Mitsubishi Q68ADIELS Current Analog Input Module

Only for current input (4-20엄마 / 0-20엄마), 8 채널, AI module dedicated to MELSEC-Q series; comparison within the same series: Q68ADV is the 8-channel voltage input module, and Q64AD is the 4-channel module with switchable voltage/current input. Core Specifications Model: Q68ADI Channels: 8CH, current input only, voltage signal input is not supported Input range: DC ...

  • 제품 세부정보

Only for current input (4-20엄마 / 0-20엄마), 8 채널, AI module dedicated to MELSEC-Q series; comparison within the same series: Q68ADV is the 8-channel voltage 입력 모듈, and Q64AD is the 4-channel module with switchable voltage/current input.

핵심사양

모델: Q68ADI

채널: 8CH, current input only, voltage signal input is not supported

Input range: DC 0~20mA (4~20mA transmitters are widely used)

Input resistance: 250오 (built-in sampling resistor; do NOT add an extra 250Ω resistor externally)

Occupied I/O points: 16 전철기

5VDC backplane power consumption: 0.64에이

Conversion speed: 80채널당 μs; an additional 160μs total conversion time is required when temperature drift compensation is enabled

정확성: ±0.1%FS at 25±5℃; ±0.3%FS with temperature drift compensation, ±0.4%FS without compensation

Resolution modes (selected by software)

Normal mode: -4096~+4095 (0~20mA full scale corresponds to 0~4000)

High-resolution mode: -12288~+12287 (0~20mA full scale corresponds to 0~12000)

Maximum allowable input current: ±30mA (permanent damage may occur if exceeded)

격리: Optocoupler isolation between module terminals and PLC power supply; no isolation between channels (crosstalk may occur when multiple transmitters share the same ground)

내전압: AC500V용 1 분 (terminal side vs PLC power supply side)

치수: 27.4(여) × 98(시간) × 90(디) mm; 무게: 0.19kg

인증: CE, UL/cUL, UKCA; marine certifications ABS/BV/DNV, 등.

📌 Model Code Explanation

큐: MELSEC-Q series PLC

68: 8-채널 아날로그

에이: 비슷한 물건

디: 디지털 (A/D conversion)

나: 입력, I = Current (V = Voltage for Q68ADV)

🧩 Software Configuration

Configuration software: GX 웍스2 / GX Developer + GX Configurator-AD (dedicated analog configuration tool, recommended to reduce heavy FROM/TO instruction programming)

Configurable items: Channel enable/disable, 범위 (0~20mA), resolution mode, temperature drift compensation, moving average filtering, offset & gain calibration

데이터 저장: Raw A/D converted values are stored in the module buffer memory (BFM); the PLC reads data via FROM instructions

Common 4-20mA Conversion (High-resolution mode, 0~12000)

4mA → 2400

20mA → 12000

Span: 9600 (corresponds to 16mA)

Engineering conversion formula: Engineering value = (Raw value 2400) / 9600 × (Upper range limit − Lower range limit) + Lower range limit

🔌 배선 지침 (일반적인 함정)

  1. 2-wire transmitter (가장 일반적인): Transmitter positive to module I+, transmitter negative to module I−; transmitters are powered by external 24VDC. The module does NOT supply power to transmitters.
  2. 4-wire transmitter: Connect the two signal current wires to I+/I− of the corresponding channel; power supply is independently wired to 24VDC.
  3. No inter-channel isolation: For multi-signal applications, single-point grounding on the transmitter side is recommended to avoid ground loops and unstable readings.
  4. Shielded cable: The shield of analog cable shall be grounded at one end only (ground at transmitter side, floating at PLC side).
  5. Prohibition: Do not connect an extra 250Ω resistor in parallel externally. The built-in 250Ω resistor will cause abnormal readings after parallel connection.

⚠️ Replacement & 선택 비교

모델채널신호 유형
Q68ADI8CHCurrent only, 0~20mA
Q68ADV8CHVoltage only (0~10V, 등.)
Q64AD4CHVoltage/current selectable per channel
Q68AD-G8CH, isolated version with inter-channel isolation, 더 높은 비용

교체 알림: Q68ADI cannot directly replace Q68ADV. One is for current and the other for voltage, with completely different internal circuits.

