모델: LADN20
상표: 슈나이더 일렉트릭
제품 시리즈: Matching accessories for TeSys D / TeSys Deca contactors
제품 유형: Front snap-on instantaneous 보조 접점 블록
연락처 구성: 2아니요 (2 Normally Open contacts, no Normally Closed contacts)
장착 방법: Direct snap-fit on contactor front face, tool-free installation
Applicable Contactors: LC1D09~LC1D150, CAD control relays, LC1F / CR1F series contactors
- 모델 코드 분석
- LADN: General prefix for front-mounted auxiliary contacts of TeSys D series
- 2: Total number of contact circuits = 2
- 0: Number of NC (평상시 닫힘) contacts = 0
Full definition: 2 평상시 열림, 0 상시 폐쇄 보조 접점
Universal naming rule for the same series:
LADN02: 0아니요, 2NC
LADN11: 1아니요, 1NC
LADN22: 2아니요, 2NC
- Terminal Markings & Wiring Definition
Two independent NO circuits with standard terminal numbers:
1st NO circuit: 53 (입력), 54 (산출)
2nd NO circuit: 63 (입력), 64 (산출)
Terminal structure: 나사 클램프 단자, 조임 토크 1.7 N·m
Compatible wire cross-sections:
Single solid wire / ferrule-equipped flexible wire: 1~4 mm²
Two parallel wires: 1~2.5mm²
- 핵심 전기 사양
4.1 정격 절연 전압 Ui
690 다섯 (IEC 표준); UL/CSA certified for 600 다섯
4.2 Conventional Thermal Current Ith
10 에이 (ambient temperature 60°C)
4.3 AC-15 AC Control Load (솔레노이드 밸브 / Coils / Indicator Lamps)
120 뷔와: 6 에이
230 뷔와: 3 에이
400 뷔와: 1.8 에이
690 뷔와: 1.04 에이
4.4 DC-13 DC Inductive Load
125 DC에서: 0.55 에이
600 DC에서: 0.1 에이
4.5 Minimum Operating Condition (Suitable for Weak Signals)
Minimum switching voltage: 17 다섯; Minimum switching current: 5 엄마
4.6 Contact Operation Timing
No overlap time between make and break: 1.5 ms (NO and NC contacts never conduct simultaneously)
4.7 보호 & 환경 매개변수
보호 등급: IP20 (for indoor cabinet use only)
작동 온도: -25℃ ~ +60℃
기계적 수명: ≥ 30 백만 개의 작업
전기적 수명 (under standard load): ≥ 1 백만 개의 작업
4.8 치수 & 무게
치수: 48 (시간) × 26 (여) × 42 (디) mm; Net weight ≈ 30 g
- 인증 & 표준
인증: CCC, CE, UL, CSA, EAC, UKCA
준수 표준: GB/T 14048.5, IEC 60947-5-1, 안에 50012
- 기능 & 응용 시나리오
- Motor Start-Stop Feedback: Two independent passive NO signals after contactor closure, sent to PLC, indicator lamps and upper computer for operating status collection
- Expansion of Electrical Interlocks: Add interlock contacts for dual-motor and forward/reverse control circuits
- Multi-channel Alarm Output: One circuit for local panel lamps, one for remote control cabinet signals
- 제어 회로 확장: Supplement auxiliary contacts when factory-built contacts are insufficient (LC1D standard configuration only includes 1NO+1NC)
적용산업: 공작기계, 공조, 물 펌프, 팬, automatic production line control cabinets
- Selection Table for LADN Front-Mounted Contacts of the Same Series
| 모델 | 연락처 구성 | 핵심 애플리케이션 |
| LADN20 | 2아니요 | Dual-channel operation feedback, no NC signal required |
| LADN02 | 2NC | Fault shutdown and open-circuit status detection |
| LADN11 | 1아니요+1NC | One operation signal + one fault signal (most universal) |
| LADN22 | 2아니요+2NC | Multi-signal collection and complex interlock circuits |
- 설치 & 교체 지침
- 설치: Align with the front slot of the contactor and press down until a snap sound is heard for locking; for removal, pinch both side latches and pull upward
- Installation Limit: A single LC1D contactor can be fitted with maximum 1 front LADN contact block. The LAD8N series side-mount modules are required for additional contacts
- 대체 모델
Domestic equivalents with identical functions: Delixi F4-20, Chint F4-20
Schneider side expansion contacts: LAD8N20 (side-mounted 2NO contacts)
- Strict Usage Prohibitions
- Not allowed for main power circuits; only applicable to control signals and small coil loads (AC-15 / DC-13)
- Forbidden to operate above the rated insulation voltage of 690 다섯
- Cannot be exposed outdoors or in humid unprotected environments (IP20 rating limited to cabinet interior)
- Do not connect multiple 4 mm² wires to one single terminal; maximum cross-section for parallel wiring is 2.5 mm²
Full Application Fields of Schneider LADN20 Auxiliary Contact Block
- 일반 산업 자동화
- Conveying Line Equipment
Collect contactor status for belt conveyors, 롤러 라인, transfer machines and lifting positioning mechanisms. Two NO circuits separately transmit local lamp signals and operation data to PLC.
