상태: EOLEndofLife. LUST was acquired by KEBA; OEM supply discontinued. Only used / secondhand / refurbished units available on market. Model Code Decoding `CDE32.003.C2.4` Segment Definition CDE Series: Pos‑Servo CDE3000 series, positioning servo drive; 지지 위치 / 속도 / 토크 제어 모드 32 전압 등급: 3×230 V AC; 34 stands for 400 V class 3 Rated output‑current code: 3 에이 ...

  • 제품 세부정보

상태: EOLEndofLife. LUST was acquired by KEBA; OEM supply discontinued. Only used / secondhand / refurbished units available on market.

  1. Model Code Decoding

`CDE32.003.C2.4`

분절정의
CDE시리즈: Pos‑Servo CDE3000 series, 포지셔닝 서보 드라이브; 지지 위치 / 속도 / 토크 제어 모드
32전압 등급: 3×230 V AC; 34 stands for 400 V class
3Rated output‑current code: 3 A continuous, 6 A peak
기음Hardware revision C
2인코더 인터페이스: EnDat 2.2
4Firmware version V2.4; suffix .PC1 = Profibus‑DP option board (not included in base unit CDE32.003.C2.4)

Order reference: `1021.0003.x` (base order code for CDE32.003 series)

  1. 주요 전기 사양
매개변수
Main power supply3‑phase 208‑230 V AC, 50‑60 Hz
제어 전원24 V DC external supply
Continuous output current3 A rms
Peak output current6 에이 (duration limited by overload curve)
Compatible motor power0.25‑0.75 kW, 230 V LUST synchronous servo motors
Control modes위치 (on‑board positioning), speed loop, torque loop
인코더EnDat 2.2 (Hardware C2.4); TTL incremental optional on other hardware variants
입출력디지털 입력 / 출력, analog ±10 V setpoint; X2 control terminal block
Motor brake outputTerminal X9, 24 V motor brake drive with cable‑break monitoring

환경 조건

작동 온도: 0 ~ +45 °C (cabinet installation with forced ventilation; derating above 40 °C)

저장 / 운송 온도: −25 ~ +70 °C

습기: 590 %RH, no condensation permitted

설치: DINrail mounting inside cabinet; IP20

기계적 치수 (CDE32 small housing)

Width 55 mm × Height 215 mm × Depth 150 mm; prefitted DINrail clips.

  1. Interface Overview
  2. X1: 3phase main power input L1/L2/L3, DCbus brakeresistor terminals
  3. X2: 제어 I/O (디지털 I/O, analog setpoint, enable, faultrelay output)
  4. X6: Motor power output U/V/W, PE protective earth
  5. X7: EnDat encoder port
  6. X9: 24 V motorbrake output; requires external 24 V supply, cablebreak detection included
  7. KP200: Handheld keypad interface for parameter access and fault reading

Commissioning software: DriveManager (legacy LUST tool; native support for Windows XP / 7; compatibility mode required for Win10).

  1. Quick FaultCode Reference (CDE3000 series)
표시하다오류 설명Typical Root Causes
E‑CPUCPU / firmware hardware faultMain‑board damage, parameter corruption, RAM failure
E‑OC과전류Motor short‑circuit, earth‑fault, power‑stage failure, motor insulation breakdown
끄다DC‑bus undervoltage3‑phase input phase‑loss, insufficient main‑supply voltage
E‑OTIDrive over‑temperature열 방출 불량, fan failure, excessive ambient temperature
E‑OTMMotor over‑temperatureMotor thermistor open‑circuit, 모터 과부하
E‑PLS인코더 결함EnDat communication error, 손상된 케이블, encoder hardware failure
E‑CANCAN bus faultMissing 120 Ω termination resistor, bus short‑circuit

H1 redLED blink code: number of blinks indicates fault group; full fault information readable via KP200 keypad.

  1. 교체 옵션 (중요한: No pintopin dropin compatible replacement; hardware, wiring and software must be reworked completely)

결론: There is no plugandplay alternative. Two strategies: equipment retention via repair; or fullsystem upgrade.

Strategy 1: Repairbased retention of existing machine

Source used / secondhand CDE32.003.C2.4. 위험: limited availability, component ageing. Powerboard inspection and capacitor refurbishment recommended.

Verify firmware version and encoder type (EnDat 2.2) for matching with existing motor.

Strategy 2: 전체 업그레이드 (KEBA successor & 3rdparty servos)

  1. KEBA KeDrive D3 series (technical inheritance from LUST): Requires new electrical drawings, encoder reconfiguration. DriveManager project files cannot be imported directly.
  2. 3rdparty candidates: Schneider Lexium 28, 비&R ACOPOSmicro, Siemens S210.

