W2E: AC axial fan, external rotor construction
250: Nominal impeller diameter 250 mm; overall dimensions 280 × 280 × 80 mm
HL06: Motor structure, winding version and mounting frame form
01: Variant revision number
- 핵심 전기 & 기계 사양
| 목 | 매개변수 |
| 모델 | W2E250-HL06-01 |
| 전원공급장치 | AC 230V 50/60Hz |
| 입력 전원 | P ≈ 165 여 |
| 정격전류 | I ≈ 0.75 에이 |
| 속도 | ≒ 2600 rpm |
| 맥스. Air Flow | ≒ 1650 m³/h |
| 맥스. Static Pressure | ≒ 180 아빠 |
| Impeller Diameter | 250 mm |
| Overall Size | 280(여) × 280(시간) × 80(디) mm |
| 장착 구멍 간격 | 254 × 254 mm (standard four-point mounting) |
| 베어링 종류 | 볼베어링 (double ball bearing) |
| Rotation Direction | Clockwise (CW) viewed from air inlet side |
| 콘센트 유형 | Direct lead wire (without terminal block) |
| 보호 등급 | IP20 (internal rotor; direct water spray prohibited) |
| 작동 온도 | -20 ℃ ~ +60 ℃ |
> ⚠️ 중요한 차이점: Two models with identical 280×80 outline are easily confused
> W2E250-HL06-01 (230다섯) ≠ W2E250-HL06-05 (115V version). Voltage mixing is forbidden.
- 구조 & 형질
- External rotor AC motor: Classic ebm axial fan with metal frame for general industrial cooling;
- Metal impeller + galvanized steel frame, 진동 방지, widely used for forced cabinet ventilation;
- No built-in thermal protection (external thermostat optional for some batches); sustained power supply under locked rotor condition will burn windings;
- Avoid frequent full-voltage start-stop operation over long periods. If speed regulation is required, use phase-angle speed controllers. Ordinary voltage regulators are not recommended.
- 일반적인 애플리케이션 시나리오
Cooling for frequency converters and high-power servo control cabinets
UPS and industrial uninterruptible power supply cabinets
LV/MV electrical cabinets, air conditioning units and industrial oven ventilation
Cooling for welding equipment and test equipment enclosures
- 대체 옵션 (Procurement Alternatives)
직접 OEM 교체
W2E250-HL06-01 (standard stock model)
Equivalent model within series: W2E250-HL06-C01 (new part number, 동일한 성능, commonly used as upgraded replacement)
Domestic Compatible Substitute (280×280×80 AC230V)
국내의 28080 AC axial fans can be selected with the following requirements:
Double ball bearing, rated power ≥150W, comparable air flow & static pressure, matching mounting hole pitch of 254 mm.
- 문제 해결 지침
- Fan fails to start when powered on: Measure 230V input; check broken wires; open/short motor windings; seized bearing
- 비정상적인 소음 & 진동: Worn bearings, unbalanced impeller due to dust accumulation, missing shock absorbers during installation
- Overheating during operation: Blocked air intake, continuous high backpressure operation, excessive deviation from rated 230V supply
Upon request, 나는 제공할 수 있다:
✅ Text version of standard installation dimension drawing
✅ Brief description of airflow-static pressure characteristic curve
✅ Reference winding resistance values
✅ Recommended matching speed controller models
Speed Controller Selection Guide for W2E250-HL06-01 (AC230V, 0.75에이)
⚠️ Critical Note: This fan is a single-phase AC external rotor fan and must be driven by a [Phase-Angle (사이리스터) Speed Controller]; autotransformer regulators and frequency converters are prohibited!
Fan rated current: 0.75에이, select controller with minimum 1.3 times current margin.
- ebm-papst Original Matching Units (Optimal Compatibility, Superior EMC Performance)
REE Series 230VAC Stepless Phase-Angle Speed Controllers
| 모델 | 맥스. Continuous Current | Supported Fan Quantity | Recommendation Level | 설명 |
| REE10 | 1.0에이 | 1 unit W2E250-HL06-01 | ⭐⭐⭐⭐⭐ First Choice | Perfect match for single fan, built-in power switch, adjustable minimum speed, compatible with 2-wire / 3-와이어 배선 |
| REE30 | 3.0에이 | 최대 3 units in parallel | ⭐⭐⭐⭐ | Multi-fan solution with sufficient current margin |
| REE50 | 5.0에이 | 최대 5 units in parallel | ⭐⭐⭐ | Central control for multiple fans |
> 메모: REE10 is the standard original matching model, preferred for overseas & industrial projects; longer lead time and higher cost are disadvantages.
- 대체 솔루션 (Domestic Industrial Phase-Angle Controllers, Widely Used for Cabinets)
1) Manual Knob Type (Local Adjustment)
일반 모델: ST-1、FS-02、FSC-1A
요구사항: AC220/230V, continuous current ≥1A, thyristor phase-angle regulation, compatible with single-phase AC axial fans.
