PHOENIX CONTACT PLC-BSC-24DC/21

Model Definition Complete Model: PLC-BSC-24DC/21 Order Number: 2966016 브랜드 시리즈: Phoenix Contact PLC-INTERFACE ultra-slim relay base Model Breakdown PLC: Base for PLC interface relay module BSC: Basic economical base with screw connection 24DC: Rated control coil voltage DC24V 21: 1 전환 연락처 (1아니요 + 1NC, 1PDT single-pole double-throw) 제품 설명: Base only, relay insert not ...

  • 제품 세부정보

모델 정의

  1. 완전한 모델: PLC-BSC-24DC/21
  2. 주문 번호: 2966016
  3. 브랜드 시리즈: 피닉스컨택트 PLC-INTERFACE ultra-slim relay base
  4. 모델 분석

PLC: Base for PLC interface relay module

BSC: Basic economical base with screw connection

24DC: Rated control coil voltage DC24V

21: 1 전환 연락처 (1아니요 + 1NC, 1PDT single-pole double-throw)

  1. 제품 설명: Base only, relay insert not included. Must be used with matching pluggable relays (2961105 / 2961118).
  2. Electrical Specifications of Control Side Input (A1+/A2-)
  3. 정격 제어 전압: 24 DC에서
  4. 작동 전압 범위: 19.2 V DC ~ 30 DC에서
  5. Built-in Protection Circuit: Freewheeling damping diode + reverse polarity protection diode to prevent PLC output burnout from reverse connection
  6. 상태 표시기: Integrated yellow LED on base, lights steadily when coil is energized
  7. Input Power Consumption: 대략. 1.1 여
  8. Minimum Driving Current: 5 엄마, directly compatible with PLC NPN/PNP transistor outputs (S7-1200/1500, 미쓰비시, 혁신, 등.)
  9. Rated Parameters of Load-side Contacts (12/11 흔한, 14 평상시 열림, 12 평상시 닫힘)

3.1 General Load Ratings

Maximum Switching Voltage: 250 뷔와 / 30 DC에서

Rated Continuous Thermal Current Ith: 6 에이

AC-15 Inductive Load (Contactor Coils): 6 에이 / 250 뷔와

DC-13 Inductive Load (솔레노이드 밸브): 3 에이 / 24 DC에서

3.2 격리 & 내전압

Isolation Withstand Voltage (Coil to Contacts): 4 kV AC for 1 분

Withstand Voltage across Open Contacts: 2 kV AC

절연저항 (DC 500 V Test): ≥10⁹ Ω

3.3 전기적 내구성 (with Original Phoenix Relay Insert)

6 에이 / 250 뷔와: 100,000 운영

3 에이 / 24 DC에서: 200,000 운영

3.4 문의 양식: 1PDT Single-Pole Double-Throw (11 흔한, 14 아니요, 12 NC)

  1. Mechanical Dimensions & 설치
  2. 너비: 6.2 mm (ultra-slim design saves DIN rail space, zero-gap side-by-side mounting supported)
  3. 전체 치수: W6.2 mm × H94 mm × D80 mm
  4. 마운팅 레일: Standard DIN NS35/7.5 rail
  5. Housing Flame Retardancy: UL94 V0
  6. 색상: Base body grey-green, relay latch orange
  7. 무게: 대략. 45 g
  8. Terminal Specifications (All M3 Screw Terminals)
  9. Applicable Wires:

Solid single-core wire: 0.14~2.5mm²

Stranded multi-core wire: 0.14~2.5mm²; 최대. 2.5 mm² with ferrule terminals

AWG Range: 26 AWG ~ 14 AWG

  1. Screw Torque: 0.6~0.8 N·m
  2. Wire Stripping Length: 8 mm
  3. Terminal Partition

왼쪽: Control circuit A1+, A2(connect to PLC outputs)

Right Side: Load circuit 12(NC), 11(COM), 14(아니요)

