Schmersal SRB301LC-24V 안전 계전기

Model Code Breakdown SRB: Schmersal Safety control module of PROTECT series (안전 릴레이) 301: 기본 모델, dual-channel passive input, 비상 정지 / safety gate monitoring LC: 나사식 터미널 (0.25~2.5mm²), built-in glass fuse, no electronic fuse 24V: Universal supply voltage 24V AC/DC 101163475: Unique factory order number; Alternative order number: 101165472 핵심 전기 사양 2.1 힘 ...

  • 제품 세부정보

모델 코드 분석

  1. SRB: Schmersal Safety control module of PROTECT series (안전 릴레이)
  2. 301: 기본 모델, dual-channel passive input, 비상 정지 / safety gate monitoring
  3. LC: 나사식 터미널 (0.25~2.5mm²), built-in glass fuse, no electronic fuse
  4. 24다섯: Universal supply voltage 24V AC/DC
  5. 101163475: Unique factory order number; Alternative order number: 101165472
  6. 핵심 전기 사양

2.1 전원공급장치

정격전압: Dual-purpose 24V AC/DC

DC range: 20.4~28.8V DC (-15%/+20%)

AC 50/60Hz: 20.4~26.4V AC (±10%)

소비전력: 1.7여 / 1.9버지니아

Circuit fuse: 0.5A gG glass fuse (standard for LC version)

2.2 Input Circuit (Dual-channel Monitoring)

2 independent safety inputs A/B, compatible with passive contacts: 비상 정지 버튼, safety gate switches, magnetic safety switches

Equipped with wire break detection and ground fault detection; No cross-channel short-circuit detection

Max cable length: 2500중 (2.5mm² wire, loop resistance ≤40Ω)

2.3 출력 접점 (Core for Safety Rating)

Main safety contacts: 3 평상시 열림 (아니요) forced-guided contacts, Stop Category 0

Auxiliary signal contact: 1 평상시 닫힘 (NC) fault feedback output (ERR diagnosis)

Contact protection fuses: 6A T for safety circuit; 2A T for auxiliary circuit

Max switching frequency: 5헤르츠; Contact resistance ≤100mΩ

  1. Safety Certification Ratings (Mechanical Safety Standards)

ISO에서 13849-1: PL 전자 / 카테고리 4 (Highest mechanical safety level)

IEC 61508: 실 3

Compliant standards: 안에 60947-5-1, ISO에서 13850 (비상 정지), 안에 60204-1 Machinery Standard

  1. 기계 & 환경 매개변수

설치: Standard snap-on 35mm DIN rail mounting

보호 등급: IP20 (For cabinet internal use only)

작동 온도: -25℃ ~ +45℃

주택: Glass fiber reinforced flame-retardant plastic

무게: 대략. 249g

터미널: 스크류 클램프 방식, suitable for 0.25~2.5mm² single/multi-strand wires

  1. 기능 & 일반적인 응용 분야

5.1 핵심 기능

Dual-channel cross-check; All safety outputs cut off immediately upon single-channel wire break or ground fault

Process passive contact signals (비상 정지, 안전문, door interlock switches)

ERR fault output for external PLC / indicator light diagnosis

No automatic reset; Safety circuit must be reclosed to reset after fault clearance

5.2 일반적인 응용 분야

Safety circuit monitoring for machine tools, 포장 장비, 자동 생산 라인, 사출 성형 기계, logistics sorting systems, lithium battery equipment and rail transit equipment

  1. Series Model Comparison (선택 참고)
모델 접미사터미널 유형Fuse Type주문 번호
LCScrew terminal 0.25~2.5m㎡Glass fuse101163475 (이 모델)
LCIPlug-in screw terminal 0.25~2.5m㎡Electronic fuseSeparate order number
LCI/7Plug-in cage clamp terminal 0.25~1.5m㎡Electronic fuseSeparate order number
LC/BCompatible with active safety light curtain signalsGlass fuse101177962
  1. Critical Risk Warnings
  2. Only applicable to passive contact safety switches. For safety light curtains (active AOPD), select model SRB301LC/B with suffix B
  3. Stop Category 0: Main circuit power cut-off with instantaneous stop; Not suitable for equipment requiring delayed braking
  4. Forced-guided contacts shall not be connected in parallel for capacity expansion; External contactors are required for heavy loads
  5. Must be matched with Cat.4 dual-channel safety components; Single-channel wiring cannot achieve PL e rating

