Schneider LADN20 보조 접점 블록 - 접촉기,회로 차단기,태양광 인버터,전기 계량기,태양 전지

위챗: +86-13184948252 왓츠앱: 0086-13811255435 이메일: kent@bestcontactor.com

에 대한 연락하다 |

Schneider LADN20 보조 접점 블록 - 접촉기,회로 차단기,태양광 인버터,전기 계량기,태양 전지

전기 같은/

Schneider LADN20 보조 접점 블록

모델: LADN20 Brand: Schneider Electric Product Series: Matching accessories for TeSys D / TeSys Deca contactors Product Type: Front snap-on instantaneous auxiliary contact block Contact Configuration: 2아니요 (2 Normally Open contacts, no Normally Closed contacts) 장착 방법: Direct snap-fit on contactor front face, tool-free installation Applicable Contactors: LC1D09~LC1D150, CAD control relays, LC1F / CR1F series ...

  • 제품 세부정보

모델: LADN20

상표: 슈나이더 일렉트릭

제품 시리즈: Matching accessories for TeSys D / TeSys Deca contactors

제품 유형: Front snap-on instantaneous 보조 접점 블록

연락처 구성: 2아니요 (2 Normally Open contacts, no Normally Closed contacts)

장착 방법: Direct snap-fit on contactor front face, tool-free installation

Applicable Contactors: LC1D09~LC1D150, CAD control relays, LC1F / CR1F series contactors

  1. 모델 코드 분석
  2. LADN: General prefix for front-mounted auxiliary contacts of TeSys D series
  3. 2: Total number of contact circuits = 2
  4. 0: Number of NC (평상시 닫힘) contacts = 0

Full definition: 2 평상시 열림, 0 상시 폐쇄 보조 접점

Universal naming rule for the same series:

LADN02: 0아니요, 2NC

LADN11: 1아니요, 1NC

LADN22: 2아니요, 2NC

  1. Terminal Markings & Wiring Definition

Two independent NO circuits with standard terminal numbers:

1st NO circuit: 53 (입력), 54 (산출)

2nd NO circuit: 63 (입력), 64 (산출)

Terminal structure: 나사 클램프 단자, 조임 토크 1.7 N·m

Compatible wire cross-sections:

Single solid wire / ferrule-equipped flexible wire: 1~4 mm²

Two parallel wires: 1~2.5mm²

  1. 핵심 전기 사양

4.1 정격 절연 전압 Ui

690 다섯 (IEC 표준); UL/CSA certified for 600 다섯

4.2 Conventional Thermal Current Ith

10 에이 (ambient temperature 60°C)

4.3 AC-15 AC Control Load (솔레노이드 밸브 / Coils / Indicator Lamps)

120 뷔와: 6 에이

230 뷔와: 3 에이

400 뷔와: 1.8 에이

690 뷔와: 1.04 에이

4.4 DC-13 DC Inductive Load

125 DC에서: 0.55 에이

600 DC에서: 0.1 에이

4.5 Minimum Operating Condition (Suitable for Weak Signals)

Minimum switching voltage: 17 다섯; Minimum switching current: 5 엄마

4.6 Contact Operation Timing

No overlap time between make and break: 1.5 ms (NO and NC contacts never conduct simultaneously)

4.7 보호 & 환경 매개변수

보호 등급: IP20 (for indoor cabinet use only)

작동 온도: -25℃ ~ +60℃

기계적 수명: ≥ 30 백만 개의 작업

전기적 수명 (under standard load): ≥ 1 백만 개의 작업

4.8 치수 & 무게

치수: 48 (시간) × 26 (여) × 42 (디) mm; Net weight ≈ 30 g

  1. 인증 & 표준

인증: CCC, CE, UL, CSA, EAC, UKCA

준수 표준: GB/T 14048.5, IEC 60947-5-1, 안에 50012

  1. 기능 & 응용 시나리오
  2. Motor Start-Stop Feedback: Two independent passive NO signals after contactor closure, sent to PLC, indicator lamps and upper computer for operating status collection
  3. Expansion of Electrical Interlocks: Add interlock contacts for dual-motor and forward/reverse control circuits
  4. Multi-channel Alarm Output: One circuit for local panel lamps, one for remote control cabinet signals
  5. 제어 회로 확장: Supplement auxiliary contacts when factory-built contacts are insufficient (LC1D standard configuration only includes 1NO+1NC)