중요한 메모: Original motor uses EnDat 2.2 encoder. New drive must support EnDat interface to reuse existing motor.

Selection Pitfall Warnings

  1. ❌ Never replace CDE32 (230 V class) with CDE34 (400 V class); voltage mismatch will destroy motor.
  2. ❌ Suffix C2.4 denotes EnDat hardware; cannot directly substitute C1.x (TTL incremental encoder) variants; encoder hardware is incompatible.
  3. Legacy DriveManager project files cannot be imported into KEBA KeDrive; full retuning mandatory.
  4. TypicalApplication Fields

섬유기계, 인쇄 기계, 포장 장비

Auxiliary axes for machinetools, 포지셔닝 테이블

Woodworking machinery; mostly found on legacy imported equipment.

  1. 표준 패키지 내용물

Servo drive CDE32.003.C2.4 ×1

Preinstalled DINrail mounting clips

Items NOT included, 별도로 주문해야 합니다: KP200 keypad, ProfibusDP PC1 option board, encoder cables, 전원 케이블, external braking resistor.

Compatible Original LUST Synchronous ServoMotors

Drive hardware: C2 = EnDat 2.2 absolute encoder interface; drive continuous 3 A, peak 6 A; 3×230 V AC supply.

Hard constraints: Motor must be 230 V winding synchronous servo with EnDat 2.2 (singleturn / multiturn). Motor continuous current ≤ 3 A, peak ≤ 6 A. 전력 범위: 0.250.75 kW. 400 Vwinding motors are not supported. TTL incrementalencoder motors (for C1hardware drives) cannot operate directly with this unit.

Original motor families LS, LSM, LSML (색욕 / LTi) are all EOL. Only used / refurbished units available.

  1. OEM Compatible Motor List (EnDat 2.2, 230 다섯)
모터 모델정격 출력정격 토크정격 속도정격전류비고
LS‑07‑030‑2N‑000250 여0.8 Nm3000 rpm1.4 에이Small flange, 브레이크 없음, EnDat 2.2
LS‑07‑050‑2N‑000400 여1.27 Nm3000 rpm2.1 에이No‑brake; brake variant suffix‑B000
LS‑08‑075‑2N‑000750 여2.39 Nm3000 rpm2.8 에이Maximum compatible power. Continuous operation at full load not permitted; 디레이팅 필요.
LSML‑07‑030‑4N‑000250 여0.8 Nm4500 rpm1.5 에이High‑speed low‑inertia; for high‑speed axes in textile / 포장
LSML‑07‑050‑4N‑000400 여1.27 Nm4500 rpm2.2 에이High‑speed no‑brake;‑B4N = 24 V holding brake
LSMM‑08‑075‑2N‑000750 여2.4 Nm3000 rpm2.9 에이중간 관성, 80 mm flange; auxiliary machine‑tool axes

Modelcode breakdown example `LS070502NB000`

  1. `LS`: standardinertia synchronous servo; `LSML`: lowinertia highspeed; `LSMM`: mediuminertia
  2. `07 / 08`: flange code (07 = 70 mm; 08 = 80 mm)
  3. `030 / 050 / 075`: power ×10 W (075 = 750 W)
  4. `2` = 3000 rpm; `4` = 4500 rpm
  5. `N` = EnDat 2.2 encoder; `I` = TTL incremental encoder (NOT for this drive)
  6. `B` = integrated 24 V holding brake; noB = brakeless.
  7. Electrical Boundary Conditions (Selection Hard Rules)
  8. 현재 한도: Motor continuous RMS current ≤ 3 A; motor peak current ≤ 6 A. 750 W is upper power limit; avoid continuous fullload operation, apply derating.
  9. Encoder mandatory match: X7 hardware is EnDat 2.2. Motor encoder suffix must be2N /4N. Isuffix TTL incremental motors plugged into X7 trigger EPLS encoder failure.
  10. Winding voltage: Must be 230 V winding. 400 Vwinding motors strictly forbidden on CDE32; excitation cannot function correctly.
  11. Brake drive: Motorintegrated 24 V holding brake connects to X9. X9 requires independent external 24 V supply; drive does not source brake power. Cablebreak monitoring active.
  12. Motor temperature sensor: Onboard PTC thermistor may be connected for driveside monitoring, triggers EOTM motorovertemperature.
  13. 3rdParty Motor Compatibility Requirements

CDE32.003.C2.4 can drive 3rdparty permanentmagnet synchronous motors only if all conditions are satisfied:

  1. Motor winding 3×230 V AC; continuous phase current ≤ 3 A.
  2. 피드백: Heidenhain EnDat 2.2, DSub15 pinout matching LUST cable specification.
  3. All motor parameters must be manually entered in DriveManager: stator resistance, d/qaxis inductance, polepair count, 마디 없는 / peak current, backEMF Ke. No preloaded motor database; no autorecognition.