Full Output Contact Capacity Specifications of SRB301LC-24V (부품 번호. 101163475)

  1. 3 Main Safety Normally Open Contacts (13-14 / 23-24 / 33-34)

1.1 Standard Rated Capacity for Resistive Loads

Max voltage: 250 VAC

정격전류: 6 에이 (AC-1 resistive)

Minimum reliable switching capacity: 10 다섯 / 10 엄마 (to avoid contact non-conduction)

1.2 Standard Utilization Categories (안에 60947-5-1)

AC-15 (유도 부하: AC solenoid valves / 접촉기): 230 VAC / 6 에이

DC-13 (유도 부하: DC solenoid valves): 24 VDC / 6 에이

1.3 Peak / Short-term Parameters (For Reference Only, Not for Continuous Operation)

The datasheet states a short-term limit of 8A. For engineering continuous loads, sizing shall be based on 6A. Freewheeling diodes or varistors shall be connected in parallel for arc suppression on inductive loads.

1.4 Matched Protection Fuse

Standard 6A time-lag fuse for safety circuit; Higher rated fuses are strictly prohibited.

  1. 1 Auxiliary Normally Closed Fault Contact (41-42 ERR Diagnosis)

정격 용량: 24 VDC / 2 에이

Matched fuse: 2A time-lag fuse; Only for small signal loops such as PLC feedback and fault indicator lights, not for heavy loads.

  1. 키 선택 & Operation Restrictions
  2. Parallel connection of the three safety contacts for capacity expansion is forbidden. External safety contactors must be used for loads exceeding 6A.
  3. Stop Category 0 with instantaneous cut-off, suitable for cutting off main contactor coil circuits via emergency stops and safety gates.
  4. Arc suppression circuits are mandatory for inductive loads (솔레노이드 밸브, 코일), otherwise contact service life will be drastically shortened.
  5. Derating is required at ambient temperature above 40℃; Max switching frequency is 5Hz.

Official Standard Response & Delay Specifications of SRB301LC-24V (101163475)

  1. Trip Response Time (Cut-off triggered by emergency stop / safety gate, core safety index)
  2. Maximum rated dropout delay specified in official manual: ≤50 ms
  3. Typical measured value of SRB301LC/B with identical architecture: ≤25 ms (Total breaking time of main safety contacts after dual-channel fault or emergency stop input disconnection)

> 메모: 50ms is the conservative upper limit from the manufacturer. Under normal engineering operating conditions, cut-off is generally completed within 20~30ms, complying with Stop Category 0 emergency stop safety regulations.

  1. Make Delay (Safety circuit recovery, contact closing)
  2. Make delay for manual start via reset button: 20ms 이하 (Output energized after safety gate closed and reset button pressed)
  3. Make delay under auto-start mode: ≤300 ms (Scenario without reset button, auto-energization upon power-up)
  4. Typical basic make delay stated in general datasheets: ≈30 ms
  5. Supplementary Key Notes
  6. This response time covers the total duration of dual-channel input logic detection plus internal electromechanical relay breaking, not merely mechanical contact actuation time.
  7. 단선, cross-channel short-circuit and ground fault detection also cut off safety outputs within ≤50ms.
  8. Compared with LC/B light curtain version with trip time ≤25ms, the upper limit for SRB301LC-24V (standard passive contact model) is extended to 50ms. 50ms shall be adopted for safety distance calculation in SISTEMA safety assessments.
  9. Upper switching frequency limit: 5헤르츠; Minimum full cycle make-break period: 200ms. High-frequency operation is not allowed.
  10. Reference for Safety Calculation During Selection

If the equipment requires total shutdown reaction time (스위치 + 계전기 + 접촉기), adopt the conservative value of 50ms for this relay to calculate safety distance.