키엔스 GS-11N5 Non-contact Safety Interlock Switch (GS Series Standard Type, NPN Output, 5m Pre-cabled)
애플리케이션: Non-contact interlock detection for equipment safety guards/protective doors. Used together with GS series actuators (magnetic heads). Applied to machine tools, automated production lines and robot safety fencing.
✅ 모델 코드 설명
GS: GS series non-contact safety interlock switch
11: Standard main unit model
N: NPN OSSD safety output (P stands for PNP)
5: 5m pre-fitted cable with bare wire ends (GS-11N10 is the 10m cable variant)
📋 Core Electrical & Sensing Specifications
- 전원공급장치: DC24V ±20%, 수업 2 전원 공급 장치
- 산출: Dual OSSD NPN safety transistor outputs + 1 auxiliary non-safety AUX output (최대. 50엄마)
- 감지거리 (with GS actuator)
전면 장착: Sao(끄기→켜기)=10mm; Sar(켜기→끄기)=18mm
측면 장착: Sao(끄기→켜기)=6mm; Sar(켜기→끄기)=14mm
- 응답 시간
Detected → Not detected: 20ms +2ms ×(number of cascaded units −1)
Not detected → Detected: 30ms +25ms ×(number of cascaded units −1)
- Cascading: 최대 30 units in series
- 맥스. door actuation frequency: 3헤르츠
- 안전 인증
EN ISO13849-1: PLe / Category4
IEC61508: SIL3; EN ISO14119 Type4 safety switch
- 보호: 역방향 전원 극성 보호, output short-circuit protection, 서지 보호
🧵 Cable Pin Definition (8-core bare-end cable)
| 와이어 색상 | 신호 | 설명 |
| 갈색 | 핀2 | DC24V Positive |
| 파란색 | Pin7 | 0V GND |
| 검은색 | Pin5 | OSSD1 (안전 출력 1, NPN) |
| 하얀색 | Pin6 | OSSD2 (안전 출력 2, NPN) |
| Red/Black | Pin8 | Safety Input 1 |
| Red/White | 핀4 | Safety Input 2 |
| 회색 | 핀 1 | AUX auxiliary output (non-safety, for PLC status feedback) |
| 라이트 블루 | 핀3 | 미사용, must be individually insulated |
배선 참고 사항: Dual OSSD outputs connect to safety relay / safety PLC; AUX is only for status monitoring, MUST NOT be wired into safety circuit.
📌 Selection & 어울리는 액세서리
GS-11N5 is only the switch body. GS series actuator (magnetic head) 별도로 주문해야 합니다, 예를 들어. GS-A10, GS-A20. No mechanical contact between actuator and main unit; detection relies on magnetic field.
Peer models comparison:
GS-11N5: NPN, 5m 케이블
GS-11N10: NPN, 10m 케이블
GS-11P5: PNP, 5m 케이블
GS-11P10: PNP, 10m 케이블
⚠️ Installation & 유지 관리 지침
- The gap between main unit and actuator must stay within rated sensing range. Reserve clearance for vibration-prone sites to prevent false triggering.
- Do not install close to strong magnets to avoid magnetic interference.
- For cascaded configuration, total response time increases with series quantity; safety circuit assessment must include delay.
- Enclosure IP rating: 산업 환경에 적합, avoid continuous immersion.
- Troubleshooting priority: 전원 공급 장치를 확인하세요, cable breakage, actuator position offset first. Mismatch of dual OSSD channels usually indicates fault.
📎 Alternative Products
Similar non-contact safety gate switches: Schneider XCS-DMP, Pilz PSENmag, Omron D40A series. Note differences in safety level, OSSD type and cascading capability; direct replacement into safety circuit is not allowed.
GS-11N5 Troubleshooting Checklist (LED 표시기 + 현상 + 치료)
GS-11N5 equipped with tri-color LED: 녹색 / 주황색 / 빨간색. Judge fault by LED status first.
Never short OSSD channels for testing. Lock-out & tag-out equipment before modifying safety circuits.