- Custom Non-standard Automation Machines
Expand original contactor contacts on assembly machines, inspection equipment and stamping loading/unloading machines to upload equipment running status remotely.
- Robot Supporting Control Cabinets
Monitor solenoid valve circuits for robot external axes and fixture clamping; two isolated passive signals avoid mutual interference.
- Machine Tool Processing Industry (주요 응용 시나리오)
- CNC Lathes, 머시닝 센터, 밀링 머신
Expand contacts for spindle motors, cooling pumps and chip conveyors. One signal feeds local panel running lamps, the other transmits ready signals to the machine tool system.
- Grinding Machines & Drill-Tap Centers
Collect start-stop status of lubrication pumps and hydraulic stations to meet the demand for synchronous multi-signal output on machine tools.
- Stamping & Sheet Metal Machines
Realize status interlock and signal upload for main hydraulic motors and feeding motors.
- 공조, 상수도 & 배수, 전기 기계 시스템 구축
- 팬 & Water Pump Control Boxes
For air conditioning fans, 냉각탑 팬, circulating pumps and sewage pumps, two NO contacts deliver local indication signals and communication data to building BA systems respectively.
- Central Air Conditioning Units
Expand contact terminals for chillers and condensate pumps for remote building monitoring.
- Fire-fighting Supporting Equipment
Upload operating status of smoke exhaust fans and sprinkler pumps to fire alarm control panels.
- 리프팅 장비, 기호 논리학 & Warehousing Machinery
- Overhead Cranes & Electric Hoist Control Cabinets
Collect running signals of lifting, cross-travel and long-travel contactors. Two signal channels serve local display and upper warehouse management systems separately.
- Automated Warehouses & Stackers
Transmit status feedback of traveling motors and fork lifting motors for stacker safety interlock judgment.
- 에너지, 공조 & Environmental Protection Equipment
- Air Compressor & Vacuum Pump Control Cabinets
Monitor main loading motors and cooling fans; upload operation data to energy management systems for runtime statistics.
- Sewage Treatment Equipment
Multi-channel status collection for aeration fans, dosing pumps and sludge transfer pumps.
- PV Auxiliary Equipment
Output start-stop signals for cooling fans and circulating water pumps.
- 고무 & 플라스틱, 포장 & 인쇄 산업
- Injection Molding & Extrusion Machines
Transmit operation feedback of screw motors, mold temperature machine water pumps and conveyor belts.
- 포장 & Printing Machines
Two independent signal outputs for film feeding and winding motors to distinguish local alarm and remote monitoring signals.
- 철도 운송 & EV Charging Pile Supporting Systems
- Status collection for charging pile cooling fans and main contactors
- Signal expansion for station ventilation and water pump electromechanical control cabinets
- Application Matching Features (Matching LADN20’s 2NO-only characteristic)
Universal requirement across all industries: only collect power-on running status without open-circuit fault signals; two isolated passive switching signals with separate grounding and no voltage conflict.
Select LADN11 (1아니요+1NC) if both running and shutdown fault signals need to be collected simultaneously.
접촉기,회로 차단기,태양광 인버터,전기 계량기,태양 전지