Phoenix MCR-C-UI-UI-DCI-2810913 - 접촉기,회로 차단기,태양광 인버터,전기 계량기,태양 전지

위챗: +86-13184948252 왓츠앱: 0086-13811255435 이메일: kent@bestcontactor.com

에 대한 연락하다 |

Phoenix MCR-C-UI-UI-DCI-2810913 - 접촉기,회로 차단기,태양광 인버터,전기 계량기,태양 전지

전기 같은/

Phoenix MCR-C-UI-UI-DCI-2810913

Model Code Breakdown Explanation Code Segment Definition MCR Base series identifier: Modular Current/Voltage Converter, series of 3-way isolated signal conditioners C Dimension specification: 표준폭 (17.5mm), differs from MINI MCR series (6.2mm/12.5mm) UI Input type: Universal Input, supports 0–10V voltage & 4–20mA current signals UI Output type: Universal Output, supports 0–10V voltage & 4–20mA current ...

  • 제품 세부정보
  1. Model Code Breakdown Explanation
코드 세그먼트정의
MCRBase series identifier: Modular Current/Voltage Converter, series of 3-way isolated signal conditioners
기음Dimension specification: 표준폭 (17.5mm), differs from MINI MCR series (6.2mm/12.5mm)
UI입력 유형: Universal Input, supports 0–10V voltage & 4–20mA current signals
UI출력 유형: Universal Output, supports 0–10V voltage & 4–20mA current signals
DCI기능적 특징: DC Isolation; built-in DC/DC converter realizes 3-port isolation among Input / 산출 / 전원공급장치
2810913Unique order number: 공식적인 피닉스 part number for procurement & inventory management
  1. 핵심 사양 데이터 시트

2.1 기본 전기 사양

매개변수주목
Isolation Type3-way isolation (입력 / 산출 / 힘)Withstand voltage test: In-Out:1.5kV AC; Power-Signal:1kV AC (50헤르츠, 60에스)
Input Signal0–10V DC / 4–20mA DC맥스. 입력:30다섯 / 50엄마
출력 신호0–10V DC / 4–20mA DC맥스. 산출:15다섯 / 30엄마
Transmission Error≤0.1% FSHigh-precision signal conversion
전원공급장치18–30V DCNominal 24V DC; No-load current <30엄마
전력 소비≤900mWUnder rated operating condition
Cut-off Frequency30헤르츠3dB point, effectively suppress high-frequency interference
Step Response11ms (10%-90%)Fast signal tracking performance

2.2 기계 & 환경 사양

매개변수주목
전반적인 차원W17.5mm × H99mm × D114.5mmDIN rail mounting for space saving
설치표준 35mm DIN 레일Arbitrary installation orientation available
TerminationPlug-in screw terminal (COMBICON)Stripping length:8mm, M3 screw thread
케이블 크기Solid/Flexible:0.2–2.5mm² (AWG24–14)Compatible with various industrial cables
작동 온도.-20°C ~ +65°CWide temperature range for industrial environment
Ingress RatingIP20Indoor cabinet installation only
무게149.4g (with package)Lightweight for easy mounting

2.3 인증 & 규정 준수

인증기준주목
CE안에 61000-6-2 / 안에 61000-6-4EMC compliant
UL RecognizedUL 508Class I Div.2 Groups A-D; Class I Zone2 Group IIC
Eco-certificateEU RoHS / 중국 RoHSEFUP-50 (50-year service life for environmental compliance)
HS코드85437090For customs clearance in international trade
  1. Full Series Part Number List (MCR-C-UI-UI-DCI Family)
주문 번호.모델특징일반적인 응용
2810913MCR-C-UI-UI-DCI표준 버전, factory preset 0–10V/0–10VGeneral industrial signal isolation & conversion
2810939MCR-C-UI-UI-DCI-NCNC = No CalibrationFixed application without on-site calibration
2811284MACX MCR-UI-UIUpgraded replacement modelNew generation with improved performance
2810915MCR-C-UI-UI-450-DCIHigh-load type, 맥스. output load ≤450ΩLong-distance signal transmission & high-load occasions
2810941MCR-C-UI-UI-450-DCI-NCHigh-load without calibrationHigh-load fixed installation without trimming
  1. Cross-reference: 더 이상 사용되지 않음 & Competitor Replacement List

4.1 Internal Phoenix Replacement

구형 모델교체 모델업그레이드 하이라이트
MCR-C-UI-UI-DCI (2810913)MACX MCR-UI-UI (2811284)Narrower width(12.5mm), lower power draw, 더 빠른 응답
MCR-C-UI-UI-450-DCIMACX MCR-UI-UI-450Identical function with compact footprint

4.2 브랜드 간 동등 비교

Phoenix Model슈나이더 등가물지멘스 등가물핵심 차이점
MCR-C-UI-UI-DCI (2810913)FOXboro IMT25SITRANS P DS III피닉스:3-way isolation,1.5kV 저항, 비용 효율적
1kV isolation,15ms response1.2kV isolation,12ms response
  1. 응용 환경 & 산업 사례