- LED Status Definition
| LED 상태 | 의미 |
| Solid Green | 정상: actuator detected, door closed, dual OSSD channels conductive |
| Solid Orange | Power OK, actuator not detected (door open), OSSD cut off |
| Solid Red | Internal fault / OSSD channel mismatch / 단락, safety circuit locked |
| Flashing Red | Cascading circuit fault / wrong safety input wiring |
| No LED | 전원 공급 장치 없음, broken power wire, reverse polarity |
- Step-by-step Troubleshooting (단순한 것부터 복잡한 것까지)
2.1 Power Check (priority when no LED)
- Measure Brown(24V+) and Blue(0다섯), confirm DC24V within 19.2~28.8V
- Check reverse polarity. Built-in reverse protection prevents burnout but unit will not operate.
- Inspect cable root for bending damage (5m cable model most prone to wire breakage at root).
- Confirm Class2 power supply with sufficient capacity and no voltage drop.
2.2 Sensing Gap & 액추에이터 (solid orange LED, door closed but no detection)
- Confirm actuator is GS series (GS-A10 / GS-A20). Other brand magnetic heads cannot be used.
- 전면 장착: gap ≤10mm for activation; >10mm cannot trigger; >18mm permanently off.
- 측면 장착: Sao=6mm, Sar=14mm, stricter gap requirement.
- Check loose mounting brackets, vibration shift, deformed metal cover squeezing main unit/actuator.
- Check nearby strong magnets, inverters or high-current cables causing magnetic interference.
2.3 Safety Input Wiring (Most common pitfall for non-cascaded use)
For GS-11N5 (NPN), when not cascaded, the two safety inputs must be shorted to 0V (Blue wire)
Red/Black (Safety Input1) and Red/White (Safety Input2) short to 0V;
✘ Wrong: floating / connected to 24V → red fault LED.
Cascading: OSSD outputs of previous GS connect to safety inputs of next unit, channel-to-channel matching.
2.4 OSSD Dual Channel Fault (Solid Red LED)
징후: OSSD1 and OSSD2 status mismatch, safety relay reports channel error
- Disconnect load and measure Black(OSSD1) and White(OSSD2) 갈라져.
- Check OSSD cable short to ground or inter-wire short; OSSD short-circuit protection triggers latch-up.
- Wiring resistance limit: total loop resistance ≤2.5Ω; long/thin cables may trigger fault.
- Capacitive load limit: 최대. 2.2μF; parasitic capacitance of long cables may cause timing mismatch between channels.
- Check cross-wiring between safety relay / safety PLC channels. OSSD1 and OSSD2 must not be swapped.
2.5 AUX Auxiliary Output (Status feedback only, non-safety)
Gray AUX follows door state, only for PLC monitoring, must not be inserted into safety circuit
Door closed: AUX ON; Door open: AUX OFF
AUX abnormality does not affect OSSD safety function, only status indication.
- Quick Fault Reference Table
| 결함 현상 | 가능한 원인 | 치료 |
| Door fully closed, orange LED remains, safety circuit open | Gap exceeds Sao, mounting offset, wrong actuator | Adjust gap, fasten bracket |
| Red LED on at power-up, cannot reset | Wrong safety input wiring (NPN not shorted to 0V); OSSD short | Check Red/Black & Red/White wiring; disconnect load to retest OSSD |
| Intermittent safety fault, random tripping | Cable root breakage; gap drift under vibration; cable voltage drop | 케이블 교체; reinforce mounting; increase wire gauge |
| Cascaded units, downstream unit red LED | Wrong cascading wiring; excessive total response time | Disconnect cascade one by one to locate faulty unit; evaluate total safety delay |
| Normal briefly after power cycle, fault soon recurs | Hidden short in output loop; excessive cable parasitic capacitance | Shorten cable length, add termination to reduce capacitance |
- Criteria for Main Unit Damage Replacement
Replace GS-11N5 if any condition below is met:
- 힘, wiring and actuator are fully verified correct, red LED latched and cannot reset.
- Actuator within qualified sensing distance, green LED fails to light up.
- OSSD channel mismatch persists even after all external loads disconnected.
⚠️ Safety Precautions
- Shut down equipment and cut off power before safety circuit test.
- Do not short OSSD safety outputs for commissioning.
- Perform full safety function verification after switch replacement.
- 맥스. 30 units for cascading; longer chain brings larger response delay, which must be included in safety assessment.
GS-11N5 Wiring Example for Safety PLC
전제 조건: GS-11N5 is NPN OSSD dual safety output. This case: 단일 단위, non-cascaded, widely used for safety gates on automated lines.
Safety PLC examples: KEYENCE KV-S04 / Pilz PNOZmulti / Siemens F-PLC. Principle is universal, terminal numbers vary by brand.
