MITA-Teknik WP-LINE 351 COMBI-1 (9780351) Wind Power Dedicated Combined I/O Module
Developed by Denmark-based MITA-Teknik (now owned by Emerson), this high-density multi-functional I/O module is specially designed for 1.5MW~5MW wind turbine generators. As a core component of the WP4x00 control system, it integrates 26 DI channels + 16 DO channels + 8 AI channels + 4 AO channels + 10 temperature inputs + 4 high-speed counting channels and dual serial port communication. It supports redundant power supply, hot swapping, 넓은 온도 범위 (-40℃~+70℃) and IP20 protection rating. It holds CE/UL/CSA/RoHS/EAC certifications and complies with air freight regulations (no built-in lithium battery). Part No.: 9780351 (MK II upgraded version: 978035102).
- 모델 코드 정의
| 부분 | 암호 | 설명 |
| 브랜드 로고 | MITA‑Teknik | Professional Danish wind power control brand, acquired by Emerson in 2018 |
| 시리즈 코드 | WP‑LINE 351 | 3rd-generation wind power I/O module platform; 351 stands for combined I/O |
| 기능 유형 | COMBI‑1 | Multi-functional combined I/O (Digital + 비슷한 물건 + 온도 + High-speed Counting) |
| 주문 번호 | 9780351 | 표준 모델 (MK II version: 978035102) |
| Version Mark | 없음 / MK II | None = 1st generation; MK II = 2nd generation with optimized hardware |
Full Model Definition: MITA-Teknik WP-LINE 351 series combined I/O module integrated with digital, 비슷한 물건, 온도, high-speed counting and communication functions. Standard order number is 9780351, compatible with WP4x00 wind power control system.
- 핵심 기술 사양 (2026 Official Manual)
| 범주 | 사양 | 비고 |
| 디지털 I/O | ||
| 디지털 입력 (에서) | 26 채널, 24VDC, sink/source type optional | ±36VDC overvoltage protection, input impedance: 10kΩ |
| 디지털 출력 (~하다) | 16 채널, 24VDC/0.5A (Relay/Transistor optional) | 단락 보호, automatic overload recovery |
| High-speed Counting Input | 4 채널, 최대. 100kHz | Supports encoder A/B phase and pulse signals for rotational speed measurement |
| Analog I/O | ||
| 아날로그 입력 (일체 포함) | 8 채널, 4‑20mA/0‑10V, 12-비트 해상도 | 입력 임피던스: 250오(현재의)/1MΩ(전압), 정확성: ±0.1%FS |
| 아날로그 출력 (에) | 4 채널, 4‑20mA/0‑10V, 12-비트 해상도 | 맥스. 짐: ≤500Ω(현재의)/≥10kΩ(전압) |
| Temperature Input | 8-channel 3-wire PT100 (-200℃~+600℃) + 2-channel NTC thermistor | Measuring accuracy: ±0.5℃ (-50℃~+150℃) |
| 통신 인터페이스 | ||
| COM1 | RS232/422/485/SSI (software programmable switch) | Compatible with SSI encoder, Modbus RTU master/slave |
| COM2 | RS485 (Modbus RTU slave) | Connect third-party meters, converters and other peripheral devices |
| 백플레인 버스 | WP‑BUS (2Mbps high-speed communication) | Auto identification and communication with WP4100/WP4200 controllers |
| 전기적 특성 | ||
| 전원공급장치 | 24VDC (19~30VDC, dual redundant power input) | Reverse polarity protection, 4kV surge suppression |
| 전력 소비 | ≤15W (full configuration) | Operating current ≤0.6A @24VDC |
| Isolation Level | 2.5kV between channels, 1.5kV between channel and ground | Compliant with IEC 61010‑1 safety standard |
| 물리적 & 환경 매개변수 | ||
| 차원 (폭×높이×깊이) | 22.5×100×120mm | 표준 35mm DIN 레일 장착 |
| 보호 등급 | IP20 | 제어 캐비닛 내부 설치에 적합 |
| 작동 온도 | ‑40℃ ~ +70℃ | Adaptable to extreme wind power site environments |
| 보관 온도 | ‑40℃ ~ +85℃ | For transportation and storage |
| 진동 & 충격 저항 | 10~55Hz, 0.5mm 이중 진폭 / 100m/s² | Compliant with IEC 60068‑2‑6/27 standards |
| 인증 | ||
| CE | EN 61010‑1, EN 61326‑1 | 인증서 번호: CE2019‑MITA‑0035 |
| UL | UL 508, UL 61010‑1 | 인증서 번호: E482976 |
| CSA | C22.2 No.14 | 인증서 번호: LR765432 |
| RoHS 규제 | 2011/65/EU | Comply with RoHS 2.0 hazardous substance restrictions |
| EAC | TR CU 004/2011 | Customs Union certification for Russia, 카자흐스탄, 등. |
- 전체 시리즈 모델 목록 (WP-LINE 351 시리즈)
| 모델 | 주문 번호. | Function Configuration | 응용 시나리오 |
| WP‑LINE 351 COMBI‑1 | 9780351 | 26DI+16DO+8AI+4AO+8PT100+2NTC+4 High-speed Counter | General wind turbine main control I/O expansion |
| WP‑LINE 351 COMBI‑1 MK II | 978035102 | Upgraded hardware, backward compatible, added diagnosis function | Wind turbine renovation & new unit standard configuration |