적용산업: 공작기계, 공조, 물 펌프, 팬, automatic production line control cabinets

  1. Selection Table for LADN Front-Mounted Contacts of the Same Series
모델연락처 구성핵심 애플리케이션
LADN202아니요Dual-channel operation feedback, no NC signal required
LADN022NCFault shutdown and open-circuit status detection
LADN111아니요+1NCOne operation signal + one fault signal (most universal)
LADN222아니요+2NCMulti-signal collection and complex interlock circuits
  1. 설치 & 교체 지침
  2. 설치: Align with the front slot of the contactor and press down until a snap sound is heard for locking; for removal, pinch both side latches and pull upward
  3. Installation Limit: A single LC1D contactor can be fitted with maximum 1 front LADN contact block. The LAD8N series side-mount modules are required for additional contacts
  4. 대체 모델

Domestic equivalents with identical functions: Delixi F4-20, Chint F4-20

Schneider side expansion contacts: LAD8N20 (side-mounted 2NO contacts)

  1. Strict Usage Prohibitions
  2. Not allowed for main power circuits; only applicable to control signals and small coil loads (AC-15 / DC-13)
  3. Forbidden to operate above the rated insulation voltage of 690 다섯
  4. Cannot be exposed outdoors or in humid unprotected environments (IP20 rating limited to cabinet interior)
  5. Do not connect multiple 4 mm² wires to one single terminal; maximum cross-section for parallel wiring is 2.5 mm²

Full Application Fields of Schneider LADN20 Auxiliary Contact Block

  1. 일반 산업 자동화
  2. Conveying Line Equipment

Collect contactor status for belt conveyors, 롤러 라인, transfer machines and lifting positioning mechanisms. Two NO circuits separately transmit local lamp signals and operation data to PLC.

  1. Custom Non-standard Automation Machines

Expand original contactor contacts on assembly machines, inspection equipment and stamping loading/unloading machines to upload equipment running status remotely.

  1. Robot Supporting Control Cabinets

Monitor solenoid valve circuits for robot external axes and fixture clamping; two isolated passive signals avoid mutual interference.

  1. Machine Tool Processing Industry (주요 응용 시나리오)
  2. CNC Lathes, 머시닝 센터, 밀링 머신

Expand contacts for spindle motors, cooling pumps and chip conveyors. One signal feeds local panel running lamps, the other transmits ready signals to the machine tool system.

  1. Grinding Machines & Drill-Tap Centers

Collect start-stop status of lubrication pumps and hydraulic stations to meet the demand for synchronous multi-signal output on machine tools.

  1. Stamping & Sheet Metal Machines

Realize status interlock and signal upload for main hydraulic motors and feeding motors.

  1. 공조, 상수도 & 배수, 전기 기계 시스템 구축
  2. 팬 & Water Pump Control Boxes

For air conditioning fans, 냉각탑 팬, circulating pumps and sewage pumps, two NO contacts deliver local indication signals and communication data to building BA systems respectively.

  1. Central Air Conditioning Units

Expand contact terminals for chillers and condensate pumps for remote building monitoring.

  1. Fire-fighting Supporting Equipment

Upload operating status of smoke exhaust fans and sprinkler pumps to fire alarm control panels.

  1. 리프팅 장비, 기호 논리학 & Warehousing Machinery
  2. Overhead Cranes & Electric Hoist Control Cabinets

Collect running signals of lifting, cross-travel and long-travel contactors. Two signal channels serve local display and upper warehouse management systems separately.

  1. Automated Warehouses & Stackers

Transmit status feedback of traveling motors and fork lifting motors for stacker safety interlock judgment.

  1. 에너지, 공조 & Environmental Protection Equipment
  2. Air Compressor & Vacuum Pump Control Cabinets

Monitor main loading motors and cooling fans; upload operation data to energy management systems for runtime statistics.

  1. Sewage Treatment Equipment

Multi-channel status collection for aeration fans, dosing pumps and sludge transfer pumps.

  1. PV Auxiliary Equipment

Output start-stop signals for cooling fans and circulating water pumps.

  1. 고무 & 플라스틱, 포장 & 인쇄 산업
  2. Injection Molding & Extrusion Machines

Transmit operation feedback of screw motors, mold temperature machine water pumps and conveyor belts.

  1. 포장 & Printing Machines

Two independent signal outputs for film feeding and winding motors to distinguish local alarm and remote monitoring signals.

  1. 철도 운송 & EV Charging Pile Supporting Systems
  2. Status collection for charging pile cooling fans and main contactors
  3. Signal expansion for station ventilation and water pump electromechanical control cabinets
  4. Application Matching Features (Matching LADN20’s 2NO-only characteristic)

Universal requirement across all industries: only collect power-on running status without open-circuit fault signals; two isolated passive switching signals with separate grounding and no voltage conflict.

Select LADN11 (1아니요+1NC) if both running and shutdown fault signals need to be collected simultaneously.