⚠️ 중요: OSSD is safety transistor output, NEVER short OSSD for testing. Lock-out & tag-out before modifying safety circuit.
- GS-11N5 Cable Assignment (Single unit, non-cascaded)
| 와이어 색상 | 신호 | Wiring Target | 비고 |
| 갈색 | DC24V+ | 24V Power Positive | Main unit power supply |
| 파란색 | 0다섯(접지) | 24V Power Negative | Main unit power supply |
| 검은색 | OSSD1 (Safety Channel1 NPN) | Safety PLC Safety Input CH1 | NPN: pulled to 0V when door closed |
| 하얀색 | OSSD2 (Safety Channel2 NPN) | Safety PLC Safety Input CH2 | Dual independent channels, connect to two separate safety inputs |
| Red/Black | Safety Input1 | Short to Blue(0다섯) | Mandatory for non-cascaded use; floating wire triggers red fault LED |
| Red/White | Safety Input2 | Short to Blue(0다섯) | Mandatory for non-cascaded use |
| 회색 | AUX Auxiliary Output | Standard PLC Digital Input (non-safety point) | Door status monitoring only, must not connect to safety circuit |
| 라이트 블루 | 미사용 | Insulate separately, no connection | Do not ground or connect to 24V |
NPN OSSD Characteristics:
✅ Door closed (actuator in place): OSSD1 & OSSD2 turn ON → Black & White ≈0V
✅ Door open: OSSD1 & OSSD2 OFF → high impedance, near 24V
- Safety PLC Side Wiring Logic (Dual-channel Safety Input)
Two common safety PLC input types:
A형: Sourcing safety input (High level active)
GS-11N5 NPN OSSD cannot directly drive sourcing safety input
✅ Solution: Pull-up resistors (2.2kΩ /0.5W recommended) on Black & White wires to DC24V.
When door closed, OSSD pulls signal low. PLC detects consistent low level on both channels as safe state.
B형: Sinking safety input (Low level active, 추천)
Direct connection for GS-11N5, no extra resistors needed
Safety PLC internal: safety input terminals pulled up to 24V
Black OSSD1 → Safety Input CH1
White OSSD2 → Safety Input CH2
Door closed: OSSD ON, CH1 & CH2 pulled to 0V, dual-channel consistent, safety circuit enabled
Door open: OSSD OFF, CH1 & CH2 return to 24V, safety circuit de-energized
- AUX Auxiliary Output Wiring (표준 PLC)
Gray AUX (NPN):
AUX emitter internally connected to 0V; collector requires external 24V pull-up to standard PLC DI
Standard DI wiring: 24V → DI terminal; Gray wire to DI common
Door closed: AUX ON → DI ON; Door open: AUX OFF → DI OFF
용법: HMI door status display, 경보 표시; must not be used for safety stop logic
- Cascading Overview (Multiple GS-11N5 in series to Safety PLC)
Used for multiple safety doors in series detection, 최대. 30 단위
- OSSD1 (검은색) of previous GS → Safety Input1 (Red/Black) of next GS
- OSSD2 (하얀색) of previous GS → Safety Input2 (Red/White) of next GS
- Last GS-11N5: OSSD1 & OSSD2 connect to dual safety inputs of safety PLC
- Safety Inputs of first GS shorted to 0V
메모: Total response time accumulates in cascade; safety evaluation must calculate total delay. Any door open will cut off OSSD for the whole chain.