| WP‑LINE 351 COMBI‑2 | 9780352 | 16DI+24DO+4AI+8AO+4PT100+4 High-speed Counter | Applications focusing on output control |
| WP‑LINE 351 DIGITAL | 9780353 | 40DI+20DO+4 High-speed Counter | Pure digital control occasions |
| WP‑LINE 351 ANALOG | 9780354 | 16AI+8AO+16PT100 | Applications focusing on analog and temperature collection |
| WP‑LINE 351 COMM | 9780355 | 16DI+16DO+4AI+4AO+4 Serial Ports | Communication-intensive applications |
Selection Formula: Choose COMBI-1/2 for I/O ratio; select DIGITAL/ANALOG/COMM by type; MK II is upgraded version; identify models via 978035X; prioritize 351 series for wind power main control with redundant power and hot swap.
- Internal Replacement & 브랜드 간 동등한 모델
4.1 MITA Internal Replacement & 호환성
| 원래 모델 | 교체 모델 | 설명 |
| WP‑LINE 350 COMBI | WP‑LINE 351 COMBI‑1 (9780351) | 350 series discontinued; 351 series with 30% performance improvement, 완벽하게 호환됨 |
| 9780351 (1st Gen) | 978035102 (MK II) | Hardware optimization, added channel diagnosis, hot swap supported, no reprogramming needed |
| WP‑LINE 351 COMBI‑1 | WP‑LINE 351 COMBI‑1 + WP‑LINE 111 Power Module | Redundant power supply configuration to enhance system stability |
4.2 Cross-Brand Wind Power I/O Module Comparison
| 상표 | 모델 | Equivalent Specification | 차이점 |
| 씨줄 | AC500‑IO‑CM579 | 24DI+16DO+8AI+4AO+8PT100 | 15% 더 높은 가격, different communication protocol (프로피네트) |
| 지멘스 | ET 200SP AI 8xTC/AI 8xRTD | Dedicated analog & temperature module | Multiple modules required for full functions, 더 높은 비용 |
| 슈나이더 | Modicon M340 BMXAMI0800 | 8-channel analog input | Not dedicated for wind power, insufficient wide-temperature performance |
| 비&아르 자형 | X20 AI 4622 | 4-channel analog input | Needs matching X20 system, incompatible with WP4x00 |
- Application Environments & 일반적인 경우
5.1 적용 가능한 시나리오
| 산업 | 일반적인 응용 분야 | 장점 |
| 풍력 발전 | I/O expansion for 1.5MW~5MW wind turbine main control system | Integrate all signal types in one module, reduce quantity and wiring workload |
| Nacelle Control | Collection of wind speed, wind direction, vibration and temperature signals | Wide-temperature design adapts to harsh nacelle working conditions |
| Pitch System | SSI encoder position feedback and drive control for pitch motors | 100kHz high-speed counting ensures precise pitch angle control |
| Yaw System | Yaw motor control, position detection and limit protection | Fast digital output response with short-circuit protection |
| 유압 & 제동 시스템 | Hydraulic station pressure monitoring and brake control output | High analog accuracy 卤0.1%FS with output overload protection |
| Grid Monitoring | Grid-connected voltage, current and power signal collection | Compatible with Modbus RTU to connect power quality analyzers |
5.2 Non-Recommended Applications
Offshore wind power salt fog environment (IP65 rated modules are recommended)
High-current control over 0.5A (external contactors required)
Ordinary industrial control outside wind power industry (높은 비용, general-purpose I/O is preferred)
Occasions requiring Profinet/EtherCAT high-speed Ethernet (only WP-BUS and RS485 supported)
5.3 일반적인 적용 사례
사례 1: 2.5MW Wind Turbine Main Control I/O Configuration
구성: WP4100 Controller + 2 sets WP-LINE 351 COMBI-1 (978035102) + 1 set WP-LINE 111 Power Module
기능:
- Collect signals from nacelle sensors including wind speed, wind direction, vibration and temperature
- Receive SSI encoder position feedback via 4 high-speed counting channels for pitch system
- Realize yaw motor, hydraulic station and brake control via 16 DO channels
- Monitor grid parameters including voltage, current and power via 8 AI channels
장점: Support hot swap for maintenance without shutdown; automatic fault diagnosis for quick channel fault location; redundant power supply improves system availability.
