The Chint NXB63-C6+AX-X1 회로 차단기 is a compact protective device suitable for low-voltage power distribution systems, composed of the NXB63-C6 circuit breaker body and the AX-X1 alarm contact accessory. Below is a detailed analysis of key information:
- Model Analysis and Core Parameters
- NXB63-C6 Circuit Breaker Body나이프 스위치 퓨즈 코어 RT-3 (NT3) DC440V
Series and Function: The NXB-63 is a miniature circuit breaker (MCB) from Chint’s Kunlun series, suitable for AC circuits with 50Hz/60Hz frequency and a rated voltage of 400VAC, 과부하 및 단락 보호 제공.
정격 전류 및 트립 특성: C6 indicates a rated current of 6A, with a C-type trip curve (trip current: 5-10 정격 전류의 배), suitable for resistive loads such as lighting and sockets.
차단 용량: Standard breaking capacity is 6kA, with some models reaching 10kA (예를 들어, NXB-63 2P C10), which should be selected based on the circuit’s short-circuit current. 친트 중간 릴레이 JZX-22F/4Z(디) 24VDC
Pole Count and Dimensions: Supports multiple pole counts (1피, 2피, 3피), with a width of 18mm per pole, installable on 35mm rails.
- AX-X1 Alarm Contact AccessoryChint NXR 시리즈 열 과부하 계전기 가격
기능: When the circuit breaker trips due to overload, 단락, or other faults, the AX-X1 outputs alarm signals via normally open (아니요)/평상시 닫혀 있음 (NC) 콘택트 렌즈, which can be connected to monitoring systems or indicator lights. CHINT 회로 차단기 가격
전기적 매개변수: Rated operating voltage covers 115V to 400V (AC/DC), with a contact capacity of 3A (AC230V), compatible with various control circuits.
설치 방법: Directly pluggable on the right side of the circuit breaker, removable without tools, and does not affect the main breaker’s function.
- 응용 시나리오 및 선택 권장 사항
- 일반적인 응용 분야
주거용 및 상업용 배전: Used for lighting circuits (6A는 짐을 싣는다), small appliance sockets, 등., with AX-X1 for fault warning.
산업 제어: As branch circuit protection in automated equipment, combined with AX-X1 signals for remote monitoring.
New Energy Fields: Suitable for the output side of photovoltaic inverters (DC compatibility must be confirmed), but models explicitly marked with DC parameters are preferred.
- 주요 선택 기준
현재 매칭: Select the rated current based on the load current (예를 들어, 6A corresponds to ≤1.32kW loads) to avoid false tripping due to overload.
차단 용량: Must be greater than the circuit’s expected short-circuit current (예를 들어, typically 6kA for residential distribution; 10kA models for high short-circuit risk scenarios like industrial use).
액세서리 호환성: AX-X1 is only suitable for the NXB-63 series; other series (예를 들어, DZ47) require corresponding accessories (예를 들어, 도끼-01).
III. 설치 및 사용상의 주의사항
- 기계적인 설치
레일 장착: The circuit breaker must be vertically installed on a standard 35mm rail, ensuring the卡扣 (clips) are fully engaged to prevent looseness.
배선 요구 사항: The incoming end connects to the power supply side, and the outgoing end connects to the load side. The wire cross-sectional area must match the current (1.5mm² is recommended for 6A).
액세서리 설치: AX-X1 should be inserted into the right-side slot with the circuit breaker in the closed state, ensuring contact alignment, and checked for stability after installation.
- Electrical Connections
전압 매칭: The circuit breaker’s rated voltage is 400VAC; it is strictly prohibited for DC systems like DC440V (special DC circuit breakers must be selected for photovoltaic combiner boxes).
Alarm Signal Circuit: AX-X1 contacts must be connected in series to the alarm circuit (예를 들어, indicator lights or PLC input modules) to ensure reliable signal transmission.