  1. 주변 조건 & 승인
  2. 작동 온도: -25 ℃ ~ +60 ℃
  3. 저장 & 운송 온도: -40 ℃ ~ +85 ℃
  4. 오염도: 3, for indoor industrial control cabinet installation
  5. 인증: CE, cULus, VDE, GL Marine Approval, RoHS Compliant
  6. EMC Class: Class A industrial equipment
  7. Matching Relay Inserts (Must Be Ordered Separately)
Relay Insert Model코일 전압접점 용량Compatible Base
2961105DC 24 다섯6 A 1PDT2966016
2961118DC 24 V with LED indicator6 A 1PDT2966016
  1. 일반적인 애플리케이션 시나리오
  2. PLC digital output isolation to drive small contactors, solenoid valves and indicator lights
  3. IO signal transfer and separation of strong/weak current on automated production lines
  4. On-off control of small loads for machine tools, packaging equipment and assembly lines
  5. Ultra-slim modular signal expansion for high-density IO cabinets
  6. Series Model Selection Comparison
모델주문 번호.너비Number of Contact Sets코일 전압
PLC-BSC-24DC/2129660166.2 mm1 changeoverDC 24 다섯
PLC-BSC-24DC/21-21296701514 mm2 changeoverDC 24 다섯
PLC-BSC-230UC/2129660296.2 mm1 changeoverAC/DC 230 다섯
  1. Brief Wiring Logic
  2. 연결하다 24 V DC PLC output to base terminals A1(+) 그리고 A2(-); LED illuminates and relay pulls in.
  3. Pull-in State: 11(COM) 14(아니요) 닫은; 11 disconnected from 12(NC).
  4. De-energized State: 11(COM) 12(NC) 닫은; 11 disconnected from 14(아니요).
  5. Load Circuit: Connect AC220 V / DC24 V loads to COM+NO or COM+NC for switching control.
  6. Troubleshooting Guidelines
  7. LED 꺼짐: No PLC output, reversed A1/A2 wiring, 느슨한 단자
  8. LED on but load inactive: Damaged relay insert, loose contact wiring, open-circuit load
  9. Frequent contact ablation: Load current exceeds 6 에이; external auxiliary contactor required for capacity expansion
  10. Unintended operation: No absorption component for inductive PLC loads; freewheeling diode can be paralleled on the base side

Application Scenarios of PHOENIX CONTACT PLC-BSC-24DC/21 (2966016)

This 6.2 mm ultra-slim PLC interface relay base mainly realizes PLC transistor output isolation & transfer, strong/weak current separation and small load switching for compact control cabinet wiring. It fits all 24 V DC PLC digital output applications, categorized into industry segments, equipment types and cabinet internal functions as below:

  1. General Automation OEM Equipment Applications

1.1 공작기계 & Metal Processing Equipment

CNC 선반, 머시닝 센터, 그라인더, punch presses: PLC outputs drive cooling solenoid valves, 윤활 펌프, tool magazine cylinders, indicator lights and small contactor coils

Bending machines, 절단기: Control pneumatic clamps, safety door warning lights and alarm buzzers

장점: Ultra-slim to save cabinet space; pluggable relay allows fast replacement without wire disconnection during machine breakdowns

1.2 포장, 충전재 & Food Processing Machinery

Beverage filling machines, 라벨러, flow wrapping machines, 정렬 & rejection equipment

Control material distributing cylinders, photoelectric rejection valves, conveyor start/stop, fault warning lights and hot air blowers

Suitable for clean-room control cabinets; screw terminals resist vibration and maintain stable service life under frequent switching cycles

1.3 3C Electronics, 리튬 배터리 & PV Equipment

SMT placement machines, 디스펜서, lithium battery filling/sealing equipment, PV module production lines

Drive micro solenoid valves, vacuum generators, sensor indicator lights and small signal contactors

High-density PLC output points fit the 6.2 mm narrow design for compact arrangement to solve space shortage in IO cabinets

1.4 운반 & 물류장비

벨트 컨베이어, 롤러 라인, 자동화 창고, 라인 정렬, control cabinets matched with AGVs

Control track switch cylinders, stopper cylinders, position indicator lights, audio-visual fault alarms and guard lock prompts

  1. Discrete Manufacturing Production Line Applications
  2. Automotive Assembly Lines

용접, coating and final assembly stations: Solenoid valves for robot clamps, station indicator lights, safety bypass prompts and pneumatic clamping mechanisms. Isolates heavy interference from welding machines to protect PLC output points from breakdown induced by inductive loads.