2) Automatic Temperature Control Type (Recommended for Constant-Temp Cabinet Cooling)
Equipped with NTC temperature probe to adjust speed automatically according to temperature:
Domestic Models: FSC-T1、JK-1A (230다섯, 1에이)
- Prohibited Speed Control Solutions (일반적인 함정)
- ❌ Frequency Converter: Direct drive of single-phase AC fan will likely burn windings;
- ❌ Ordinary Autotransformer Regulator: Insufficient low-speed torque and severe overheating;
- ❌ DC 0–10V Signal Controller: Only applicable to EC fans; incompatible with this AC fan;
- ❌ AC PWM Chopper Module: Severe harmonic distortion, causing fan noise and vibration.
- Brief Wiring Instruction (REE10)
- 전원 입력: L 연결, N to 230V mains supply;
- 산출: Connect to two power leads of the fan;
- Internal trimmer for minimum startup speed adjustment (to avoid startup failure at low speed);
- Reliable PE earthing is mandatory.
- Quick Solution Recommendation
Single fan, export equipment / high-standard cabinet: Select REE10 directly
Domestic project, 비용 통제: Adopt domestic 1A phase-angle fan speed controller; choose variant with temperature probe if automatic temperature regulation is required.
Typical Application Scenarios of ebm-papst W2E250-HL06-01 (28080 AC230V Axial Fan)
Core fan features: 230V AC external rotor design, high airflow, moderate static pressure, metal frame, double ball bearings. Suitable for long-term continuous forced cooling in systems with certain duct resistance.
- 힘 & Electrical Industry (가장 일반적인 응용 프로그램)
- Cooling for High-Power Frequency Converter Cabinets
Exhaust mounted on top or side of converter cabinets to dissipate heat from power modules and rectifiers. Handles high internal temperature in enclosed cabinets and overcomes airflow resistance from filter screens. Widely matched with ABB, 슈나이더, Inovance high-power inverters.
- UPS Uninterruptible Power Supply & High-Frequency Switch Power Supply Cabinets
Ventilation for power components and battery compartments; industrial-grade UPS equipment requires long service life and high reliability.
- LV/MV Complete Switchgear & Reactive Power Compensation Cabinets
Forced convection cooling for capacitor and reactor cabinets to prevent capacitor overheating and bulging; ventilation for indoor and outdoor high-voltage control cabinets.
- DC Panels & PCS Energy Storage Converter Cabinets
Cooling for commercial energy storage enclosures under 24/7 지속적인 작동.
- 산업용 장비 & Automation Sector
- Welding Equipment (Resistance Welder, TIG Welder, Plasma Cutter)
Cooling for main transformers and rectifier modules. Metal impeller offers better durability than plastic alternatives in dusty welding workshops.
- Cooling for Control Systems of Injection Molding & Extrusion Machines
Ventilation for machine tool electrical cabinets and servo drive enclosures; suitable for high ambient temperature in rubber & plastic workshops.
- Electrical Cabinets for Laser Equipment & Plasma Cutting Machines
Heat dissipation for laser power supplies and drive units; continuous production requires highly stable fans.
- Test Instruments & Aging Test Equipment
Circulation ventilation for electronic loads and power aging racks; air circulation inside aging chambers.
III. 공조, Drying & Cabinet Air Conditioning
- Condenser Cooling for Small Industrial Packaged Units & Cabinet Air Conditioners
Cooling fan for external condenser of cabinet air conditioners.
- Air Circulation for Small Ovens & Constant-Temperature Chambers
Internal airflow circulation in medium-low temperature ovens (ambient temperature ≤60℃, must not exceed fan temperature rating).
- Purification Equipment & Small Dust Removal Units
Exhaust for simple dust filtration and waste gas treatment enclosures, capable of overcoming airflow resistance of primary filters.
- 철도 운송 & Special Equipment
- Cooling for Auxiliary Electrical Cabinets on Locomotives
Ventilation for auxiliary converter cabinets on rail vehicles (메모: Shock absorbers are recommended to adapt to vibration conditions).
- Electrical Cabinets for Port Construction Machinery
Outdoor ventilation for high-power control cabinets of container cranes and loaders.
- 에너지신산업
- Cooling for Centralized PV Inverter Enclosures
Exhaust ventilation inside power cavities of large centralized inverters.
- Control Cabinets for Charging Pile Clusters
Heat dissipation for main control cabinets of high-power DC charging piles.
⚠️ Operating Limitations (부적합한 시나리오, 선택 참고 사항)
- 주변 온도 >+60℃ 또는 <-20℃ exceeds fan operating range;
- Environment with high concentration of corrosive gas or direct heavy oil/water splash (Protection Class IP20; extra protective measures needed);
- Application requiring precise 0–10V analog speed control: This is an AC fan and only compatible with REE10 phase-angle controller, 0–10V EC fan control is not supported;
- Closed duct with ultra-high backpressure: Axial fan has limited static pressure; centrifugal fans are recommended for high-pressure duct systems.
Recommended Matching Configuration
Speed control for single fan → REE10 (Original phase-angle speed controller as shown in picture);
Centralized speed control for multiple parallel fans → REE30;
Dusty on-site environment: Install dust filter at fan air inlet side.
접촉기,회로 차단기,태양광 인버터,전기 계량기,감지기,인코더,PLC


















NH42-63-318x560.png)