- 환경 조건
온도 범위: -5°C~40°C (장기), with short-term tolerance up to -35°C to 70°C. Derate the current in high-temperature environments (reduce current by 5% for every 10°C increase).
고도 제한: 2000미터 이하. Special models or derating are required for high-altitude areas (insulation strength decreases by 8% 모든 1000 미터 증가).
- 인증 및 규정 준수
- 국내인증
– 중국 CCC 인증 (인증서 번호. 2020980307001645), GB와 호환 10963.1 표준, suitable for the domestic market.
– The packaging and product body bear CCC marks, model numbers, rated parameters, 등., which can be verified for authenticity on Chint’s official website.
- 국제 시장 적응
북미 시장: Not UL-certified; compatible models (예를 들어, Siemens 5SJ6 series) or customized versions must be selected.
유럽 시장: No CE certification; products compliant with EN 60898 표준 (예를 들어, ABB iC65) are recommended.
- 유지 관리 및 오류 처리
- 정기 유지 관리
정기점검: Check for contact oxidation and loose terminals every 6 개월, and clean surface dust.
기능 테스트: Simulate overload tripping via the test button annually to verify the circuit breaker’s normal operation.
- 결함 문제 해결
빈번한 트립: Check if the load exceeds the rated current, if there is a short circuit, or if the circuit breaker is aged and needs replacement.
Abnormal Alarm Signals: Inspect for poor contact in AX-X1 or wiring breaks, and replace the accessory if necessary.
- Alternative Solutions and Emergency Procurement
- 동등한 모델
국내 대안: Delixi CDB6-63 C6, Tianzheng TGB1-63 C6 (ensure matching pole count and breaking capacity).
Imported Alternatives: Schneider C65N C6, ABB S201-C6 (note installation dimensions; some are 17.5mm per pole).
- Emergency Handling
– If AX-X1 is out of stock, temporarily use auxiliary contacts (예를 들어, 도끼-01) as a substitute, but manual reset of alarm signals is required.
– In case of circuit breaker body failure, temporarily use a same-specification fuse (예를 들어, RT16-3 NT3 6A) as a transition, but replace it as soon as possible.
Ⅶ. Procurement and After-Sales Service
- 채널 선택
국제적인: Procure via agents (왓츠앱: +86-13811255435), and confirm delivery lead times in advance.
- 기술지원
– Technical hotline (왓츠앱: +86-13811255435) for inquiries on parameter matching and installation guidance.
– 대량 구매의 경우, request type test reports (예를 들어, short-circuit breaking test data) from suppliers.
요약: Procurement Decision Checklist
| 검사 항목 | Compliance Criteria |
| 모델 식별 | Circuit breaker: NXB63-C6; 종범: AX-X1, with clear parameters and CCC marks on both body and accessory |
| 차단 용량 | ≥ Circuit’s expected short-circuit current (예를 들어, 6kA for residential, 10kA for industrial) |
| 액세서리 호환성 | AX-X1 clips match the right-side slot of the circuit breaker, with aligned and secure contacts |
| 인증마크 | 국내의: CCC; Export: Additional UL/CE certification required |
| Packaging and Transportation | Original factory sealed packaging, shock-proof foam, and logistics providers qualified for electronic component transportation |
위의 분석을 통해, the NXB63-C6+AX-X1 combination effectively meets the protection and monitoring needs of low-voltage power distribution systems. Strictly verify parameters and certifications during procurement to ensure system reliability.
The Chint NXB63-C6+AX-X1 circuit breaker is a Miniature Circuit Breaker (MCB) commonly used in low-voltage power distribution systems, 과부하 및 단락 보호 제공. 그만큼 “+AX-X1” likely indicates the inclusion of auxiliary contact (도끼) 부속품. Below is a general guide to its installation method and precautions (always refer to the product manual for specifics):
- 설치 전 준비
- Confirm Product Specifications
– Ensure the circuit breaker model matches requirements (C6 denotes a rated current of 6A, suitable for low-current circuits like lighting).