⚠️ Risk: Incorrect tuning of 3rdparty motors leads to EOC overcurrent, axis oscillation or poor positioning accuracy. Prefer original LS / LSML series motors.

  1. Common MismatchRelated Faults
오류 코드현상근본 원인
E‑PLSEncoder alarmMotor fitted with TTL‑I instead of EnDat‑N; 케이블 손상; pin‑out mismatch
E‑OC on enableImmediate over‑current upon enable400 V‑winding motor connected; motor winding short‑circuit; wrong pole‑pair / inductance parameters
E‑OTM motor over‑temp alarmMotor physically coolPTC thermistor wiring missing; motor mechanical overload
토크 부족 / low maximum speedMotor rated‑current exceeds drive 3 A rating; wrong back‑EMF setting
  1. MotorDrive System Upgrade Paths (when original motor fails)
  2. Repair route: Source used LSxxxxx2N /4N motor. Verify EnDat 2.2 encoder health, check ratedcurrent, retune via DriveManager.
  3. Fullsystem replacement route: KEBA KeDrive D3 drive plus KEBA synchronousmotor; or 3rdparty servo. Match original mechanical flange and shaft dimensions.

메모: Existing DriveManager motor parameters cannot be imported into new platform; full retuning is required.

  1. Associated Cabling
  2. Motor power cable: LUSTspec power cable U/V/W/PE including PTC temperature feedback conductors.
  3. Encoder cable: Doubleshielded dedicated EnDat 2.2 DSub15 cable. Do NOT reuse TTL incremental encoder cables.
  4. Brake conductors integrated within power cable, routed to X9.

LUST CDE3000 (CDE32.003.C2.4) Complete FaultCode Table

메모:

  1. H1 redLED blink count = main fault group number. Detailed subfault codes readable via KP200 or DriveManager.
  2. Fault reset: powercycle; or pressandhold KP200 STOP key ≥ 3 s; or software faultacknowledge.
  3. Many faults carry subcodes stored in parameter `ERPAR`, read in DriveManager for precise diagnosis.
  4. Valid for CDE32 / CDE34 families. For CDE32.003.C2.4 (EnDat 2.2) pay special attention to EPLS.
  5. Main Fault Table (H1 blink count / KP200 display)
Blinks표시하다Fault Name설명근본 원인 & 치료
1E‑CPUCPU / Processor FaultController hardware / firmware anomaly① Power‑cycle reset. ② Re‑occurrence indicates main‑board failure; replace control board.
2E‑OFFDC‑Bus Undervoltage TripDC‑bus voltage below threshold① 3‑phase input phase‑loss / low supply voltage. ② Blown main‑circuit fuse. Brief normal occurrence during power‑down.
3E‑OCOver‑Current TripOutput‑current limit violation; hardware or software protectionSub‑codes: 19 software overcurrent; 34 fast Ixt overcurrent; 35 power‑on self‑test short‑circuit; 41 hardware power‑stage overcurrent.
Check for U/V‑W short‑circuit, motor earth‑fault, power‑module damage, 잘못된 모터 매개변수, 케이블 손상.
4E‑OVDC‑Bus Over‑Voltage TripDC‑bus overvoltage from regenerative energy① Mains over‑voltage. ② Excessively steep deceleration ramp. ③ Missing / damaged braking resistor. Fit brake resistor; 감속 시간을 연장하다.
5E‑OLMMotor I²t Overload ProtectionMotor thermal‑model overload timeout기계적 방해; 과도한 부하; high acceleration rates. Verify motor parameters; reduce mechanical load; inspect mechanics.
6E‑OLIDrive I²t Overload ProtectionPower‑stage thermal overload timeoutContinuous operation above rated capacity. Apply derating; verify power sizing; improve cabinet cooling.
7E‑OTMMotor Over‑Temperature FaultPTC thermistor trigger① Broken / mis‑wired PTC circuit. ② Genuine motor thermal overload. Check actual motor temperature and X2 PTC wiring.
8E‑OTIDrive Over‑Temperature FaultHeatsink / internal PCB overtemperature. Sub‑codes 31 heatsink over‑temp; 32 internal cabinet over‑temp.열악한 캐비닛 환기; fan fault; 주변 > 45 °C. Clear airflow derating; reduce enclosure temperature.
9E‑PLS인코더 / Feedback Checksum FaultInvalid feedback signal, encoder communication failure, position‑check errorHigh‑frequency alarm for C2.4 EnDat 2.2 variant.
Check X7 encoder‑cable damage, poor shield‑grounding, bent D‑Sub‑15 pins, encoder hardware failure. Never fit TTL incremental cables to EnDat port.
10E‑PARParameter ErrorParameter out‑of‑bounds, initialization failure; faulty‑parameter‑ID stored in ERPARCorrupted parameter download; out‑of‑range settings. Restore factory defaults; reload valid motor‑parameter‑set.
11E‑EEPEEPROM Storage FaultNon‑volatile‑memory read‑write errorPower‑cycle reset. Repetitive fault indicates EEPROM chip hardware damage on main‑board.
12E‑CANCAN‑Bus FaultCANopen communication failure; sub‑codes cover Bus‑Off, heartbeat error, PDO exceptionsMissing 120 Ω termination resistors at bus ends; bus short‑circuit; conflicting node‑ID; baud‑rate mismatch; defective cable.
13E‑POSPositioning FaultOn‑board position‑controller failure; target‑position overflow; following‑error threshold exceeded기계적 발작; poorly tuned servo gains; following‑error threshold set too low. Inspect mechanics and position‑/speed‑loop parameters.
14E‑PLCOn‑Board Sequencer FaultUser‑macro runtime error; stack overflow, division‑by‑zero, syntax errorInspect custom PLC‑macro code. Clear user‑program; restore factory macro set. Read sub‑code for fault‑line number in DriveManager.
15E‑BRBrake Unit FaultInternal brake‑chopper fault; brake‑resistor short‑circuit / open‑circuitWrong brake‑resistor ohmic value; resistor open‑circuit; brake‑power‑board damage. Verify resistor specifications.
16E‑EXTExternal Fault InputExternal‑fault signal at X2 terminal (logic configured by parameter 524)Fault‑signal asserted by external equipment. Inspect external fault‑loop wiring and parameter configuration.
  1. Selected ERPAR SubCode Definitions

