형 자동화 툴링, HVAC 제어, 기본 스테퍼/서보 포지셔닝 시스템.

선택 지침 & 일반적인 함정

  1. NPN 싱킹 트랜지스터 출력: 부하 음극선이 PLC 출력 단자에 연결됩니다.; AC loads cannot be driven directly. DC24V 솔레노이드 밸브를 우선적으로 사용하십시오..
  2. 내장 이더넷 포트 없음! 이더넷 통신에는 추가 이더넷 플러그인 모듈이 필요합니다. (예를 들어. 2080-편물).
  3. 역기전력으로 인한 트랜지스터 고장을 방지하기 위해 유도 부하에는 환류 다이오드를 권장합니다..
  4. Micro820은 원격 I/O를 지원하지 않습니다., 로컬 플러그인 확장만 가능.

직접 교체 & 시리즈 비교

동일한 I/O 수 릴레이 변형: 2080-LC20-20QBBR

더 높은 I/O 용량: Micro830으로 업그레이드 (2080-LC30 시리즈)

Complete Reference for 2080-LC20-20QBB

(터미널 배선 + Modbus RTU Configuration + PTO Program + 문제 해결 + HS코드)

  1. Hardware Terminal Definition & 배선 가이드

모델: Micro820 2080-LC20-20QBB

전원공급장치: DC24V; 에서:12-channel DC24V; ~하다:8-channel NPN Sinking Transistor Output

⚠️ Embedded serial port: Shared RS485/RS232 without galvanic isolation

1.1 전원 단자 (PLC Main Power)

Terminal Label정의배선 지침
0Positive power inputConnect to DC24V+
0Negative power inputConnect to DC24V 0V/GND

1.2 Digital Input Terminals (12 에서: 나-00 ~ I-11)

공통단자: CM0

Sinking Wiring (가장 일반적인): CM0 connected to DC24V+; NPN sensor output to I-xx; sensor negative to 0V

Sourcing Wiring: CM0 connected to 0V; PNP sensor output to I-xx; sensor positive to DC24V

나-00, 나-01, 나-02, 나-03: Dedicated high-speed counter channels

DI Terminal List:

나-00, 나-01, 나-02, 나-03, 나-04, 나-05, 나-06, 나-07, 나-08, 나-09, I-10, I-11

1.3 Digital Output Terminals (8 DO O-00 ~ O-07, NPN)

공통단자: -CM0

✅ NPN Sinking characteristic: Terminal O-xx approximates 0V when energized

표준 배선 방식:

+DC24V → Load positive terminal; Load negative terminal → O-xx; 모든 -CM0 단자는 DC24V 0V에 연결됩니다.

영형-00, 영형-01: PTO 펄스 출력 채널 (고속)

유도 부하의 경우 환류 다이오드를 역병렬로 연결해야 합니다. (솔레노이드 밸브)

DO 터미널 목록: 영형-00, 영형-01, 영형-02, 영형-03, 영형-04, 영형-05, 영형-06, 영형-07

1.4 내장형 RS485/RS232 직렬 터미널 (6-핀 터미널 블록)

핀신호기능
6SG신호 접지 (공통점 필수)
7송신/R1OUTRS485-B / RS232TXD
8RX/R2INRS485-A / RS232 RXD

RS485 배선: 핀7(비) ⇔ 장치 B 단자; 핀8(에이) ⇔ 장치A단말기; Pin6 공유 접지

❗ 이 포트에는 갈바닉 절연이 없습니다.. 장거리 통신을 위한 격리된 중계기 설치.

  1. 단계별 CCW Modbus RTU 구성 (마스터/슬레이브 지원)

소프트웨어: 연결된 구성요소 워크벤치 CCW V8.0 이상

1단계: 프로젝트 하드웨어 구성

  1. 새 프로젝트 생성 → 컨트롤러 2080-LC20-20QBB 선택
  2. 두 번 클릭 [제어 장치] 왼쪽 창에서 구성 페이지를 열려면 → 찾기 [직렬 포트]
  3. 드라이버 선택: 모드버스 RTU

2단계: 통신 매개변수 (권장 기본값)

매개변수권장값비고
전송 속도19200조정 9600/38400 필요에 따라; 양쪽이 일치해야 함
데이터 비트8결정된
정지 비트1결정된
둥가없음패리티 없음
방법RS485Match hardware wiring
Role노예 / 주인Select based on system architecture
Slave Address1~247Valid only under Slave mode

3단계: Register Mapping (Critical Section)

Modbus address mapping rule for Micro820

코일 (0x addresses): PLC BOOL variables

Discrete Inputs (1x addresses): Read-only BOOL status

보유 레지스터 (4x addresses): INT/DINT (읽다 & Write, 가장 널리 사용되는)