🛠️ Common Troubleshooting

  1. Fixed reading at 0: No power supply to transmitter, 끊어진 전선, or channel disabled in software
  2. Fluctuating and unstable readings: Ground loop interference, shield grounded at both ends, cables routed together with power cables, inter-channel crosstalk
  3. Reading stuck at full scale: Short-circuited signal wire, faulty transmitter, input current exceeding 20mA
  4. Severe drift at low/high temperature: Temperature drift compensation function not enabled
  5. Module ERR light on: Incorrect buffer memory parameter settings, wrong FROM/TO read/write addresses, poor contact between module and base unit

응용 시나리오 미쓰비시 Q68ADI (For 4-20mA/0-20mA Current Transmitters, 8-Channel AI for Q Series)

Matched with SHAKO solenoid valve pneumatic circuits mentioned previously: Q68ADI collects process values such as pressure and flow; the PLC executes PID/logic calculation and drives SD90822DJSN coils via output points to control PU520/BM520 pneumatic valves, forming closed-loop pneumatic regulation systems.

대본 1: Pneumatic Automation Circuits (Most common with SHAKO solenoid valves)

Collected signals: Main air supply pipe pressure, branch pipe pressure, vacuum negative pressure, filter differential pressure, air receiver tank pressure (4-20mA pressure transmitters)

제어 논리: Open air inlet solenoid valve when pressure is below lower limit; open pressure relief valve for overpressure; PID constant pressure regulation

일반적인 장비: Transfer machines, 공구 설비, welding jigs, vacuum adsorption equipment, valve island systems

특징: Mostly 2-wire pressure transmitters which perfectly match Q68ADI; 8 channels support simultaneous multi-point pressure acquisition and centralized monitoring

대본 2: 포장기계 (Horizontal flow wrappers, vertical form-fill-seal machines, heat sealers)

Collected signals: Heat sealing temperature (4-20mA temperature transmitter), hopper level, air supply pressure, film tension, ink tank liquid level

인터록 제어: Pneumatic cutting cylinders, pressure rollers, material stop solenoid valves (SHAKO PU520) interlocked by temperature and pressure values

장점: Fast conversion speed of 80μs per channel suitable for high-frequency, short-cycle packaging processes; standardized wiring with universal 4-20mA 2-wire transmitters

대본 3: 수처리, RO Reverse Osmosis & Dosing Systems

Collected signals: Liquid level (submersible level transmitter), 흐름 (electromagnetic/vortex flowmeter), PH/ORP transmitter, 흐림, chemical dosing flow, pre-membrane and post-membrane differential pressure

인터록 제어: On-off control for inlet, concentrate and dosing pneumatic/electric valves, 흐름 합산, high/low liquid level interlock protection

Working condition: Current loop is preferred in humid sites for better anti-interference performance than voltage signals; Q68ADI is suitable for multi-point process acquisition

대본 4: 압출, 사출 성형 & Rubber and Plastic Auxiliary Machines (Material loaders, pelletizers, extrusion lines)

Collected signals: Melt pressure, barrel temperature, oil temperature, vacuum feeding negative pressure, hopper level, cooling water flow

제어 논리: Interlock feeding pneumatic valves and blow cleaning solenoid valves based on negative pressure and pressure; alarm and shutdown on overpressure

Working condition: Stable long-distance transmission of current signals in high-temperature and dusty workshops

대본 5: 3C Non-Standard Automation, Testing Machines and Assembly Equipment

Collected signals: Press-fitting force (4-20mA force sensor), test air pressure, leak detection differential pressure, fixture clamping pressure

기능: Press-fitting force monitoring, air tightness leak judgment, OK/NG sorting; pressure curve recording and MES data upload

설명: Transmitters are centrally arranged in clean workshops. The high-density 8-channel design saves slot space. Double-solenoid valves are used to maintain station status.

대본 6: 공조, Clean Rooms, Fan Coils and Purification Air Conditioning

Collected signals: Duct differential pressure, static pressure, 온도 & humidity transmitter, water flow, temperature difference between inlet and outlet of chiller

제어 논리: Pneumatic damper actuators and chilled water circuit regulating valves, constant static pressure, 일정한 온도 & 습도 PID 조절

대본 7: Material Conveying, Sorting Lines and Warehouse Conveying Lines

Collected signals: Belt weigher flow, silo level, dust removal negative pressure, air supply pressure

인터록 로직: Trigger feeding/discharging pneumatic valves by high/low level; alarm when dust removal negative pressure is insufficient

대본 8: Small-Scale Chemical Industry, Fluid Proportioning & Quantitative Dosing Systems

Collected signals: Flow transmitter, tank liquid level, medium pressure

기능: Flow totalization, quantitative feeding, proportion control, over-limit interlock shutoff; suitable for multi-component batching with simultaneous multi-channel flow collection

대본 9: 펌프장, Air Compressor Rooms and Centralized Air Supply Station Monitoring

Collected signals: Air compressor discharge pressure, air receiver pressure, pipeline flow, cooling water temperature, filter differential pressure