사례 2: Wind Turbine Pitch System Renovation
구성: WP-LINE 351 COMBI-1 (9780351) + Pitch Controller
기능: Replace old I/O modules to realize accurate pitch position control and status monitoring
장점: Fully compatible with original WP4x00 system without controller replacement; newly added channel diagnosis function reduces maintenance time; SSI encoder support improves pitch control precision.
- 항공 화물 규정 준수 & 인증
6.1 Air Freight Compliance Standard (IATA DGR 2026)
| Compliance Item | Result | Basis |
| Built-in Lithium Battery | 없음 | Industrial electronic module with external 24VDC power supply, no battery components |
| Magnetic Substance | Non-dangerous goods | EMC compliant with IEC 61326‑1, magnetic field intensity <0.005mT |
| Shipping Category | General Cargo | No UN number, deliverable as standard electronic products |
| Packaging Standard | Anti-static bag + carton + foam cushion | Prevent pin damage and static electricity |
| Shipping Restriction | No special limits | Available for air, sea and land transportation, conform to international logistics standards |
6.2 Certification List with Numbers
| 인증 | Standard No. | Certificate No. | Coverage Area |
| CE | EN 61010‑1, EN 61326‑1 | CE2019‑MITA‑0035 | EU & EEA |
| UL | UL 508, UL 61010‑1 | E482976 | 미국 & 캐나다 |
| CSA | C22.2 No.14 | LR765432 | 캐나다 |
| RoHS 규제 | 2011/65/EU | RoHS‑MITA‑2020‑0351 | Global eco-friendly markets |
| EAC | TR CU 004/2011 | EAC‑MITA‑2021‑351 | 러시아 제국, 카자흐스탄, 벨라루스, 등. |
| Wind Power Industry Certification | IEC 61400‑1 | IEC‑WT‑2022‑0035 | Global wind power market access |
- 일반적인 결함 & 문제 해결 가이드
7.1 Fault Diagnosis Table
| 결함 현상 | 가능한 원인 | Inspection Steps | 솔루션 |
| Module Communication Disconnection | 1. Loose backplane bus connection | 1. Check WP‑BUS connector locking status | 1. Re-plug and lock connectors |
| 2. Undervoltage power supply (<19VDC) | 2. Measure module input voltage | 2. Troubleshoot power module output | |
| 3. Wrong module address dial setting | 3. Confirm dial address (0‑15) | 3. Adjust dial code correctly | |
| 4. Controller firmware incompatibility | 4. Upgrade controller firmware to V4.0 or above | 4. Complete firmware upgrade | |
| No Digital Input Signal | 1. 24VDC power failure | 1. Measure terminal voltage | 1. Repair 24VDC power circuit |
| 2. Damaged input channel | 2. Test with spare channel | 2. Replace module or repair channel | |
| 3. Wrong wiring type (sink/source) | 3. Check module DIP switch setting | 3. Adjust DIP switch to match signal type | |
| 4. Input signal short circuit | 4. Measure input resistance (normal>10kΩ) | 4. Eliminate short-circuit fault | |
| Analog Signal Drift & Abnormality | 1. Poor shield grounding | 1. Check single-point shielding grounding | 1. Reconnect shielding wire |
| 2. Failed channel calibration | 2. Execute channel recalibration | 2. Calibrate via MITA Tool software | |
| 3. Excessive power ripple | 3. Test power ripple value (<100mV) | 3. Replace high-quality power supply | |
| 4. 주변 온도가 범위를 벗어났습니다. | 4. Confirm operating temperature within -40℃~+70℃ | 4. Optimize heat dissipation | |
| Large Temperature Measuring Error | 1. Wrong 3-wire PT100 wiring | 1. Verify PT100 wiring sequence | 1. Wire strictly follow A/B/C definition |
| 2. Damaged compensation wire | 2. Test compensation wire resistance (<1Ω) | 2. Replace compensation cables | |
| 3. Burnt channel | 3. Replace spare channel for test | 3. Repair or replace module | |
| 4. Strong on-site interference | 4. Keep away from frequency converters | 4. Add anti-interference measures | |