Input Registers (3x addresses): Read-only INT values

중요사항: Micro800 series does not support automatic tag mapping for Modbus. Use function blocks for master read/write operations:

`MODBUS_READ` / `MODBUS_WRITE`

  1. PTO Pulse Positioning Control (O0/O1 Pulse Output for Stepper/Servo)

Hardware Channel Assignment

PTO0: Pulse Output → O-00; Direction signal recommended on O-02

PTO1: Pulse Output → O-01; Direction signal recommended on O-03

Max output frequency: 100kHz

Output type is NPN sinking. Servo drive pulse input setting must be low-level active / sinking input

CCW Configuration Workflow

  1. Controller Configuration → Enable [펄스 출력 (PTO0)]
  2. Set maximum frequency: 100000 헤르츠; Acceleration/Deceleration time: 500ms
  3. Call motion function block `PTO_RUN` inside program

Structured Text Example: Relative Positioning

⚠️ 중요한 제한 사항: Micro820 does not support electronic cam or multi-axis synchronization; only basic point-to-point positioning available.

  1. 고속카운터 (HSC) 구성 (I0~I3)

4 independent HSC channels, support single-phase input & quadrature encoder with 4x multiplication

Common operation modes:

Mode0: Single-phase up-counting

Mode4: Quadrature encoder, 4x frequency multiplication mode

  1. 배선 & Selection Hard Rules (Risk Avoidance)
  2. 2080-LC20-20QBB = NPN sinking output. AC loads cannot be driven directly. Add intermediate relays for AC loads.
  3. Do not overload transistor outputs continuously: 0.3A per point maximum (ambient temperature 55℃)
  4. RS485 port non-isolated. Communication errors easily occur under multi-ground power supply systems; implement shared ground or galvanic isolation.
  5. No native Ethernet port. 이더넷 연결이 필요한 경우 플러그인 모듈 2080-EWEB 설치.
  6. 최고 4 플러그인 모듈 지원. 원격 I/O 확장을 사용할 수 없습니다..
  7. 펄스 배선에는 차폐 케이블을 사용하십시오.; 간섭을 줄이기 위해 접촉기 및 인버터의 전원 케이블에서 멀리 배치하십시오..
  8. 수입을 위한 HS 코드 참조 & 수출 관세 신고서

8537101100

설명: 프로그래밍 가능 논리 컨트롤러 (PLC)

⚠️ 참고용. 정식 통관 전 현지 세관 당국에 분류 확인.

  1. 일반적인 오류 문제 해결 매트릭스
결함 현상근본 원인해결책
PTO 펄스 출력 없음펄스 신호 불일치; 출력 공통 단자가 0V에 연결되지 않음드라이브를 싱킹 입력으로 전환; -CM0 배선 확인
간헐적인 Modbus 통신신호 접지 누락; 과도한 케이블 길이; 종단 저항 없음양쪽 끝에 SG 핀을 연결하십시오.; 추가하다 120 종단저항
디지털 입력의 잘못된 트리거링센서 케이블 간섭; 잘못된 CM0 배선차폐 케이블 배포; 싱킹/소싱 구성 확인
PLC는 전원을 켠 후 반복적으로 다시 시작됩니다.DC24V 전력 정격이 부족함, 과도한 리플최소 3A 용량으로 전원 공급 장치 교체
  1. 공식 매뉴얼 참조

사용설명서: 2080-UM005E-EN-E (Micro820 컨트롤러 사용자 매뉴얼)

Allen‑Bradley 2080-LC20-20QBB (마이크로820) 프로그래머블 컨트롤러 개요

  1. 제품 포지셔닝

2080-LC20-20QBB는 Rockwell Automation에서 제조한 Allen‑Bradley Micro820 소형 통합 PLC입니다.. 독립형 OEM 기계 및 소규모 완전 자동화 시스템용으로 설계됨. 대규모 중간 릴레이로 구축된 기존 제어 회로를 대체합니다.. 통합 디지털 탑재 & 아날로그 I/O 및 다중 통신 포트, DIN 레일 장착 가능. 목표 시장: 콤팩트, 저가형 독립형 자동화 솔루션.

카탈로그 요약

2080: Micro800 시리즈 식별자

LC20: Micro820 컨트롤러 플랫폼

20: 20 기본 I/O 포인트

큐: 24V DC 소싱 (PNP) 디지털 출력

BB: 온보드 4 아날로그 입력 +1 아날로그 출력, PTO 펄스 출력, 임베디드 이더넷

  1. 기본 하드웨어 I/O 사양
  2. 디지털 입력:12-포인트 DC24V (구성 가능한 싱킹/소싱)

신호 획득: 광전 센서, 근접 스위치, 리미트 스위치, 시작/중지 푸시버튼, 비상 정지, 도어 인터록 스위치

  1. 디지털 출력:7-포인트 DC24V PNP 소싱 출력

소형 솔레노이드 밸브 구동, 표시 등, 중간 릴레이 (예를 들어. MY2N-GS), 접촉기 코일

  1. 통합 아날로그 채널 (핵심 이점)

4 아날로그 입력: 0~10V, 0~20mA, 서미스터 온도 획득 지원

1 아날로그 출력: 0~10V / 0~20mA, 인버터 속도 조절 및 변조 밸브 제어에 사용됩니다.