EOC (OverCurrent) Subcodes

19: Software overcurrent protection

34: Fast Ixt overload (lowfrequency shortcircuit condition)

35: Shortcircuit detected during poweron selftest

41: Hardware powerstage overcurrent

EOTI Subcodes

31: Heatsink overtemperature

32: Drive internalchamber overtemperature

ECAN Selected Subcodes

31: BusOff state

39: Heartbeat monitoring failure

40: Invalid CAN nodeID

42: PDO sync supervision error

EPAR Selected Subcodes

5: Parameter download overflow

6: Parametertable initialization failure

7: Parametersave failure

8: Parameterread failure

47: Motorprotectionparameter initialization error

100123: Controlmodule initialization failures (currentloop, speedloop, positionloop, encoderinterface)

  1. Warnings (WARN: no drive trip; statusbit only)

WARNOLM: Motor overload prewarning (pretrip threshold)

WARNOLI: Drive overload prewarning

WARNOTM: Motor temperature prewarning

WARNOTI: Drive temperature prewarning

Warnings do not disable powerstage; read status bits in DriveManager / PLC for proactive load / coolingcondition inspection.

  1. HighFrequency Troubleshooting for CDE32.003.C2.4 (EnDat 2.2)
  2. EPLS (mostcommon fault)

Symptoms: Alarm at poweron OR random runtime trips.

원인: Damaged X7 EnDat cable; bent DSub15 pins; TTLencoder motor connected to C2 hardware; encoder hardware failure; poor shieldearthing.

Prohibition: Never insert TTL incrementalencoder cables into EnDat port.

  1. EOC on enable

Verify motor winding is 230 V class (400 V windings forbidden). Check motorparameter entry (polepair count, stator d/q inductance).

  1. Frequent EOFF undervoltage trips

CDE32 requires full 3phase 230 V supply. Confirm L1L2L3 are all connected; no phaseloss.

  1. EOTM alarm while motor is physically cool

Check X2 PTC thermistor wiring. If motor has no PTC sensor, disable PTC monitoring in parameters.

  1. General FaultHandling Workflow
  2. Record panel fault code. If possible connect DriveManager and capture faultlog plus ERPAR subcode.
  3. Poweroff; disconnect motor powercable and encodercable to isolate whether fault originates from drive, cable or motor.
  4. Measure motor insulation resistance, PTC resistance, and brakeresistor ohmic value.
  5. Restore factory parameters; reload valid OEM motorparameterset; retune currentloop and speedloop.
  6. Hardwarerelated faults (ECPU, hardwaresubcode EOC): repair or replace drive unit.