기능: Load/unload linkage of multiple air compressors, overpressure protection, pressure logging, alarm upload to SCADA

선택 지침 (When to prefer Q68ADI and when to avoid it)

Suitable applications:

All measuring points use 4-20mA 2-wire / 4-wire transmitters (압력, 수준, 흐름, 온도, force, PH)

8-channel current acquisition required, high channel density on a single module and cost-sensitive

Long signal transmission distance or sites with heavy electromagnetic interference (current loop has better anti-interference performance than voltage signals)

Unsuitable (avoid selection):

0~10V, ±5V voltage signal acquisition required → Select Q68ADV

Electrical isolation between channels required (chemical explosion-proof, high interference sites) → Select isolated Q68AD-G

Flexible switching between voltage and current per channel for scattered measuring points → Select Q64AD

Mitsubishi Current Analog Input (일체 포함) Module List

Two categories: 【Current-only modules for 4~20mA / 0~20mA】, 【Dual-purpose voltage/current modules with current range selectable by software】, sorted by MELSEC-Q / iQ-R / 엘 / FX (iQ-F) 시리즈

  1. MELSEC-Q Series (Q68ADI included)

Current-only Modules (Current input only, voltage not supported)

Dual-purpose Voltage/Current Modules (Range switchable by software for current acquisition)

모델채널설명비고
Q64AD4CHVoltage/current selectable80μs/ch, 범용
Q64ADH4CHHigh-speed voltage/current20渭μs/ch, 고해상도
Q64AD-GH4CHIsolated voltage/currentInter-channel isolation
Q68AD-G8CHIsolated voltage/currentChannel isolation for high-interference sites
Q62AD-DGH2CHIsolated with signal conditioning2-channel isolated AI
Q64AD2DA4AI+2AOMixed module, AI supports currentCombined analog input & 산출

There is no Q64ADI (4-channel current-only module) for Q series; Q68ADI is the only 8-channel current-only option.

  1. MELSEC iQ-R Series (New-generation RCPU)

Current-only Modules

모델채널설명비고
R60AD44CHVoltage/current selectableScrew terminal general model
R60ADH44CHHigh-speed voltage/current1渭s/ch high-speed sampling
R60AD8-G8CHIsolated voltage/current40-핀
R60AD16-G16CHIsolated voltage/current고밀도 16 채널

Dual-purpose Voltage/Current Modules (Current range selectable)

| R60AD4 | 4CH | Voltage/current selectable | Screw terminal general model |

| R60ADH4 | 4CH | High-speed voltage/current | 1μs/ch high-speed sampling |

| R60AD8-G | 8CH | Isolated voltage/current | 40-핀 |

| R60AD16-G | 16CH | Isolated voltage/current | 고밀도 16 채널 |

III. MELSEC-L Series (LCPU)

No dedicated current-only modules for L series; all modules support both voltage and current

| L60AD4 | 4CH | Switchable voltage / 현재의 |

| L60AD8 | 8CH | Switchable voltage / 현재의 |

| L60AD16 | 16CH | Switchable voltage / 현재의 |

| L60AD4-G | 4CH | Isolated voltage / 현재의 |

| L60MD4-G | 4CH | 다기능 (voltage/current/RTD/TC) |

  1. FX / iQ-F (FX5U, FX3U) Compact PLC Analog Adapters

FX series uses ADP adapters instead of backplane modules; all dual-purpose voltage/current

| FX5-4AD-ADP | 4CH | FX5U dedicated, supports 4-20mA |

| FX3U-4AD-ADP | 4CH | FX3U, supports 4-20mA |

| FX3UC-4AD | 4CH | Module type for FX3UC |

| FX2N-8AD | 8CH | Old FX2N (단종) |

  1. 빠른 선택 참조 (For procurement & 대사)
  2. Q68ADI (큐) ↔ R60ADI8 (아르 자형): Equivalent function, 8-channel current-only
  3. HART smart transmitters required → R60ADI8-HA (iQ-R)
  4. Heavy interference, chemical or explosion-proof cabinet with channel isolation requirement: Q68AD-G (Q dual-purpose) / R60ADI8-HA, R60AD6-DG (R isolated current-only)
  5. Small quantity of 4 measuring points requiring flexible voltage/current switching: Q64AD / R60AD4
  6. Critical Notes to Avoid Mistakes

Q68ADI supports current only and cannot collect 0~10V voltage signals; Q68ADV supports voltage only

For dual-purpose modules (Q64AD, R60AD4), the current mode must be selected in software parameters for correct 4-20mA acquisition

All Mitsubishi current AI modules have built-in 250Ω sampling resistors, never connect an extra 250Ω resistor externally