5.1 권장 애플리케이션

  1. 산업 자동화: Signal isolation between PLC and field sensors/actuators to eliminate ground loop interference
  2. Process Industry: Safe transmission of analog signals for chemical, 제약, 음식 & beverage in explosion-proof environment
  3. 새로운 에너지: Pitch control monitoring for wind turbine, PV inverter signal acquisition, substation remote signaling renovation
  4. 철도 운송: Signal isolation for train control & on-board equipment with superior EMC resistance
  5. 수처리: PLC automation system for municipal water plant, safe integration of process sensor signals

5.2 권장되지 않는 애플리케이션

  1. Intrinsically Safe hazardous area (Select MCR-EX intrinsic safety series instead)
  2. Ultra-low temp (<-20℃) or ultra-high temp (>+65℃) 환경
  3. Special project requiring isolation voltage higher than 1.5kV
  4. High-frequency signal processing above 30Hz bandwidth

5.3 일반적인 적용 사례

사례 1: Automotive Production Line

애플리케이션: Signal isolation for welding robot controller & pressure transmitter

문제: Severe EMI from welding current causes distorted sensor readings

해결책: Install MCR-C-UI-UI-DCI isolator, 1.5kV galvanic isolation, conversion error<0.1% to guarantee precise pressure control

사례 2: Municipal Wastewater Treatment Plant

애플리케이션: Conversion & isolation between pH sensor and PLC analog input

문제: Different equipment ground potential drift leads to unstable output

해결책: Adopt 3-port isolation to cut ground loop; convert 0–10V sensor signal to standard 4–20mA for up to 1000m long-distance cabling

  1. 선택 팁 & 빠른 참조 규칙

빠른 선택 규칙

  1. 모델 식별: MCR-C=standard size; UI=universal I/O; DCI=DC galvanic isolation
  2. 주요 사양: 3-way isolation @1.5kV, 0–10V/4–20mA, 0.1%FS 정확도,11ms step response
  3. 업그레이드 옵션: Compact space saving → MACX MCR series PN:2811284
  4. Application Rule: Ground loop trouble →3-port isolation; long cable run →4–20mA output
  5. 항공 운송 규정 준수 & CE Certification Summary

7.1 항공 운송 규정 준수

Lithium Battery Check: No built-in lithium cell, classified as non-restricted goods without special shipping marking

Transport Classification: Complies with IATA DGR Class9, acceptable as general cargo

포장: Original factory carton preferred; ESD bag protection recommended

7.2 CE Certification Info

적용 가능한 표준: EN61000-6-2 (Immunity), EN61000-6-4 (Emission)

DOC Download: EU Declaration of Conformity available on Phoenix official website (Doc No.:083097087_04_DoC_EU.pdf)

Valid Scope: All EU member states & regions accepting CE marking

  1. 문제 해결 가이드
결함 증상근본 원인Remedy
Power LED off1. Missing power or reverse polarity1. Rewire DC supply with correct polarity
2. Supply out of 18–30V range2. Measure & adjust input to rated 24V DC
No output variation1. Improper input wiring1. Verify input wiring & 신호 유형
2. Wrong DIP switch setting2. Reconfigure DIP switches
3. Load out of specification3. Voltage output ≥10kΩ; Current output ≤500Ω
Fluctuating output1. Input signal interfered1. Single-point grounding for shield cable
2. 과도한 전원 리플2. Add power filter
3. Poor module earthing3. Secure module chassis ground
Excessive conversion error1. Zero/Span drift1. Re-trim Zero & Span (±2% adjustable)
2. Ambient temp out of rated range2. Improve cabinet ventilation
3. Mismatched load impedance3. Adjust load to specified range

Phoenix MCR‑C‑UI‑UI‑DCI (2810913) On-site Installation Manual

  1. Safety Precaution (Mandatory Reading)

보호 등급: IP20, indoor dry cabinet installation only

내전압: In-Out 1.5kV AC/60s; Power-Signal 1kV AC/60s, overvoltage withstand test prohibited

ESD 보호: Static-sensitive component; discharge body static by touching grounded metal before handling

위험 지역: Suitable for Zone2 / Class I Div.2 only; MCR‑EX IS series for Intrinsically Safe location

전원공급장치:18–30V DC (Nominal 24V DC); reverse polarity will permanently damage unit, confirm polarity prior to power-up

  1. Unpacking & 점검

2.1 포장 목록

Isolation amplifier MCR‑C‑UI‑UI‑DCI (2810913) ×1

This installation manual ×1

Factory test certificate ×1

2.2 Visual Check

No housing crack, intact snap latch, non-deformed & rust-free terminals

Confirm model & part No.: MCR‑C‑UI‑UI‑DCI / 2810913

  1. 설치환경 & Clearance Requirement

3.1 Ambient Condition

작동 온도: -20°C ~ +65°C

보관 온도: -25°C ~ +70°C

습기:10%~90% non-condensing

Min.30cm clearance away from strong EMI source (VFD, large motor, 변신 로봇)