- Safety PLC Program Configuration Points
- Channel Mode: Set as Dual-channel safety input, enable cross monitoring for channel discrepancy
- Discrepancy tolerance time: 20~50ms typically, do not set excessive value
- Fault action: Channel mismatch → safety stop, latch fault, reset signal required
- Do not use AUX signal for safety stop logic; use only for diagnostic alarm
- After program download, full function test: door closed allow run, door open immediate stop, single wire break triggers safety fault
- Site Commissioning Checklist
- 사전 전원 확인: Red/Black & Red/White shorted to 0V (단일 단위), Light Blue insulated
- LED test: Actuator near → solid green; actuator removed → solid orange; no red LED
- PLC signal: CH1 & CH2 go low simultaneously when door closed; high when door open
- Fault simulation: Disconnect Black or White wire individually; PLC must detect channel mismatch and trigger safety fault
- Cable parasitic capacitance: Use shielded cable for wiring >20중, shield grounded at single end to prevent false OSSD action
- 일반적인 함정
- ❌ Red/Black & Red/White floating for single unit: immediate red latch-up, frequent beginner wiring mistake
- ❌ AUX Gray wire connected to safety PLC safety channel: safety certification invalid, major hazard
- ❌ NPN OSSD directly to sourcing safety input: reversed logic, cannot work properly
- ❌ Safety PLC set to single channel mode: loss of cross-channel fault detection, safety rating downgraded
KEYENCE GS Series Safety Gate Switch Full Model List
GS series is divided into three categories: GS-10 Non-locking non-contact magnetic safety switch (GS-11N5 belongs to this group), GS-50 Solenoid locking (Power-to-release), GS-70 Solenoid locking (Power-to-lock)
Model coding rule:
N = NPN output; P = PNP output
5 = 5m bare cable; 10 = 10m bare cable; PC = M12 connector (0.3m short pre-cable)
11=표준; 10=Basic; 13=High-function; 51/71=Locking standard; 53/73=Locking high-function
- Non-contact Type (No solenoid lock, magnetic safety switch GS10 Series)
Only for door position detection, no locking function; PLe / Cat4 / SIL3, 최대 30 계단식 장치
| 모델 | 유형 | 산출 | Cable Style | 설명 |
| GS-10PC | 기본형 | PNP | M12 Connector | 기본 모델, simplified function, no EDM |
| GS-11N5 | 표준형 | NPN | 5m bare cable | Your target model, 8-core bare wire |
| GS-11N10 | 표준형 | NPN | 10m bare cable | NPN,10m 케이블 |
| GS-11P5 | 표준형 | PNP | 5m bare cable | PNP,5m 케이블 |
| GS-11P10 | 표준형 | PNP | 10m bare cable | PNP,10m 케이블 |
| GS-11PC | 표준형 | PNP | M12 Connector | M12 커넥터 버전 |
| GS-13P5 | High-function | PNP | 5m bare cable | Support EDM external device monitoring, manual reset |
| GS-13PC | High-function | PNP | M12 Connector | High-function, M12 커넥터 |
- Solenoid Lock GS-50 Series (Power-to-release: Locked when powered, unlocked on power loss)
Locking logic: Keep energized to hold lock; door releases automatically upon power failure. Suitable for safety guard doors, safety chambers.
| 모델 | 유형 | 산출 | Cable Style |
| GS-51N5 | Locking Standard | NPN | 5m bare cable |
| GS-51N10 | Locking Standard | NPN | 10m bare cable |
| GS-51P5 | Locking Standard | PNP | 5m bare cable |
| GS-51P10 | Locking Standard | PNP | 10m bare cable |
| GS-51PC | Locking Standard | PNP | M12 Connector |
| GS-53PC | Locking High-function | PNP | M12 Connector |
- Solenoid Lock GS-70 Series (Power-to-lock: Lock only when energized)
Unlocked when power off; coil must be energized to engage lock. Suitable for robot safety doors.
| 모델 | 유형 | 산출 | Cable Style |
| GS-71N5 | Locking Standard | NPN | 5m bare cable |
| GS-71N10 | Locking Standard | NPN | 10m bare cable |
| GS-71P5 | Locking Standard | PNP | 5m bare cable |
| GS-71P10 | Locking Standard | PNP | 10m bare cable |
| GS-71PC | Locking Standard | PNP | M12 Connector |
| GS-73PC | Locking High-function | PNP | M12 Connector |
- Matching Actuators (Magnetic head, mandatory for GS main unit)
| 모델 | 이름 |
| GS-A10 | Standard Actuator |
| GS-A20 | Long Sensing Distance Actuator |
- 장착 브래킷 & 부속품
GS-B01, GS-B11, GS-B21, GS-B31, GS-B41, GS-B33, GS-B43
- Other Accessories
GS-T01: Test Tool
✅ Quick Selection Guide
- Only door detection, no locking → GS-10 series (GS-11N5/GS-11P5)
- Lock required, auto unlock on power loss → GS-50 series
- Lock required, lock only when powered → GS-70 series
- High-function models (GS-13/53/73): support EDM external diagnostic, manual reset; GS11/51/71 standard versions do not support EDM.
주목: GS models with SO suffix (GS-10PCSO / GS-11PCSO / GS-51PCSO / GS-71PCSO) are special custom versions, rarely used in general projects.