  1. 고무 & Plastic Molding Equipment

사출 성형기, 압출기: Barrel cooling fans, material suction solenoid valves, mold temperature controller signal switching and safety door status indicator lights

  1. 인쇄 & 섬유기계

Printing presses, warp knitting machines, 인쇄 & 염색 장비: Tension cylinders, ink valves, shutdown alarms and fabric deviation correction actuators

  1. Municipal, 수처리 & HVAC Integrated Control Cabinets
  2. Sewage treatment plants, water supply pump station control cabinets: Bar screen alarms, electric valve signals, liquid level indicator lights and auxiliary control of submersible pumps
  3. 중앙 에어컨 & air purification units: Air damper actuators, humidifier solenoid valves and differential pressure alarm lights
  4. Building intelligent control: Lighting zoning control, 배기 팬, access status feedback and fire linkage signal transfer

특징: Designed for 24/7 지속적인 작동; built-in freewheeling diode suppresses solenoid valve surge voltage to protect PLC I/O cards

  1. 새로운 에너지, 에너지 저장 & Test Equipment
  2. Control cabinets matched with PCS energy storage converters, lithium battery testing equipment and auxiliary cabinets of PV inverters
  3. High/low voltage electrical test benches and aging test equipment: Signal switching for test points, indicator lights and micro solenoid valves

넓은 작동 온도 범위 (-25 ℃ ~ +60 ℃) fits indoor machine rooms and constant-temperature outdoor control cabinets

  1. 철도 운송 & Small Construction Machinery Matching

Metro platform screen door control cabinets, electrical boxes for small construction machinery (로더, 절단기)

Drive warning lights, electromagnetic directional valves and operation panel indicator lights; vibration-resistant screw terminals prevent loose wiring

  1. Typical Internal Cabinet Functional Applications (General Retrofit & Project Matching)
  2. PLC Output Isolation Protection (핵심 기능)

24 V transistor PLCs including Siemens S7-1200/1500, 알렌 브래들리, 미쓰비시, Inovance and Xinje only supply 0.5 A output current, insufficient to directly drive solenoid valves or contactors. This relay expands the switching capacity to 6 A and isolates back EMF from inductive loads to avoid I/O point burnout.

  1. Physical Separation of Strong & Weak Current Signals

4 kV insulation isolation between 24 V weak-current PLC control circuits and 220 V AC load circuits prevents high voltage back-feed to controllers and improves equipment safety rating.

  1. High-Density IO Cabinet Wiring

6.2 mm ultra-slim width supports zero-gap side-by-side installation, doubling the number of relays on the same DIN rail length, ideal for centralized cabinets with massive I/O points.

  1. Signal Distribution & Contact Conversion

1 set of changeover contacts (1아니요+1NC) enables one PLC signal to control two different loads simultaneously; NC contact can be used for fault alarm circuits.

  1. Equipment Retrofit & Old Cabinet Capacity Expansion

Replaces standard 14 mm wide relay bases to save rail space when existing cabinet space is limited. Pluggable relay design allows on-site maintenance without wire disconnection and reduces downtime.

  1. Not Recommended Application Scenarios (Application Limitations)
  2. 안전 회로, emergency stop and safety door interlocks (440R series safety relays are required; this product has no force-guided contacts and fails to meet PL e safety certification)
  3. High-power loads (single channel exceeding 6 A AC-15 / 3 A DC-13; external high-capacity contactors required for capacity expansion)
  4. Outdoor unenclosed enclosures (IP20 보호 등급; must be installed inside standard sealed control cabinets)
  5. Unshielded cabinets with heavy interference from high-frequency high-voltage large inverters (surge suppressors must be added for matching use)

Complete Mounting Instructions for PHOENIX CONTACT PLC-BSC-24DC/21 (2966016)

  1. Basic Mounting Type: Standard DIN Rail Snap-in Installation (Only Official Mounting Method)
  2. Applicable Rail Specification

Only compatible with national/European standard NS 35/7.5 DIN mounting rail (35 mm 폭, 7.5 mm height). Direct panel mounting via drilled holes or wall screw mounting is not supported.