3.2 Mounting Spacing

산: 표준 35mm DIN 레일 (EN60715), any mounting direction allowed

Side gap between adjacent modules ≥5mm

Vertical top/bottom clearance ≥20mm for heat dissipation & 유지

Install at upper/middle cabinet position; avoid dusty bottom compartment

  1. DIN Rail Mount & Dismount Steps

4.1 설치

  1. Clean DIN rail from grease & burr, ensure reliable rail grounding
  2. Flip upward the orange top latch of module
  3. Hook upper notch onto top edge of DIN rail then press down module bottom
  4. Audible click sound confirms locked & fixed without wobble

4.2 Dismounting

  1. Cut off module power & all field signals first; no live removal allowed
  2. Lift orange release latch upward
  3. Lift module bottom upward to detach from DIN rail then take out
  4. Terminal Definition & 배선사양

5.1 Terminal Pinout (Left to Right)

핀번호.마킹정의메모
1.1IN U전압 입력 (0-10V)Signal Positive
1.2IN I현재 입력 (4-20mA)Signal Positive
1.3접지 1Input CommonSignal Negative
2.1OUT U전압 출력 (0-10V)Signal Positive
2.2OUT I전류 출력 (4-20mA)Signal Positive
2.3접지 2Output CommonSignal Negative
3.124DC에서Positive Power18–30V DC
3.2접지Negative PowerSupply Ground

5.2 배선 표준

Cable strip length:8mm (too long → short circuit; too short → poor contact)

도체 크기: Solid/Flexible 0.2–2.5mm² (AWG24–14); ferrules required for stranded flexible wire

Screw torque:0.5~0.6N·m for M3 terminal, avoid over-tightening thread slip

Shield cable: Single-end cabinet grounding (transmitter end floating) to eliminate ground loop

5.3 Typical Wiring Examples

Ex1: 4–20mA Input →4–20mA Output (2-wire transmitter)

Transmitter + →1.2(IN I)

Transmitter − →1.3(GND1)

2.2(OUT I) →PLC AI+

2.3(GND2) →PLC AI−

3.1→24V DC+;3.2→24V DC−

Ex2:0–10V Input→0–10V Output (Voltage sensor)

Sensor +→1.1(IN U)

Sensor −→1.3(GND1)

2.1(OUT U)→PLC AI+

2.3(GND2)→PLC AI−

3.1→24V DC+;3.2→24V DC−

  1. DIP Switch Configuration (Factory preset for 2810913:0–10V/0–10V)

6.1 Switch Location (Side housing; remove cover to access)

S1: Input Configuration

S1‑1:OFF=0–10V; ON=4–20mA

S1‑2:OFF=Unipolar; ON=Bipolar(±5V/±10V)

S2: 출력 구성

S2‑1:OFF=0–10V; ON=4–20mA

S2‑2:OFF=Unipolar; ON=Bipolar(±5V/±10V)

6.2 Factory Default (2810913)

S1:OFF/OFF (Unipolar 0–10V Input)

S2:OFF/OFF (Unipolar 0–10V Output)

6.3 Setting Procedure

  1. Cut off power supply then remove 2 cross-head screws to open cover
  2. Toggle DIP switches as required with fully seated position
  3. Refit housing & tighten screws before power-on test
  4. Power-up & 시운전

7.1 사전 전원 검사 (필수적인)

Full wiring check: No cross-connection, short circuit or loose terminal

DC supply test: 24V DC ±10% measured across pin3.1 &3.2

Isolation test: No continuity between Input/Output/Power with multimeter continuity mode

7.2 LED 상태 표시

PWR(녹색): Steady ON=Normal Supply; OFF=Power fault/reverse polarity

달리다(녹색): Blinking=Running normally; Solid/OFF=Module malfunction

7.3 구경 측정 (Optional for high precision requirement)

Zero Adjustment: Feed zero input signal, trim ZERO potentiometer for zero output

Span Adjustment: Feed full-scale input, trim SPAN potentiometer for full-scale output

정확성: ≤0.1%FS, max temperature drift ≤±2%

  1. On-site Quick Troubleshooting

8.1 Power LED Dark

원인: 역극성, 비정상적인 전압, 느슨한 배선 | 행동: Correct polarity, 전압을 측정하다, retighten terminals

8.2 Zero Output Signal

원인: 잘못된 배선, mismatched DIP setting, 초과 적재 | 행동: 다시 배선, reset switches, check load impedance

8.3 Unstable Swinging Output

원인: Improper shield grounding, high supply ripple, nearby EMI | 행동: Single-point ground, install power filter, relocate away from interference source

8.4 Out-of-spec Accuracy

원인: Thermal drift, zero/span shift, mismatched load | 행동: Recalibrate, 환기를 개선하다, adjust load

  1. Periodic Maintenance

Every 6-month routine: Power off to clean terminal/housing, recheck screw torque & recalibrate accuracy

Forbidden operation: Hot plug/unplug, overvoltage/overtemperature running, unauthorized internal circuit disassembly

  1. 기술지원 & Alternative Part

Manufacturer Support: Phoenix Contact China

업그레이드 교체: MACX MCR‑UI‑UI (2811284):12.5mm 폭, 낮은 전력 소비, faster response speed

이전:

다음:

답장을 남겨주세요