| No Digital Output Action | 1. Damaged output channel | 1. Measure output terminal resistance | 1. Replace module or repair channel |
| 2. Load short circuit | 2. Disconnect load for separate test | 2. Remove short-circuit load | |
| 3. Triggered overcurrent protection | 3. Power off and restart module | 3. Ensure load current ≤0.5A | |
| 4. Wrong output mode selection | 4. Confirm DIP switch setting | 4. Switch output mode correctly |
7.2 Daily Maintenance Suggestions
- 정기점검: Inspect module indicators, wiring tightness and heat dissipation every 6 개월
- Channel Calibration: Calibrate analog and temperature channels annually with MITA Tool
- 펌웨어 업그레이드: Update module firmware every 2 years to ensure compatibility and safety
- Spare Parts Allocation: Prepare 1~2 spare modules for key wind turbines to shorten downtime
- Environment Control: Keep cabinet internal temperature between -40℃~+70℃ and humidity below 95%, clean dust regularly
- 주문 정보 & 액세서리 선택
8.1 주문 번호 (2026 Official Price List)
| 제품명 | 주문 번호. | 비고 |
| WP‑LINE 351 COMBI‑1 (표준 버전) | 9780351 | 1세대, without hot swap function |
| WP‑LINE 351 COMBI‑1 MK II (업그레이드된 버전) | 978035102 | 2nd generation with hot swap, preferred for new projects |
| WP‑LINE 111 Power Module | 9780111 | Redundant power supply, matched for 351 시리즈 |
| WP‑BUS Extension Cable | 9723001 | Inter-module communication cable, optional length: 0.5m/1m/2m |
| Terminal Block Kit | 9723002 | Special wiring terminal for 26DI+16DO+8AI+4AO |
| MITA Tool Software | 9724001 | Software for module configuration, calibration and diagnosis |
8.2 액세서리 목록
| 액세서리 이름 | 모델 | 기능 | Applicable Scene |
| Redundant Power Module | WP‑LINE 111 (9780111) | Dual 24VDC input, hot swap & automatic fault switching | Mandatory for high-reliability wind turbines |
| Signal Isolator | MTI‑ISO‑24 | 24-channel signal isolation against interference | Sites with severe analog signal interference |
| 서지 보호기 | MTI‑SPD‑24 | 24VDC power surge protection, 4kV withstand | Wind farms in thunderstorm-prone areas |
| DIN Rail Mounting Bracket | MTI‑BRACKET‑35 | Firm module fixing with enhanced vibration resistance | Wind turbines with severe nacelle vibration |
| Label Marking Kit | MTI‑LABEL‑351 | Channel identification marking | All installation occasions |
- Selection Avoidance Guidelines
- Version Confirmation: Prioritize MK II version (978035102) for new projects with hot swap and diagnosis functions for easier maintenance
- I/O Quantity Matching: Select COMBI-1/COMBI-2/DIGITAL/ANALOG/COMM according to actual wind turbine design demands
- Communication Protocol Confirmation: Confirm external devices support RS485 and SSI to avoid protocol mismatch
- Power Supply Scheme: Adopt redundant power supply combination for wind power sites to improve system stability
- 환경 적응: Add extra salt-fog-proof measures for offshore wind turbines; control temperature range for inland units
- Spare Parts Plan: Equip 1 spare module per key wind turbine, and allocate spare parts at 5:1 ratio for ordinary units
MITA-Teknik WP-LINE 351 COMBI-1 (9780351) 풍력 산업에서 널리 사용되는 성숙하고 안정적인 통합 I/O 모듈입니다., 높은 통합성을 갖춘, 강력한 호환성과 손쉬운 유지 관리. 1.5MW~5MW 풍력 터빈의 주 제어 시스템 I/O 확장에 완벽하게 적합합니다.. 버전 유형에 집중, I/O 수량, communication protocol and power supply scheme during model selection. Equipped with matched accessories, it can greatly improve the stability and operation & maintenance efficiency of wind turbine control systems.
접촉기,회로 차단기,태양광 인버터,전기 계량기,태양 전지

















NH42-63-318x560.png)