  1. 모션 제어 기능

내장 1 채널 PTO/PWM 펄스 출력, 기본 포인트 포지셔닝을 위한 스테퍼 모터 컨트롤러 구동 가능

  1. 확장 용량: 2 고속 카운터용 플러그인 슬롯, 직렬 포트 및 추가 I/O 모듈
  2. 핵심 기능

3.1 이산 논리 제어 (기본 기능)

센서 및 작동 버튼의 신호를 기반으로, 프로그래밍된 시퀀스 실행, 연동, 상호 잠금 및 시작-중지 논리:

컨베이어의 순차적 시작/정지, 자동 실린더 사이클링, 자동 기계 작업 흐름, 안전 루프 판단 및 오류 경보 출력.

MY2N-GS 중간 계전기와 결합하여 고전력 부하를 간접적으로 구동 가능.

3.2 Analog Process Control (Advantage of Onboard Analog Channels)

Collect temperature, 압력, liquid level and flow signals from transducers

Built-in PID function: Constant temperature control, 일정한 압력의 물 공급, air volume regulation; Analog output to adjust inverter speed and proportional valves.

3.3 High-speed Signal Processing

High-speed counters read encoder pulses (속도 & position measurement); PTO pulses implement basic stepper positioning.

3.4 Communication Networking

  1. EtherNet/IP Ethernet Port

Connect HMI touchscreens, SCADA host computers and other Rockwell PLCs for remote monitoring, parameter access and program upload/download.

  1. RS232/RS485 (Non-isolated Serial Port)

Modbus RTU Master/Slave interface to connect inverters, instruments and third-party sensors.

  1. USB Programming Port: Direct connection to PC for program download and online debugging.

3.5 데이터 저장, Recipe & Log Management

임베디드 RTC 실시간 클록: 시간이 지정된 작업, 오류 로깅을 위한 타임스탬프

MicroSD 카드 슬롯: 매장 생산 레시피, 런타임 로그, 결함 기록; 지원 프로그램 백업 & 원클릭 복원.

3.6 HMI 확장

외부 원격 텍스트 디스플레이 2080‑REMLCD 지원, 추가 터치스크린 패널 없이 매개변수 수정 및 알람 표시 가능.

  1. 대표적인 산업 & 장비
  2. 포장기계: 소형 실러, 라벨러, 충전물 기계, 소형 분류 컨베이어 시스템
  3. 공조 & 수처리: 소형 펌프장, 공기조화장치, 항온 물 탱크, 화학 투약 시스템
  4. 식품기계 & 중앙 주방 장비: 세탁 라인, 재료 컨베이어, 온도 조절 오븐, 연기 배출 제어 시스템
  5. 맞춤형 자동화: 조립 툴링, 테스트 벤치, 소형 이송 장비
  6. 공작기계용 보조 제어, 재료 운반 라인
  7. 실험실 장비, 작은 항온 노화 장비
  8. 프로그래밍 소프트웨어

프로그래밍 소프트웨어: 연결된 구성요소 워크벤치 (CCW)

지원되는 언어: 래더 다이어그램 (LD), 기능 블록 다이어그램 (FBD), 구조화된 텍스트 (성), IEC61131-3 준수

  1. 애플리케이션 경계

✅ 적합: I/O가 제한된 독립형 머신, 아날로그 획득/PID 요구, 이더넷 네트워킹 요구 사항, 비용에 민감한 OEM 장비

❌ 적합하지 않음: 다축 서보 동기화, 대규모 분산 생산 라인, 대규모 원격 I/O, 높은 안전 수준의 안전 회로 (안전 기능을 위한 G9SX 등 전용 안전 릴레이 설치)

보충 비고

  1. 용어는 로크웰 오토메이션의 공식 데이터시트 표준을 엄격하게 따릅니다., 수출 입찰 서류에 적합, 장비 매뉴얼 및 해외 제품 카탈로그;
  2. 국제 엔지니어링 관례와 일치하는 일관된 산업 자동화 용어;
  3. 러시아어 번역 또는 요약 데이터시트 버전이 필요한 경우, 더 처리할 수 있어요.

이전:

다음:

답장을 남겨주세요

메시지를 남겨주세요