  1. Arrangement Characteristics

Zero-gap dense side-by-side mounting available; 그만큼 6.2 mm slim design requires no reserved heat dissipation gap for high-density IO cabinet layout. Install PLC-ATP insulating partitions between adjacent modules with mixed high/low voltage circuits for reinforced electrical isolation.

  1. Unrestricted Mounting Orientation

Can be mounted horizontally, laterally or vertically with no mandatory angle; only ensure adequate ventilation inside the control cabinet.

  1. Step-by-Step Rail Assembly & 분해

2.1 Base Installation Steps

  1. Remove oil stains and metal debris from the DIN rail surface and fix the rail firmly to the cabinet mounting plate.
  2. Hook the upper rear latch of the base onto the top edge of the DIN rail slot.
  3. Press down the lower half of the base until an audible click confirms the spring latch locks the base fully against the rail.
  4. Install multiple modules side by side seamlessly in sequence.
  5. Fit end stoppers at both rail ends if positioning is required to prevent sliding caused by vibration.

2.2 Base Removal Steps

  1. Cut off power and disconnect all wiring.
  2. Insert a flathead screwdriver into the spring latch slot at the bottom of the base.
  3. Pry downwards to release the lower locking mechanism.
  4. Tilt the bottom edge outward and lift the base up to disengage from the upper rail edge for removal.
  5. Relay Insert Plug-in Installation (Base Matching Operation)

This product is base-only and must be paired with 2961105 / 2961118 relay inserts:

  1. Align the relay with the upper slot of the base and press straight down for insertion.
  2. The orange latch automatically locks to prevent loosening under vibration.
  3. Removal: Pinch the orange latch to flip outward, then pull the relay insert upward for quick replacement without disconnecting wires.
  4. Terminal Wiring Installation (M3 Screw Connection)
  5. Standard wire stripping length: Fixed at 8 mm; excessive length risks short circuits, insufficient length causes poor contact.
  6. Applicable Cables: 0.14~2.5 mm² solid/stranded wires, AWG26~14; ferrule terminals are recommended for stranded wires.
  7. 조임 토크: 0.6~0.8 N·m; excessive torque strips screws, insufficient torque leads to heat and poor contact.
  8. Terminal Partition: Left side A1/A2 (PLC 제어 회로); Right side 11/12/14 (load contact circuit). Clear zoning facilitates wiring.
  9. Optional Matching Mounting Accessories
  10. PLC-ATP Insulating Partition: Install between adjacent modules where one side carries 220 V high voltage and the other carries 24 V low voltage to strengthen electrical isolation.
  11. FBST Plug-in Bridge Connectors: 공유하다 24 V power supply for multiple modules to parallel A1/A2 terminals in batches and reduce redundant wiring.
  12. DIN Rail End Stoppers: Secure both ends of a full row of modules to prevent sliding and dropping during equipment transportation and vibration.
  13. Mounting Environment & 제한
  14. IP20 보호 등급; only for installation inside sealed control cabinets. Outdoor and unenclosed box installation prohibited.
  15. 작동 주변 온도: -25 ℃ ~ +60 ℃; reserve ≥10 mm clearance above modules for heat dissipation.
  16. Keep away from heat-intensive and high-interference devices such as inverters and contactors; avoid tight fitting with high-power heat sources.
  17. Do not install in areas with direct exposure to water mist, heavy dust or corrosive gas.
  18. Mounting Prohibitions
  19. Violent knocking of base or relay insert is forbidden to avoid rear latch fracture.
  20. Do not pull the base diagonally with force to prevent rail deformation and latch damage.
  21. High/low voltage modules cannot be placed closely without insulating partitions, which carries risk of dielectric breakdown and electric leakage.
  22. Exposed loose copper strands from multi-core wires at terminals are prohibited to avoid phase-to-phase short circuits.