– The AX-X1 accessory is typically an auxiliary contact for remote signal feedback (예를 들어, connecting to alarm or control systems); verify its function and wiring method.
- Tools and Materials
– Tools needed: 드라이버 ( Phillips or flathead), 와이어 스트리퍼, 멀티미터, rail installation tool (필요한 경우).
– 재료: 표준 35mm DIN 레일 (for mounting the circuit breaker), 전선 (selected by load current rating).
- Safety Power Disconnection
– Always disconnect the upstream power supply before installation to ensure the circuit is de-energized and avoid electric shock hazards.
- 설치 단계
- 레일 장착 (Main Circuit Breaker)
Rail Type: Use a standard 35mm DIN rail (common in distribution panels).
장착 방법:
- Align the clips at the bottom of the circuit breaker with the rail, press down firmly until a “딸깍 하는 소리” is heard to confirm secure attachment.
- To remove, use a screwdriver or specialized tool to press the clip on the side of the circuit breaker and pull upward.
- 액세서리 설치 (AX-X1 Auxiliary Contact)
설치 위치: Auxiliary contacts are typically mounted on the right side of the main circuit breaker (some models may support left or rear mounting; 설명서를 참조하세요).
장착 방법:
- Align the卡槽 (슬롯) of the auxiliary contact with the interface of the main circuit breaker, push horizontally to fix (may require screws or clips for locking).
- Ensure the accessory is tightly connected to the main circuit breaker without looseness.
- Wiring Operations
주회로 배선 (Circuit Breaker Body):
Incoming Terminals (맨 위): Connect to the power supply side (usually live wire L and neutral wire N; note that the neutral wire may need to be connected via a terminal block, depending on whether the circuit breaker has a neutral terminal).
Outgoing Terminals (맨 아래): Connect to the load side (예를 들어, 램프, 소켓).
지침:
– Wire cross-sectional area should match the current (1.5mm² or 2.5mm² copper wire is recommended for 6A current).
– Strip wires to an appropriate length to avoid short circuits; ensure terminal screws are tightened securely.
Accessory Wiring (AX-X1 Auxiliary Contact):
– Auxiliary contacts typically have 2-4 터미널 (예를 들어, NO 평상시 열림, NC normally closed) for connecting control circuits (예를 들어, to energy meters, alarm systems, or PLCs).
– Connect wires to the corresponding terminals as needed (marked such as “1-2” for normally open, “3-4” for normally closed), and tighten the screws.
III. Post-Installation Inspection and Testing
- 육안검사
– Confirm the circuit breaker and accessories are firmly installed without tilting or looseness; ensure no exposed copper wires and tight terminal screws.
- 기능 테스트
– Close the upstream power supply and check if the circuit breaker indicator (가능하다면) is normal.
– Manually switch the circuit breaker on and off to test smooth operation and whether auxiliary contacts actuate synchronously (use a multimeter to measure contact continuity).
– Simulate overload or short-circuit conditions (exercise caution) to test if the circuit breaker trips promptly for protection.
- Safety Verification
– Use a multimeter to measure line insulation resistance to ensure no grounding or short-circuit faults.
– Check that the distribution panel is reliably grounded and complies with electrical installation codes.
- 지침
- Polarity and Neutral Handling
– Single-pole circuit breakers (1피) usually connect only the live wire; the neutral wire must be connected via the distribution panel’s neutral terminal block. For 1P+N circuit breakers, distinguish the incoming direction of the live wire (엘) 그리고 중성선 (N) (the N terminal is typically a fixed hole and not interruptible).
- 환경 요구 사항
– Install in dry, ventilated areas free of corrosive gases, avoiding high-temperature or humid environments.
– Leave sufficient space in the distribution panel to ensure good heat dissipation.
- 전문적인 운영
– If unfamiliar with electrical installation, consult a licensed electrician to ensure compliance with local electrical codes (예를 들어, China’s GB standards).
We hope this information helps! Always prioritize safety and follow proper procedures during installation.